Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.1 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹18.1 L | 1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | 2₹18.8 L+₹68,101 (3.76%)Rejected-Finance | ₹18.8 L+₹68,101 (3.76%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹18.9 L+₹81,235 (4.48%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹18.9 L+₹81,235 (4.48%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹19.2 L+₹1.1 L (6.25%)Rejected-Finance | ₹19.2 L+₹1.1 L (6.25%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹20.7 L+₹2.6 L (14.3%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | ₹20.7 L+₹2.6 L (14.3%) | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Jul 2021, 6:00 pmClosed
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
MISC REPAIRS AND REWIRING OF INTERNAL ELECTRIFICATION SERVICES AS WELL AS ATTEND MAINTANANCE PROGRAMME IN NEW CANTT AREA OTM ACCN AT PATIALA MIL STN
2021_MES_443464_2
GE(N)/PAT-15/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹50,000
Yes
5 Aug 2021
24 Jun 2021
10 Jul 2021
24 Jun 2021
8 Jul 2021
24 Jun 2021
Amount
Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including NEW PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. Notes: (i) Cost of switches socket, regulators, Terminal Boxes and Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth(ii) pressed modular steel terminal boxes and top modular cover plate of suitable size included in point wiring. Make of Wire: Havells/Finolex/Polycab
All as per Sl item No 2.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. Make of Wire: Havells/Finolex/Polycab
All as per Sl item No 2.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. Make of Wire: Havells/Finolex/Polycab
All as per item No.2.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 1.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for switch socket combination 3 pin 15 amps on independent board. Make of Wire: Havells/Finolex/Polycab
Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in EXISTING PVC rigid non metallic concealed conduit to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified. Notes: (i) Cost of switches socket, regulators, Terminal Boxes and Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth(ii) pressed modular steel terminal boxes and top modular cover plate of suitable size included in point wiring. Make of Wire: Havells/Finolex/Polycab
All as per Sl item No 6.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. Make of Wire: Havells/Finolex/Polycab
All as per Sl item No 6.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. Make of Wire: Havells/Finolex/Polycab
All as per item No.6.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 1.5 Sqmm PVC insulated and unsheathed FRLS copper earth wire for switch socket combination 3 pin 15 amps on independent board. Make of Wire: Havells/Finolex/Polycab
Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Modular bell push switch 1 way, 6 Amps, 1 module complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed
S&F blank plate wherever required all as specified & directed
S & F Lamp holder incl flexible wire 0.5 Sqmm copper cable all as specified & directed. Make of Wire: Havells/Finolex/Polycab
Taking down unserviceable building security light fitting of any size/type and supply and fixing of powder coated pressure die cast aluminium compact LED security light fitting of 25 watt with LED lamps including mounting arrangement i.e GI pipe of suitable size, clamps, nuts bolts complete all as specified & directed. Make: Philips/Bajaj/Havelles/Wipro/Crompton
S& F LED ceiling light 36 Watt any colour light as required complete fixeed as in repair all as specified. Make: Philips/Bajaj/Havelles/Wipro/Crompton
S& F LED ceiling light 50 Watt any colour light complete fixeed as in repair all as specified. Make: Philips/Bajaj/Havelles/Wipro/Crompton
S&F LED bulkhead light fitting with 10/12 watt LED lamp all as specified & directed Make: Philips/Bajaj/Havelles/Wipro/Crompton
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade (main cable : number of runs indicated below) along with one run of single core FRLS PVC insulated flexible solid/multistranded copper conductor 1.1 KV grade for earthing in and including PVC conduits of suitable size, for 2 runs of 6 sq. mm main cable + 1 run of 4 Sq. mm earth cable as in replacement of old unserviceable wiring complete all as specified and directed. Note: (i) Two different color wires shall be used for phase and neutral . (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) If Necessary cutting chasing shall be included in this item. Make of wires : Finolex/Havells/Polycab
Supply and fix Modular switch 1 way, 6 Amps, 1 module, 230 volts make and fitment as per gound requirement complete all as specified.NOTE-contractor shall visit the site to check make and size of item. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Supply and fix Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider NOTE-contractor shall visit the site to check make and size of item.
Supply and fix Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider NOTE-contractor shall visit the site to check make and size of item.
MCCB, B Curve, TPN, 100 Amps, 4 pole 415 volts, 16 Ka complete fixed as in repair all as specified and directed. (Note: MCCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Load line distribution board TPN, Vertical 4 ways, double door, powder coated DB and provision for MCCB/MCBs, including necessary earth bar and neutral link 200 Amp, and complete with provision of MCB (out going) with adjustable release complete fixed as in repair all as specified. (Note: MCB/MCCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
MCB, single pole (SP) 10 KA 240 volts, 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
MCB, single pole & neutral (SPN) 10 KA 240 volts, 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Load line distribution board SPN, 8 ways, 240 volts with 200 Amps standard bus bar of suitable size, double door, powder coated sheet metal enclosure fitted with bus bar din and neutral link, and provision for accessories such as Isolators and MCB (out going) , with adjustable release complete fixed as in repair all as specified. (Note: MCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
MCB, single pole & neutral (SPN) 10 KA 240 volts 20 to 40 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
MCB, single pole (SP) 10 KA 240 volts 6 to 32 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge) Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Earthing complete with copper earth plate electrode of size 600x600x3.15 mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to 20X 3 mm copper strip as earth lead by means of bolts , nuts , check nuts and copper including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497.
Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497.
RCBO, double pole (DP) 300mA, 240 volts 16 to 32 Amp capacity for earth leakage protection,overload & short circuit protection fixing in DB’s complete all as specified and directed. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
RCBO, double pole (DP) 300mA, 240 volts 40 to 63 Amp capacity for earth leakage protection,overload & short circuit protection fixing in DB’s complete all as specified and directed. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
RCBO, four pole (FP) 300mA, 240 volts 16 to 63 Amp capacity for earth leakage protection,overload & short circuit protection fixing in DB’s complete all as specified and directed. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Supply only PVC gangbox 15 amp 2 switch and 2 socket 15 amp all as specified Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Supply only PVC gangbox 5 amp 2 switch and 2 socket 5 amp all as specified. Make: ABB/Havells/Legrand/Ave-Anchor/Schneider
Fixing only LED tube of any type ,watt complete all as specified and directed. Note- tube light any watt shall be issued for free for fixing under sch "B"
UNITED ENGINEERING CORPORATION
m/s s.n. builders
M/s Anil Kumar and co.
Arun enterprises
Jawandha Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .