Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.5 CrAccepted-AOC C O SHANKAR MARKET DIBRUGARH | DIBRUGARH | ₹1.5 Cr | L-1 | Accepted-AOC Awarded the work with due approval from TPC-1 |
| 2 | L-2₹1.8 Cr+₹29.1 L (19.4%)Rejected-Finance | ₹1.8 Cr+₹29.1 L (19.4%) | L-2 | Rejected-Finance L-2 bidder |
Tender Value
₹1.6 Cr
EMD Value
₹3.8 L
Closing Date
18 Nov 2019, 12:00 pmClosed
Oo CGM_PPD
Oo CGM_PPD Bijulee Bhawan
Remaining works for Panitola Naupukhuri SS with terminal equipment and reconstruction of 11KV line
2019_APDCL_14270_1
UDAY_17_18/FINS/PANITOLA
Open Tender
Electrical Works
Turn-key
210 days
Tinsukia
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,000
Yes
APDCL
₹3.8 L
Oo CGM_PPD Bijulee Bhawan
5 Mar 2020
27 Sept 2019
18 Nov 2019
27 Sept 2019
18 Nov 2019
2 Oct 2019
1 Oct 2019
(i) Remaining works of newly constructed 33/11KV sub-station at Panitola & Naupukhuri sub-station along with sending end equipments for Naupukhuri sub-station. (ii) Reconstruction of 11KV Industry feeder, Nahoroni feeder, Baruahula feeder, Panitola feeder (iii) Construction of 11KV composite feeder (Naupukhuri to St. Looks Hospital) under Tinsukia Electrical Circle, APDCL under UDAY 2017-18 Scheme on full turnkey mode.
Description of Work / Item(s)
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm as per direction.
Supply, fitting & fixing of GI Channel cross arm (75x40x6x2200) mm for cradle guard
Supply, Fitting & Fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply & erection of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply and erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply, fitting & fixing of 11 kV GOAB switch, 400A
Supply, fitting & fixing of HT stay set
Supply, fitting & fitting of HT Guy Insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI wire 8 SWG
Supply, fitting & fixing of Jointing sleeve for Raccoon
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Balance works for commissioning of 33 KV, 2x10 MVA Panitola SS under ADB Tr-3 within the jurisdiction of Tinsukia Electrical Division under Tinsukia Electrical Circle, APDCL (BOQ 3)
Balance works for commissioning of 33 KV, 2x10 MVA Napukhuri SS under ADB Tr-3 within the jurisdiction of Tinsukia Electrical Division under Tinsukia Electrical Circle, APDCL (BOQ 4)
Terminal Equipment at 132/33 KV Tinsukia GSS as sending end for 33/11 kV Napukhuri S/S. (BOQ 5)
Re-construction of 11 kV Industry Feeder originating from 33/11 kV Panitola S/S (BOQ 6)
Re-construction of 11 kV Nahoroni Feeder originating from 33/11 kV Panitola S/S (BOQ 7)
Re-construction of 11 kV Barauhula Feeder originating from 33/11 kV Panitola S/S (BOQ 8)
Re-construction of 11 KV Panitola Feeder originating from 33/11 kV Panitola S/S . (BOQ 9)
Re-construction of Composite line from Napukhuri to St. Luke Hospital (BOQ 10)
Description of Work / Item(s)
Supply and erection of 33KV Isolator with earth switch and GI mounting structure 800A
Supply and erection of 33KV Isolator without earth switch and with GI mounting structure 400A (station tx. and PT)
Supply and erection of 33KV 10KA LA (station transformer)
Supply and erection of 33KV 10KA LA with surge monitor and GI mounting structure
Supply ,fitting & fixing of 33KV/110V,1p PT with GI mounting structure and marshalling box (set comprising of three)
Supply and erection of 33/.433KV 100KVA Transformer
Supply, fitting fixing of Aluminium Lug, assorted size
Supply, fitting fixing of GI pipe 50 mm dia 3Mtr. Length
Supply, fitting & fixing of GI Strip 25x3 mm
Supply, fitting & fixing of 6 SWG GI wire for earthing
Supply, fitting & fixing of GI nuts and bolts with washer
Supply, fitting & fixing of 33 KV DO fuse 150 A
Supply, fitting & fixing of DTR cubicle for 100KVA DTRs (comprising of requisite MCCBs static TVM,CT, Volt meter,ammeter etc)
Supply, fitting & fixing of LT XLPE CABLE 3.5 core 120 sqmm (al) unarmoured
Supply, fitting & fixing of LT XLPE CABLE 3.5 core 25 sqmm (al) armoured
Supply, fitting & fitting of 110V 100AH maintainance free Battery Bank
Supply, fitting & fitting of Battery Charger suitable for 110V 100AH Battery Bank
Supply, fitting & fitting of 11KV 9KA LA (Station type)
Supply, fitting & fixing of 11KV 9KA LA (line type for feeder)
Supply, fitting & fixing of GOAB 400A
Supply, fitting & fixing of 11 KV XLPE cable, 1C, 630 sqmm
Supply, fitting & fixing of 11 KV XLPE cable, 1C, 240 sqmm
Supply, fitting & fixing of 11 KV Cable Kit for XLPE cable, 1C 630 sqmm (indoor)
Supply & fitting of 11 KV Cable Kit for XLPE cabel 1C, 630 sqmm (Outdoor)
Supply & fitting of 11 KV Cable Kit for XLPE cable, 1C 240 sqmm (outdoor)
Supply & fitting of 11 KV Cable Kit for XLPE cabel 1C, 630 sqmm (Indoor)
Supply & fitting of Control cable copper 10core x 2.5sqmm
Supply & fitting of Control cable copper 7 core x 2.5sqmm
Supply & fitting of Control cable copper 4 core x 2.5sqmm
Supply & fitting of Control cable copper 2 core x 2.5sqmm
Switchyard gravelling with 40 mm broken gravel 0.15 cm thickness
Construction of Cable Trenches for power cable including supply of all materials and labour as per specification and drawing
RCC foundation for Isolator
PCC foundation for CT, LA and PT
DTR Fencing as per REC Specicifiation complete with material and labour
Construction of Transformer Pad (for station transformer)
Materials as required for Switch yard lighting (complete with 6 nos. of 40W LED bulb with structure and accessories)
Description of Work / Item(s)
Supply and erection of 33KV VCB with GI mounting structure, 1250A
Supply and erection of33KV VCB with GI mounting structure, 800A
Supply and erection of33KV Isolator with earth switch and GI mounting structure 800A
Supply and erection of 33KV Isolator without earth switch and with GI mounting structure 400A (station tx. and PT)
Supply and erection of 33KV 10KA LA (station transformer)
Supply and erection of 33KV 10KA LA with surge monitor and GI mounting structure
Supply, fitting fixing of 33KV/110V,1p PT with GI mounting structure and marshalling box (set comprising of three)
Supply, fitting fixing of 33KV, 1ph CT with GI mounting structure and marshalling box, 400-200/5-5-5A (set comprising of three)
Supply, fitting & fixing of 33 kV C&R panel for feeder (numeric type with static TVM)
Supply, fitting & fixing of 11KV outdoor CT with GI mounting structure and marshalling box, 600-300/5-5-5A (set comprising of three)
Supply and erection of 33/.433KV 100KVA Transformer
Supply, fitting & fixing of Aluminium Lug, assorted size
Supply, fitting & fixing of GI pipe 50 mm dia 3Mtr. Length
Supply, fitting & fixing of GI Strip 25x3 mm
Supply, fitting & fixing of 6 SWG GI wire for earthing
Supply, fitting & fitting of GI nuts and bolts with washer
Supply, fitting & fitting of 33 KV DO fuse 150 A
Supply, fitting & fitting of DTR cubicle for 100KVA DTRs (comprising of requisite MCCBs static TVM,CT, V meter,ammeter etc)
Supply, fitting & fixing of LT XLPE CABLE 3.5 core 120 sqmm (al) unarmoured
Supply, fitting & fixing of LT XLPE CABLE 3.5 core 25 sqmm (al) armoured
Supply, fitting & fixing of 110V 100AH maintainance free Battery Bank
Supply, fitting & fixing of Battery Charger suitable for 110V 100AH Battery Bank
Supply and erection of 11KV 9KA LA (line type)
Supply and erection of 11KV 9KA LA (station type)
Supply & fitting of Control cable copper 10core x 2.5sqmm
Supply & fitting of Control cable copper 7 core x 2.5sqmm
Supply & fitting of Control cable copper 4 core x 2.5sqmm
Supply & fitting of Control cable copper 2 core x 2.5sqmm
Switchyard gravelling with 40 mm broken gravel 0.15 CM thickness
Construction of Cable Trenches for power cable including supply of all materials and labour as per specification and drawing
Existing cable trench cover
construction of fire wall between transformer
RCC foundation for VCB ( sets)
RCC foundation for Isolator ( sets)
PCC foundation for LA, CT & PT
DTR Fencing as per REC Specicifiation complete with material and labour
Construction of Transformer Pad (for station transformer)
Materials as required for Switch yard lighting (complete with 6 nos. of 40W LED bulb with structure and accessories)
Description of Work / Item(s)
Supply and erection of 33 KV Isolators with Earth blade and GI mounting structure
Supply and erection of 33 KV Single phase multi-core CT with GI mounting structure
Supply,fitting & fixing of MS Flat 50X6 mm
Supply ,fitting & fixing of GI Flat 25 X 6 mm for Riser
Supply ,fitting & fixing of 50mm dia, 3 Mtr. Long GI Pipe
Supply, fitting & fixing of PG Clamp for ACSR Wolf Conductor
Supply and erection of ACSR Wolf Conductor
Supply, fitting fixing of 33 KV porcelin Post Insulator
Installation of earthing system with ms flats 50X10mm (for earthing mat) with GI flat riser 25X6 mm ( for earthing conductor) and GI pipe 50 mm dia of length 3000 mm ( for earth Electrodes) including excavation of earth , welding etc as necessary.
Switchyard gravelling 0.15m thickness by 40 mm sized crushed stone.
Description of Work / Item(s)
Supply and erection of PSC Pole, 9.75 mtr long with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm as per direction.
Supply, Fitting & Fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply & erection of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply and erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply, fitting & fixing of C. I. Earth pipe 1.8 Mtr
Supply, fitting & fixing of 11 kV, 9 KA LA (line type)
Supply, fitting & fixing of 11 kV GOAB switch, 400A
Supply, fitting & fixing of 11 kV D.O fuse set
Supply, fitting & fixing of Hot dip G. I. wire , 6 SWG for earthing
Supply, fitting & fixing of HT stay set
Supply, fitting & fitting of HT Guy Insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Supply and erection of PSC Pole, 9.75 mtr long with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm as per direction.
Supply, Fitting & Fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply & erection of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply and erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply, fitting & fixing of C. I. Earth pipe 1.8 Mtr
Supply, fitting & fixing of 11 kV, 9 KA LA (line type)
Supply, fitting & fixing of 11 kV GOAB switch, 400A
Supply, fitting & fixing of 11 kV D.O fuse set
Supply, fitting & fixing of Hot dip G. I. wire , 6 SWG for earthing
Supply, fitting & fixing of HT stay set
Supply, fitting & fitting of HT Guy Insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Supply and erection of PSC Pole, 9.75 mtr long with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm as per direction.
Supply, Fitting & Fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply & erection of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply and erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply, fitting & fixing of 11 kV GOAB switch, 400A
Supply, fitting & fixing of 11 kV D.O fuse set
Supply, fitting & fixing of HT stay set
Supply, fitting & fitting of HT Guy Insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Description of Work / Item(s)
Supply and erection of PSC Pole, 9.75 mtr long with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm as per direction.
Supply, Fitting & Fixing of GI Angle cross arm (50x50x6) for cross bracing
Supply, fitting & fixing of GI 11 KV "T"-cross arm with angle size (50x50x6)mm
Supply & erection of 11 KV Disc insulator 70 kN, T&C (Polymeric)
Supply, fitting & fixing of H/W fittings for disc insulator T&C (70KN) tension type
Supply,fitting & fixing of 11 KV Polymeric pin insulator
Supply and erection of ACSR "Raccoon" conductor
Supply, fitting & fixing of Tension clamp for "Raccoon" conductor
Supply, fitting & fixing of 11 kV GOAB switch, 400A
Supply, fitting & fixing of 11 kV D.O fuse set
Supply, fitting & fixing of HT stay set
Supply, fitting & fitting of HT Guy Insulator
Supply, fitting & fitting of PG clamp, for "Racoon" (Alcon 81)
Supply, fitting & fitting of Danger plate HT
Supply, fitting & fixing of GI nuts and bolts (Assorted) with GI washer
Supply, fitting & fixing of Barbed wire
Supply, fitting & fixing of GI wire Stay wire , 7/10 SWG
Supply, fitting & fixing of GI pole clamp
Assam Electricals
Assam Electricals
Assam Electricals
Assam Electricals
Assam Electricals
SMARTECH ELECTRA
Assam Electricals
Assam Electricals
Assam Electricals
Assam Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .