| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Due to Lower Rates | |
| 2 | L2₹19.3 L+₹2.6 L (15.6%)Rejected-Finance | L2 | Rejected-Finance Due to higher Rates |
| Sl No | Description | Qty | Unit | AR CONTRACTORS L2 | ADS CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Dismentelling glazed wall tiles | 61.48 | sqm | 145 ₹8,916.05 | 140 ₹8,608.6 Lowest |
| 2.00 | Dismentelling Brick work in cement | 10.78 | cum | 730 ₹7,869.4 | 720 ₹7,761.6 Lowest |
| 3.00 | Scraping Cement plaster | 606.01 | sqm | 40 ₹24,240.4 | 37 ₹22,422.37 Lowest |
| 4.00 | Cement Rendering 1mm thick on cement plaster work | 488.36 | cum | 70 ₹34,185.2 | 65 ₹31,743.4 Lowest |
| 5.00 | 20mm thick cement plaster 14. | 491.28 | sqm | 310 ₹1,52,296.8 | 300 ₹1,47,384 Lowest |
| 6.00 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. | 18.03 | cum | 7,500 ₹1,35,225 | 7,400 ₹1,33,422 Lowest |
| 7.00 | Scraping White wash and colour wash etc. | 354.74 | sqm | 6 ₹2,128.44 | 5 ₹1,773.7 Lowest |
| 8.00 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish. | 373.67 | sqm | 86 ₹32,135.62 | 85 ₹31,761.95 Lowest |
| 9.00 | Applying Priming coat with cement primer in all shades on newly plastered or conc surface | 373.67 | sqm | 30 ₹11,210.1 | 25 ₹9,341.75 Lowest |
| 10.00 | Wall painting with plastic emulsion paint of approved brand to give an even shade 2 coats | 571.32 | sqm | 95 ₹54,275.4 | 93 ₹53,132.76 Lowest |
Tender Value
₹16.4 L
EMD Value
₹32,800
Closing Date
21 Nov 2025, 12:00 pmClosed
Executive Engineer Devigarh Patiala Division
Executive Engineer/Devigarh Patiala Canal and Ground Water Division WRD Punjab Patiala
Estimate for Repair and Renovation of Xen Devigarh Residence
2025_WR_153324_1
35/2025-26
Open Tender
Civil Works
Item Rate
90 days
Patiala
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
₹32,800
Yes
17 Mar 2026
7 Nov 2025
21 Nov 2025
7 Nov 2025
21 Nov 2025
7 Nov 2025
Amount
Dismentelling glazed wall tiles
Dismentelling Brick work in cement
Scraping Cement plaster
Cement Rendering 1mm thick on cement plaster work
20mm thick cement plaster 14.
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.
Scraping White wash and colour wash etc.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish.
Applying Priming coat with cement primer in all shades on newly plastered or conc surface
Wall painting with plastic emulsion paint of approved brand to give an even shade 2 coats
Finishing walls with acralic smooth exterior paint of reqdshade with 2 or more coatsapplied @ 1.67kg/10sqm over and incl. base coat of water proofing cement paint @ 2.20kg/10sqm
P & applying Anti termite treatment using post constructional chemical treatment using chemical containg choloropyrifos systemic insecticide diluted & injecting with chemical solution
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Reinforced cement cocrete M-20 mechanically batch mixed using Batch type concrete mixer and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering in superstructure.
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade, for R.C.C. works where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20mm(average) thick baseofcementmortar1:4(1cement :4coarse sand) laidand jointedwithgrey cement slurry, including rubbing and polishing complete with :
Stripping & stacking tiles of roof
Dismentelling brick or flagged stone flooring without conc base
e/w excavation with kassi work undressed invovolving horizontal throw & vertival lift incl. breaking of clods
Scrapping mud plaster
washing conc. surface scrubbing with brushes incl. preparing & laying slurry
Nicking cement concrete surface (over 28 days old incl preparing and laying slurry
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Cement concrete 1:2:4 gola 10 cm x 10 cm quardrant type
scrapping of old tiles dismentelled/removed from the terracing work in cement
Making Top khurra 0.6x0.6m for rain water pipe in 25mm th cement cion 1:2:4 over 50mmth cement conc 1:8:16
Bottom khurra on ground 1.2m x 0.6m consisting of bricks laid in CM 1:3 over 7.5 cm cement conc 1:8:16 incl 12.5 mm th cement plaster 1:30.6x0.6m for rain water pipe in 25mm th cement cion 1:2:4 over 50mmth cement conc 1:8:16
Providing and fixing 110mm dia UPVC Rain water pipes incl jointing complete
Providing and fixing 110mm dia UPVC Bend for Rain water pipes incl jointing complete
Providing and fixing 110mm dia UPVC coupling/sockets for Rain water pipes incl jointing complete
P & fixing MS clamps for Rain water pipes
door + almiras & cup boards
Dismentelling wire gauge with frame work
Fixing chowkhats in existing opening including embending chowkhats in floor or walls, cutting masonry & fixing hold fasts in cement concrete 1:3:6, painting two coats of coal tar to sides of chowkhats and making good the damages to walls and floors complete to match the existing surface :-- for door chowkhats
Fixing chowkhats in existing opening including embending chowkhats in floor or walls, cutting masonry & fixing hold fasts in cement concrete 1:3:6, painting two coats of coal tar to sides of chowkhats and making good the damages to walls and floors complete to match the existing surface :-- for window chowkhats
Fixing chowkhats in existing opening including embending chowkhats in floor or walls, cutting masonry & fixing hold fasts in cement concrete 1:3:6, painting two coats of coal tar to sides of chowkhats and making good the damages to walls and floors complete to match the existing surface :-- for clerestory window (vents)
chowkats of commercial hard wood such as Champ (ASSAM) for doors & windows including iron hold fasts iron hinges corner straps clears, stops wooden knobs fixed in position. Double Rebate (60mm x 150mm)
chowkats of commercial hard wood such as Champ (ASSAM) for doors & windows including iron hold fasts iron hinges corner straps clears, stops wooden knobs fixed in position. Single Rebate (60mm x 100mm)
Factorymanufactured flushdoor fixed in position iron hinges, etc (excluding the cost of any fittings other than specified abovebut including labour for fixing the same in position
Wire gauge Door shutters with Kail wood without springs housed in chowkhats
Deodar wood plan king planed on both sides i.e.basedand fixed in position including nails and screws etc.
P/Fixing beading to door & window chowkhats of commercial hard wood with iron screws.Size 50x12mm
Iron gratted doors,incl pintle hinges and arrangments
Fixed glass panes 5mm thick
Sliding bolts 300x16mm
brass 100mm mortice latch and lock with 6 levers and handles
Hydralic door closer
Curtain rods 25mm dia
Brass cup board locks
stainless steel ball bearing hinges
Prepration of plywood surface for painting incl sand papering
Spirit polishingtwo coats includinga coat of wood filler on wood work
Painting 2coats with synethetic enemal paint
Providing and fixing commercial plywood 12 mm thick
Providing and fixing commercial plywood 18mm thick
Providing and fixing commercial plywood 25mmmm thick
Providing & Fixing decorative high pressure laminated sheet 1mm (1 Star) thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Providing&Fixing decorative laminated sheet 0.72mmthick and reversesideof adhesivebondingqualityconformingtoIS :2046TypeS, includingcostofadhesive of approved quality.
Providing & Fixing 6" stainless steel handles ISI marked on doors & window frames complete in all respect as per the directions of engineer in charge
Providing & Fixing 1'-3" stainless steel handles ISI marked on doors & window frames complete in all respect as per the directions of engineer in charge
Providing & Fixing 0'-6" stainless steel tower bolts ISI marked on doors & window frames complete in all respect as per the directions of engineer in charge
Providing & Fixing 12" stainless steel tower bolts ISI marked on doors & window frames complete in all respect as per the directions of engineer in charge
Providing & fixing Stainless steel ball bearing hinges of size 100x 89 x 3mm ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacemetc. Twoormorecoatstogivean even shade
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge24-02-2025-Providing and fixing CPVC pipe CPVC SDR 11 Pipe and fittings 25mm o/d
P/F brass ball walve 25mm dia
P/F and jointing Union Coupling in GI pipes lines 25mm dia
P/F and jointing Union Coupling in GI pipes lines 40mm dia
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition.
P/F Man hole cover & frame a I 450mm i/d RCC man hole cover & frame
Constructing brick masonry manhole in cementmortar1:5(1cement :5coarsesand )R.C.C. topslab20cmthickusingM-20mix byusingmixerandvibrator, TMTFe500@ 80.00kg/per cum, foundationconcrete1:4:8 mix (1 cement: 4 coarse sand : 8 graded stoneaggregate40mmnominal size) inside plastering12mmthickwithcementmortar1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1cement : 2coarsesand : 4graded stoneaggregate20mmnominalsize)finished witha floatingcoat of neat cement,Orange colouredPVCstepsincludingRCCcoverwith frame complete as per standard design complete in all respects.( Inside size 75x120 cm and 120 cm deep
Making connection of sewer line with existing man hole( a) for pipes 100 to 250 mm dia
Providing and fixing in position vitreous china ware white lavatory suits of approved make including brasstuds without CP fittings size 450mmx300mm
P/F C P brass pillar cock foam flow
Waist pipe PVC 32mm dia
Providingand fixing inpositionC.P. brass overhead shower 1 flowwith shower arm with15mmi/dinlet ofapprovedmake(to the approval ofEngineer-in-charge) complete in all respect..
Providing and fixing in position Chinaware Floor mounted European type one pieceEWC with matching cistern with P or S trap (to the approval of the Engineer-in-charge) with seat cover complete in all respect and to the entire satisfaction of engineer in charge. b floor mounted EWCsize 69x36x74 cm
Providing and fixing jet spray with 2'-6" long PVC pipe.
P/F in position 5 mm thick bevelled edgeof superior glass mirror 4mm thick hard board backing of required shape complete in all respectssize 600mm x 450mm
Providing and fixingStainless steel health faucet complete in all respect.
Providing & fixing in position best Indian make PVC flexible tube connection. B PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut
Providing & Fixing in position C.P. Brass flange under various fixtures complete in all respects (as required by the Engineer-in- Charge)
C.P.brass 15mm Angular stop cock with Wall flange
C.P brass Sink mixer with regular spout tablemountedwith450mm long flexible hose.
Providing and fixing in position gratings 150mm x 150mm for gully trap.
Providing and fixing in position SWR UPVC soil waste vent pipe or anti syphonage pipe 110 mm OD laid complete.
Providing and fixing in position HCI specials for soil waste vent or anti syphonage pipe to specifications HR Bend .
cement concrete 1:2:4 with stone aggregate 20 mm size.
Providing and fixing CP brass extension piece 25mm to 50mm long of approved make complete.
Floor Trap 110mm dia
prov and placing HDPE water storage tank
25mm dia GI tank nipple
Plastic ball cock with rod & plastic ball
Providing &Fixing in postion stop cock / Angle valve of approved make (to the approvalofEngineer-in-charge)completein all respect.( C.P.brass 15mm concealed stop cock with flange)
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (Without fan box)
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring light point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- wiring call bell point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring 3 pin 6Amp. wall socket point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring 3 pin 6Amp. power plug control wall socket point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring 3 pin 16/20Amp. power plug control point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes( 1.6 mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined / universal Socket (shuttered), 6/10Amp. Switches,16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring light point with double control switches.
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-:-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.0 sq.mm (Un-sheathed)
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5 sq.mm (Un-sheathed)
Supply & erection of PVC Conduit Pipes(ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (flushed)
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications includingconnections with suitable size of thimbles/lugs:- MCB single pole Pole 6-32amp. (10kA, Curve-C)
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications includingconnections with suitable size of thimbles/lugs:- MCB Double Pole 6-32amp. (10kA, CurveC)
Erection of Ceiling fans ( Labour rate only)
Erection of Exhaust fan with louver shutter on the wall/ window grill
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement
supply and erection of switch socjet and other accessories. one way 6 amp flush oiano switch
supply and erection of switch socjet and other accessories. one way 6 amp bell push
supply and erection of switch socjet and other accessories. 5 pin 6 amp socket
supply and erection of switch socjet and other accessories. 16 amp universal wall socket
supply and erection of switch socjet and other accessories. step type fan regulator switch size
supply and erection of switch socjet and other accessories. signle pole 16 amp switch with indicator
Supply and erection of brown bakelite sheet white glazed translucent backside painted 3mm thick (thickness not less than3mm) on theexistingmetal box includingcutting, fixing and connectionof existing switches and sockets and other petty material etc.
Powder Coated Concealed Metal Box with Brass Lugs Eight Module
AR CONTRACTORS (BID ID -699822)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.50 MB
BOQ_310894.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .