Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.6 LAccepted-AOC 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹30.8 L+₹43,266 (1.42%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹31.1 L+₹71,348 (2.35%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹31.2 L+₹82,704 (2.72%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹31.7 L+₹1.3 L (4.36%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹39 L
EMD Value
₹80,000
Closing Date
29 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
REPAIR /MAINT OF STREET/SECURITY LIGHTS, JUNCTION BOXES AND CONNECTED UG CABLES ACCESSORIES AND 16 SWIVEL LIGHTS OF WATCH TOWER AND OTHER ACCESSORIES OF GATE LIGHTS UNDER GE(AF) TECH AREA AGRA
2021_MES_417507_2
8200-1290/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹80,000
Yes
20 May 2021
12 Mar 2021
30 Mar 2021
12 Mar 2021
29 Mar 2021
15 Mar 2021
12 Mar 2021 - 13 Mar 2021
60 days
Amount
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soil complete all as specified and directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as specified and directed. Note : Thickness of sand will be measured after punning for payment purpose.
Taking out old serviceable/ unserviceable LT UG cables of any size of 10 to 25 sq mm, 2/3.5/4 core from trenches, poles/walls and floor includuing taking out old serviceablee bricks from trenches and relaying serviceable cable in trenches, poles complete all as specified and directed.
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete including taking down old unserviceable cable all as specified and as directed :-
(a)10 Sq mm 4 core
(b)16 Sq mm 4 core
(c) 25 Sq mm 4 core
(c) 35 Sq mm 3.5 core
M&L for drilling suitable dia horizontal bore holes suitable for insertion / laying of pipe up to 40 mm bore GI tubing of any description below/ under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing strata after laying pipes complete all as specified and directed.
Supply and fixing in repair of GI tubing light grade of 40 mm bore for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed.
Taking down carefully unserviceable LED street light, flood light fitting of any type from pole/wall/High mast dismantling and checking out serviceability of parts/circuit such as drivers, etc repalcement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including connecting, testing complete all as specified and directed. Note : New parts will be measured and paid separately under relevant items of BOQ as 'supply only'.
Supply only for driver suitable for LED light 25/30 Watt complete all as specified and directed.
Supply only for driver suitable for LED light 60 Watt complete all as specified and directed.
Supply only for driver suitable for LED light 150/250 Watt complete all as specified and directed.
Supply and fixing PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor flate/round including taking down from pole, wall and refixing in same position with fixing arrangement complete all as specified and directed of the following sizes:-
(a) 2 core, 1.5 Sqmm
(b) 2 core, 2.5 Sqmm
(c) 2 core, 4 Sqmm
(d) 2 core, 10 Sqmm
M&L labour for light grade GI pipe of size 20mm dia fixing on pole/wall for cable protection including fixing arrangement all as specified and directed.
Supply and fixing GI pipe street light bracket on LT /HT pole made out from 40 mm bore GI pipe light grade of 1.2 metre long and made to shape for fixing with suitable size of flat iron clamp, nut , bolts and washers including two coats of synethetic enamel paint over a coat of red oxide primer and fixed with existing street light fitting and making re-connection all the electrical connection including taking out the old unserviceable GI bracket complete all as specified and directed.
Supply and fixing in repair MCB 4 pole , 63 Amp rating of 10 KA on existing LT panel board/ high mast panel complete all as specified and directed.
Supply and fixing in repair MCB SPN 6 to 32 Amps, 230 volts, 10 KA with enclouser in existing street light panel/pole box complete all as specified and directed.
Repair/ maintenance of control panel of high mast light fitting complete with checking all electrical wiring and contactor including removing the old burnt control wiring from the panle and re-wiring with new PVC insulate copper cable single core multi strand with existing size and made the panel serviceable including testing after completion of work complete all as specified and directed.
Supply and fixing in repair LED landscape light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame , IP-65, 25 watt LED for gates with all fixing arrangements complete all as specified and directed. Make-Havells, Model No-RUBYPT25WLED830SSYMTOPC or equivalent in bajaj/Phillips/crompton as approved by GE.
Supply and fixing in repair of LED road way light fitting luminaires ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame , IP-65, 45 watt LED with 110LM/W complete all as specified and directed. Make- Crompton, Model No- LSTS-45-CDL-M or equivalent in Havells (Model No-ENDURACITYLITEPLATINUMPLUS45WLED) /Phillips/Bajaj as approved by GE.
Supply and fixing in repair LED road way light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame IP-66,50 watt LED complete all as specified and directed. Make- Bajaj, model No- BJFL50WLEDI or equivalent in Havells /Phillips/crompton as approved by GE.
Supply and fixing in repair of LED road way light fitting luminaires ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame, IP-66, 60 watt LED with SPD 10 KV , efficiency 110LM/W complete all as specified and directed. Make- Crompton, Model No- LSTP-60-CDL-MWW or equivalent in Havells (Model No-ENDURAPEARLNEO60WLED) /Phillips/Bajaj as approved by GE.
Supply and fixing in repair LED flood light fitting suitable fixing on high mast light including all fixing arrangement high grade aluminium pressure die cast and toughened glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of IP66 LED 80 watt warm white including taking down/out old unserviceable light fitting complete all as specified and directed. Make- Crompton, Model No- LFL-80-CDL/60-MWW or equivalent in Havells (Model No-JETAIRIS80W LED) /Phillips/Bajaj as approved by GE.
Supply and fixing in repair LED flood light fitting suitable for high mast light including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of IP66 LED 150 watt warm white complete all as specified and directed. Make- Crompton, Model No- LFLN-150-CDL/60-MWW or equivalent in Havells (Model No-JETAIRISFL150W LED 757PSYMT) /Phillips/Bajaj as approved by GE.
Supply and fixing in repair LED flood light fitting suitable for high mast light including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of IP 66 LED 200 watt complete all as specified and directed. Make- Crompton, Model No- LFLN-200-CDL/60-MWW or equivalent in Havells (Model No-JETAIRISMAXFL200W LED 757PWBLTG) /Phillips/Bajaj as approved by GE.
Supply, install and testing of high intensity, Energy saving, long range > 700mtr, multi function auto – swivel LED search cum flood light 1x300 watt, narrow beam-7 degree, LM6 housing with heat sink, round in shape dia>350mm, operating voltage 90V-300V AC 50 hz, PF>0.95 THD <10%, CCT:5500K-6000K, CRI>70, Optics used-PMMA/PC lens, LED efficacy>140 l/w average lux level at 10 mtr >5000 with circle of approx 1 mtr, toughened clear glass with silicon gasket, driver efficiency>90%, over volt/under volt & short circuit protected , confirming to LM79, LM80, IK07, IP66, and BIS. This search light will easy to installed on a unique rotating stang having such designed that the light could be rotate 360 degree & continuously (overnight) in the horizontal plane alongwith vertical tilting option upto 45 degree & covered by weather proof fiber box with provision of bottom hole for installation. A wall mounted wired control panel (consist of MCB, V-meter, fuse, LED indicator and having buttons for speed controller (1-10 rpm), auto/ manual, rev/ forw and up /down buttons) is supplied for safe operation. Make- KALIN MODEL NO-MRSL-LRFLL-25PC30, Note : (i) The working height of watch tower is min 15 mtr (ii) The contractor shall arrange the boom lift for carrying out the repair work. Contractor quoted rate deemed to be inclusive of this aspect. No extra charge shall be paid to contractor on this account.
Taking out old existing solar light fitting and refixing after necessary repair all as specified and directed. Note:- Unserviceable parts replaced shall be measured and paid separately as supply only.
(a) Supply only LED Security light 30 W suitabled for solar light with IP-65 Make- Surya or equivalent in HPL/Bajaj/Philips complete all as specified and directed
(b) Supply only solar light lithium ion battery min 11.1V/40Ah, suitable for Surya solar light 40 W complete all as specified and directed
(c) Supply only Solar light PV module suitable for 45W LED light having rating not less than 100Wp polycrystalline module Voc minimum of 21 V, suitable for Surya solar light 40 W complete all as specified and directed
Supply and fixing nature switch complete with timer , contactor, relays and suitable rating MCB s for incoming and out going in built in suitable sheet metal enclosurr of single phase integrated models of cpacity 8 KW including taking down/out old unserviceable nature switch complete all as specified and directed. Make : SWADEEP of Healer Enterprises or equivalent in shalabh (India) Ltd /L&T as approved by GE
M&L for aluminium lugs for LT cable connection line suitable for system and fixed complete including taking down old unserviceable lugs all as specified and directed of size 16 sqmm to 35 sqmm.
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down old existing comlete all as specified and directed.
Carryout day to day rectification of external electrifical complaints such as repair, reconnection and lightening of burnt/loose cable lead in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed.
Note : (a) 01 x Electrician and 01 x helper will be detailed by the contractor for attending above complaints daily basis cost for which shall be deemed to be included in quoted rates. (b) Replacement of major items shall be measured and paid under relevant items of this schedule. (c) Electrician and helper so detailed by the contractor will report to MES complaint cell at 0800 hrs morning to receive complaint slip from department and complaints shall be rectified within 08 hours. If contractor fails to detail above tradesmen, a panel recovery @ Rs 500.00 per day shall be made to the contractor and the same shall be recovered from RAR/final bill. (d) Repairing upto 03 points at different electrical system without any other material will be considered as one job.
Balaji Associate
M/s Sumer Associates
GUPTA ENGINEERING WORKS
D K Bhugra and Brothers
AUTOMATION AND SWITCHGEAR CONTROL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .