| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹14.6 L+₹1.7 L (13.5%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹15.5 L+₹2.6 L (20.0%)Rejected-Finance VPO MAJOD TEHSIL HANSI DISTRICT HISAR 125049 HARYANA | HISAR | HISAR | HARYANA | 125049 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹17.0 L+₹4.1 L (31.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical No, the firm is not having the requisite Cat ie a (i) |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
24 Oct 2024, 6:00 pmClosed
GE HISAR
GE HISAR
CA NO GE(H)-54/2024-25 REPAIR TO SEWAGE LINE, MANHOLE SEPTIC TANK, SOKAGE WELL AND ATTENDING DAY TO DAY SEWER COMPLAINT IN MARRIED ACCN IN THE AOR OF AGE B/R-I UNDER GE HISAR AT HISAR MIL STN
2024_MES_676627_1
CA NO GE(H)-54/2024-25
Open Tender
Civil Works
Item Rate
300 days
Hisar
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹50,000
Yes
9 Dec 2024
26 Sept 2024
26 Oct 2024
26 Sept 2024
24 Oct 2024
10 Oct 2024
Amount
M&L for attending complaints pertaining to essential cleaning of RCC sewage line upto 200mm dia through day to day maintenance by rodding / auger rods / drain pipe machine as required from manhole to manhole including gully trap with and including dewatering of contiminated waste effluent & getting out the sludge if required by using suitable method during cleaning process from any size of manhole & gully trap before & after cleaning process of RCC sewage line and well flushing using clean water through water bowser pipe of any capacity (water bowser shall be arranged by the contractor) and removing the sludge etc to a distance not exc 250m and burying the same underground by digging pit of suitable size from habitant area and returning & filling with excavated material upto ground level including removal of sludge soil to a distance not exc 250m with and including taking off manholes / gully trap covers and refixing the same after cleaning process complete all as specified and directed. Note :- The measurement of EACH JOB will be covered the length between one to another manhole inclding cleaning of manholes. The rate quoted against the item shall deemed to be included all M&L and T&P required.
M&L for cleaning / taking off of sludge of any state (solid / semi soild & other similar materials etc) through day to day maintenance from manhole of any size including gully trap having depth not exc 4m by using machinary or manually as required and removing the same to a distance not exc 250m and burried the same underground by digging pit of suitable size from habitant area and returning & filling with excavated earth upto ground level including removal of surplus soil to a distance not exc 250m complete including taking off manholes / gully trap covers & re-fixing the same after cleaning process complete all as specified and directed. Note :- The rate quoted against the item shall deemed to be included all M&L and T&P required.
M&L for attending complaints pertaining to essential opening / cleaning of blocked WC of any type, traps and CI / PVC drain pipe including fittings (i.e. access door bends/ Tees etc) of any size and at any position through day to day maintenance with and including taking down CI / CP / PVC grating and refixing the same at position with suitable material / fitting i.e. white cement, solvent, nut & bolts etc and well flushing, pressure pumping, taking out all residue materials etc and removing the same to a distance not exc 250m and burried the same underground by digging pit of suitable size from habitant area and covering the same by returning & filling with excavated material upto ground level including removal of surplus soil to a distance not exc 250m complete all as specified and directed. Note :- The rate quoted against the item shall deemed to be included all M&L and T&P required.
S&F in repair factory made (SFRC) precasted reinforced cement concrete round manhole cover as required thickness not less than 100mm for heavy duty and dia of manhole cover not less than 630mm, edge of manhole cover locked with 1mm thick MS sheet complete all as specified and directed.
S&F in repair factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 50mm of size 700mm x 550mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed.
S&F in repair factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 50mm of size 350mm x 350mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces of walls, finished even and fair including mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement complete all as specified and directed
Supply only liquid water proofing compound
Demolition of reinforced cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
M&L for Reinforced cement concrete Type B1 1:2:4 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
M&L for PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels/ bottom of manhole complete all as specified and directed.
M&L preparation of new untreated surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed by Engr-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.
S&F 110 mm PVC (SWR) bends any radius complete all as specified and directed.
S&F 75 mm PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.
S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.
Taking down and refixing after repairing cast iron pipe 100mm bore fixed to walls with necessary fittings/ connection/ heads/ shoes/ bends/ swan neck etc & MS clamps/ clip and necessary screwing as required in new or old position complete all as specified and directed.
Taking down and refixing after repairing cast iron pipe 75mm bore fixed to walls with necessary fittings/ connection/ heads/ shoes/ bends/ swan neck etc & MS clamps/ clip and necessary screwing as required in new or old position complete all as specified and directed.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for removing existing branch drain, making good to walling and rendering, cutting out branch channel, and making good benchings as required for 150mm bore pipes complete all as specified and as directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm bore pipes complete all as specified and as directed.
M&L for 150mm bore Sail-glazed stoneware drain pipes laid in trenches and jointed complete all as specified with collars and as directed.
M&L for cement Concrete Type C2 (1:4:8) (using 40mm graded aggregate) bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Shiva Constructin Co. (BID ID -3141121)
VIKAS INFRASTRUCTURE (BID ID -3148556)
S K BUILDERS (BID ID -3147900)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .