| 1 | L1₹41.7 CrAdmitted-Finance | ₹41.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹42.4 CrAdmitted-Finance | ₹42.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹43.2 CrAdmitted-Finance | ₹43.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Guigui Kamei L3 | M/S KIM and Sons Constructions and Equipments L2 | Keystone Infra Pvt Ltd. L1 |
|---|---|---|---|---|---|---|
| 1.00CIVIL & DEVELOPMENT WORKS | ||||||
| 2.00SH (I) :- Main Building (Block - A )(G + 5) | ||||||
| 3.00Felling tree of girth measured at a height of 1 m above ground level including cutting of trunks and branches removing of root and stacking of serviceable materials and disposal of unserviceable materials. | ||||||
| 4.00 | (a) Beyond 30 cm and upto 60 cm in girth | 20 | each | 236 ₹4,720 | 232 ₹4,640 | 220 ₹4,400 |
| 5.00 | (b)Beyond 60 cm and upto 120 cm in girth | 5 | each | 842 ₹4,210 | 827 ₹4,135 | 780 ₹3,900 |
| 6.00 | Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m | 778.04 | m3 | 170 ₹1.3 L | 167 ₹1.3 L | 164 ₹1.3 L |
| 7.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre. | 259.35 | m3 | 136 ₹35,271.60 | 133 ₹34,493.55 | 130 ₹33,715.50 |
| 8.00 | Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete with a lead of 50m | 792.32 | m3 | 1,041 ₹8.2 L | 1,022 ₹8.1 L | 1,007 ₹8.0 L |
| 9.00 | Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size). | 209.15 | m3 | 8,952 ₹18.7 L | 8,787 ₹18.4 L | 8,650 ₹18.1 L |
| 10.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.) | 514.02 | m3 | 15,340 ₹78.9 L | 15,057 ₹77.4 L | 14,825 ₹76.2 L |
Tender Value
₹33.5 Cr
EMD Value
₹43.5 L
Closing Date
3 May 2021, 1:00 pmClosed
Executive Engineer-I/E
MPHC Complex, Imphal
Construction of New Police Head Quarter at Imphal, Manipur(Phase-I)
2021_MPHCL_1357_1
01/EE-I/E/MPHC/2021-22
Open Tender
Composite Works
365 days
As per tender document
Please refer tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd
₹43.5 L
27 Jul 2023
14 Apr 2021
3 May 2021
15 Apr 2021
3 May 2021
26 Apr 2021
16 Apr 2021 - 24 Apr 2021
Amount
CIVIL & DEVELOPMENT WORKS
SH (I) :- Main Building (Block - A )(G + 5)
Felling tree of girth measured at a height of 1 m above ground level including cutting of trunks and branches removing of root and stacking of serviceable materials and disposal of unserviceable materials.
(a) Beyond 30 cm and upto 60 cm in girth
(b)Beyond 60 cm and upto 120 cm in girth
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete with a lead of 50m
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement (a) 1: 1 : 2 (1 cement :1 Kanhaighat coarse sand: 2 graded stone aggregate 20 mm nominal size.) (i) Upto floor five level
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with two under reamer and of length 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d ) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(e) Staircases (e/c landing) slopping or stepped soffits including risers & stringers etc.
(f) Edges of slab and breaks in floors and walls (i) Under 20cm wide
(g) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttresses, plinth and the string courses and the like
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
2nd class (local first class) brick work in superstructure in cement mortar 1:3 (1 Cem: 3 Kanhaighat C/Sand) (a) above plinth level upto 1st floor level
(a) Above 1st floor level upto 2nd floor level.
(b) Above 2nd floor level upto 3rd floor level.
(c ) Above 3rd floor level upto 4th floor level.
(d) Above 4th floor level upto 5th floor level.
(e) Above 5th floor level upto 6th floor level.
Half brick masonry 2nd class (local first class) in cement mortar 1:3 (1 cement : 3 Kanaighat coarse sand) in superstructure (i) above plinth level upto 1st floor level.
(ii) Above 1st floor level upto 2nd floor level
(iii) Above 2nd floor level upto 3rd floor level
(iv) Above 3rd floor level upto 4th floor level
(v) Above 4th floor level upto 5th floor level
(vi) Above 5th floor level upto 6th floor level
Providing wood work in frames of doors, windows, c/windows & other frame and fixed in position.(a)Local best quality Teak wood.
Providing and fixing 50 mm thick panelled and glazed or panelled and glazed shutters for doors, windows, c/windows ect. Including bright finished brass hinges with necessary screws-(a) Local best quality Teak wood.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete. (a) 300 x 16 mm
P/F Brass Tower bolts with screws & nuts complete,(a) 250x10 mm
P/F Brass Handles with screws & nuts complete,(a) 125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.(a) Twin rubber stopper
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing in position collapsible steel shutters with vertical channels 20 mm X 10 mm X 2 mm & braced with flat iron diagonals 20 mm X 5 mm sizes with top & bottom rails of T iron 40 mm X 40 mm X 6 mm with 38 mm dia steel pullets complete with bolts & nuts, looking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
White ceramic glazed tiles 7.3 mm in flooring, treads or steps & landing laid on a bed of 12 mm thick cement mortar 1:3 (1 cement:3 coarse sand) finished with flush pointing in white cement.
Marble stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) white marble slab 20 mm thick (i) 60 x 90 cm
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat Coarse sand)finished with a floating coat of neat cement.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Applying ready mixed priming coat pink primer of approved quality on wood work.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for wood work of approved quality in all shades on new wood work to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to (i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-tapered and backed by acoustical tissue with NRC value not less than 0.60.charge and as per manufacturer's specification, with all 4 side
Providing and fixing aluminium works for doors windows, Ventilators and partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately):For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item): (i) With float glass panes of 4.0 mm thickness
Providing and fixing aluminium works for partions both extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285,bison board fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.:For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade (6mm thick Aluminium grill).
Conducting Pile load test as per IS 2911 Pt-IV for calculation of safe load capacity of pile i/c mobilisation and demobilisation of all requisite machineries and equipments along with submission of reports etc. complete as per direction of the Engineer - in-charge
SH (II) :- Main Building (Block - B )(Bored Pile Foundation only)
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1:2 (1 cem:1 c/sand:2 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with two under reamer and of length 21.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
SH (III) : STRUCTURAL GLAZING WORKS
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry /structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2)
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
SH (IV) : Water Supply and Sanitary Installation
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m in Hard dense soil.(a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) 1:3:6 (1 cem :3 Coarse sand:6 graded stone aggrt.40mm n/size).
(b) 1:2:4 (1 cem :2 Coarse sand:4 graded stone aggrt.20mm n/size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 coarse sand:2 Kanhaighat graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars.
(a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(a ) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(b) Edges of slab and breaks in floors and walls (i) Under 20cm wide
2nd class (local first class) brick work in foundation upto plinth in cement mortar 1:4(1 Cem: 4 Kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:3 (1 cement : 3 Kanaighat coarse sand) in superstructure
15 mm cement plaster 1:3(1 cement:3 Kanhaighat Coarse sand)finished with a floating coat of neat cement.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required (a):White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush complete including painting of fitting and brackkets cutting and making good the wall and floors wherever required. one urinal basin with 5 litre white PVC automatic flushing cistern
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets, 15 mm CP brass pillar taps and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (a) Kitchen sink with drain board (510x1040 mm bowl depth 250 mm)
Providing and fixing C.P. brass toilet paper holder
Providing and fixing C.P. brass shower rose with 12.5 mm or 19 mm inlet (a) 150 mm diameter
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type SONA).
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
(b) 75 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 25mm diameter
Providing and fixing grating of approved quality for Nahni trap Stainless steel, 125mm nominal diameter with 25mm waste hole
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 2000 litres net capacity storage tanks
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
SH (V) : GROUND SUMP OF 70 KL
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil anddisposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a). C.C. 1:4:8 (1 cement :4 Kanhaighat coarse sand 18 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d)Flat surface such as suspended flloor,roofs, landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floor not exceeding 1m in depth
(f) Vertical surface such as walls (any thickness), partition and the like including attached pilasters,buttreese, plinth and the string courses and the like
15mm cement plaster 1:3 (1 cement : 3Kanhaighat coarse sand)with a neat caot of cement
P/F CI cover with frame for(manhole and chamber)(a)600x450 (Heavy duty)
SH (VI) : STORM WATER DRAIN
2nd class brick masonary 30 x 60cm open surface drain in c.m. 1: 4(1cem : 4 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 15mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
SH (VII) : DECORATIVE FENCING
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m (a) Hard dense soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement (a) 1: 1: 2 (1 cement :1 Kanhaighat coarse sand: 2 graded stone aggregate 20 mm nominal size.) (i) Upto floor five level
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing & fixing Steel Grill by using 40x40 mm Square section as main bars horizontally and vertically, Square section 40x40 mm as rail bars ,25x25mm Square section as style bars, connecting bars Square section 16x16 mm to arrow of decorative type (Cast Iron) readily available at Market i/c painting,Priming etc. complete as per direction of Engineer-in-Charge (conforming to Architectural drawing No. MPHC/A-C6).
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
SH (VIII) : COMPOUND FENCING
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m (a) Hard dense soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement (a) 1: 1 :2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.) (i) Upto floor five level
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.steel bars. (a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:3 (1 cement : 3 Kanaighat coarse sand) in superstructure (i) above plinth level upto 1st floor level.
Providing & fixing Steel Grill by using 25x25 mm Square section as main bars horizontally and vertically with arrow of decorative type (Cast Iron) readily available at Market i/c painting,Priming etc. complete as per direction of Engineer-in-Charge (conforming to Architectural drawing No. MPHC/A-C6).
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
SH (IXI) : SENTRY TOWER - 8 NOS.
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
(b) Lift above 1.5 m upto 3.0 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete with a lead of 50m
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat Coarse sand :10 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Kanhaighat Coarse sand:4 graded stone aggrt.20mm n/size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat Coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 Kanhaighat Coarse sand:2graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.2(1 cement :1. Kanhaighat Coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting ,bending,placing in position and binding all complete.
(b) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b)Columns, pillars, posts and struts (square, rectangular or polygon in plan
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d)Flat surface such as suspended flloor,roofs, landing & the like (i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floor not exceeding 1m in depth
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat Coarse sand)
2nd class (local first class) brick work in superstructure (1) above plinth level upto 1st floor level in cement mortar 1:4(1 Cem:4C/Sand)
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position. (c) Uchan/Tairen /Tolhao/Khangra.
P/F20 mm thick plank as eave board with (b). Tolhao/Uchan wood
Steel welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint (a) In grating, framed guard bars, ladders, raillings, brackets and similar works.
Providing & fixing expanded metal 20 x 60 mm strands 3.25m wide & 1.6 mm thick for windows etc. i/c 60 x 20 mm beading of 1st class Uningthou.
P/F 1 mm thick M.S. sheet garrage doors with frame of 40 X 40 X 6 mm, angle iron 3.15 mm M.S. gusset plate at the junction of corners with handles, stoppers of locking arrangement etc. i/c applying a priming coat of red lead paint. (i) Using M.S. angles 40 x 40 x 6mm for diagonal braces.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Trepezoidal pre- painted profile sheet roofing of approved brand dyna roof or equivalent with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPGL) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Trepezoidal pre- painted profile sheet roofing for ridges /gutter or valley 610 mm wide approved brand dyna roof or equivalent fixed with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPG) (i) profile sheet 0.50 mm 4.2 kgs per SQM
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat Coarse sand)finished with a floating coat of neat cement.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Coal tarring two coats on new work using 10 sqm. not less than 1.6 litres of coal tar of approved quality for 1st coat 1.2 litres for second coat.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
SH (X) ; REGISTRATION & RECIEPT ROOM
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil anddisposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
(b) Above 1.5m upto 3.00m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 Km
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 Kanhaighat Coarse sand:2graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
(b) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers,girders, bressummers and lintels not exceeding 1m in depth.
(d) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
2nd class (local first class) brick work in superstructure (i) above plinth level upto 1st floor level in cement mortar 1:4(1 Cem:4C/Sand)
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing wood work in frame of false ceiling, partition etc sawn and put up in position (b) Uchan/Tairen Wood
Providing and fixing aluminium works for doors windows, Ventilators and partions woth extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately):For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item): (i) With float glass panes of 4.0 mm thickness
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand), including grouting the joints with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 Kanhaighat coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Trepezoidal pre- painted profile sheet roofing of approved brand dyna roof or equivalent with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPGL) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Trepezoidal pre- painted profile sheet roofing for ridges /gutter or valley 610 mm wide approved brand dyna roof or equivalent fixed with selt driling screws of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPG) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Providing and fixing 4mm thick Rhino Brand A.C.Duro Board (Plain sheet) of 610x610 mm ceiling Roofing and Ceiling Item) with wooden beading 62x12mm Leihao wood spaced 61 cm centre to centre maximum on both sides etc complete ( frame work to be paid separately).
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrome primer conforming to IS : 2074-1979, welded and bolted incluiding special shape washer etc. complete. (a) Electric resistant welded tube (Conforming to IS : 1611 - 1979).
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying wall putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Coal tarring two coats on new work using 10 sqm. not less than 1.6 litres of coal tar of approved quality for 1st coat 1.2 litres for second coat.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat c/sand) with a floating coat of neat cement inside & outside as per standard design.
P/F 3mm thick M.S.Sheet eave board with ISA 25x25x4mm and flat 25x4mm with primer and painting complete as per direction of Engineer-in- Charge.
SH (XI) :MAIN GATE - 2 Nos.
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil anddisposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
(b) Above 1.5m upto 3.00m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure (1) above plinth level upto 1st floor level.
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying wall putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Providing & fixing Steel Gate by using 50x50 mm Square section as main bars horizontally and vertically, Square section 40x40 mm as rail bars ,35x35mm Square section as style bars, connecting bars Square section 16x16 mm to arrow of decorative type (Cast Iron) readily available at Market i/c painting,Priming etc. complete as per direction of Engineer-in-Charge (conforming to Architectural drawing No. MPHC/A-C6).
SH (XII) : APPROACH ROAD
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavted soil and disposal od surplus excavated soil as directed within a lead of 50 m (a) Hard dense soil.
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Coarse sand:4 graded stone aggrt.20mm n/size).
Providing and laying 80 mm thick factory made cement concrete interlocking paver block (Rubber Moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the Engineer-in-charge.
Providing laying & compacting granular base/sub-base according to lines, grades& cross-sections by using naturally occurring sand gravel/conforming to IRC Grade 2 of M.O.S.T. specification free from organic or other deleterious constituents compact by rolling with power roller of 8 to10 tonnes capacity in layers not exceeding 150 mm (spread thickness)including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge. ( with carriage charge of all materials)
Providing and laying one layer W.B.M. 7.5 cm consolidated thickness using 1 cum of stone aggregate conforming to IRC Grades per 10 sqm of road surface & 0.23cum of binder materials of approved quantity per 10 sqm of road surface including consolidating of the same, rolling of the surface to camber, superelevation & grade by using template straight edges & spirit level in layers not exceeding 100 mm to 130 mm thick (spread thickness), dry & wet rolling with 8 to10 tonne roller including earth edging 30 cm width on both sides & applying binding materials as specified (with carriage charge of all materials). (i) I.R.C. Grade -II
(ii) I.R.C. Grade - III
Preparing surface by brushing with wire brushes for remaining caked mud etc. sweeping with brooms and finally fanning the cleared surface with gunny bags to removed all loose dirt etc.(a) Water bound macadam surface new
Providing & applying evenly a priming/tack coat with bitumen (80/100).(a) 10 kg/10sqm
Providing and laying bituminous macadam of 50 mm as per clause 504.1 of "MOST" specification for base course with binder content @ 4% by weight of total mix including preparation of bases including filling of pot holes, cleaning the surface with wire brushes etc. and providing suitable edge supports heating of binder and aggregate handling of materials, screening, mixing, in hot mix plant conforming and transporting laying and finishing with paver finisher to the required level, grade and camber, rolling by power roller etc. complete including running expenses of all plants.
2 cm consolidated thick single coat pre-mix carpet surfacing with 0.27 cum stone chipping 12.5 mm size 0.18 cum and 10 mm size 0.09 cum mix with 14.6 kg of binder per 10.00 sqm of road surface and rolling complete including a seal coat IRC type "A" with 0.09 cum of stone chipping 6.3 mm nominal size and 9.8 kg of bitumen 80/100 per 10.00 sqm of road surface.
SH (XIII) : KITCHEN CUM DINING HALL
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 50m
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:5:10 (1 cem :5 Coarse sand: 10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 Kanhaighat Coarse sand:2graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
(b) Thermo-Mechanically Treated bars.
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers,girders, bressummers and lintels not exceeding 1m in depth.
(d) Flat surface such as suspended floor,roof,landing & the like (i) floor etc upto 200mm in thickness.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
2nd class (local first class) brick work in foundation and plinth level in cement mortar 1:4(1 Cem:4 Kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) in superstructure above plinth. (a) Upto 1st floor level.
Polygonal rubble masonary/R.R. masonary (uncoursed/ brought to course)/Sq. rubble masonary (uncoursed/ brought to courses) with hard stone of approved quality in foundation and plinth in cement mortar 1 : 6 (1 cement : 6 Kanhaighat coarse sand) including levelling with cement concrete 1 : 6 : 12 (1 cement : 6 Kanhaighat coarse sand : 12 gr. st. aggregate 20 mm nominal size).
Providing wood work in frames of doors, windows, c/windows & other frame and fixed in position.(a) local best qlty Leihao wood.
P/F 38 mm thick panelled, glazed or panelled & glazed shutters for doors, windows and clerestory windows i/c bright finished brass hinges (ordinary type) with necessary screws.(a) Local best quality Leihao/Tolhao.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarsesand : 6 stone aggrt. 20mm nominal guage).
Providing & fixing local best quality plain lining tongued & grooved on & i/c wooden plug complete with necessary screws & priming coat on unexposed surface.a) 19mm thick (ii) Local best quality Leihao
Providing wood work in frame of false ceiling, partition etc sawn and put up in position (b) Uchan/Tairen Wood
Providing & fixing M.S. round or square bars at required spacings in windows frame of window & clerestory window.
Providing & fixing expanded metal 20 x 60 mm strands 3.25m wide & 1.6 mm thick for windows etc. i/c 60 x 20 mm beading of 1st class Uningthou.
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete. (a) 300 x 16 mm
P/F Brass Tower bolts with screws & nuts complete,(a) 250x10 mm
P/F Brass Handles with screws & nuts complete,(a) 125mm
P/F M.S. round holdig down or anchor bolts with nuts & washer plates complete.
Trepezoidal pre- painted profile sheet roofing of approved brand dyna roof or equivalent with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPGL) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Trepezoidal pre- painted profile sheet roofing for ridges /gutter or valley 610 mm wide approved brand dyna roof or equivalent fixed with selt driling screws of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPG) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Providing and fixing 4mm thick Rhino Brand A.C.Duro Board (Plain sheet) of 610x610 mm ceiling Roofing and Ceiling Item) with wooden beading 62x12mm Leihao wood spaced 61 cm centre to centre maximum on both sides etc complete ( frame work to be paid separately).
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrome primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete. (a) Electric resistant welded tube 9 Conforming to IS : 1611 - 1979).
Providing and fixing aluminium works for doors windows, Ventilators and partions woth extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fiixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up gaps at junctions, at top,bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium snap beading for glazing /panelling, C.P. brass/ Stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately):For shutters of doors, windows & ventilators including, providing and fixing hinges/ pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).(a) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item): (i) With float glass panes of 4.0 mm thickness
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,complete. (a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat Coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat Coarse sand)finished with a floating coat of neat cement.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Applying ready mixed priming coat pink primer of appd Quality on wood work
Applying ready mixed priming coat (genuine red lead of appd. Quality) on steel work.
Coal tarring two coats on new work using 10 sqm. not less than 1.6 litres of coal tar of approved quality for 1st coat 1.2 litres for second coat.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of appd. quality in all shades on new work to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanhaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat c/sand) with a floating coat of neat cement inside & outside as per standard design.
P/F 3mm thick M.S.Sheet eave board with ISA 25x25x4mm and flat 25x4mm with primer and painting complete as per direction of Engineer-in- Charge.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.(a) Twin rubber stopper
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (a) 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.(a) 15 mm nominal outer dia Pipes
Providing and fixing brass bib cock of approved quality.(a) 15 mm diameter (Ordinary)
Providing and fixing brass stop cock of approved quality. (a) 15 mm diameter
Providing and fixing brass full way G.M valve with CI wheel of approved quality.(a) 32mm diameter
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets, 15 mm CP brass pillar taps and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (a) Kitchen sink with drain board (i) 510x1040 mm bowl depth 250 mm
Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a) 1000 litres net capacity storage tanks
SH (XIV) : 50 SM BARRACK (G+1)
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift upto 1.5 m
(b) Lift above 1.5m upto 3.00m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 50m
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement (a) 1: 1 :2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.) (i) Upto floor five level
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.
(b) Thermo-Mechanically Treated bars.
2nd class (local first class) brick work in foundation and plinth level in cement mortar 1:4(1 Cem:4 Kanhaighat C/Sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure above plinth. (a) Upto 1st floor level.
Polygonal rubble masonary/R.R. masonary (uncoursed /brought to course)/Sq. rubble masonary (uncoursed/brought to courses) with hard stone of approved quality in foundation and plinth in cement mortar 1 : 6 (1 cement : 6 course sand) including levelling with cement concrete 1 : 6 : 12 (1 cement : 6 course sand : 12 gr. st. aggregate 20 mm nominal size).
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides & soffits of beams, beam haunchings, cantilevers, girders, bressummers and lintels not exceeding 1m in depth.
(d) Flat surface such as suspended floor,roof,landing & the like (i) floor etc upto 200mm in thickness.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
(e) Staircases (e/c landing) slopping or stepped soffits including risers & stringers etc.
Providing wood work in frames of doors, windows, c/windows & other frame and fixed in position.(a) local best qlty Leihao wood.
Providing and fixing 38mm thick panelled and glazed or panelled and glazed shutters for doors, windows, c/windows ect. Including bright finished brass hinges with necessary screws-(a) local best qlty Leihao wood.
P/F 25 mm thick panelled and glazed or panelled or glazed shutters for cupboard i/c black-enamelled or bright finished M.S. butt hinges with necessary screws. (a) Leihao/Tolhao wood
38 mm thick wooden shelves supported on 40 x 40 x 6 mm T or L iron brackets fixed at suitable distance but not exceeding 75cm apart in 7.5 x 7.5 x 15 cm blocks of cement concrete 1:3:6 (1 cement:3 coarse sand :6 stone aggregate).(a) Local best quality Leihao wood
Providing & fixing fly proof galvanised M.S. wire gauge of IS gauge of designation 14 O.G. with wire of diameter 0.56 mm to window & clerestory window i/c 62 x 19 mm beading of (a) Local best quality Leihao
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarsesand : 6 stone aggrt. 20mm nominal guage)
P/F 3mm thick M.S.Sheet eave board with ISA 25x25x4mm and flat 25x4mm with primer and painting complete as per direction of Engineer-in- Charge.
Providing wood work in frame of false ceiling, partition etc sawn & put up in position.c) Leihao wood
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete. (a) 300 x 16 mm
P/F Brass Tower bolts with screws & nuts complete,(a) 250x10 mm
P/F Brass Handles with screws & nuts complete,(a) 125mm
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Trepezoidal pre- painted profile sheet roofing of approved brand dyna roof or equivalent with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPGL) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Trepezoidal pre- painted profile sheet roofing for ridges /gutter or valley 610 mm wide approved brand dyna roof or equivalent fixed with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPG) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Providing & fixing corrugated transluscent acrylic aluminium sheet roofing 22.24 or 26 B.G. fixed with galvanised iron J or L hooks 8 mm dia G.I. limpet & bitumen washer complete excluding cost of purlins, rafter & trusses & aluminium sheet etc. complete.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrome primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete. (a) Electric resistant welded tube 9 Conforming to IS : 1611 - 1979)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Coat tarring two coats on new work using 10 sqm. not less than 1.6 litres of coat tar of approved quality for 1st coat 1.2 litres for second coat.
Applying ready mixed priming coat pink primer of appd Quality on wood work
Applying ready mixed priming coat (genuine red lead of appd. Quality) on steel work.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of appd. quality in all shades on new work to give an even shade.
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat Coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required (a):White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing 610 X 450 mm bevelled edge Mirror of Indian make superior glass (of approved quality) quality complete with asbestos sheet ground, fixed to wooden cleat with C.P. brass screws and washers.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type SONA).
Providing and fixing soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing C.P. brass shower rose with 12.5 mm or 19 mm inlet.(a) 15 mm diameter.
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge (b)110mm dia
(b) 75 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)15 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (i) 25 mm nominal outer dia Pipes
Providing and fixing 50 mm Terminal guard.
Providing and fixing C.P. bib cock of superior quality.(a) 15 mm diameter.
Providing and fixing brass stop cock of superior quality.(a) 15 mm diameter.
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 25mm diameter
Providing and fixing C.I. cover with frame for (manhole and chamber). (a) 600 X 450 mm (Heavy duty) ( 38 kg).
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube including hoisting a height of 10 m above ground level. (a) 2000 litres net capacity storage tanks.
ELECTRICAL & FIRE FIGHTING WORKS
SH (A) : Providing IEI in Main Building (Block-A)(G + 5)
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
(a) Group A
(b) Group B
(c) Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
(a) 2X1.5mm2+1X1.5mm2 earth wire
(b) 2X2.5mm2+1X2.5mm2 earth wire
(c) 2X4mm2+1X4mm2 earth wire
(d) 2X10mm2+2X10mm2 earth wire
(e) 4X16mm2+2X16mm2 earth wire
(f) 4X25mm2+2X16mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 15/16 amps switch
(c) 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
Supply and drawing (following pair) 0.5mm2 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as reqd.
Supply and drawing Co-Axial TV cable RG-6 grade 0.7mm solid copper conductor PE insulated shielded with file tinned copper braid and protected in PVC sheath in existing surface/recessed steel/PVC conduit as reqd.
S/F I.O Outlet Box for RJ 45
Fixture Items
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F fancy wall bracket suitable for 1X15W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS12W LED 8575 complete with connection as rqd. (Havell's)
SITC Aesthetically designed 2X2 LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination PLUTOSURFACE2X2PLS42WLED857S.
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
S/F Puro Plus water heater (Geyser) AC 2KW vertical type with accessories GHWAPFTIVO15/GHWAPFTW025 (Havells) i/c connection etc. as reqd. (Ivory)
MS & DB Boards
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 400 amp. TPN on load changeover switch - 1 No.
2. 400 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 6 Nos.
P/F (following rating and breaking capacity) MCCB in existing cubicle panel board including driling holes in cubicle panel & making connection as reqd.
(a) 4 pole MCCB 100 amp 16 KA
P/F following RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd.
(a) 63 amp. Four pole RCCB 100mA/300mA.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (4+18 way) double door TPN prewired, sheet steel MCCB distribution board 240V on surface/recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, dinbar, detachable gland plate, interconnection, phosphatized powder painted i/c earthing etc. as reqd. (but without MCB/RCCB/Isolator).
P/F following RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd.
(a) 63 amp. Two pole RCCB 100mA/300mA.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
Earthing
P/F of lightning conductor finial made of 25mm dia. 900mm long copper tube having 5-prong at top with 85mm dia. 3mm thich copper plate including holes etc. complete as required.
Fixing of lightning conductor finial 25mm dia. 900mm long copper/GI tube having 5-prong at top with 85mm dia. 3mm thick base plate i/c holes etc. as reqd.
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for vertical)
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for horizontal)
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
50mm2 3.5 core PVC ins.(heavy duty) Al.cond.armoured cable of 1.1KV grade of size not exceeding 25mm2 but not exceeding 125mm2 direct in ground i/c excavation sand, cushioning protective covering & refilling etc.as reqd.
70mm2 3.5 core PVC ins.(heavy duty) Al.cond.armoured cable of 1.1KV grade of size not exceeding 25mm2 but not exceeding 125mm2 direct in ground i/c excavation sand, cushioning protective covering & refilling etc.as reqd.
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Air Conditioner
S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X4mm2+1X4mm2 earth wire
(b) 2X16mm2+1X16mm2 earth wire
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 400 amp. TPN on load changeover switch - 1 No.
2. 400 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 6 Nos.
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (4+18 way) double door TPN prewired, sheet steel MCCB distribution board 240V on surface/recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, dinbar, detachable gland plate, interconnection, phosphatized powder painted i/c earthing etc. as reqd. (but without MCB/RCCB/Isolator).
P/F following RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd.
(a) 63 amp. Two pole RCCB 100mA/300mA.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
50mm2 3.5 core PVC ins.(heavy duty) Al.cond.armoured cable of 1.1KV grade of size not exceeding 25mm2 but not exceeding 125mm2 direct in ground i/c excavation sand, cushioning protective covering & refilling etc.as reqd.
Elevator
SITC of Automatic gearless elevator/lift of 8(eight) passengers capable of load about 544 kgs @ 1mt/sec. with car size 1100mmx1300mm deep, car enclosure, entrance, machine room, power operated automatic door operation including necessary assembling at site make Omega Elevators.
SH ( B) : Fire Fighting & Fire Detector System
SECTION-A
INTERNAL HYDRANT
Providing and fixing black steel pipes for internal hydrant & sprinkler piping to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections required including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.
(a) 100mm dia NB
(b) 80mm dia NB
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Supplying, installation,testing and commissioning of stainless steel office plates and having 6mm nominal thickness, upto 200mm outer dia. And internal dia. Suitable to reduce pressure to between 3.2 to 3.5 kg/sq.mm complete as required.
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing standard short size stainless steel branch pipe with gunmetal nozzle 16mm dia outlet with standard instantaneous type 63mm dia coupling (ISI marked)
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.
Providing & fixing stainless steel fire brigade inlet with 63mm dia instantaneous type inlet and 150mm dia flanged outlet with built in check valve for fir brigade connection to underground tanks and fire risers (I.S 904-1965) tested for 20kg/cm2 pressure complete in all respects with companion flanges, nuts, bolts, gaskets, etc. (a) Two way
Providing and fixing gunmetal single acting air release valve with screwed inlet 25mm dia as per IS 12992 reted for 20kg/sq.cm.
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
(a) 25mm dia full bore type
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanfes as per table "E" complete in all respects.
(a) 100mm dia with lever
Providing and fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
(a) 100mm dia
SECTION-B
INTERNAL SPRINKLER
Supplying and fixing M.S. pipe to I.S. 1239 (Heavy Class) complete with all fittings like, unions, coupling, bends, elbows, fees, offsets, reducers, flanges, as per table "E" etc. to complete the work as per the requirement at site including painting with one coat of primer after surface preparation and two coats of thick synthetic enamel paint, cutting and making good the walla good complete. Note: The pipe will be hung from the ceiling using GI fully threaded rods and GI Hanger rings only.
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Providing & fixing 15mm dia chromium plated brass sprinkler head with quarztzoid bulb and set to operate at 68 Dec C complete in all respects.
Pendent type
Ceiling Rossette
Flexi Drop-UL Listed (upto 1000mm)
Supplying & fixing vane type waterflow switch suitable for installation on 50mm to 150mm dia line for a service pressure upto 20kg/sq.cm to be connected to Fire Alarm Syatem.
SECTION-C
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
(a) 100mm dia
SECTION-DIN
PUMPS AND ACCESSORIES
Supply, installation,testing and commissioning of electrically driven high pressure centrifugal fire hydrant/sprinkler pump, suitable for automatic operation consicting of the following:
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and ccoupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 1620 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Squirrel cage induction motor, TEFC type suitable for operation on 415volts, 3 phase 50Hz A.C supply for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (upto date) with flexible coupling and coupling guard, complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
f. The rate includes interconnecting cables, foundations & foundation bolts.
Supply, installation,testing and commissioning of deisel engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date.
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 1620 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory and shall be gotten approved by the Local Fire Authority).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Radiator cooled diesel engine of speed 1800 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation fo 8 hours continuous working. The tank shall be fitted with magnetic oil lever indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade) 2 nos. x 12 volts battery, flexible coupling, coupling guard & exhaust pipe connection complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
Supply, installation,testing and commissioning of jockey pump (pressurisation pump) comprising of the following:
a. Vertical mutistage centrifugal pump, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and coupling guard complete as required.Jockey pump shall be of stainless steel construction.
The pump head and base shall be CI GG20 construction and impellers, diffusers, shaff sleeve, seal bush & pump shaff shall be in $$ 304 material.The pump shall be provided with mechanical seal. The system shall be complete with necessary pressure guage with gun metal shut off cock on delivery side. (The pump should be tested and assembled for bench mark at factory)
b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as reqd.
c. Common base plate for (a) and (b) from M.S. Channel for required size.
d. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
For pump defined above & of duty as follows:
Hydrant & Sprinkler System
Flow: 180 LPM
Head: 70 mts
Providing, fixing, testing and commissioning of epoxy coated MS body precharged pressure/air vessel 300 ltr capacity having a pressure rating of 1.6 bar for pressurization of hydrant/sprinkler system complete in all respect with valves to operate as per operating sequences incliding 25mm dia drain valve, air release valve duly painted from inside and outside complete as required.
SITC of Pressure guage
Supply, installation,testing and commissioning of 100mm dia bourden type, stainless steel dial type glycerine fillede pressure guage including brass isolation valve and pipe having caliberation of 0-16 kg/cm2.
a. Providing & fixing welded pipe suction header upto 6 mtr. Long with two inlet. All outlets and ends with flanged connections, blank, flanges as required including painting with one coat of red oxide primer and two or more coats of synthetic enamel paint to give an even shade.
200mmx6mm thick-150mmx2 inlet; 80mmx1 inlet; 150mmx1 outlet
Providing and fixing black steel pipes to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections, all type of welded or screwed joint as per specifications and making connections required, including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more coats of synthetic enamel paint of first grade as per IS specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.(Make: Tata/Jindal/Nezone)
Providing and fixing black steel pipes to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections, all type of welded or screwed joint as per specifications and making connections required, including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more coats of synthetic enamel paint of first grade as per IS specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.(Make: Tata/Jindal/Nezone)
Providing and fixing black steel pipes to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections, all type of welded or screwed joint as per specifications and making connections required, including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more coats of synthetic enamel paint of first grade as per IS specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.(Make: Tata/Jindal/Nezone)
(a) 200mm dia NB
(b) 150mm dia NB
(c) 100mm dia NB
(d) 80mm dia NB
(e) 65mm dia NB
Providing & fixing cast iron Foot valves including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion as per table
(a) 200mm dia
(a) 80mm dia
Providing & fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion flanges as per table "E" complete
(a) 150mm dia
(b) 65mm dia
Providing & fixing MS structural work fabricated from standard sections, eg., MS rounds, angels, channels, including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by the engineer-in-charge including cutting and making good the walls and floors (for Pipe Support Structures & Cable Tray)
Providing & fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanges as per table "E" complete in all respects.
80mm dia with lever
65mm dia with lever
150mm dia with lever
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
SITC of Pressure Switches
ELECTRICAL INSTALLATION FOR FIRE PROTECTION SYSTEM
MCC for fire fightingequipments
a. 1 No. 400 amps 4 pole mechanical interlocked incoming MCCB complete with the following:
iii. Phase indicating lamp shall be protected by 2 amp SP MCB 1 set
b. Aluminium bus bar sleeves type rated at 500 amps for three phase & neutral phase bus bar shall have maximum current density of 1 amp/sq.cm and the neutral bus bar of not less than 50% capacity.
Outgoing:
b. 1 No. 32 amps TPN MCCB, 7.5 KW direct online starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall contain CT operated ammeter of 0-30 amps & indicating lamp with MCBs for 'ON'/'OFF' TRIP status of pump motor.
c. Providing and fixing 1 No. auto start panel activated with pressure switch for diesel engine complete with all accessories, batteries, battery charger of suitable rating, MCB timers, push buttons, microprocessor based alarm annunclator, wiring and cabling including connection to diesel engine complete as required ready for working.
d. Necessary cable alleys space for spare switchs, internal wiring and copper earthing of all equipment shall also be included. All switch gears/control gears shall be motor duty rating.
Note: All MCCB's to be suitable for motor duty shall be of 36KA breaking capacity.
Provision shall be made for providing potential free contacts to all pumps starters for connection for building automation system.
MCC as described above
SECTION-E
HAND APPLIANCES
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
Providing and fixing at approved location approved make 4 nos., for buckets of 24 guage galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black nd gold including stand fabricated out to sheet metal (16 guage) shade, platform and associated civil works, painting etc. as approved by the department.
F. FIRE ALARM
Supply, intallation, testing and commissioning of Conventional optical smoke detector with base complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of Conventional Hooter complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of PVC Body Manual Call Point (non-glass type) complete in all respect Morley, Apollo, System Sensor, Agni
Supply, intallation, testing and commissioning of Conventional Fire Alarm Panel System Sensor, Ravel, Agni
Microprocessor controller and LCD Display
Supplying, drawing, connecting, testing & commissioning of 2 corex1.5 sq.mm multi stranded copper conductor, pvc insulated PVC sheathed, aluminium myler tape shielded armoured cable suitable for Fire Alarm System. Havells, Polycab, Crystal, Gloster.
SH (C) : Providing IEI in the 50 S.M. Barrack
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
(a) Group A
(b) Group B
(c ) Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
(a) 2X1.5mm2+1X1.5mm2 earth wire
(b) 2X2.5mm2+1X2.5mm2 earth wire
(c ) 2X4mm2+1X4mm2 earth wire
(d) 2X10mm2+2X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 15/16 amps switch
(c ) 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
Supply and drawing Co-Axial TV cable RG-6 grade 0.7mm solid copper conductor PE insulated shielded with file tinned copper braid and protected in PVC sheath in existing surface/recessed steel/PVC conduit as reqd.
S/F I.O Outlet Box for RJ 45
Fixture Items
S/F fancy wall bracket suitable for 1X15W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS12W LED 8575 complete with connection as rqd. (Havell's)
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 400 amp. TPN on load changeover switch - 1 No.
2. 400 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 6 Nos.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
P/F following RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd.
(a) 63 amp. Two pole RCCB 100mA/300mA.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
Earthing
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply, Installation, Testing & Commissioning of solar LED street lamp All-In-One with in built SCC system wattage of 25/30 W of make Crompton Greaves Ltd.code no.CSADEMP25/30CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel and G.I.Tubular/Octagonal pole of 6mt.high including connection and muffling in R.c.c. 1:3:6 ( 1 cemt:3 c/sand: 6 stone aggrt of 40 mm n/size) including centering, shutturing, earth work etc.as reqd.
Fire Fighting and Fire Extinguisher
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
(a) 100mm dia
(b) 80mm dia NB
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
SH (D) : Providing IEI in the kitchen cum dining hall
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
(a) Group A
(b) Group B
(c ) Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
(a) 2X1.5mm2+1X1.5mm2 earth wire
(b) 2X2.5mm2+1X2.5mm2 earth wire
(c ) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 15/16 amps switch
(c ) 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
Fixture Items
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS12W LED 8575 complete with connection as rqd. (Havell's)
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
P/F 30/32A SPN switch fuse 240/250V i/c drilling hole on board, connection, earthing the body etc. as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
Earthing
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply, Installation, Testing & Commissioning of solar LED street lamp All-In-One with in built SCC system wattage of 25/30 W of make Crompton Greaves Ltd.code no.CSADEMP25/30CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel and G.I.Tubular/Octagonal pole of 6mt.high including connection and muffling in R.c.c. 1:3:6 ( 1 cemt:3 c/sand: 6 stone aggrt of 40 mm n/size) including centering, shutturing, earth work etc.as reqd.
SH (E) : Providing IEI in the Sentry Tower
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
(a) Group A
(b) Group B
(c ) Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 3 pin 5/6 amps socket outlet
Fixture Items
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's JETACOMPECT OF 50W LED 757LTG complete with connection as rqd. (Havell's)
P/F 30/32A SPN switch fuse 240/250V i/c drilling hole on board, connection, earthing the body etc. as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SH (F) : Providing IEI in the Registration/Receipt Room
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
(a) Group A
(b) Group B
(c )Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 15/16 amps switch
(c ) 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
Fixture Items
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver EN DURANEOHESURFACEDLS12W LED 8575 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
P/F 30/32A SPN switch fuse 240/250V i/c drilling hole on board, connection, earthing the body etc. as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
Earthing
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply, Installation, Testing & Commissioning of solar LED street lamp All-In-One with in built SCC system wattage of 25/30 W of make Crompton Greaves Ltd.code no.CSADEMP25/30CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel and G.I.Tubular/Octagonal pole of 6mt.high including connection and muffling in R.c.c. 1:3:6 ( 1 cemt:3 c/sand: 6 stone aggrt of 40 mm n/size) including centering, shutturing, earth work etc.as reqd.
M/S KIM and Sons Constructions and Equipments
Guigui Kamei
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Documents.pdf
Tender Documents • 1.18 MB
Drawing.pdf
Additional Documents • 7.84 MB
Schedule_of_materials.pdf
Additional Documents • 0.28 MB
BOQ_1519.xls
BOQ • 0.70 MB
Download all tender documents and submit your bid