RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Portable Ventilator ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards UMDNS Code 18-098 * Certifications for the product EU CE US FDA
RequiredEU CE
RequiredBoth US FDA & EU CE
RequiredBIS Certification number and date - * Confirmity to quality ISO 9001 & ISO 13485 ISO 9001 & ISO 13485
Required1/6 management standards ICMED 9001 & 13485 Confirmity to electrical safety standards IEC 60601-1 or ISO 80601-2-12 or BIS equivalent * Vibration resistance certification Not available EN 794-3
RequiredNot available Aviation Standards: NA in case not compatible for air craft use Should have airworthiness as per RTCA DO-160D aviation standards
RequiredNA in case not compatible for air craft use Performance Parameters Scope of item Portable transport ventilators are defined as mechanical ventilators that are specifically designed to facilitate intrahospital and/or interfacility transport of ventilated patients. These devices are relatively small and lightweight
Requiredand can be hand-carried if necessary during transport. Transport ventilators may provide basic or advanced modes of ventilation for neonatal
Requiredpediatric
Requiredand/or adult patients * Clinical application Portable transport ventilators are designed to take the place of manual ventilation or "bagging" during emergency or transport situations * Patient type Adult & pediatric Adult & pediatric
RequiredPediatric and neonatal Tidal volume in ml 50 ml or less - 1500 ml or more 50 ml or less - 1500 ml or more
Required20 ml or less- 300 ml or more Respiration rate
Requiredbreaths/min Upto 80 * Trigger mechanism Pressure or flow * FiO2 % 21-100 * Inspiratory flow rate
RequiredL/min Upto 120 * Inspiratory pressure
RequiredUpto 50 * 2/6 cm H2O IE ratio 1:3 to 1:1 1:3 to 1:1
RequiredAdjustable or infinitely variable PEEP/CPAP
Requiredcm H2O 0-20 * Pressure support
Requiredcm H2O Upto 35 or more * Panel lock Yes * Operating modes Assist/control modes A/C volume breaths and A/C pressure breaths * SIMV modes SIMV volume breaths
RequiredSIMV pressure breaths
RequiredSpontaneous/CPAP mode
RequiredCPAP pressure support
RequiredNon-invasive ventilation
RequiredApnea- backup vent mode * Monitored/Displayed Parameters Peak inspiratory pressure
RequiredMean airway pressure
RequiredPEEP pressure
RequiredTidal volume
RequiredMinute volume
RequiredFiO2
RequiredRespiratory rate
RequiredInspiratory time
RequiredExpiratory time
RequiredIE ratio * Patient Alarms Low/high FiO2
RequiredLow/high minute volume
RequiredLow inspiratory pressure
RequiredHigh pressure
RequiredLow PEEP
RequiredHigh PEEP
RequiredApnea
RequiredContinuous high pressure/occlusion
RequiredInverse IE
RequiredHigh respiratory rate
RequiredBreathing circuit disconnect * Equipment Alarms Gas-supply failure
RequiredPower failure
RequiredVent inoperative
RequiredLow battery
RequiredSelf-diagnostic * Type of display LCD LCD
RequiredLED
RequiredTFT Size of display in inches 7 * Patient Transport Capability Mounting of the equipment Rail mounted Rail mounted
RequiredTrolley mounted Rail mount or trolley mount should be of the same OEM Yes * Hand carrying during transport Yes * 3/6 MRI compatibility of equipment No Yes
RequiredNo Magnetic field strength
RequiredT NA for non MRI compatible 3 T
RequiredNA for non MRI compatible Guass line restriction in G (in case of non MRI compatible put NA) - * Built in air source Turbine Air compressor
RequiredTurbine Should work with External high pressure source/cylinders and low flow Oxygen supply * Power source Mains and battery operated Battery operated
RequiredMains and battery operated Battery type Li-ion * Should be able to work with car ambulance battery No Yes
RequiredNo Power supply 220-240 V
Required50 Hz AV single phase 220-240 V
Required50 Hz AV single phase
RequiredNA for battery operated Operating time in hrs More than 5 hrs More than 3 hrs
RequiredMore than 5 hrs Weight (including battery) in kgs 5.3 * Warranty in years 3 3
Required5 Additional Accessories Reusable silicon breathing circuits 1 Adult
Required1 pediatric
Required1 neonatal 1 Adult
Required1 pediatric
Required1 neonatal
Required2 adult
Required2 pediatric
Required2 neonatal NV mask 1 Adult
Required1 pediatric
Required1 neonatal 1 Adult
Required1 pediatric
Required1 neonatal
Required2 adult
Required2 pediatric
Required2 neonatal Length of Power cord in m 3 m * Charging adapter to be supplied Yes * Reports Number of supplies in Central/State/PSU Govt Hospitals ( Hint: Seller should supply a performace certificate of the device to the buyer incase demaneded after placement of order) >3 0
Required<3
Required>3 OEM/Reseller ( if supplied by reseller Yes * 4/6 shall ensure uninterputed availabilty of all spares for 10 years) Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes * User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Demonstration of equipment and training to be provided after completing supplies before acceptance Yes * The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.