PROVISION OF 5 X HIGH MAST LIGHTS AT GHITORNI LOCATION (RESTRICTED OUTSTATION) UNDER GE (SOUTH WEST) NEW DELHI-03
2024_MES_667588_1
GE/SW-41/2024-25
Limited
Electrical and Maintenance Works
Item Rate
180 days
GE (South West) New Delhi
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE (South West) New Delhi
₹94,600
Yes
26 Sept 2024
3 Sept 2024
26 Sept 2024
3 Sept 2024
24 Sept 2024
17 Sept 2024
Amount
Supply, erect, test and commissioning of minimum 16 metre high mast system with its accessories. Mast shall be in two sections, hot dip galvanized and suitable for wind velocity 70 M/ sec as per IS 875 part 3. It shall consist of GI lantern carriage suitable for 8 luminaires symmetrically & their control gear boxes and lighting finial, double drum winch with both motor and manual operation, suspension system with SS wire rope 6mm dia (7/19 construction), trailing cable of flexible copper conductor cable 5 core 2.5sq.mm (minimum), torque limiter adjustable type & 01 No. aviation obstruction light (LED type). The mast shall have an integral power tool with reversible option installed inside the base compartment for its operation complete all as specified and as directed. Make: Bajaj/ C.G/ Philips.
Note: The rate quoted shall be inclusive of the following:- (a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set (b) Supply of control panel housing suitable control circuit for the operation of the mast made out of 3mm thick CRCA sheet, double door type with slopy canopy suitable for outdoor installation. It shall also consist of suitable control for the power tool motor -01 No with suitable switchgear and wiring from panel to light fittings with suitable copper conductor cable, glands, lugs including suitable foundation - 01 Job (c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour (d) Erection and commissioning of the high mast with the help of suitable equipment. (e) Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour. Note: The LED flood light fittings required will be measured and paid separately under relevant Schedule items.
HIGH MAST SYSTEM Make : Bajaj Electricals Ltd. Height of mast : 16 Meter No. of sections : Two Material construction : HR Sheet Base dia. and top diameter (A/F) : Top : 150 mm Plate thickness : Top 3 Cross section of Mast : 20 side polygon Standard for of galvanisation : As per BS EN ISO 1461 Size of opening and door at base : 1200 x 250 mm Diameter of base plate : 570 mm Thickness of base plate : 25 mm Lightning protection finial : G.I single spike Max. wind speed : 47m/s as per IS : 875 (Part - III) Number of foundation bolts : 8 Nos PCD of foundation bolts : 490 mm Type / diameter / length of foundation bolts : TS 600 / 30 mm dia / 850 mm long.
LUMINAIRES CARRIAGE Material of construction : 50 NB ERW Class B - M. S. Pipe Diameter of carriage ring (mm) : As per design Construction : As per design Load carrying capacity : 10 Luminaire asymmetrical
TRAILING CABLE Conductor : Copper, 5 core, 4 sq mm Insulation : EPR insulated PCP Sheathed No. of circuits per mast : One no. cable per mast
WINCH / POWER TOOL Type / SWL of winch : Double drum, SWL 500 Kg Method of operation : Integral Motor Motor capacity : 1 HP No of speeds : 6 Pole, Single speed Torque limitor : With mechanical tripping facility
STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 construction Number of ropes : Two continuous Diameter (mm) : 6mm Breaking load capacity : 2350 kg x 2
FOUNDATION DETAILS i) Excavation dimensions 2800 x 2800 x 1500mm size ii) Lean Concrete 100 mm thick ( 1: 4: 8) D2 (using 40mm graded Aggregate) iii) Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers iv) RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing v) RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) vi) 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars vii) 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. viii) 10mm dia TMT bars @ 150mm C/C as Stirrups ix) 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. x) Foundation bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanished nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note: The unit rate is inclusive of necessary formwork, RFR removal of surplus earth, external finishes and other unforeseen items all as directed by Engr- in-Charge.
Supply only 150W LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 18500 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 and external SPD of capacity 10 KV in addition to inbuilt SPD of electronic driver. Make: M/s Bajaj 150W LED or equivalent in M/s Philips / CG
Supply & lay or fixing or passing through pipe or in cable ducts, 1100 volts grade, XLPE, armoured, electric power cables (heavy duty) with aluminium conductor of size 35 Sqmm 3.5 Core.
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings/ plinth protection with fixed to the pole wall etc. suitable fittings for cable protection.
Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft and loose soil complete all as specified and directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, Supply and lay cable cover LV type flate size 250 X 150 X 40 mm.
Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
Supply of outdoor, made of 14 SWG CRCA sheet, IP-55, stand mounted feeder pillar with 1 no. 32A TPN MCB incomer, single dial time switch, 22A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals.
Supply, installation, commissioning and testing of Aviation obstruction light BGAV302LED make : Bajaj insta power red painted housing, Red coloured Polycarbonate dome and accessories complete all as specified and directed by Engr-in-Charge (01 fitting required per high Mast).
GLIBS CONSTRUCTION (BID ID -3110081)
M/s VINOD KUMAR SHARMA (BID ID -3111012)
JYOTI CONTRACTORS AND TRADERS (BID ID -3107353)
M/S ANIL KUMAR (BID ID -3098819)
Rahul Enterprises (BID ID -3100425)
Saini Enterprises (BID ID -3110352)
Vishal Traders (BID ID -3103834)
R R Associates (BID ID -3099951)
Leo Air and Power Solution pvt Ltd. (BID ID -3110511)
J D ENTERPRISES (BID ID -3111108)
Surjit and Sons (BID ID -3109236)
Pradeep Bros (BID ID -3106327)
M/s Dhapola Elevator and Engineering (BID ID -3111386)
SANJEEV ENTERPRISES (BID ID -3102197)
SB ENTERPRISES (BID ID -3107515)
KRISHANA ELECTRIC WORKS (BID ID -3099729)
JIWAN DASS THAREJA AND SONS (BID ID -3109701)
VINAY ENTERPRISES (BID ID -3107528)
RUCHIKA ENGG.WORKS (BID ID -3111796)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .