GE North Patiala
GE North Patiala Sangrur Road Patiala Mil Stn
COMPLETION OF INCOMPLETE ITEMS OF WORKS FOR SPECIAL REPAIRS TO UNSV MCB DISTRIBUTION BOARD AND INTERNAL WIRING WITH FITTING AND FIXTURES IN OFFRS MD ACCN NO B 74 TO B 86 AND B 118 IN OLD CANTT UNDER AGE EM GE NORTH PATIALA
2019_MES_298879_1
GE(N)/PAT-19/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
100 days
Patiala Mil Stn
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE NORTH Patiala
₹19,000
Yes
25 Jan 2020
18 Nov 2019
26 Dec 2019
18 Nov 2019
24 Dec 2019
4 Dec 2019
18 Nov 2019 - 3 Dec 2019
Amount
Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
Point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. Notes: (i) Switches socket and regulators, pressed steel terminal boxes & Top cover plate where required shall be measured and paid for separately. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth
All as per Sl item No 2.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
All as per Sl item No 2.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
All as per item No.2.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 1.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for switch socket combination 3 pin 15 amps on independent board
Switch piano, flush type, 5 amps, 240 V single pole, one way fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) all as specified
Switch piano, flush type, 15 amps, 240 V single pole, one way fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) all as specified
Socket outlet, 3 pin , 5 amps multipuporse, piano flush type, fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring)
Socket outlet, 2 in 1, having provision of 3 pin 5 Amps & 3 pin 15 Amps fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring)
Bell push, flush type, 6 Amps , single pole, one way fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring).
Ding Dong Bell, AC 230 volt, single pole complete fixed as in repair all as specified.
Ceiling rose, surface bakelite, 65x50mm with three terminals complete all as specified and directed.
Supply and Fix in replacement of electronic fan regulator stepped type, necessary connections with suitable copper cable including taking down of unserviceable existing all specified.
Supply only LED retrofit lamp B-22 holder base with polycarbonate body and alumiinuim heat sink Lamp warm white of 9 watt complete all as specified and directed. Make : Crompton Graeves Cat Part No.LED 9W-B22-CDL or equavalent in Philips / Bajaj / Wipro
Decorative LED batten 1 X 9/10 Watt, 2 ft long incl IP 20 linear LED lamp with decorative end caps and incl 3 core flexible wire 0.5 Sqmm copper cable all as specified & directed after taking down old unserviceable tube light fitting of any description complete all as specified and directed. Make : Crompton Greaves Cat Part No.LCTL-9-CDL or equavalent in Philips / Bajaj / Wipro
LED Bulk head luminaries polycarbonate body heat resistant prismatic glass cover with specially designed gasket including LED 1x10 watts SMD after taking down old unserviceable light fitting of any description complete all as specified and directed. Make : Crompton Greaves Cat Part NoLBHP-10-CDL or equavalent in Philips / Bajaj / Wipro
Taking down unserviceable building security light fitting of any size/type and supply and fixing of powder coated pressure die cast aluminium compact LED security light fitting of 25 watt with LED lamps including mounting arrangement i.e GI pipe of suitable size, clamps, nuts bolts complete all as specified & directed. Make : Crompton Greaves Cat Part No.LSTS-25-CDL or equavalent in Philips / Bajaj / Wipro
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLS PVC insulated flexible solid/multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 6 sq. mm main cable + 1 run of 4 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item.
Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497.
Taking down of old unserviceable iron box of any size from the wall and supply & fixing of 50cm X 50cm X 18cm deep box made out of 2mm thick MS sheet with double shutters hinged with locking/ventilation arrangements, holes drilled for cable entries all over a coat of red oxide primer including necessary civil work and match disturbed surface and colour wash as per existing surface complete all as directed by Engr-in-Charge
Load line distribution board SPN, 8 ways, 240 volts with 200 Amps standard bus bar of suitable size, double door, powder coated sheet metal enclosure fitted with bus bar din and neutral link, and provision for accessories such as Isolators and MCB (out going) with adjustable release complete fixed as in repair all as specified.
Load line distribution board TPN, Vertical 4 ways, double door, powder coated DB and provision for MCCB/MCBs including necessary earth bar and neutral link 200 Amp, and complete with provision of MCB (out going) with adjustable release complete fixed as in repair all as specified.
MCB, single pole & neutral (SPN)10 KA 240 volts 63 Amp capacity fixing in DB’s complete all as specified and directed.
MCB, single pole (SP) 10 KA 240 volts 5 to 32 Amp capacity fixing in DB’s complete all as specified and directed.
MCCB TPN, 100 Amps, 4 pole 415 volts, 16 Ka complete fixed as in repair all as specified and directed.
Taking out old serviceable/unserviceable LT UG cables of any size from trenches, poes/walls and floor including taking out old bricks from trenches complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable and foundation of poles/stays etc. not exceeding 10 Sqm area on plan and not exceeding 1.5m in depth and getting out in soft/loose soil, complete all as specified.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Clean dry sand laid in trenches/ ducts for bedding and cushioning to cable, including spreading and leveling complete all as specified.
Sub class ‘B’ old size bricks laid adjacent to each other perpendicular to the direction of cable in trenches for protection of cable all as specified.
Supplying, laying, jointing, testing and commissioning of XLPE insulated armoured electric power LT cable (heavy duty) with aluminium conductor 1100 Volts grade of cross sectional area 16 Sqmm 4 core complete laid on wall/pole complete all as specified and directed. Note : (i)Cable shall be laid in trenches, under road, across the nallahs, along pole/wall and in ducts. (ii) Excavation & earth work, pipe, clamp, sand cushioning and cable protection shall be measured separately.
GI tube light grade (ISI marked) 40mm bore laid in trenches across road/nallah or fixed along with wall/pole including two clamp, 2 Nos FI of 40 x 6mm size with nuts, bolts and washers or laid in floors complete fixed as in repair for cable protection complete all as specified and directed.
M/S RAJ KUMAR GUPTA
M/s Amit Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .