Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹4.8 L+₹7,305.43 (1.56%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹4.8 L+₹10,005.43 (2.13%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹4.8 L+₹15,695.14 (3.35%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹4.6 L
Closing Date
4 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (E) Agra
62 Taj Road, Gwl House Agra Cantt
Execution of Job Work
2020_MES_407660_1
3004/E-Qtn/63/2020-21/E3
Limited
Job Works
Item Rate
30 days
Agra
As per tender documents
2 documents required · 2 mandatory
₹0
Exempted
20 Jan 2021
29 Dec 2020
6 Jan 2021
29 Dec 2020
4 Jan 2021
29 Dec 2020
60 days
Amount
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 mtr long including one coat of red oxide primer and two of aluminium paint all as specified & directed.
Supply and lay in trenches/fixed to walls/poles etc and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100 volts grade with strandede aluminium conductor of size 120 Sqmm 3.5 core and all as directed and specified.
Supply and fixing in replacement MCCB having current ratings 630 Amps with rupturing capacity 50 KA , AC 415 Volts, 4 poles with thermal Magnetic release complete with spreader links all as specified and directed including dismantling the existing U/S MCCBs with all connections & all as required at site or directed by Engr -in - Charge. Make : Legrand CAt Part No 4220 23 DPX 630 or equivalent of L&T/C&S/ABB/Siemens
Supply and fixing in replacement MCCB having current ratings 400 Amps with rupturing capacity 50 KA , AC 415 Volts, 4 poles with thermal Magnetic release complete with spreader links all as specified and directed including dismantling the existing U/S MCCBs with all connections & all as required at site or directed by Engr -in - Charge. Make : Legrand CAt Part No 4220 21 DPX 630 or equivalent of L&T/C&S/ABB/Siemens
Supply and laying 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core and all as directed and specified.
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2 x 2.5 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay
Exc in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles/cable, stay assy etc. and getting out in any type of soil complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15 cm above the cable and punned to 18 cm as cable cushioning and covering all as directed. Note:- Punned quantity will be measured paid at this item.
S & L brick covering with width equal to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed.
M&L for cement concrete 1:3:6 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc.
Note: Old material obtained shall be handed over to the contractor and a sum of Rs 7400.00 shall be recovered from him as Sch of credit. Contractor shall quote the rate accordingly.
M/s KCL Engines and Machines
Mahendra Enterprises
Gupta Automobiles
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_455181.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .