| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | ₹1.9 Cr Quoted ₹2.0 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.0 Cr+₹14,572 (0.07%)Rejected-Finance 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | ₹2.0 Cr+₹14,572 (0.07%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹2.0 Cr+₹6.2 L (3.15%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹2.0 Cr+₹6.2 L (3.15%) | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹2.3 Cr+₹29.8 L (15.0%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹2.3 Cr+₹29.8 L (15.0%) | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹2.4 Cr+₹37.2 L (18.8%)Rejected-Finance | ₹2.4 Cr+₹37.2 L (18.8%) | L5 | Rejected-Finance Being not lowest |
Tender Value
₹2.0 Cr
EMD Value
₹2.8 L
Closing Date
15 May 2023, 6:00 pmClosed
CE (AF) GANDHINAGAR
HQ CE (AF) GANDHINAGAR , LEKHAWADA PATIA, CHILODA, GANDHINAGAR
AADN ALTN IMPROVEMENT OF WATER SUPPLY INFRASTRUCTURE AND ASSOCIATED WORKS AT AIR FORCE SATION UTARLAI
2023_MES_585303_1
82363
Open Tender
Civil Works - Water Works
Lump-sum
365 days
GE (AF) UTARLAI
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) UTARLAI
₹2.8 L
Yes
26 Jun 2023
10 Mar 2023
18 May 2023
10 Mar 2023
15 May 2023
30 Apr 2023
10 Mar 2023 - 31 Mar 2023
Amount
NOTE: Schedule ‘A’ Part I to VI are under Ser No. 1.00 to 6.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Hard Standing as listed in Sch `A’ Part III
Lump sum price worked out for Security Fencing as listed in Sch `A’ Part IV
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part V
Lump sum price worked out for External Electrification as listed in Sch `A’ Part VI
SCHEDULE 'A' PART - VII is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
EXTERNAL WATER SUPPLY
Supply and fixing of CI sluice valve 350mm dia bore size, with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.6 including disconnection and removing the unserviceable sluice valves from the existing pipe line/valve chamber complete all as specified and directed .
Supply and fixing of Float and Board Level Gauge of following Specifications complete all as specified and directed :- Gauge Board : Aluminium Powder coated, Float: diameter 300mm SS. 316, Wire: SS 316, Flange: 1″ asa 150 M.S. powder coated, Pulley : PP pulley enclosure: M.S. powder coated, Telescopic pipe: 500mm M.S. powder coated, Pointer: triangular M.S. powder coated, Density : ≥0.8 g/cm3, Max. Temp : 100°C, Max. Pressure : Atm APPLICATIONS Non Pressurized Bulk Storage Tanks & Sumps
Supply, Installation Testing & Commissioning of Outdoor type PLC (Programmable Logic Controller) based Pump & Valve Automation, Protection Panel suitable for control and monitoring of 02 Nos. openwell Pumps, 02 Nos. Motorized Butterfly Valves, 02 Nos. Flow Switch. The panel should be of minimum size 1100(H) X 1000(W) X 300(D) mm fabricated from 3 mm CRCA Sheet having Canopy and Double Door for weather protection The Panel should comprise the following items:- (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps (e) Auto Change Over In Case of Pump Failure (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves & pumps) from the PLC based Control Panel. (ii) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER /SIEMENS /ABB /GE Automation / PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom build function blocks.
Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/ Tricolite/ GE Automation) Supply, Installation, Testing, Commissioning 1 KVA UPS / INVERTER with Sealed Lead Acid Maintenanace free Batteries for powering the panel for a minimum of 15 minutes in case of supply failure. UPS should have following features:- Battery Type: - Sealed Lead-acid Display:- LED Display Audible Alarm:- Battery Mode, Low Battery, Overload, UPS Fault. (Make: CYBERPOWER / TATA LIEBERT / NUMERIC) (A).Soft starter 02 Nos suitable for the submersible pump as per item No. 10 (B) Preventing device /control for the safe guardof dry run of motor, motor should never run in dry condition (C) Suitable size voltmeter and Ammeter should be included in the panel Note : All other parts required for the operation of openwell submersible motor deemedto be included in this panel.
Supply, installation, testing and commissioning of submersible pumpset of 10 HP suitable for UG sump with fixing and lifting arrangement from sump, having discharge capacity of 750 L/min to 1500 L/min, Head range 18m to 34 m, including submersible copper cable of 6 sqmm 3 core from starter to motor with GI pipe 40 mm light grade for ground portion only complete as specified and directed.
Material and labour for the following sizes Ductile iron pipe, spigot and socket ends, class "K-9" with rubber gasket (tighten joint) , laid in trenches including necessary cut to length to match the existing fitting/pipes or insertion of new DI specials complete all as specified and directed :- Note: Excavation & earth work, DI specials shall be measured and paid seperately
100 mm bore
150 mm bore
80 mm bore
Supply and fixing of CI sluice valve of dia 150 mm size with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.6 including disconnection and removing the unserviceable sluice valves from the existing pipe line/ valve chamber for complete all as specified and directed
Supply and fixing of CI sluice valve of dia 100 mm size with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.6 including disconnection and removing the unserviceable sluice valves from the existing pipe line/ valve chamber for complete all as specified and directed
Supply and fixing of CI sluice valve of dia 80 mm size with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.6 including disconnection and removing the unserviceable sluice valves from the existing pipe line/ valve chamber for complete all as specified and directed
Supply and fixing of Cast Iron Air Valves with two air Outlets, 150 mm dia bore and fixing Up in by cutting of existing pipe line with suitable fixing arrangement or at new laid pipe water supply mains as per IS complete all as specified and directed
Supply and fixing of Cast Iron Air Valves with two air Outlets, 100 mm dia bore and fixing Up in by cutting of existing pipe line with suitable fixing arrangement or at new laid pipe water supply mains as per IS complete all as specified and directed
Supply and fixing of Cast Iron Air Valves with two air Outlets, 80 mm dia bore and fixing Up in by cutting of existing pipe line with suitable fixing arrangement or at new laid pipe water supply mains as per IS complete all as specified and directed
Note for Item No.15 to 17:- (i) DI special will be measured and paid separately. (ii) Rate quoted shall include the cost of dewatering of water accumulated while cutting of existing pipe line (iii) Earth work will be measured and paid under respective item
M & L for valve pit chamber 1000 x 1000 x 1000 mm (Internal dimensions) with PCC block masonary valve chamber, PCC foundation, plastering and necessary earth work in any type of soil, MS sheet cover 3.15 mm thickness along with angle iron frame of size 40 x 40 x 6mm with locking arrangement with necessary fixing materials like hinges, nut/bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc complete all as specified and directed
M&L for tibba sand cushioning for underground cable using fine sand 8cm before laying cable and 15cm after laying and punned to 180mm after laying of cable complete all as specified. (Note: Punned thickness shall measured and considered for payment purpose)
M & L for boring of holes 150mm dia under pavement using ultra sound technique and necessary machine complete all as directed .
Taking up or down steel water tubing or CI/DI pipe line including connections - joints for removal of unserviceable water pipe lines complete all as specified and directed for the following sizes of pipes :- Note: Excavation shall not be measured and paid again if the new pipe line is laid in same trench.
150mm bore
100mm bore
80mm bore
50mm bore
Material and labour for CI/DI specials such as bends, tees, collars, tail pieces, straight/angle connecting pieces any type (flanged ends, socketed ends or flanged/socketed ends) complete suitable for CI/DI mains of sizes upto 300 mm complete all as specified and directed.
M & L for cutting of road / path for laying of GI / DI pipes upto required width and requried depth n.exc 1.5 mtr complete all as specified and directed.
M&L Cable route indicator made of of cast iron 10 cm dia and 6mm thick with embossing “MES LT Cables" backside welded on the angle iron 40mm x 40mm x5mm, 0.9 m long (0.4m embeded in PCC ) above the cable and with PCC1:2:4 150mm x 150mm x 600mm including painting with two coats of enamel paint and one coat of red oxide primer complete all as specified and directed.
DG Set
Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors net of not less than 40 KVA /32 KWe, 50Hz 415 volt 3 phase, 4 wire, 0.8 lagg, 51 hp minimum Required Power for Rated kVA (hp) along with AMF system with Acoustic Enclosure exhaust silencer Critical Grade in line, as per the noise emmission standards liad down by MoEF / CPCB Norms, along with Emission control device along with acessories, supporting brackets as per central pollution control Board / national green tribunal / Min of Environment, Forest and climate change
A) Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM such as Cummins/Perkins/Kohler/Greaves/Ashok Leyland Engines for powered diesel generator set along with these specifications of Advanced in-cylinder technology turbo charged , air cooled aspriated to meet latest emission norms without any after-treatment device. Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly powe Compact in size with optimum power to weight ratio, 4 cylinder, In-line 4 stroke, radiator cooled engine Well designed air handling system with Dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, Air to air aftercooling, Optimised turbocharger for increased altitude capabilities, Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter, Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature, Full flow spin on lube oil filte, First fill of lube oil and coolant, Electrical starter motor with soft start engagement feature, Battery charging alternator, 1 x 12 V DC battery/Alternator
B) Alternator PMG type comprising of the following: Stamford UC/Jyothi/Crompton alternator frames from Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-13 Phase reconnectable winding with 12 terminals brought out for connection Dedicated winding specially designed for 1 phase and 3 phase operation Better motor starting capability Best in class efficiency Compact design with sealed bearings for longer life and lesser maintenance Impregnation on all wound components for better mechanical strength Voltage regulation (Max.)±1%,Class of Insulation H Class, Winding Pitch 2/3, Stator Winding Double layer lap Rotor Dynamically Balanced,Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %,Maximum Unbalanced Load across phases# less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capacity net output shall not be less than 40 KVA /32 KWe, 50Hz 415 volt 3 phase, 4 wire, 0.8 lagg. 56 Amp / phase
c) Control Panel comprising of the following: AMF / Control panel is manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish.The control panel shall consists of the following parts of makes as per OEM recomendation : Microprocessor based generator set monitoring and control system. AMF Functionality inbuilt and this control shall include an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’, Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and shortcircuit protections.along with motorised change over swich for auto/manual operations along with control contactors with copper busbars, cables and protective acessories with load / bypass arrangements
Critical Grade silencer Critical grade silencer with Rain Cap suitably optimized to meet stringent noise emission standards laid down by MoEF / CPC Balong with MS supporting structures .along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
d) Controller should be compatable to the following specifications: (i)AMF Functionality controllers of Makes from the OEM : Deep Sea/ Cummins/ Wood Ward/ Com Amp (ii) Intuitive operator interface which includes LED backlit 128X64 pixel graphic display with tactile feel soft-switches Indications - Generator set, Utility Status Lamp. (iii) Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours (iv) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. kwh, Total & per phase (kw & kVA), PF, Utility Voltage and Freq. (v) Engine Protection: Low lube oil pressure, High/Low coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level.
(vi)AC Alternator Protection: Over/Under Voltage, Over/ Under Frequency, Loss of AC sensing. Overspeed, Over Current. (vii)Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii)Configurable glow plug control, Cycle Cranking (ix)12/24 Volt DC operation,Sleep mode,Modbus interface (RS485 RTU), In Power compatible (PC based service tool), Certifications - meets the requirement of relevant ISO, EN,Mil Std. and CE standards (e)Maintenance due alarm based on Engine Run Time and due date,Exercisor scheduler (f) Remote HMI, Digital electronic governor with temperture compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring
(e) All pipe line connections, valves etc.required for the lube oils, fuel and cooling system (f) Battery & Battery charger of rated capacity as per the alternator/ Engine compatability (g) Mounting Arrangement shall be of the following: (i) Engine and alternator mounted on a common MS fabricated base frame with AVM pads. (ii) Base frame with integral fuel tank provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning
(h) Fuel Tank of capacity 90 ltr along with Fuel pipe MS c class 25mm ID with bends, flanges, valves, tees and bends. (j) Control / service cables shall be of 4c x 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables, pvc insulated copper armoured, control panel for auxilaries with starters for pumps,heaters etc
(k) RCC foundation with necessary earth work, PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work / TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips, 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cement / Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions
(l) Acoustic Enclosure shall comprise of the following (i)Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions (ii)The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base frame painted in black or any other standard colour as specified by the OEM (iii) High quality noise absorbant and fire-retardant grade acoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv)Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v)11 tank pretreatment process and UV resistant powdercoating of all parts to with stand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling arrangement inside the enclosure
(J) Emission controll device along with acessories, supporting brackets as per central pollution control Board / national green tribunal / Min of Environment, Forest and climate change The Emissions shall be under the Prescribed Limits. Power Category more than 19Kw to 75 KW, Emission Limits (g/KW-hr), NOx+NMHC or NOx+RHC < or = 4.7 CO < or =3.5
Note for Item No.25 (i) Rate quoted shall include the necessary T&P , RCC foundation, structural works required to support the acessoriess of DG set such as AMF panels, controll cables, Radiators / cooling tower, Exhaust mufflers and water circualtion system / cooling System (ii) Rate quoted includes the cost of All fuel ( high speed diesel) , lubes and collant required to carry out the no load and full load test of not less than 24 hrs as diercted by the Accepting officer (iii) Rate quoted includes the cost of B check for the DG set such as replacement of lube oil, oil/ fuel filters /belts, O rings consumeables after the test run of the DG set during the warrenty period frist 250 hrs/ 1 st year which ever is earlier after the date of commissioning
Sch of credit Rs 993340.00
SHREE BALAJI TRADING CORPORATION
Anil Builders
M/s godara infratech and power industries
M/S JIWAN KUMAR MITTAL
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .