Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.0 CrAccepted-AOC | ₹4.0 Cr | L-1 | Accepted-AOC AOC done |
| 2 | L-2₹5.2 Cr+₹1.2 Cr (28.6%)Rejected-Finance | ₹5.2 Cr+₹1.2 Cr (28.6%) | L-2 | Rejected-Finance Not-responsive |
Tender Value
₹5.5 Cr
EMD Value
₹11.0 L
Closing Date
21 May 2025, 11:00 amClosed
Executive Engineer Electrical Division HPPWD. Una
Electrical Division HPPWD. Una
C/o Indoor Multipurpose Sports Complex at Kharidi Ground Nadaun Distt Hamirpur (HP) (SH- SITC VRV/VRF System therein)
2025_PWD_105161_1
NIT No. 657-87 dated 06.05.2025
Open Tender
Electrical Works
Percentage
540 days
Una
Please refer Tender documents.
8 documents required · 8 mandatory
₹10,000
₹11.0 L
4 Aug 2026
9 May 2025
21 May 2025
9 May 2025
21 May 2025
9 May 2025
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14(Forteen) HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410(Four hundred ten ) A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400(four hundred)V +/- 10%,3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.The outdoor Unit and compressor should be of same make. The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble.Make :- DAIKIN / O GENERAL/ MITSUBISHI ELECTRIC/TOSHIBA | |||||
| 1.01 | ALL FLOOR AC | 590 | PER HP | 25,948 | ₹1,53,09,320 |
| 2INDOOR UNIT - CASSETTE | |||||
| 2.01 | Supply, installation, testing and commissioning of following minimum capacity 4/1-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalbleMake :- DAIKIN / O GENERAL/ MITSUBISHI ELECTRIC/TOSHIBA | - | - | - | - |
| 2.02 | 2.0(Two) TR (4 way) | 4 | EACH | 72,673 | ₹2,90,692 |
| 3INDOOR UNIT - HIGH WALL TYPE | |||||
| 3.01 | Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27(Twenty seven) Degree C DB and 19 Degree C WB temperature.The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalbleMake :- DAIKIN / O GENERAL/ MITSUBISHI ELECTRIC./TOSHIBA | - | - | - | - |
| 3.02 | 0.6(Point six) TR | 1 | EACH | 32,872 | ₹32,872 |
| 3.03 | 0.8(point eight)TR | 2 | EACH | 33,436 | ₹66,872 |
| 3.04 | 1.3(one point three) TR | 3 | EACH | 36,095 | ₹1,08,285 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_154124.xls
BOQ • 0.42 MB
170141889.pdf
Tender Documents • 1.29 MB
170141896.html
Tender Documents • 0.06 MB
SBD.pdf
Tender Documents • 3.88 MB
undertaking.pdf
Tender Documents • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .