Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹31.5 L+₹1.8 L (5.94%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L2 | Rejected-Finance Rejected not being Lowest | |
| 3 | L3₹31.6 L+₹1.8 L (6.14%)Rejected-Finance | L3 | Rejected-Finance Rejected not being Lowest | |
| 4 | L4₹35.7 L+₹6.0 L (20.1%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance Rejected not being Lowest | |
| 5 | L5₹36.2 L+₹6.4 L (21.6%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L5 | Rejected-Finance Rejected not being Lowest |
| Sl No | Description | Qty | Unit | Commercial Traders L1 | mayur enterprises L2 | MV Engineers And Contractors L5 | M/s JAIMAA ASSOCIATES L3 | Vijay Electricals L4 | Tushar engineers L7 | Ruchi enterprises L6 | M P TYAGI ENGINEERS AND CONTRACTORS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fixing of LT panel board suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of controlling ACB/MCCB capacity with colour insulating tape / sleeves mounted on suitable size "F" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and accessories inside complete all as specified and directed by Engr-in-Charge :-
Incoming :- (i) ACB 4 pole 2000 Amp, 50KA,Micro processor released manual drawout Adjustable type - 02 No. (ii) 4 Pole Aluminium Bus Bar 3000 Amp
(iii) Digital type 3 Ph multifunctioning meter to measure Amp, Volt, Hz
(iv) CT of ratio 1000/5 Amp- 01 Set of 3
(v) LED Phase Indication lamp (R, Y, B)-01 Set of 3
(vi) Bus Coupler ACB 4 Pole 2000 Amps ,50KA -01 No
Outgoing :- (i) ACB 1250 Amp 4 Pole - 01 Nos (ii) MCCB 4 pole 400 Amp, 50KA - 04 No
(iii) MCCB 4 Pole 320 Amp, 16 kA - 06 No (iv) MCCB 4 Pole 250 Amp, 16 kA - 04 No | 1 | Each | 16,42,852 ₹16,42,852 Lowest | 20,00,000 ₹20,00,000 | 22,61,000 ₹22,61,000 | 16,89,000 ₹16,89,000 | 23,00,000 ₹23,00,000 | 25,00,000 ₹25,00,000 | 23,99,999 ₹23,99,999 | 24,99,999 ₹24,99,999 |
| 2.00 | Supply & fixing of LT panel board suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of controlling ACB/MCCB capacity with colour insulating tape / sleeves mounted on suitable size "F" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and acessories inside complete all as specified and directed by Engr-in-Charge-
Incoming :- (i) MCCB 4 pole 400 Amp, 36KA, Ics=Icu= 100%, thermal magnetic release adjustaple type, Icu including spreader link - 01 No.
(ii) 4 Pole Aluminium Bus Bar 600 Amp
(iii) Digital type 3 Ph multifunctioning meter to measure Amp, Volt, Hz
(iv) CT of ratio 1000/5 Amp- 01 Set of 3
(v) LED Phase Indication lamp (R, Y, B)-01 Set of 3
Outgoing :-(i) MCCB 4 pole 200 Amp, 25KA, Ics=Icu= 100%, thermal magnetic release adjustaple type, Icu including spreader link - 01 No.
(ii) MCCB 100 Amp, 16KA, including spreader link - 03 Nos
(iii) MCCB 63 Amp 4 Pole, - 04 Nos (iv) MCB 20 Amp TPN -02 Nos | 1 | Each | 2,02,886 ₹2,02,886 | 1,75,000 ₹1,75,000 Lowest | 1,92,000 ₹1,92,000 | 2,95,000 ₹2,95,000 | 1,99,521 ₹1,99,521 | 2,50,000 ₹2,50,000 | 2,77,777 ₹2,77,777 | 4,99,999 ₹4,99,999 |
| 3.00 | Supply & fixing of LT panel board suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of controlling MCCB capacity with colour insulating tape / sleeves mounted on suitable size "F" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and acessories inside complete all as specified and directed by Engr-in-Charge :- (Bus Bar panel)
Incoming :- (i) 4 Pole Aluminium Bus Bar 300 Amp including 200 Amps MCCB
(ii) LED Phase Indication lamp (R, Y, B) - 01 Set of 3 | 2 | Each | 40,000 ₹80,000 | 50,000 ₹1,00,000 | 48,000 ₹96,000 | 55,000 ₹1,10,000 | 44,315 ₹88,630 | 35,000 ₹70,000 | 1,80,000 ₹3,60,000 | 24,999 ₹49,998 Lowest |
| 4.00 | Material and labour for earthing of galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5mtr below normal ground level connected to and including earth lead GI strip 32 x 6 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 32 x 6 mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified and directed by Engr-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe up to 7.5 meter beyond the earth plates electrode. | 8 | Each Set | 3,000 ₹24,000 | 2,500 ₹20,000 Lowest | 4,500 ₹36,000 | 4,000 ₹32,000 | 3,500 ₹28,000 | 10,000 ₹80,000 | 3,500 ₹28,000 | 4,999 ₹39,992 |
| 5.00Supply & laying or fixing or passing through pipe or in cable ducts, 1100 volts grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor complete all as specified and directed by Engr-in-Charge of the following size :- Note : Rate for cable lugs and glands deems to be included in qouted rate | |||||||||||
| 5.10 | 3.5 Core 240 Sqmm | 450 | RM | 1,400 ₹6,30,000 | 1,125 ₹5,06,250 | 1,370 ₹6,16,500 | 1,290 ₹5,80,500 | 1,228 ₹5,52,600 | 1,300 ₹5,85,000 | 1,060 ₹4,77,000 Lowest | 1,199 ₹5,39,550 |
| 5.20 | 3.5 Core 240 Sqmm | 200 | RM | 1,400 ₹2,80,000 | 1,125 ₹2,25,000 | 1,370 ₹2,74,000 | 1,290 ₹2,58,000 | 1,228 ₹2,45,600 | 950 ₹1,90,000 | 900 ₹1,80,000 | 799 ₹1,59,800 Lowest |
| 6.00 | Material and labour for excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft and loose soil complete all as specified and directed by Engineer-in-Charge | 137 | Cum | 85 ₹11,645 Lowest | 100 ₹13,700 | 100 ₹13,700 | 180 ₹24,660 | 100 ₹13,700 | 300 ₹41,100 | 99 ₹13,563 | 99 ₹13,563 |
| 7.00 | Material and labour for returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed by Engineer-in-Charge | 79 | Cum | 20 ₹1,580 | 20 ₹1,580 | 21 ₹1,659 | 40 ₹3,160 | 19 ₹1,501 Lowest | 100 ₹7,900 | 30 ₹2,370 | 19 ₹1,501 Lowest |
| 8.00 | Material and labour for removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge | 59 | Cum | 25 ₹1,475 | 20 ₹1,180 | 21 ₹1,239 | 40 ₹2,360 | 19 ₹1,121 Lowest | 100 ₹5,900 | 30 ₹1,770 | 19 ₹1,121 Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
5 Aug 2026, 6:00 pmClosed
GE Utility Electric Supply
GE Utility Electric Supply
SPL REPAIRS OF LT HT ELECTRIC PANEL AT SUB STATIONS IN 505 ABW UNDER GE U E S DELHI CANTT
2026_MES_778701_1
GE ELECT/TOKEN-17/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Utility Electric Supply
AS Per Tender Documents
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹88,000
1 Oct 2026
15 Jul 2026
7 Aug 2026
15 Jul 2026
5 Aug 2026
29 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & fixing of LT panel board suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of controlling ACB/MCCB capacity with colour insulating tape / sleeves mounted on suitable size "F" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and accessories inside complete all as specified and directed by Engr-in-Charge :-
Incoming :- (i) ACB 4 pole 2000 Amp, 50KA,Micro processor released manual drawout Adjustable type - 02 No. (ii) 4 Pole Aluminium Bus Bar 3000 Amp
(iii) Digital type 3 Ph multifunctioning meter to measure Amp, Volt, Hz
(iv) CT of ratio 1000/5 Amp- 01 Set of 3
(v) LED Phase Indication lamp (R, Y, B)-01 Set of 3
(vi) Bus Coupler ACB 4 Pole 2000 Amps ,50KA -01 No
Outgoing :- (i) ACB 1250 Amp 4 Pole - 01 Nos (ii) MCCB 4 pole 400 Amp, 50KA - 04 No
(iii) MCCB 4 Pole 320 Amp, 16 kA - 06 No (iv) MCCB 4 Pole 250 Amp, 16 kA - 04 No | 1 | Each | - | - |
| - | Supply & fixing of LT panel board suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of controlling ACB/MCCB capacity with colour insulating tape / sleeves mounted on suitable size "F" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and acessories inside complete all as specified and directed by Engr-in-Charge-
Incoming :- (i) MCCB 4 pole 400 Amp, 36KA, Ics=Icu= 100%, thermal magnetic release adjustaple type, Icu including spreader link - 01 No.
(ii) 4 Pole Aluminium Bus Bar 600 Amp
(iii) Digital type 3 Ph multifunctioning meter to measure Amp, Volt, Hz
(iv) CT of ratio 1000/5 Amp- 01 Set of 3
(v) LED Phase Indication lamp (R, Y, B)-01 Set of 3
Outgoing :-(i) MCCB 4 pole 200 Amp, 25KA, Ics=Icu= 100%, thermal magnetic release adjustaple type, Icu including spreader link - 01 No.
(ii) MCCB 100 Amp, 16KA, including spreader link - 03 Nos
(iii) MCCB 63 Amp 4 Pole, - 04 Nos (iv) MCB 20 Amp TPN -02 Nos | 1 | Each | - | - |
| - | Supply & fixing of LT panel board suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of controlling MCCB capacity with colour insulating tape / sleeves mounted on suitable size "F" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and acessories inside complete all as specified and directed by Engr-in-Charge :- (Bus Bar panel)
Incoming :- (i) 4 Pole Aluminium Bus Bar 300 Amp including 200 Amps MCCB
(ii) LED Phase Indication lamp (R, Y, B) - 01 Set of 3 | 2 | Each | - | - |
| - | Material and labour for earthing of galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5mtr below normal ground level connected to and including earth lead GI strip 32 x 6 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 32 x 6 mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified and directed by Engr-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc.
(b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe up to 7.5 meter beyond the earth plates electrode. | 8 | Each Set | - | - |
| 5 | Supply & laying or fixing or passing through pipe or in cable ducts, 1100 volts grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor complete all as specified and directed by Engr-in-Charge of the following size :-
Note : Rate for cable lugs and glands deems to be included in qouted rate | - | - | - | - |
| - | 3.5 Core 240 Sqmm | 450 | RM | - | - |
| - | 3.5 Core 240 Sqmm | 200 | RM | - | - |
| 6 | Material and labour for excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft and loose soil complete all as specified and directed by Engineer-in-Charge | 137 | Cum | - | - |
| - | Material and labour for returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed by Engineer-in-Charge | 79 | Cum | - | - |
| - | Material and labour for removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge | 59 | Cum | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
TD17.pdf
Tender Documents • 1.26 MB
BOQ_872203.xls
BOQ • 0.25 MB
AmendNO1t17.pdf
PDF • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .