Construction of Integrated Public Health Unit IPHL Sader Hospital in Ranchi
2024_NREPR_86694_1
NREP1/49/23-24
Open Tender
Civil Works
Item Rate
270 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
₹1.6 L
Yes
24 Aug 2024
19 Jun 2024
26 Jun 2024
19 Jun 2024
25 Jun 2024
19 Jun 2024
Amount
SITC of AC-425IP-8E + MD-D048 AC-4251P-8E + MD-D048 installed within ME-10 15 enclosure. 8 wiegand reader controller. 8 inputs and 8 output Power plug and supports Full-Safe cable locks, for secured wiring, option of DIN rail 1 mounting. Cable twist locks and zip-tie anchors for better cable management. tamper sensing, and power status LED. single/ dual door modes, networked up to 1023 panels. Full online/offline operation. 30,000 Users 20,000 event history. Including software configuration, training, documentation & handover.
SITC of AYK6255BT MST MiFate & Bluetooth reader
Supplying & laying of 4 core Signal cable
SITC of EM Lock/Strike Lock with mounting angle & accessories
SITC of Exit Switch (kit)
Providing and fixing DC Power supply
Providing and fixing of Luck
Providing and fixing of Reader
Providing and fixing of Controller
Hermetically Sealed Sliding Door System: Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed door having high density particle board cores/ CFC free Polyurethane, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H) as per direction of EIC. Automatic Doors: Provided with Radar Switch 2 Nos., Foot Switch 2 Nos. and Photocell Sensors. Automatic Door (1500 mm x 2100 mm) Approved makes -Metaflex /REBBON / MDD Engineering/ Altos / Dormed/Meditech
Supply, installation, testing and commissioning of modular OT Walland corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using Gl puff panels having 0.8 mm thick Gl sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. . 60 mmlong SS fasteners which shall be fully threaded panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together bySS. The wall panel design shall be such that it enables the installation and supports all equipment's. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. Thework should be executed as per the directions of Engineer-in-Charge.
Supply, installation, testing and commissioning of modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using Gi puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0 80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. . All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel jcints shall not be visible after the final wall coating is applied..Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer-in-Charge.
Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type/c appropriate hardner and filler material. with 5 year defect liability period. 3mm thick
Supply Installation, testing & commissioning of Air Cooled Ductaile Split Units, Cutdoor & Indoor unit shall connected with DX coil. refrigerant piping, firstcharge of refrigerant & oil, HP/LP cutout, thermostatic expansion valve, distributor, starter and other necessary controls to form a factory tested compact urat. The outdoor unit shall have condenser coil, fans with motor & drive, copleandi scroll compressors, panel etc. The ductable units should be complete with programabile microprocessor panel (BMS) Compatible). (Make: LG/Blue Star / Daikin) 8.5 TR With Scroll Compessor
FFU-625 CFM with Hepa Filter, 40 MM of WC
FFU-950 CFM with Hepa Filter, 40 MM of WC
FFU-1100 CFM with Hepa Filter, 40 MM of WC
Supply instaliation and testing of powder coated aluminium extrudien grills/diffusers as per specifications given in tender and of following sites. Single Louvered supply / Return Air registers (Grill)
Supply/return suare ceiling air terminals (diffusers)
Fresir/Exileust air louvers with bird screen & barnper
Flexible connection for AHU/FCU mageup of f/ fabric compete with flange
Supply, installation and testing of blade type Ga Duct Damper for duct/collars to be provided with suitable anis and quadrants for control of volume of air
Supply and Application . Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open celi foam with Density 140-180 kg/m3 pasang Class Fire Performance test as per BS 476 Part 7, Air Erosion test for 10.000 fpm a velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 346 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.conforming to standard specification. 15 mm thick open cell nitrile rubber.
Supply & Installation of Thermal Insulation on Ducts not exposed to sunlight using Closec Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40- 60 kg/m3, Thermal Conductivity of 0.037 W/mk at 20 Celcius Mean Temp and μ≥7000 (without any additional vapour barrier) and with factory laminated aluminium foil of minimum 60 Microns thickness having weight of 193 gsm as per EN ISO 2286-2, tensile strength shall be 90N/15mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3; to be applied on Ducts using manufacturer's recommended Rubber based Adhesive in a blend of Solvents. 25 mm thick (Class O) Foil for Supply Air Duct
MOTOR CONTROL CENTRE ⅰ) For 2 x 8.5TR Outdoor Unit
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board of 31 MVA fau't capacity at 415 V complete with 4 strip, 63 A capacity Aluminium Bus Bar Electrolytic grade, cable alley, switchgears of following capacity & as per specifications. i) For Compressor 30 x 10 Sq. mm Aluminium Conductor
ii) For Indoor Unit blowar & compressor 30 x 4 Sq. mm Aluminium Conductor
iii) For Condenser Fan 20 x 1.5 Sq. mm Copper Condector
Control Cabling (PVC ) insulated & PVC sheathed armoured, Copper, Conductor of 1.1 KV grade of following sizes. 60 x 1.5 Sq. mm Copper Conductor
Supply & laying of 8 SWG GI wire
Add 18% G.S.T
Add 1% Labour Cess
Bidder Name
Amount
Gaurav Construction (GSTN-20DDDPP6795J1Z5) BID ID -598358
M/s PAWAN KUMAR BHAGAT (GSTN-20AAIFP9410F1ZL) BID ID -598359
Gaurav Construction
M/s PAWAN KUMAR BHAGAT
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .