Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.4 LAdmitted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L1 | Admitted-Finance | ||
| 2 | L2₹20.6 L+₹3.1 L (18.0%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹22.4 L+₹5.0 L (28.4%)Admitted-Finance NOT SPECIFIED | L3 | Admitted-Finance | ||
| 4 | L4₹22.5 L+₹5.1 L (29.0%)Admitted-Finance 50 3 S F ARJUN NAGAR NEW DELHI 110029 | SOUTH | DELHI | 110029 | L4 | Admitted-Finance |
Tender Value
₹27.5 L
EMD Value
₹54,913
Closing Date
2 Mar 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
MOEI and fans i/c compound light street light and RMO pump sets
2026_PWD_287591_1
107/EE (E)/PWD EMD South West/2025-26
Open Tender
Electrical Works
Percentage
365 days
works
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹54,913
10 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
Sub-Head- I (MOEI & fans.)
Routine Maintenance all electrical installation internal and external, compound light, electrical/pump panels and switch gears, pumps, provision of fans and fittings, lamps of all sizes etc repairing of panel board, street lights in all days i/c sunday & holidays etc as reqd.
Wireman- 1 No. (9 AM to 5 PM)
Khallasi - 1 No. (9 AM to 5 PM)
Sub-Head-II (Manitenace Material for day to day use)
Following material /electrical accessories shall be supply by agency suitable for existing different type switch box / fitting and existing man power shall be used for replacement on day-to-day maitenance works etc as required. (Labour already included in Item No. 1 o Sub Head - I : EI & FANS )
S.P. 5/6 amps, one way switch, piano type ISI marked
S.P. 15/16 amps, one way switch, piano type ISI marked
3 pin 5/6 amps socket outlet, piano type ISI marked
6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked
Bell push, piano type
Telephone Socket outlet piano type
T.V. Socket outlet piano type
Ceiling rose, 3 pin, 5 amps ISI marked
Call bell/ buzzer, single phase
3 mm thick phenolic laminated sheet i/c cutting of suitable size & fixing on existing switch board with fixing of all existing switch/socket/ Fan regulator.
6 to 32 Amp c Curve SP MCB, "C" curve, 10 kA breaking capacity
6 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity
6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
6 amps. to 32 amps. ratings , TPN MCB, “C” curve, 10 KA breaking capacity
63 A, rating, 2 pole RCCB, 30mA
40 amps TP MCB
63 A, rating, 4 pole RCCB, 30mA
3 pole MCCB, 100A, 16kA Ics=100% Icu and Operational Voltage 690V
3 pole MCCB, 250A, 25kA Ics=100% Icu and Operational Voltage 690V
4 pole MCCB,100A,30kA Ics=100% Icu and Operational Voltage 690V
Modular base & cover plate for 6 module
Modular base & cover plate for 8 module
Modular base & cover plate for 12 module
1.5 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
4.0 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
6.0 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
10 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
2.50 mF capacitor
Heavy Duty Steel Ceiling Fan Hook Attachment Clamp with Rubber, Nut Bolts & Locking Pins.
Mild steel 8 feet Ceiling fan Down rod .
Stepped type Modular Fan regulator (2 module)
Medium Step Fan Regulator piano type
Ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req 1200 mm sweep Ceiling fans 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Desert cooler 135/150 Ltr.
300 mm sweep heavy duty exhaust fans
Electronic driver (5W to 12W) LED fixture
Electronic driver (15W to 22W) LED fixture
Electronic driver (36W/40W to 70W/75W) LED fixture
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials. A) 70 watt
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector a) 12 -15 watt
Supply of LED Bulk Head fitting not more than 10 W, System efficacy not less than 100 lumens / watt, System output not less than 1000 lumens / watt, CRI>80 and CCT= 5500-6500K and IP-66 rated with aluminium die cast housing & frostrated glass diffuser complete as required.
600 mm long nominal size LED batten mirror light fitting made out with Aluminium die cast housing and Poly carbonate diffuser with all accessories having rating not more than 10 W, System Efficacy not less than 100 lm/W, lumens output not less than 1000, CRI >80 complete etc. as required.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a)36 watt
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.
Suppling of heavy duty 150 AH SMF battery for inverter i/c credit for old battery.
Suppling of heavy duty 100 AH SMF battery for inverter i/c credit for old battery.
Refilling of fire extinguisher of specified capacity, including complete discharge of the cylinder, repair or replacement of any damaged parts such as valve assembly, gauge, hose pipe, horn, handle, and other components along with testing, commissioning, and securely refixing the cylinder in its original position after refilling, affixing a suitable instruction label indicating the date of refilling and next due date with credit for dismantled material etc complete as reqd.
ABC type (9 Kg)
ABC type (6 Kg)
Dry Powder type of 50 Kg .Capacity
Sub-Head- III (Minor Repairs of EI, Compound Lighr & Pumps.)
Supply of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size way.
3 X 10 Sq.mm
3.5 X 35 Sq. mm
3.5 X 70 Sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in following way.
Upto 35 sq. mm (clamped with 1mm thick saddle on wall surface)
Upto 35 sq. mm (in the existing RCC/Hume/Metal pipe)
Above 35 sq. mm and upto 95 sq. mm (in the existing RCC/Hume/Metal pipe)
Upto 35 sq. mm (in the existing mansenary open duct)
Above 35 sq. mm and upto 95 sq. mm (in the existing Mansenary open duct)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (40 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
SITC of weather proof pole box made out of hot moulded SMC sheet with clamp /fastner neutral link strip, gland thimble and 1 No. 6 Amps SPMCB Complete with inter connection with copper wire, earthing (Box Size - 300mm x 200 mm x 105 mm)
Rewinding of 1200mm ceiling fan complete with super enemelled copper winding wire i/c varnishing backing testing commissioning and without returning of scrop copper wire etc. as reqd.
Rewinding of 300mm Exhaust fan complete with super enemelled copper winding wire i/c varnishing backing testing commissioning and with credit of scrap copper wire etc. as reqd.
Rewinding repair and servicing of following monoblock/Submersible pump set suitable for run 3 phase, 440-volt, 50 Hz AC supply i/c carriage (to and fro) testing, commissioning with credit of scrap copper wire etc. as required.
3/5 HP monoblock/ open submersibal pump set
3/5 HP submersible pump set
Withdrawing of all capacity submersible pump set with motor with GI pipes from the existing borewell with the help of chain pully block, tripod and supplying clamp i/c dismentalling of GI pipe lengths by opening the nut & bolts, stacking the same etc as reqd
Lowering of all capacity submersible pump set with motor with GI pipes from the existing borewell with the help of chain pully block, tripod and supplying clamp i/c dismentalling of GI pipe lengths by opening the nut & bolts, stacking the same etc as reqd
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, ainting etc. as required.
Complete Servicing of existing installed WTAC /STAC of 1.5 TR capacity AC i/c indoor & outdoor units, checking for unit, inspection, greasing, oiling etc i/c chemical cleaning of the condensing coil with high pressure pump changing the air filter, checking & tightening all electic connection, testing the machine etc as reqd.
Supplying & charging of M-22/R22/R-32/R-410A/R-134A gas in the exising WTAC / STAC/Water cooler of following capacity unit i/c pressure testing, flushing the system & gas charging complete etc as reqd.
Repair of damaged PCB of indoor and outdoor unit of 1.5 TR AC i/c tightening the loose connection, testing the machine etc complete as required.
Supplying and fixing of 1.5 TR capacity WTAC/ Split AC cooling coils i/c pressure testing after removing the leakage with brazing, flashing the system, vaccuming the system, checking & repairing nterconnection complete in all respect as required at site. i.c dismantled of old material etc. as reqd.
Supply & Replacement of 1.5 TR WTAC / STAC burnt out / defective copper condenser coil with new one of the same size and design suitable for 1.5 TR Split type AC Out Door unit i/c breezing the all-copper pipe with all distribution joint's and make sure the connections with capillary tube linking dryer duly proper etc. Nightrogen pressure testing, leak detections, vaccumizing the unit, complete as reqd. i/.c dismantled of old material etc. as reqd
Supplying & fixing of following capacity compressor in the existing WTAC / Split AC making copper pipe connection, brazong pressure testing and supplying and charging M-22/R-32/R-410A refrigerant gas charging i/c cutting the copper piping dismantling of the old compressor complete as reqd.
Compressor - 1.5 TR
Providing and fixing WTAC /STAC fan motor capcity 1/4 to 1/8 HP i/c dismantling the burnt out motor from the existing unit & fixing of new motor making cnnection, testing complete etc as reqd.
Supplying & fixing of copper refrigerant pipe of size 1/4", 1/2" or 5/8" (as per suitable existing) with insulation and copper wire 3core 80-20 (2.5 sqmm) i/c all connection in the existing AC units i/c dismantled as per reqd at site.
Routine & day to day maintenance of 3 Nos. 50/100 LPH RO system for 6 months at ITI Jaffarpur area with following scope :
1. Visit of technician/ Engineer once in a week and/ or on complaint within 24 hr, for RO system in presence of client representatives
2, Checking, testing & cleaning all parts of RO system with suitable cleaning material during the visit to keep entire system healthy and service chart submitted to department and client.
3. Repairing/ Replacement of all defective parts.
4. In case of any fault quickly inform to department and repair immediately.
5. Replacement of all consumable & non consumable items (labour only) like micron filter Spun Pre Filter Cartridge all type filter anti scalent chemical membrane, High Pressure pump, low pressure pump, dosing pump, necessary valve and plumbering and electrical item etc. as reqd. supplied by department. Visit as and when required.
Supply and replacement of following spare suitable for 50/100 LPH RO system i/c testing commissioning i/c dismantling & credit of old material etc. complete as reqd. (As is where is).
RO Membrane (75 GPD)
Pre/Post carbon filter
20” or (2 x 10”) Particulate /Sediment Filter
20” Pre Spun filter 5 micron
Pressure pump
Solenoid valve
SS tap for Water Cooler
SMPS Adoptor
Water level controller
TDS Adjustor
Comprehensive maintenance of 3 Nos. 150/200 Ltrs. Water cooler of make USHA/Aquaguard & routine servicing of the water cooler i/c gas charging capacitors, fan motor, thermoplast, freezer coil, cards and any other accessories in the water cooler etc. Complete as reqd. i/c replacement of all defective parts, including replacement of compressor & compressor of water cooler and excluding water cooler body.
Supplying, installation, testing & commissioning of submersible pump set of 5.0 HP/ 3.70 kW rating operating on 3-¢ 50 Hz A.C. supply having discharge of (740) LPM at a head of (10 to 43) meter, complete with PVC insulated PVC sheathed Flat submersible copper conductor cable of standard length and suitable for DOL/star delta starter, Delivery - 50 mm i/c lowering the same in existing bore well i/c providing GI nuts, bolts, washers, rubber gasket and connecting the pipe line and electrical cable with water proof joint, connection testing etc. as required.
Supplying, installation, testing & commissioning of openwell/ mono-submersible pump set of 3.0 HP/ 2.20 kW rating operating on 3-¢ 50 Hz A.C. supply having discharge of (450 to150) LPM at a head of (15 to 27) meter, complete with 3 x 4 sqmm. PVC insulated PVC sheathed Flat submersible copper conductor cable of standard length and suitable for DOL/star delta starter, Suction - 50, Delivery - 40 i/c lowering the same in existing sump/tank i/c providing GI nuts, bolts, washers, rubber gasket and connecting the pipe line and electrical cable with water proof joint, connection testing etc. as required.
Supplying, installation, testing & commissioning of mono-block pump set of 2.0 HP/ 1.5 kW rating operating on 1-¢ 50 Hz A.C. supply having discharge of (430-200) LPM at a head of (10.5 to 18) meter, complete with 3 x 4 sqmm. PVC insulated PVC sheathed Flat submersible copper conductor cable of standard length and suitable for DOL/star delta starter, Suction - 50, Delivery - 40 i/c lowering the same in existing sump/tank i/c providing GI nuts, bolts, washers, rubber gasket and connecting the pipe line and electrical cable with water proof joint, connection testing etc. as required.
Supplying and fixing of 3x4 sqmm flat submersible cable of copper conductor cable alongwith GI pipe line etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Providing and fixing folowing dia medium class G.I. pipes complete with G.I. fittings i/c threading etc comp as reqd.
40 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
40 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end)
40 mm nominal bore (Horizontal)
SH-IV:- Credit of Dismantled material
Less Credit cost for following old dismantled materials
WTAC/STAC fan motor
AC Copper refrigerant pipe associated
5 HP Submersible p/set
3 HP Open well mono block
2 HP Mono block
copper submersible cable
2.5 mfd condensers
5/6A/ 15/16A Switch/ Socket/ bell push/ 2 way switch
c' curve SP MCB 6-32A
6-32A DP MCB 'c' curve
63 A RCCB, 2 /4pole RCCB, 30 mA
6-32A TP MCB 'c' curve
6-32A TPN MCB 'c' curve
Call bell/ buzzer, single phase
MCCB 100 A
MCCB 250 A
1.5/4.0 sqmm. FRLS Copper conductor cable
6.0 sqmm. FRLS Copper conductor cable
Ceiling fan
LED Panel light 2x2 ft.
Exhaust Fan
Street light fittings /Post Top Lantern Fittings
LED Down lighter
LED Batten light
LED Bulk Head fitting
LED batten mirror light fitting
LED flood light
Modular base & cover plate for 1,2,3,4,5,6,7,8 & 12 module
Stepped type Modular Fan regulator (2 module)
Medium Step Fan Regulator piano type
36/40/70/75 W Electronic Choke/ electronic Driver
5/12/15/22 W Electronic Ballast/ electronic Driver
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.31 MB
BOQ_381139.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .