Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.4 L+₹73,306.50 (2.75%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹31.7 L+₹5.0 L (18.7%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹31.8 L+₹5.1 L (19.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Sept 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair/Maintenance and Replacement of U/S LT UG cables ,Feeder Pillars, Panels, LT Poles, O/H Conductor, Earthings, Voltage Stabilizers, UPS , LT Poles, Voltage stabilizers, UPS and connected works at CPH area under GE Utilities Udhampur
2020_MES_368273_1
GE/U-53/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹70,000
Yes
7 Nov 2020
11 Aug 2020
16 Sept 2020
11 Aug 2020
14 Sept 2020
31 Aug 2020
Amount
Taking out the existing unserviceable rusted LT panel board alongwith bus bar, MCCBs etc of any size/capacity including disconnection, dismantling PCC foundation etc and disposed off complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of out door type, weather proof, cubical panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gasket etc for natural air flow of capacity suitable for 3 phase 4 wire 415 volts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments: -
Outgoing: - (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Note: - (i) Rates quoted by the contractor shall be deemed to include for:- (a) Connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (b) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed by Engineer-in-Charge.
Taking out the existing unserviceable rusted bus bar panel board alongwith busbar with parts of any size/capacity including disconnection, dismantling PCC foundation etc and disposed off complete all as specified and directed by Engr-in-Charge.
M&L for factory made sheet metal enclouser (junction box) made out of 14 SWG CRCA sheet powder coated weather proof outdoor type with 60 cm long legs 4 Nos made out of 40X40X6 mm equal angle size of enclosure not less than 75X60X30 cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 400 amps suitable of one incoming and 5 outgoing feeders, mounted on insulators including disconnection of cable from the brunt bus bar and reconnection of cable from the brunt bus bar and reconnection in the new chamber with nuts and bolts including lugs of suitable sizes, necessary earth work and PCC foundation for grouting of four legs all as per existing complete all as specified and directed by Engr-in-Charge.
Disconnecting/taking out existing unserviceable / damaged LT underground cable of size 400 sqmm 3.5 core from trenches /ducts or from to poles/walls or under roads /paths/drains/culverts and disposed off complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 5.00 here-in-before but size of 300 Sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 240 Sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 185 Sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 120 Sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 95 Sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 70 sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 50 sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 35 Sqmm 3.5 Core.
Description all as per serial item No 5.00 here-in-before but size of 16 Sqmm 4 Core.
Supplying, laying, jointing and testing LT underground cable pf size 400 sqmm 3.5 Core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Note: - GI Tubing and earth work shall be measured and paid seperately under respective item of Sch 'A'.
Description all as per serial item No 15.00 here-in-before but size of 300 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 240 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 185 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 120 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 95 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 70 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 50 sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 35 Sqmm 3.5 Core.
Description all as per serial item No 15.00 here-in-before but size of 16 Sqmm 4.0 Core.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wid and not xceeding 1.5 m deep for foundations of poles/stays etc not exc 10sqm area on plan and getting out in solft/loose soil complete all as specified and as directed by Engr in Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: - For payment purpose 18 cm thickness shall measured.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-Charge.
S&F in replacement of tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/ nuts/washers or laid in floors/under roads of size 80 mm bore complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 31.00 here-in-before but of size 50 mm bore.
Description all as per serial item No 31.00 here-in-before but of size 40 mm bore.
M&L for cutting of existing road for crossing of underground electric cable through GI tubing of any size including necessary excavation and earth work, repairing/making goods the disturbed surfaces as per existing pre mix bituminous carpet complete all as specified and directed by Engr-in-Charge.
M&L for replacement of earthing with GI earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
M&L earthing with galvanized M.S. earth plate of size 600x600x6 mm thickness earth plate directly buried in ground vertically in a depth of not less than 1.5 mtr below the ground level with adequate quality of salt and charcoal packed thickness not less than 15 cm on all sides of earth plate excavation and earth work in soft/loose returning filing in removed of surplus soil including GI earth wire of 4 mm soldered and riveted to earth plate at one end and connected to equipment/machinery/pole at the other end and GI wire enceased in and including 15 mm bore GI light grade tubing with all fittings from earth plate up to equipment panel board including clamp, bolts, nuts, washers and providing 20 mm dia GI pipe light grade for watering, including PCC chamber with funnel as per SSR Pt - I Electrical plate No 5. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge
M&L for Mild steel, plain, black sheet 1.6 mm thick in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as required complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new or previously untreated surface and Painting the exposed surfaces of Panels with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
S&F straight through joint kit, heat shrinkable type suitable for 25 to 35 Sqmm LT underground cable complete all as specified and directed by Engr-in-Charge.
S&F straight through joint kit, heat shrinkable type suitable for 50 Sqmm to 95 sqmm LT underground cable complete all as specified and directed by Engr-in-Charge.
S&F straight through joint kit, heat shrinkable type suitable for 120 to 185 Sqmm LT underground cable complete all as specified and directed by Engr-in-Charge.
S&F straight through joint kit, heat shrinkable type suitable for 240 Sqmm to 300 sqmm LT underground cable complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=75%Icu- 35/36 KA, 415 Volts, 800 Amps , with adjustable thermal and magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 630 Amps , with adjustable thermal and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
M&L for aluminium thimble (Lugs) in replacement suitable for Cable of size 25 Sqmm complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 50.00 here-in-before but for cable of size 35 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 50 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 70 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 95 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 120 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 150 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 185 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 240 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 300 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of size 400 Sqmm.
Description all as per serial item No 50.00 here-in-before but for cable of of size 630 Sqmm.
Opening, maintenance and general servicing of Servo voltage stablizers of different makes (Rating from 100 KVA to 400 KVA) including removal of sludge from disserstate coils, Buck Boost Transfromers, tightening of all nut bolts, cleaning of stablizer coils, checking and servicing of servo mechanism, gear synchronising system, automatice voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Servo Motor with RC Net work having torque of 3 Kg/cm as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Servo Motor with RC Net work having torque of 10 Kg/cm as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electronic Control Card for Automatic Voltage regulation as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of wiring of Electronic Control panel complete all as specified and directed by Engr-in-Charge.
M&L for top up of transformer oil (ISI Marked) suitable for existing voltage stablizer as per IS 335 part-1 complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Auto/Manual switch for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of main indicators for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of micro press switch for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of voltmeter of capacity 0-300 volt for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of voltmeter of capacity 0-500 volt for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Ammmeter CT operated for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of carbon Brushes of capacity 50 KVA-100 KVA for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of carbon Brushes of capacity 100 KVA-400 KVA for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of variac coil conforming to the original specifications of the servo stablizer of any make/capacity with super enamelled copper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete all as specified and directed by Engr-in-Charge.
S&F in replacement of circuit plate of capacity 100 KVA-400 KVA for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of push button of capacity 100 KVA-400 KVA for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of pulse transformer of capacity 100 KVA-400 KVA for voltage stablizer of any capacity and size as per existing make complete all as specified and directed by Engr-in-Charge.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service conncetions one twin core 10 Sqmm cable flat or round complete all as specified and directed by Engr-in-Charge.
Dismantling of unserviceable steel tubular swaged pole/ PCC pole complete with accessories complete all as specified and directed by Engr-in-Charge.
Dismantling of unserviceable ACSR conductor of any size from existing over head lines complete all as specified and directed by Engr-in-Charge.
Dismantling of GI earth wire and guard wire from existing OH lines complete all as specified and directed by Engr-in-Charge.
Dismantling of cross arms, MS channel or angle section complete with all accessories viz nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge.
Dismantling of unserviceable stay assembly complete with all accessories complete all as specified and directed by Engr-in-Charge.
S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engr-in-Charge. Note: - The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
M&L for ACSR conductor of required size for Over head lines on poles including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor complete all as specified and directed by Engr-in-Charge.
M&L for guard cradles made to shape hexagonal rectangular or any other shape as required and fabricated out of galvanized steel wire 8 SWG (4mm dia) including binding wire of suitable size complete all as specified and directed by Engr-in-Charge.
S&F continuous earth wire GI 4mm dia for continuos pole earthing including fixing on cross arms complete all as specified and directed by Engr-in-Charge.
M&L for cross arms of any sizes with drilled hole (hot and cold etc) in position M.S. work including MS nut and bolts, washers and two coats of aluminium paint over one coat of redoxide primer complete all as specified and directed by Engr-in-Charge.
S&F stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I complete all as specified and directed by Engr-in-Charge.
Taking down carefully old UNSV insulator of any type/size from existing over head lines complete all as specified and directed by Engr-in-Charge.
S&F insulator pin type porcelain viterous white, brown or green LT 1100 Volt including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised iron nut of size 100mm x 65mm all as specified and directedby Engineer-in-Charge.
S&F shackle type insulator pocelain viterous LT 1100 Volt 100x115mm including M.S. strip washers, insulator bolts, nuts complete all as specified and directed by Engr-in-Charge.
M&L for Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same complete all as specified and directed by Engr-in-Charge.
Dismantling re-errecting, restringing, tensioning and repair to overhead line ACSR conductor any size upto 5 conductor in one span as required on poles LT / HT including fixing insulators and jointing with ACSR conductor complete all as specified and directed by Engr-in-Charge.
M&L for painting to steel tubular swaged pole of Overhead lines (9 Mtr long) including MS angle,channel,clamp etc.complete with and including comprising the following works: Note: - (a) Scraping out wornout old paint and making the surface smooth complete all as specified and directed by Engr-in-Charge. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) complete all as specified and directed by Engr-in-Charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engg.-in-charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specified and directed by Engr-in-Charge.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed by Engr-in-Charge. Note: - (a) The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b) Prooning of all tree branches in one tree shall be measured as one Job. (c) Contractor will employ sufficient labour to complete the job with in time as directed. (d) Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply. However full assistance will be provided by MES staff. (f) The contractor will provide proper tools and safety devices to his staff for prooning of trees.
M&L plain cement concrete 1:3:6 type D-2 as in foundations filling and mass concrete using 40mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
M&L plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for coping of poles incl all necessary form work complete all as specified and directed by Engr-in-Charge.
MOHAN LAL AND SONS
FANGALIA TRADERS
PREM NATH KHAJURIA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .