| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹5.8 L+₹85,002.60 (17.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest Tenderer | |
| 3 | L3₹6.1 L+₹1.1 L (21.6%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L3 | Rejected-Finance Other than lowest Tenderer | |
| 4 | L4₹6.9 L+₹1.9 L (37.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest Tenderer |
| Sl No | Description | Qty | Unit | KRISHNA ENGINEERING ENTERPRISES L2 | NATIONAL TRADING COMPANY L3 | MEELU ENTERPRISES L4 | narayan construction L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge. | 4 | Each | 11,000 ₹44,000 Lowest | 11,200 ₹44,800 | 13,500 ₹54,000 | 15,000 ₹60,000 |
| 2.00 | Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed. | 5 | Each | 3,400 ₹17,000 | 3,000 ₹15,000 | 2,500 ₹12,500 Lowest | 3,000 ₹15,000 |
| 3.00 | Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed. | 91.61 | Cum | 100 ₹9,161 | 200 ₹18,322 | 100 ₹9,161 | 80 ₹7,328.8 Lowest |
| 4.00 | All as per srl Item No. 3 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed | 0.32 | Cum | 100 ₹32 | 150 ₹48 | 100 ₹32 | 20 ₹6.4 Lowest |
| 5.00 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. | 43.3 | Cum | 10 ₹433 Lowest | 50 ₹2,165 | 50 ₹2,165 | 20 ₹866 |
| 6.00 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. | 48.63 | Cum | 10 ₹486.3 Lowest | 60 ₹2,917.8 | 50 ₹2,431.5 | 20 ₹972.6 |
| 7.00 | M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed. | 3.31 | Per 1000 Nos | 5,000 ₹16,550 | 4,500 ₹14,895 | 10,000 ₹33,100 | 3,000 ₹9,930 Lowest |
| 8.00 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. | 33.53 | Cum | 450 ₹15,088.5 | 600 ₹20,118 | 500 ₹16,765 | 280 ₹9,388.4 Lowest |
| 9.00 | XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified.
Note:-(Earth work, brick protection and sand cushioning shall be measured and paid for separately). | 50 | RM | 475 ₹23,750 | 350 ₹17,500 Lowest | 500 ₹25,000 | 500 ₹25,000 |
| 10.00 | All as per ser item No. 9.00 here in above but cross sectional area 70 sqmm 3.5 core | 60 | RM | 368 ₹22,080 | 300 ₹18,000 Lowest | 400 ₹24,000 | 300 ₹18,000 Lowest |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
26 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE(I) CIF(R) C/O 56 APO
REPAIR/ MAINT OF LT CABLE, LT OVERHEAD LINES, LT PANELS, STREET LIGHT AND CONNECTED WORKS AT 156 INF BN TA UNDER AGE(I) CIF (R).
2025_MES_710470_1
AGE(I)/R-24/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) CIF(R)
Class E and above and category b(i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,200
Yes
13 Aug 2025
27 May 2025
3 Jul 2025
27 May 2025
26 Jun 2025
11 Jun 2025
Amount
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed.
All as per srl Item No. 3 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking down old u/s cable, complete all as specified. Note:-(Earth work, brick protection and sand cushioning shall be measured and paid for separately).
All as per ser item No. 9.00 here in above but cross sectional area 70 sqmm 3.5 core
All as per ser item No. 9.00 here in above but cross sectional area 35 sqmm 3.5 core
All as per ser item No. 9.00 here in above but cross sectional area 25 sqmm 3.5 core
All as per ser item No. 9.00 here in above but cross sectional area 16 sqmm 4 core
All as per ser item No. 9.00 here in above but cross sectional area 16 sqmm 2 core
All as per ser item No. 9.00 here in above but cross sectional area 10 sqmm 2 core
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of pole around pole all as specified and as directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation of pole all as specified and as directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of pole around pole, stay assembly of pole and for road filling all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Energy saving, environment friendly, long life, exclusive innovative die-cast aluminium flood light with highly efficient IP- 66 LEDs as light source, suitable for highlighting architectural features or retail spaces of capacity 100 Watt completed with connection including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make : Cat No.GLOFLO/100W LTEFR100WHPLED of C&S or equivalent cat part of make as specified in list of make here-in-after.
Steel tubing galvanized (light grade) 80 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts including taking down old unseviceable cable and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
Steel tubing galvanized (light grade) 50 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts including taking down old unseviceable cable and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
Steel tubing galvanized (light grade) 40 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts including taking down old unseviceable cable and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
Steel tubing galvanized (light grade) 25 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts including taking down old unseviceable cable and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed.
S&F in replacement of alluminium cable thimbles of size 95 Sqmm UG Cable including complete connection and crimping, complete all as specified.
S&F in replacement of alluminium cable thimbles of size 70 Sqmm UG Cable including complete connection and crimping, complete all as specified.
S&F in replacement of alluminium cable thimbles of size 50 Sqmm UG Cable including complete connection and crimping, complete all as specified.
S&F in replacement of alluminium cable thimbles of size 35 Sqmm UG Cable including complete connection and crimping, complete all as specified.
S&F in replacement of alluminium cable thimbles of size 25 Sqmm UG Cable including complete connection and crimping, complete all as specified.
S&F in replacement of alluminium cable thimbles of size 16 Sqmm UG Cable including complete connection and crimping, complete all as specified.
S&F in replacement of alluminium cable thimbles of size 10 Sqmm UG Cable including complete connection and crimping, complete all as specified.
Detecting the fault of LT 440 volt overhead/ underground system of any feeder/location with necessary safety, testing equipment, tools and plants and rectify the defects on top priority basis/ as and when required including testing on completion, complete all as specified & directed.
Supply and fix in replacement of stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed. Note:-Excavation and concrete measured paid separately.
S&F in replacement of Off load change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge. Make: Havells cat ref No.IHCCFE0063 or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of Off load change over switch 63 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge. Make: Havells cat ref No.IHCCFE00100 or equivalent cat part of make as specified in list of make here-in-after.
Supply and fix in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and directed.
Supply and fix in replacement of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 1100 volt grade 75 x90 mm dia of bolt 12mm and section of straps 31x3mm, complete all as specifed and directed.
M&L for replacement of New Aluminium conductor, steel reinforced, of any size, type, fixed to poles and stretching properly drawn for overhead lines on poles including binding at site to insulator with suitable size of wire including 15mm dia PVC seperater at equal interval including removing old unserviceable ACSR conductor complete all as specified and directed.
M&L in replacement of 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 70 sq mm to 120 sqmm, complete all as specified and directed.
M&L in replacement of 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 25 sq mm to 50 sqmm, complete all as specified and directed.
M& L in repair to LT panel of any size/make by disconnecting all connections for incomming and outgoing cables and making alternate arrangement for power supply to the unit/Qtrs and repairing to LT panel by providing locking arrangement and hinges for doors through out the length of panel by cutting, welding, screwing of front panel, replacement of back cover and top cover made of CRCA steel sheet of size not less than 3.15mm thick, incl replacement of old rusted angle iron work and fixing/ fabrication of angle iron frame 40x40x5mm thick for LT Panel complete with painting of LT Panel Indoor/Outdoor type with spray gun with two coats of synthetic enamel heat resistant grey paint matching with existing all as directed by Engr-in-Charge.
S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 400 Amps,complete all as specified and as directed.
S&F for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed by the Engineer-in-charge.
All as per item no.43 here-in-before but rating 63 amp & breaking capacity 16KA
All as per item no.43 here-in-before but rating 160 amp & breaking capacity 36KA
All as per item no.43 here-in-before but rating 250 amp & breaking capacity 36KA
All as per item no.43 here-in-before but rating 200 amp & breaking capacity 36KA
All as per item no.43 here-in-before but rating 400 amp & breaking capacity 36KA
Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer fixed "as in repairs", complete all as specified and directed .
Supply and fixing in replacement of loop type insulator Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm suitable for stay assembly complete all as specified and directed.
Restringing of existing over head sagged conductor over head lines on existing LT poles including providing binding wire, line taps , fixing of dispositioned insulators in position with nuts and bolts with washers etc.as required at site complete all as specified and directed. Note :- (i) Quoted rate shall be deem to included the cost of winding wire and replacement of insulator if damaged during restraining of conductor.
Supplying and fixing 1100 volts grade heavy duty 10 sqmm PVC insulated solid type aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core (2 core) cable flat or circular complete all as specified.
Supplying and fixing 1100 volts grade heavy duty 16 sqmm PVC insulated solid type aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core (2 core) cable flat or circular complete all as specified.
Supply and fix in replacement of 1.5 Sqmm three core multi stranded copper conductor (FRLSH) cable PVC insulated unsheathed cable 1100 volt grade conforming to IS-694 complete as specified and directed.
Cutting, trimming and vending tree branches along HT/LT over head lines span upto 35 mtr, after arranging electrical shutdown , including taking all precautions while working on lines using own T&P by the contractor complete all as specified and directed by Engineer-in-Charge. Note :- (i) Branches of trees shall be cut upto 3 metre from the outer conductor of OH line. (ii) Cutting/trimming of branches shall be done after obtaining necessary shut down in wirting by the Engineer-in-Charge to avoid any casualty.
Supply and Fix in replacemement of PVC separator four way suitable for LT over head lines all as specified and directed.
M&L for replacement of GI bracket for fixing of street light fittings bend to shape, made out of 40 mm dia GI pipe medium grade suitable for fixing of Light upto 1.2 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
S&F Junction box hot pressed moulded pole mounted SMC KIOSK box, water proof, fire retardant IP-54 of size 300 X 200X105 mm incl fixing of terminal connector and arrangement for incoming & outgoing cable glands, aluminium bus bar 4strips of 20x3mm for TPN on necessary epoxy base insulator and fixing of 6 Amps MCB, incl necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed.
S&F LED bollard light 9W IP66 luminaire having a cylindrical body placed on top. Ideal for architectural outdoor lighting, typically giving off light from the sides, suitable to illuminate walkways, steps or pathways including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable . Make : Cat No.BGBOL 1000 9W LED WH 5700K of Bajaj or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. of capacity 60 Watt including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make : Cat No.INDUS-E/60W LTESSE60WLED of C&S or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. of capacity 90 Watt including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate and taking down old unserviceable. Make : Cat No.INDUS-E/90W LTESSE90WLED of C&S or equivalent cat part of make as specified in list of make here-in-after.
S&F in replacement of New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source with toughened glass top cover. TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. of capacity 120 Watt including 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate including taking down old unserviceable. Make : Cat No.INDUS-E/120W LTESSE120WLED of C&S or equivalent cat part of make as specified in list of make here-in-after.
M&L for replacement of LED street light drivers of size 90 watt for existing model of LED fitting, complete all as specified & directed.
M&L for replacement of LED street light drivers of size 120/150 watt for existing model of LED fitting, complete all as specified & directed.
M&L for replacement of LED street light surge protector 5 KA 60/75 watt for existing model of LED fitting, complete all as specified & directed.
M&L for replacement of LED street light surge protector 10 KA 90/150 watt for existing model of LED fitting, complete all as specified & directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 45,474.00 during AOC Note:- Tenderers shall not quote for this Schedule
KRISHNA ENGINEERING ENTERPRISES (BID ID -3329633)
NATIONAL TRADING COMPANY (BID ID -3333233)
MEELU ENTERPRISES (BID ID -3329700)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .