Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹50,740Qualified Make: Accumax India
Model: Accuumax Model-59, And Also 68,61,62,60 105 FIRST FLOOR VISHAL TOWER DISTRICT CENTRE JANAKPURI JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0022043 07ASXPS7874B1ZX R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110058 | Make: Accumax India
Model: Accuumax Model-59, And Also 68,61,62,60 | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 Oct 2018, 11:00 amClosed
Water Quality Meters/Analyzers Water Quality Meters/Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE/NOMENCLATURE PROTECTION Type of Meter Analyzer Bench Type Bench Type Functional nomenclature Multi Parameter Water Quality Analyzer Multi Parameter Water Quality Analyzer Ingress Protection (Main Unit) IP 56 IP 55
IP 56
IP 57
IP 65
IP 66
IP 67
IP 68
NA being Bench Top Calibration Automatic Manual
Automatic MEASURED WATER QUALITY PARAMETERS Dissolved Oxygen (DO) true true
false DO % Stauration true true
false Conductivity true true
false Resistivity true true
false Salinity true true
false Total Dissolved Solids (TDS) true true
false pH true true
false Oxidation Reduction true true
false 1/8 Potential (ORP) Ammonium true true
false Nitrate true true
false Chloride true true
false Turbidity true true
false Depth true true
false Temperature true true
false Atmospheric Pressure true true
false MEASUREMENT OF DISSOLVED OXYGEN (DO)/DO % Saturation Dissolved Oxygen (DO) measurement Principle Electro Chemical ( Amperometric ) Optical
Electro Chemical ( Amperometric )
NA Sensor/Probe Electrode Type Polarographic for Electro Chemical Lifetime Luminiscent for Optical
Polarographic for Electro Chemical
Galvanic for Electro Chemical
NA Measurement Range for DO Content ( in ppm or mg/l ) 0-50 * Resolution ( in ppm or mg/l ) 0.02
0.05 * DO Accuracy ( +/- ) 2 * Measurement Range for DO % Saturation ( in % ) 0-500 0-200
0-400
0-500
0-600
0-800
NA Resolution ( in % ) 0.1
0.2 * DO % Accuracy (+/- ) 2 * MEASUREMENT OF CONDUCTIVITY (EC) Conductivity measurement principle Conductive (contacting) Conductive (contacting)
Inductive
NA Sensor Probe/Electrode Type 4 Cell Electrode 2 Cell Electrode
4 Cell Electrode
NA Material of Electrode Platinum Platinum
Titanium
Gold Plated Nickel
Graphite
NA Measurement Range ( in µS/cm ) 0-500 * Resolution ( in mho or µS/cm ) 0.002 * EC Accuracy ( +/- ) 1 * MEASUREMENT OF RESISTIVITY Resitivity measurement principle Conductivity Conversion Conductivity Conversion
NA 2/8 Lowest Measurement Value for Resistivity (in ohm-cm) 5 0
1
2
5
10
NA Highest Measurement Value for Resistivity (in Mega ohm-cm) 5 1
20
50
100
200
NA Resolution ( in ohm- cm) 1
2 * Resistivity Accuracy(+/- ) 2 * MEASUREMENT OF SALINITY Salinity measurement principle Conductivity Conversion Conductivity Conversion
NA Measurement Range ( in parts per thousand or g/l or PSU) 0-50 * Resolution (in g/l) 0.01
0.02 * Salinity Accuracy ( +/- ) 2 * MEASUREMENT OF TOTAL DISSOLVED SOLIDS (TDS) TDS measurement principle Conductivity Conversion Conductivity Conversion
NA TDS Measurement Range ( in parts per thousand or g/l ) 0-500 0-100
0-200
NA Resolution ( in g/l ) 0.001
0.005
0.05
0.1
0. 2 * TDS Accuracy ( +/- ) 2 * MEASUREMENT OF pH pH measurement principle Electro chemical Electro chemical
NA Sensor/Probe Electrode Type Hydrogen (Platinum) Electrode Hydrogen (Platinum) Electrode
Antimony Electrode
Glass Electrode
Ion Selective Electrode (ISE)
NA Number of Sensors Electrodes Single Electrode Single Electrode
Combination Electrode (2 Electrode)
Differential Electrode (3 Electrode)
NA pH Measurement Range 0-14 0-14
NA Resolution ( in pH number ) 0.01
0.02
0.2
0.5 * pH Accuracy ( +/- ) 1 * 3/8 MEASUREMENT OF OXIDATION REDUCTION POTENTIAL (ORP) ORP measurement principle Electro chemical Electro chemical
NA Sensor/Probe Electrode Type Platinum Electrode Platinum Electrode
NA Lowest Measurement Value for ORP (in mV ) -3000 -3000
2500
2000
1500
1000
500
0
NA Highest Measurement Value for ORP (in mV ) 3000 3000
NA Resolution ( in ± mV ) 0.05 * ORP Accuracy ( +/- ) 2 * MEASUREMENT OF AMMONIUM Sensor/Probe Electrode Type Ion Selective Electrode Ion Selective Electrode
NA Measurement Range ( in ppm or mg/l ) 0-300 0-100
0-300
NA Resolution ( in ppm or mg/l ) 0.005
0.01
0.2 * Ammonium Accuracy ( +/- ) 10 * MEASUREMENT OF NITRATE Sensor/Probe Electrode Type Ion Selective Electrode Ion Selective Electrode
NA Measurement Range ( in ppm or mg/l ) 0-500 0-100
0. 1 * Nitrate Accuracy ( +/- ) 10 * MEASUREMENT OF CHLORIDE Sensor/Probe/Electro de Type Ion Selective Electrode Ion Selective Electrode
NA Measurement Range ( in ppm or mg/l ) 0-400 0-400
0-1000
0-1200
0-1500
0.05 * Chloride Accuracy ( +/- ) 15 * MEASUREMENT OF TURBIDITY Turbidity measurement principle Nephelometric measurement according to ISO 7027 Nephelometric measurement according to ISO 7027
4/8 Nephelometric measurement according to US EPA 180.1
NA Light Source Infrared Led Infrared Led
White light tungsten lamp
NA Measurement of scattered light 30 degree scatter nephelometer 30 degree scatter nephelometer
90 degree scatter nephelometer
NA Lowest Measurement Value for Turbidity (in FNU or NTU ) 0.05 0.01
0.5
NA Highest Measurement Value for Turbidity (in FNU or NTU ) 50 * Resolution ( in FNU or FTU ) 0.01
1 * Turbidity Accuracy ( +/- ) 2 * MEASUREMENT OF TEMPERATURE Sensor/Probe Type Resistance Temperature (RTD) Detector Semi Conductor Based Thermister
Resistance Temperature (RTD) Detector
NA Lowest Measurement Value for Temperature (˚C) -20 -20
15
NA Highest Measurement Value for Temperature (˚C) 50 * Resolution (˚C) 0.005
0.5 * Temperature Accuracy ( +/- ) 1 * MEASUREMENT OF PRESSURE Sensor/Probe Type Pressure transducer Pressure transducer
NA Lowest Measurement Value for Pressure (in mmHg ) 200 * Highest Measurement Value for Pressure (in mmHg ) 1000 800
825
850
875
900
950
NA Resolution ( in mmHg ) 0.1
1 * Pressure Accuracy ( +/- ) 1 * 5/8 MEASUREMENT OF DEPTH Measurement Method Water Pressure method Water Pressure method
NA Depth Measurement Range (in meters) 0-50 * Length of Cable connecting peobe (inclusive in the scope of supply) 5 * COMPENSATION CORRECTION Temperature correction Automatic Automatic
Manual
Automatically compensates for manual input value
NA Salinity Correction Automatic Automatic
NA Barometric Pressure correction Automatic Automatic
NA DISPLAY/STORAGE Type of Display LCD * Display Digit Size 30 * Number of Digits in Display 5 * Number of parameters diplayed simultaneously 5 * Memory (in Data Sets) 20000 * Internal memory (GB) 64 * In-built GPS false * Date/time Stamp in Entries false * Connectivity interface USB
RS 232 * POWER SOURCE Power Source Rechargeable Battery * Battery Size
if Non Rechargeable Battery AA * Battery Chemistry
if Rechargeable Battery Li-ion * Voltage of each Battery 24 * Number of Batteries required for operation 1 * Number of Batteries Inclusive in the Scope 1 * 6/8 of Supply Battery Capacity (mAh) 10000 * Battery Life 1000 * Suitable Adapter to be supplied to make the equipment Work on 230 V ± 10 %
50 Hz true * GENERIC Armour housing of Sensor/Probe Rubberised metallic * Probe/Sensor Electrode supplied with equipment true * Number of elctrodes supplied 20 * Weight 2 * Dimensions ( mm x mm x mm ) - * Carry Case included in the scope of supply false * Any other features - * List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature -20 0
20 Maximum Operating Temperature 50 50
55
60
70 Operating Humidity
Rh at 40 deg C 65 65
70
75
80
85
90
95 WARRANTY Warranty on Equipment 1 1
3
4
6 Warranty on Probe Electrode 12 6
12
18
24
30
36
48 Warranty on Cables for Connecting Probe 1 1
5 CERTIFICATION Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the specification false true
false If Yes
Test Report to be furnished to the Buyer on demand NA * Test Report No and Date - * 7/8 Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Prasanna Ramesh 400703
BOARD OF RADIATION & ISOTOPE TECHNOLOGY
BARC
VASHI COMPLEX
SECTOR-20
VASHI
NEW MUMBAI 400703 2 15
711194
GEM/2018/B/100487
Water Quality Meters / Analyzers
15 days
Maharashtra; Thane
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Water Quality Meters/Analyzers Water Quality Meters/Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TYPE/NOMENCLATURE PROTECTION Type of Meter Analyzer Bench Type Bench Type Functional nomenclature Multi Parameter Water Quality Analyzer Multi Parameter Water Quality Analyzer Ingress Protection (Main Unit) IP 56 IP 55 | - | - | - |
| IP 56 | - | - | - |
| IP 57 | - | - | - |
| IP 65 | - | - | - |
| IP 66 | - | - | - |
| IP 67 | - | - | - |
| IP 68 | - | - | - |
| NA being Bench Top Calibration Automatic Manual | - | - | - |
| Automatic MEASURED WATER QUALITY PARAMETERS Dissolved Oxygen (DO) true true | - | - | - |
| false DO % Stauration true true | - | - | - |
| false Conductivity true true | - | - | - |
| false Resistivity true true | - | - | - |
| false Salinity true true | - | - | - |
| false Total Dissolved Solids (TDS) true true | - | - | - |
| false pH true true | - | - | - |
| false Oxidation Reduction true true | - | - | - |
| false 1/8 Potential (ORP) Ammonium true true | - | - | - |
| false Nitrate true true | - | - | - |
| false Chloride true true | - | - | - |
| false Turbidity true true | - | - | - |
| false Depth true true | - | - | - |
| false Temperature true true | - | - | - |
| false Atmospheric Pressure true true | - | - | - |
| false MEASUREMENT OF DISSOLVED OXYGEN (DO)/DO % Saturation Dissolved Oxygen (DO) measurement Principle Electro Chemical ( Amperometric ) Optical | - | - | - |
| Electro Chemical ( Amperometric ) | - | - | - |
| NA Sensor/Probe Electrode Type Polarographic for Electro Chemical Lifetime Luminiscent for Optical | - | - | - |
| Polarographic for Electro Chemical | - | - | - |
| Galvanic for Electro Chemical | - | - | - |
| NA Measurement Range for DO Content ( in ppm or mg/l ) 0-50 * Resolution ( in ppm or mg/l ) 0.02 | - | - | - |
| 0.05 * DO Accuracy ( +/- ) 2 * Measurement Range for DO % Saturation ( in % ) 0-500 0-200 | - | - | - |
| 0-400 | - | - | - |
| 0-500 | - | - | - |
| 0-600 | - | - | - |
| 0-800 | - | - | - |
| NA Resolution ( in % ) 0.1 | - | - | - |
| 0.2 * DO % Accuracy (+/- ) 2 * MEASUREMENT OF CONDUCTIVITY (EC) Conductivity measurement principle Conductive (contacting) Conductive (contacting) | - | - | - |
| Inductive | - | - | - |
| NA Sensor Probe/Electrode Type 4 Cell Electrode 2 Cell Electrode | - | - | - |
| 4 Cell Electrode | - | - | - |
| NA Material of Electrode Platinum Platinum | - | - | - |
| Titanium | - | - | - |
| Gold Plated Nickel | - | - | - |
| Graphite | - | - | - |
| NA Measurement Range ( in µS/cm ) 0-500 * Resolution ( in mho or µS/cm ) 0.002 * EC Accuracy ( +/- ) 1 * MEASUREMENT OF RESISTIVITY Resitivity measurement principle Conductivity Conversion Conductivity Conversion | - | - | - |
| NA 2/8 Lowest Measurement Value for Resistivity (in ohm-cm) 5 0 | - | - | - |
| 1 | - | - | - |
| 2 | - | - | - |
| 5 | - | - | - |
| 10 | - | - | - |
| NA Highest Measurement Value for Resistivity (in Mega ohm-cm) 5 1 | - | - | - |
| 20 | - | - | - |
| 50 | - | - | - |
| 100 | - | - | - |
| 200 | - | - | - |
| NA Resolution ( in ohm- cm) 1 | - | - | - |
| 2 * Resistivity Accuracy(+/- ) 2 * MEASUREMENT OF SALINITY Salinity measurement principle Conductivity Conversion Conductivity Conversion | - | - | - |
| NA Measurement Range ( in parts per thousand or g/l or PSU) 0-50 * Resolution (in g/l) 0.01 | - | - | - |
| 0.02 * Salinity Accuracy ( +/- ) 2 * MEASUREMENT OF TOTAL DISSOLVED SOLIDS (TDS) TDS measurement principle Conductivity Conversion Conductivity Conversion | - | - | - |
| NA TDS Measurement Range ( in parts per thousand or g/l ) 0-500 0-100 | - | - | - |
| 0-200 | - | - | - |
| NA Resolution ( in g/l ) 0.001 | - | - | - |
| 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0. 2 * TDS Accuracy ( +/- ) 2 * MEASUREMENT OF pH pH measurement principle Electro chemical Electro chemical | - | - | - |
| NA Sensor/Probe Electrode Type Hydrogen (Platinum) Electrode Hydrogen (Platinum) Electrode | - | - | - |
| Antimony Electrode | - | - | - |
| Glass Electrode | - | - | - |
| Ion Selective Electrode (ISE) | - | - | - |
| NA Number of Sensors Electrodes Single Electrode Single Electrode | - | - | - |
| Combination Electrode (2 Electrode) | - | - | - |
| Differential Electrode (3 Electrode) | - | - | - |
| NA pH Measurement Range 0-14 0-14 | - | - | - |
| NA Resolution ( in pH number ) 0.01 | - | - | - |
| 0.02 | - | - | - |
| 0.2 | - | - | - |
| 0.5 * pH Accuracy ( +/- ) 1 * 3/8 MEASUREMENT OF OXIDATION REDUCTION POTENTIAL (ORP) ORP measurement principle Electro chemical Electro chemical | - | - | - |
| NA Sensor/Probe Electrode Type Platinum Electrode Platinum Electrode | - | - | - |
| NA Lowest Measurement Value for ORP (in mV ) -3000 -3000 | - | - | - |
| 2500 | - | - | - |
| 2000 | - | - | - |
| 1500 | - | - | - |
| 1000 | - | - | - |
| 500 | - | - | - |
| 0 | - | - | - |
| NA Highest Measurement Value for ORP (in mV ) 3000 3000 | - | - | - |
| NA Resolution ( in ± mV ) 0.05 * ORP Accuracy ( +/- ) 2 * MEASUREMENT OF AMMONIUM Sensor/Probe Electrode Type Ion Selective Electrode Ion Selective Electrode | - | - | - |
| NA Measurement Range ( in ppm or mg/l ) 0-300 0-100 | - | - | - |
| 0-300 | - | - | - |
| NA Resolution ( in ppm or mg/l ) 0.005 | - | - | - |
| 0.01 | - | - | - |
| 0.2 * Ammonium Accuracy ( +/- ) 10 * MEASUREMENT OF NITRATE Sensor/Probe Electrode Type Ion Selective Electrode Ion Selective Electrode | - | - | - |
| NA Measurement Range ( in ppm or mg/l ) 0-500 0-100 | - | - | - |
| 0. 1 * Nitrate Accuracy ( +/- ) 10 * MEASUREMENT OF CHLORIDE Sensor/Probe/Electro de Type Ion Selective Electrode Ion Selective Electrode | - | - | - |
| NA Measurement Range ( in ppm or mg/l ) 0-400 0-400 | - | - | - |
| 0-1000 | - | - | - |
| 0-1200 | - | - | - |
| 0-1500 | - | - | - |
| 0.05 * Chloride Accuracy ( +/- ) 15 * MEASUREMENT OF TURBIDITY Turbidity measurement principle Nephelometric measurement according to ISO 7027 Nephelometric measurement according to ISO 7027 | - | - | - |
| 4/8 Nephelometric measurement according to US EPA 180.1 | - | - | - |
| NA Light Source Infrared Led Infrared Led | - | - | - |
| White light tungsten lamp | - | - | - |
| NA Measurement of scattered light 30 degree scatter nephelometer 30 degree scatter nephelometer | - | - | - |
| 90 degree scatter nephelometer | - | - | - |
| NA Lowest Measurement Value for Turbidity (in FNU or NTU ) 0.05 0.01 | - | - | - |
| 0.5 | - | - | - |
| NA Highest Measurement Value for Turbidity (in FNU or NTU ) 50 * Resolution ( in FNU or FTU ) 0.01 | - | - | - |
| 1 * Turbidity Accuracy ( +/- ) 2 * MEASUREMENT OF TEMPERATURE Sensor/Probe Type Resistance Temperature (RTD) Detector Semi Conductor Based Thermister | - | - | - |
| Resistance Temperature (RTD) Detector | - | - | - |
| NA Lowest Measurement Value for Temperature (˚C) -20 -20 | - | - | - |
| 15 | - | - | - |
| NA Highest Measurement Value for Temperature (˚C) 50 * Resolution (˚C) 0.005 | - | - | - |
| 0.5 * Temperature Accuracy ( +/- ) 1 * MEASUREMENT OF PRESSURE Sensor/Probe Type Pressure transducer Pressure transducer | - | - | - |
| NA Lowest Measurement Value for Pressure (in mmHg ) 200 * Highest Measurement Value for Pressure (in mmHg ) 1000 800 | - | - | - |
| 825 | - | - | - |
| 850 | - | - | - |
| 875 | - | - | - |
| 900 | - | - | - |
| 950 | - | - | - |
| NA Resolution ( in mmHg ) 0.1 | - | - | - |
| 1 * Pressure Accuracy ( +/- ) 1 * 5/8 MEASUREMENT OF DEPTH Measurement Method Water Pressure method Water Pressure method | - | - | - |
| NA Depth Measurement Range (in meters) 0-50 * Length of Cable connecting peobe (inclusive in the scope of supply) 5 * COMPENSATION CORRECTION Temperature correction Automatic Automatic | - | - | - |
| Manual | - | - | - |
| Automatically compensates for manual input value | - | - | - |
| NA Salinity Correction Automatic Automatic | - | - | - |
| NA Barometric Pressure correction Automatic Automatic | - | - | - |
| NA DISPLAY/STORAGE Type of Display LCD * Display Digit Size 30 * Number of Digits in Display 5 * Number of parameters diplayed simultaneously 5 * Memory (in Data Sets) 20000 * Internal memory (GB) 64 * In-built GPS false * Date/time Stamp in Entries false * Connectivity interface USB | - | - | - |
| RS 232 * POWER SOURCE Power Source Rechargeable Battery * Battery Size | - | - | - |
| if Non Rechargeable Battery AA * Battery Chemistry | - | - | - |
| if Rechargeable Battery Li-ion * Voltage of each Battery 24 * Number of Batteries required for operation 1 * Number of Batteries Inclusive in the Scope 1 * 6/8 of Supply Battery Capacity (mAh) 10000 * Battery Life 1000 * Suitable Adapter to be supplied to make the equipment Work on 230 V ± 10 % | - | - | - |
| 50 Hz true * GENERIC Armour housing of Sensor/Probe Rubberised metallic * Probe/Sensor Electrode supplied with equipment true * Number of elctrodes supplied 20 * Weight 2 * Dimensions ( mm x mm x mm ) - * Carry Case included in the scope of supply false * Any other features - * List of Items and Quantity of each item included in the offer - * OPERATING CONDITIONS Minimum Operating Temperature -20 0 | - | - | - |
| 20 Maximum Operating Temperature 50 50 | - | - | - |
| 55 | - | - | - |
| 60 | - | - | - |
| 70 Operating Humidity | - | - | - |
| Rh at 40 deg C 65 65 | - | - | - |
| 70 | - | - | - |
| 75 | - | - | - |
| 80 | - | - | - |
| 85 | - | - | - |
| 90 | - | - | - |
| 95 WARRANTY Warranty on Equipment 1 1 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 6 Warranty on Probe Electrode 12 6 | - | - | - |
| 12 | - | - | - |
| 18 | - | - | - |
| 24 | - | - | - |
| 30 | - | - | - |
| 36 | - | - | - |
| 48 Warranty on Cables for Connecting Probe 1 1 | - | - | - |
| 5 CERTIFICATION Availability of Test Reports from Central Govt/NABL approved/ILAC accredited Lab to prove conformity to the specification false true | - | - | - |
| false If Yes | - | - | - |
| Test Report to be furnished to the Buyer on demand NA * Test Report No and Date - * 7/8 Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Prasanna Ramesh 400703 | - | - | - |
| BOARD OF RADIATION & ISOTOPE TECHNOLOGY | - | - | - |
| BARC | - | - | - |
| VASHI COMPLEX | - | - | - |
| SECTOR-20 | - | - | - |
| VASHI | - | - | - |
| NEW MUMBAI 400703 2 15 | - | - | - |
Exempted
22 Oct 2018
8 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_711194.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .