Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹42.1 L+₹3.3 L (8.48%)Rejected-Finance OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹42.2 L+₹3.4 L (8.76%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹42.6 L+₹3.9 L (9.94%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹42.8 L+₹4.1 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
21 Mar 2022, 6:00 pmClosed
GE HADDO
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDN/ALTN ANDSPECIAL REPAIRS TO BLDG NO P-86 AND PROVISION OF VISITOR ROOM AND STORAGE SHED AT NAVY PARK UNDER GE HADDO, PORT BLAIR
2022_MES_511491_1
8616/E8
Open Tender
Civil Works
Item Rate
180 days
HADDO, PORT BLAIR
As per tender documents
8 documents required · 8 mandatory
₹500
GE HADDO
₹83,000
Yes
4 Apr 2022
2 Mar 2022
28 Mar 2022
2 Mar 2022
21 Mar 2022
16 Mar 2022
3 Mar 2022 - 11 Mar 2022
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum and getting out in hard/dense soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for hardcore using broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for sand filling under floors in foundations,Spreading, levelling in layers not exceeding 25cm thick as in floors using earth obtain from excavation, well rammed and watered complete all as specified.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 8 to 10 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for pre-cast cement concrete solid building blocks or slabs made up of (1:3:6) type B1 (using 20mm graded stone aggregate), 10cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished even and smooth complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
SUPPLY ONLY 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
SUPPLY ONLY 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, others parts made of mild steel heavy duty and fixed complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
M&L for applying 2 to 3mm thick wall care putty on wall / ceiling surfaces complete all as specified and as directed
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of oil bound distemper over a coat of primer from the same manufacturer after filling the cracks with filler complete all as specified and as directed.
M&L for complete removal of existing treatment on plastered wall surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
Dismantling structural steel work as in frame work of any description complete all as specified and as directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F 19/20mm thick plywood boarding, grade BWR, type BB as in eaves/barge boards fixed with screws on flat iron/timber frame work support and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new wood or wood based materials of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on ceiling / wooden door and window surface complete all as specified and as directed.
S&F PVC coated 25mm dia curtain rod, made of mild steel, any colour, with end brackets fancy type including 10 Nos riges per RM complete all as directed and approved by Engr-in-charge
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F aluminum flat wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in plinth protection, surface of concrete finished even and smooth without using extra cement including necessary formwork complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic designed coloured tiles in vertical surfaces using size of tiles 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for heavy duty parking area tiles of size 300x300x10.8mm thick, or high dimension (except thickness) of any colour any design Durastone, weather proof impact resistant, abrasion resistant exterior tiles, as in floors etc , set and jointed in neat cement slurry over and pointed in white or coloured cement to match, over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for vitreous China, wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and as directed.
S&F in repairs vitreous China urinal with top inlet, half stall type coloured complete fixing with suitable fixing arrangements to wall with and including cp urinal spreader, CP domed 32mm bore dia waste coupling and waste pipe complete all as specified and as directed
M&L for vitreous China wash hand basin, white, flat back, size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand, 32mm dia waste coupling brass chromium plated, bottle trap 32mm bore brass chromium plated with necessary packing union and caps, chain and plug, PVC connections 15mm size with PTMT nuts of length 450mm, screwed down for iron pipe or for unions complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S&F health faucet, brass, chromium plated with 8mm dia, 1.0 m long flexible tube, screwed for iron pipe or for brass ferrule 15mm dia or bore complete all as specified and as directed. MAKE: ZIM Cat part No. 1624A or equivalent in PARRYWARE/ PRAYAG
S&F pillar tap, brass, 15mm dia, chromium plated, fancy type with capstan heads, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed. MAKE: PRAYAG Cat part No. PIS-02H or equivalent in PARRYWARE/ZOLOTO/JOHNSON
S&F bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed. MAKE: PRAYAG Cat part No. PIS-08H or equivalent in PARRYWARE/ ZOLOTO/ JOHNSON
S&F angle valves 15mm dia or bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
M&L for PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and as directed.
S&F 20mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
S&F 25mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
M&L for Cutting chases in PCC block masonry walls, for shelves, lintels, edges of landing etc., and making good, cutting not exceeding 10 cm girth complete all as specified and directed.
S&F in repairs stainless steel grating cover 100mm dia fixed with white cement complete all as specified
S&F soap dish, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. AQN-7731 or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
S&F tubular towel rail, brass, chromium plated, 20mm dia, 60 cm long between flanges, complete all as specified and as directed. MAKE: PRAYAG Cat part No. BA-70 or equivalent in PARRYWARE/ ZOLOTO/ JOHNSON
S&F 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends with access door, any radius, diameter of outlet 75 mm complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal, diameter of outlet 75 mm complete all as specified and as directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement, diameter of outlet 75 mm, fixed in repairs complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as per specification & drawing, fixed in opening complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing fixed to door frame in repairs complete all as specified and as directed.
S&F 75mm size butt hinges, stainless steel fixed with stainless steel screws complete all as specified and as directed.
S&F 150mm aluminium barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed
S&F sliding door bolt, 300mm long, aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F 150mm size aluminium handles, cast type, anodised complete all as specified and as directed.
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Grade E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979, Grade St-240 complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
S&F 12mm thick second class hard wood boarding as in ceiling boards fixed with screws in any situation, clean sawn with butt joints complete all as specified and as directed.
S&F 20mm thick second class hard wood boarding as in eaves/barge boards fixed with screws in any situation, clean sawn with butt joints complete all as specified and as directed.
M&L for second class clean sawn hard wood in scantlings,timber framed in circular/ rectangular sections and fixed with nails or embedded to foundation complete all as specified and as directed.
Planning the wooden surfaces of softwood complete all as specified and as directed.
S & F 12mm thick sheet glass, ordinary quality, in squares exc 0.5Sqm each pane as per instructions of manufactures complete all as specified and as directed.
M&L for preparation of new wooden surfaces and applying melamine polish through the process of sanding with wood sanding paper of size 60 & 80 and applying wood filler mixed with NCD thinner including applying wood putty on shabby/ nailing area and sanding with sand paper of size 120 and applying sealer and walnut colour stainer ad sanding with sand paper of size 320 ad melamine polishing with spray application and again sanding with 400 sand paper and finally applying waxpol (Silicon Make) with soft fine cloth for better shining and finishing complete.
M&L for 18-20 mm thick granite slab (of approved shade), machine cut, as in counter slab of WHB work (table rubbed and polished /rough) in steps, risers, cooking platforms, and the like laid over 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including chamferring the edges complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block, glossy finished, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade, made of grey cement and pigments, any pattern, laid in floors, laid dry including filleting to edges in CM (1:4) complete all as specified and as directed.
S&F in repairs rotational moulded polyethylene water storage tanks, triple layered, ISI marked (cylindrical vertical with closed top), 500 litres capacity, hoisted and fixed in position all as specified in SSR Part I, 2009 including 20mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 210gms) screwed for iron pipe, provision of 40mm/25mm spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
Supply only 5.0 mm thick figured glass, pin head type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F stainless steel D shaped handle pair of min 300mm length and minimum 200mm dia including drilling hole in glass sheet of any thickness and fixing arrangements,complete all as specified and as directed.
Supply, install, test & commissioning of Split type air conditioner, 2.0 TR capacity,BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum 8 RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, 01 No spare PCB for each AC complete all as specified and as directed. MAKE: BLUESTAR /VOLTAS/LG/HITACHI NOTE: All connected pipes shall be covered with PVC casing and capping.
S&F Electronic voltage stablizer of 4 KVA capacity, wall mounting type having features such as Intelligent time delay system of 2 to 4 minutes, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations, thermal over load protection, wide input variation between 165 Volts to 295 Volts with output voltage stablized at 200 Volts to 240 Volts, with accuracy of +2.5% suitable for split type airconditioner complete all as specified and as directed. MAKE: V-GUARD / WINITECH /MICROTEK / APLAB
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
Taking down old Unserviceable fuse unit / DBs 415 Volt/ 230 volt
Taking down old aluminium sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade including proper colour coding Phase- Red/yellow/blue, neutral-black and earth green and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:- Make : Gloster / Havells / Anchor / Polycab / Finolex
One LIGHT point controlled by ONE 1 way 6 Amps switch.
ONE 6A SOCKET OUTLET point controlled by ONE 1 way 6 Amps switch on independent board.
ONE 6A SOCKET OUTLET point controlled by ONE 1 way 6 Amps switch on same board.
ONE BELL point controlled by one, one bell push 6 Amps switch.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade including proper colour coding Phase- Red/yellow/blue, neutral-black and earth green and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
S&F modular switch, one way, one module, single pole, 6 Amps , 230 Volts AC circuit complete all as specified and as directed. Make : Roma (Anchor) / Legrand / Simens / Havells
S&F modular switch, one way, one module, single pole, 16 Amps complete all as specified and as directed. Make : Roma (Anchor) / Legrand / Simens / Havells
S&F switch socket outlet, 3 pin, 16A, flush type, multipurpose, 240 volts complete all as specified and as directed. Make : Roma (Anchor) / Legrand / Simens / Havells
S&F socket outlet modular type, one way, 6 Amps , 3 pin flush type, 230 Volts AC circuit complete all as specified and as directed. Make : Roma (Anchor) / Legrand / Simens / Havells
S&F modular bell push, 6 amps, 1 module, 230 volts complete all as specified and as directed. Make : Roma (Anchor) / Legrand / Simens / Havells
S&F starter switch of capacity 25 Amps working on 240 Volts, AC supply suitable for split type airconditioner complete all as specified and as directed. MAKE: CRAB TREE Cat part No. ACTO252504 or equivalent in ANCHOR/HAVELLS/L&T
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
S&F electric bell, single pole, 230 volts, AC supply complete all as specified and as directed.
S&F ceiling fan of three blades metallic colour, brown colour, 1200mm sweep, 1400 RPM, suitable for AC 230 volts, heavy duty with down rod and canopies complete all as specified and as directed. MAKE: Bajaj/ Havells/ Usha
S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 240 volts complete all as specified and as directed. Make : Roma (Anchor) / Legrand / Simens / Havells
S&F wall mounting fan, 400mm (16") sweep, 65% electricity saving, 50 Watts, 1300 RPM, Air velocity 70CMM (m^3/min) working on 230 volts, 50 Hz, single phase, AC supply, heavy duty, aluminium alloy blades with double ball bearings, sturdy closed mesh guard protection complete with all accessories including provision of 3 core twisted copper conductor cable of suitable gauge with plug top from socket outlet to connector of fan complete all as specified and as directed. MAKE: CG, Model: Crompton HiFlo, or equivalent in HAVELLS/USHA/ ALMONARD
S&F new GI brackets of GI pipe light grade of size 25mm dia including nuts, bolts and washers for building security light complete all as specified and directed.
S&F LED security light fitting, 1x25 watts, 230 volts, 50Hz Ac supply, with high power and high efficiency long life LEDs with built-in electronic driver, unique peanut lens to ensure uniform distribution completely housed, complete all as specified and as directed. MAKE:CROMPTON Cat Part No. LSTS-25-CDL-M or its equivalent in Philips/ Havells
S&F recessed mounted 18 watts, down light round shape, LED panel light fitting with ultra bright luminarie comprising thermally conductive material, pre wired with high efficiency electronic driver with all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: PHILIPS Cat part No. Astra Max Metal Panel/ CROMPTON GREAVES Cat Part LSCRM-18W-CDL/NW/WW or equivalent in HAVELLS/C&S
S&F recessed mounted 15 watts, down light round shape, LED panel light fitting with ultra bright luminarie comprising thermally conductive material, pre wired with high efficiency electronic driver with all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: PHILIPS Cat part No. Astra Max Metal Panel/ CROMPTON GREAVES Cat Part LSCRM-15W-CDL/NW/WW or equivalent in HAVELLS/C&S
S&F LED Bollard with round top 9 to 10 Watts, 220V, 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation, 3 core 2.5 Sqmm multistranded copper conductor drawn through and including 25mm dia rigid PVC conduits from one light to other (approx distance 100 metres) with cable connectors including taking down old unserviceable one complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LBLSN-10-CDL or equivalent in BAJAJ/ HAVELLS
S&F LED flood light fittings of high power LED with toughened glass, 70 Watts capacity, 220 Volts, 50 Hz, pressure die cast aluminium housing, IP 66 Class-I protection, luminous intensity of 115 lumens/watt with power factor >0.9 along with suitable mounting bracket fixed on high mast of 16.0 metres height including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cat part No. BVP141-LED70-CW-FG-GR-PSU or equivalent in BAJAJ/WIPRO/CROMPTON GREAVES/ LUKER
S&F LED post top luminaire, outdoor type (Prince opera midi) of 240 Volts, 50Hz, 40 watt capacity, IP 65 protection including mounting on 63mm dia galvanised medium grade pipe of 2.0 metre height from GL with necessasry PCC (1:2:4) type B1 foundation and connecting up with and including 3 core 2.5 Sq mm multistranded copper conductor cable drawn through 25 mm dia rigid PVC conduit from one light to other (Approx distance between two posts 30 metres) including taking down old unserviceable one complete all as specified and as directed. MAKE:CROMPTON GREAVES Cat part No. LPTO-40-CDL or equivalent in BAJAJ/ HAVELLS/PHILIPS
S&F Tube light fittings 2 feet mirror optical including all accessories and fixing arrangements complete all as specified and directed. Make : Philips Model No LED 48027/65/86 ultron/ CG Cat No LCL-14-CDL/Havells
S&F Tube light fittings LED 20 watts 4 feet including all accessories and fixing arrangements complete all as specified and directed Make :CG Cat Part No : CCS-100-20-65-HL2-DP-NWH/ Philips Cat Part No : Astra line plus/C&S/Havells
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F MCCB DB sheet steel enclosure, VTPN, 4-way, double door, 415 Volts with 200 Amps rated bus bar, IP-43 protection suitable for incoming MCCB 125 Amps and outgoing MCB TP/SP, enclosed in standard steel sheet flush mounting type, factory fabricated complete all as specified and as directed. MAKE: L&T/ LEGRAND/ SIEMENS/ INDO ASIAN/ HAVELLS
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCCB, 4 pole, 125 Amps, 16KA rupturing capacity, 415 Volts with thermal and magnetic release complete all as specified and as directed. Make : Havells/ L&T/ Indo Asian/ Legrand/Schneider
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/ L&T/ Indo Asian/ Legrand/Schneider
S&F MCB, SPN, "C" series, 240 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/Schneider
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 25 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 35 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
S&F FRP pole box of size 170x170x105mm consisting of 50 Amps, 4 pole connector - 1 No. and MCB, SP, 16 Amps, 10 KA - 1 No. with necessary clamps, bolts, nuts and washers including taking down old unserviceable one complete all as specified and as directed. MAKE: FRP Box: SINTEX Cat No. GS-JB-1414 or equivalent in Hansel MCB: L&T/ HAVELLS/ LEGRAND
S&F communication module for telephone socket, RJ 11 Make: Havells (Crabtree) ACAKRTW112/ Anchor/ Bajaj
S&F communication module for TV socket, Make: Havells (Crabtree) ACAKTOW000/ Anchor/ Bajaj
CHANDER SEKER ENTERPRISE
SHUBHAM SHANKAR GAIKWAD
SKV Engineering
M/s Bismi Builders & Enterprises
V KARTHICK
M/s Ramesh Lal
SUBASH FURNITURE SHOP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .