Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹10.7 L+₹70,254.50 (7.01%)Rejected-AOC | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹10.8 L+₹77,212.50 (7.71%)Rejected-AOC | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹10.8 L+₹78,220.80 (7.81%)Rejected-AOC | L4 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 5 | L5₹10.8 L+₹83,122 (8.30%)Rejected-AOC | L5 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
14 Dec 2019, 6:00 pmClosed
CWE Mamun
HQ CWE Mamun Pathankot Pin 145001
SPECIAL REPAIR IN BLDG NO P-55 OF OTM ACCN ACCN UNDER GE (NORTH) MAMUN AT MAMUN MIL STATION
2019_MES_299313_1
CWE/M-32/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE (North) Mamun
Class E Category a I
7 documents required · 7 mandatory
₹500
GE (North) Mamun
₹31,000
Yes
21 Jan 2020
20 Nov 2019
16 Dec 2019
20 Nov 2019
14 Dec 2019
9 Dec 2019
Amount
Taking down chowkhats or frames of any description not exc 1.50 Sqm each with shutters, (without taking off shutters from the frame) including builders hardware , complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Vitreous china wash hand basin, white, flat back, size 550x400mm (Make : Jaquar Cat part No CNS-WHT-801 or equivalent model in Hindware/Parryware/Somany) including 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated (Make : Jaquar Cat part No FLR-5011N or equivalent model in Hindware/Marc.) brackets, CP waste coupling, 32mm bore PVC waste pipe of min 600mm long & 15 mm bore PVC connections, including cutting for and pinning in end of brackets or erecting stand fixed in repairs complete all as specified and directed.
S&F in repair for Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball and dismantling of existing PVC tank of any capacity, complete all as specified & directed.
S&F in repair for 15mm bore bib taps fancy type with wall flange, chromium plated cast copper alloy long body with capstan heads, screwed for iron pipe or brass ferrule complete all as specified and directed.
Taking up or down 15mm bore pipe and connections including cleaning for refixing including all new fittings for 15mm bore complete all as specified & as directed.
Taking up or down 20mm bore pipe and connections including cleaning for refixing including all new fittings for 20mm bore complete all as specified & as directed.
M&L for GI water tubing surface/concealed, 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Refixing of old steel tubing 15mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) fixed to wall , floor etc complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as specified & directed.
M&L for GI water tubing surface/concealed, 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concealed portion of tubing, fixed to wall or ceiling or laid in floor, including taking down existing unserviceable GI tubing and connections complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
Refixing of old steel tubing 20 mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) fixed to wall , floor etc complete all as specified and directed. (Note : Cutting chases and making good shall be measured and paid separately)
S&F 15 mm bore Stop valves/Angle valve cast copper alloy, chromium plated (ISI marked) , screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
M&L for rendering 10mm thick on brick work or concrete surface in CM (1:6) on wall surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises complete all as specified & directed.
M&L for rendering 5mm thick cement plaster on concrete surfaces on ceiling / chajjas in cement mortar 1:3, surface finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises, etc complete all as specified & directed. (Note : WPC shall be measured and paid separately) complete all as specified & directed.
M&L for Rendering 15mm thick in two layers (base layer 10mm & finishing layer 5mm thick) in cement mortar (1:4) using liquid water proofing compound on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement including taking down cement or cement lime plaster of any description and raking out joints, hacking for key, scrubbing down with water and removal of rubbish, out off the premises, etc complete all as specified & directed. (Note : WPC shall be measured and paid separately)
M&L for rendering or plastering work 10mm thick in CM (1:3) in fascia / edging / ceiling of Chajjas, roof projections and making the line in true shape and finishing the surface without using extra cement, complete all as specified and directed
M&L for Preparation of new plastered surface of external wall and chajjas and making the surface smooth with sand paper and priming the surface with primer as per recommendation of manufacturer for external surface, over primed surface applying two coat of cement base paint complete all as specified & directed.
M&L for Preparing new wall surface including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of acrylic , antifungal emulsion exterior weather proof paint over a coat of primer as per manufacturer recommendation on external surfaces, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of primer as per manufacturer instructions (from same manufacturer of OBD) over a layer of wall care putty 3mm thick complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and apply three coats of white wash on plastered surfaces complete all as specified and directed.
M&L for Cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregates) such as in benching, coping, Bed blocks , broken chajjas and the like, rounded or chamfered on edges including necessary formwork including demolition of existing concrete of any description and removal of debris out off the premises etc complete all as specified and directed.
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.
S&F Stainless steel wire cloth 0.42 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks, orstainless steel wire staples complete all as specified and directed.
M&L for Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side hung wire gauged shutter & glass/glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg, welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts fixed in PCC blocks all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 60mm thick factory made rubberised coloured (laminated) interlocking paver block (using vibro compaction method) (topping thickness not less than 5mm) in white cement and non fadable glossy pigment of approved shade of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including cleaned dry sand cushion 50mm thick over and including demolition of damaged cement concrete of any type or description and removal of debris out off the premises etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and smooth using extra cement including demolition of damaged plinth protection and removal of debris out off the premises etc complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joint free tiles 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) incl roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.& brushing with neat cement slurry @ 3 Kg/sqm complete all as specified and directed.
M&L for Non-skid ceramic coloured rectified edges joints free tiles 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in skirting/dado/riser of steps etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4) including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises, etc complete all as specified and directed.
M&L for Glazed ceramic (coloured) tiles 7mm thick, of size 450mmx300mm on vertical surfaces such as dado etc, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match tiles over and including 10mm thick backing coat in cement mortar (1:4), surface finished even and rough to receive tiles, including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises complete all as specified and directed.
M&L for 12mm thick Endura brand (Johnson) or equivalent model in Kajaria/ Somany as approved by GE , exterior floor tiles (Square or rectangular) area of each tile exc 0.08 Sqm but not exc. 0.18 Sqm in floors , set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) (surface finished even and rough to receive Endura tile) including dismantling existing tiles of any type and pattern including cement mortar backing coat and removal of rubbish out off the premises, complete all as specified and directed.
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Taking down brick tiles or terracing tiles, single layer from roof laid, bedded and pointed in any mortar complete all as specified and directed.
Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete: push pull or manual type including taking down of existing rolling shutter complete all as specified and directed.
M&L for Brick work with Fly Ash Brick (Non-Modular) straight or curved on plan exceeding 6m mean radius built in CM (1:4) including dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, and removal of rubbish out off the premises, complete all as specified and directed.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S&F ball bearing for rolling shutters complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as leveling course/padding using water proofing compound laid over existing roof, surface finished rough to receive cement mortar including necessary formwork including demolition of existing concrete of any description and removal of debris out off the premises complete all as specified and directed. (WPC shall measured and paid separately)
M&L 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr.Fixit or STP as per manufacturer instruction @ 0.200 Ltr in 50 kg of cement, complete all as specified and directed.
M&L for preparation of new painted steel surfaces of any description over 10 cm in width or girth & applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer not otherwise described including rubbing out and cleaning rust on new steel surfaces complete all as specified and directed.
M&L for providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in floor/subbase and finished even and fair complete all as specified.
M&L for RCC 1:1½:3 using 20mm graded crushed stone aggregate as in chajjas, facias including demolition of existing chajja/facias and removal of rubbish out off the premises etc complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
M&L for RCC1:1½:3 using 20mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including demolition of existing cover slabs of any description and removal of rubbish out off the premises etc complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately)
Form work to sides of soffits and floors or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhanges etc also splays between floors and beams for fair finished concrete surface of concrete complete all as specified and directed.
Form work to chullah hoods, chajjas, toughs & similar items including edges rough finished surface of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down carefully unserviciable/ damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.
M&L for Modular Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)
All as per Srl item No. 50 above but for 5 pin 5 Amp socket outlet point on independent gang box and suitable support frame and cover plate (inner/outer) controlled by one switch 5Amp one way, etc complete all as specified and directed.
All as per Srl item No. 50 above but for 5 Pin 5 Amp socket outlet point on same board controlled by one switch 5 Amps one way on same gang box support frame and cover plate etc complete all as specified and directed.
All as per Srl item No. 50 above but for one 15Amp socket outlet point concealed using 2.5Sqmm FRLS PVC insulated multi-strand copper conductor wire including 2.5Sqmm FRLS PVC insulated unsheathed copper conductor earth wire and making good to disturbed surfaces of wall floor to match existing finishes complete all as specified and directed.
S&F Modular Switch 1 way 16 Amps , 1 module etc complete , all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVSXXW161 /Legrand Cat Part No 673411/ Schenider Cat Part No P1101.
S&F Modular Socket outlet, 5 pin, multi purpose, 2 module 6/16 Amp, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKCWW163 Legrand Cat Part No 673455 / Schenider Cat Part No P2106.
S&F Modular Switch 1 way 6/10 Amps , 1 module etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVSXXW101, Legrand Cat Part No 673401, Anchor Roma Cat Par No 289101, Schenider Cat Part No P1001.
S&F Modular Socket outlet, 5 pin, multi purpose 2 module 6 Amps, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKSWW065 /Legrand Cat Part No 673452/ Schenider Cat Part No P2005.
S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 65 x 50 mm, three terminals, AC 230 volts etc, complete all as specified and directed. Make : Havells Cat Part No Reo/Cona Cat Part No 9246/GM Cat Part No 8224
S&F Lamp holder insulated body with back plate suitable for batten fitting including 14W LED lamp of approved make and cat part and PVC Round/Square block etc complete all as specifeid and directed.
Taking down ceiling fan of any sweep & size and refix in same position after overhauling including minor repairs by replacement of capacitor, safety pin, cap, nuts & bolts etc and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose to fan, including testing to ensure efficient functioning including application of one coat of synthetic enamel paint by spray painting & rewriting number complete all as specified and directed.
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed. Make : Legrand Cat Part No 673028/Crabtree Cat Part No ACARFHW005/Anchor Roma Cat Part No 66502.
S &F the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed.
M&L for Surface mounted 1x20 watt LED tube light fittings (4 feet long), prewired, decorative luminaire with inbuilt LED tube rod and acrylic end covers with all accessories and PVC Round/Square block for fixing of fittings and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S&F the wall mounted type fancy light fitting with 8 watt LED bulb and with decorative diffuser and mounting clips and lamp holder , wall mounting arrangment complete all as specified and directed.
S & F mirror light 7 watt LED type with all accessories including inbuilt lamp connecting electrically to ceiling rose using cord flexible 3core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed. Notes for Srl Item Nos 62 to 65:- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be > 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 11. CA No shall be written on each fitting before installation.
S&F double door MCB DB made out of 18 SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 2+6 way double door open able complete, including taking out old unsv MCB DB any size/type complete all as specified and directed.
S&F for MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) , complete all as specified and directed. Make : Legrand/Schneider/Hager
S&F for MCB single pole neutral (SPN) 240 volts, 40 to 63 Amps, 10KA (C-series) complete all as specified and directed. Make : Legrand/Schneider/Hager
M&L for Sub main wiring with FRLS PVC insulated unsheathed 2X6 sqmm multistranded copper conductor cable 1100 V with 1X6 sqmm FRLS PVC insulated green multistranded copper cable for continuous earth drawn through & including concealed PVC conduit of appropriate size not less than 20 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring complete all as specified and directed. (Note: Two runs of FRLS PVC cable with one run of earth conductor and conduit shall be measured as one RM.) Make for wiring : Polycab/Anchor/Finolex
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 16 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable & bricks complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
S&F for GI tubing 40 mm bore light grade laid in trenches/floors/ fixed to wall/poles for protection of cable with necessary fittings and FI clamps duly painted complete all as specified and directed.
Raghbir chand
dadwal engineers
M/S BHOTO AND CO
M/s. RAMESH KUMAR
M/S DUGGAL CONSTRUCTION CO
A V BUILDERS
surjit enterprises
M/S J N TRADERS
M S Associates
Ms Tarsem Kumar Sharma
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .