Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹18.0 L+₹2.3 L (14.8%)Rejected-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Rejected-AOC Higher rate | |
| 3 | L3₹19.3 L+₹3.6 L (22.9%)Rejected-AOC | L3 | Rejected-AOC Higher rate | |
| 4 | L4₹19.3 L+₹3.6 L (23.0%)Rejected-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L4 | Rejected-AOC Higher rate | |
| 5 | L5₹19.3 L+₹3.6 L (23.1%)Rejected-AOC | L5 | Rejected-AOC Higher rate |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
4 Sept 2021, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
CA NO GEND46 2021 22 REPAIR MAINTENANCE OF CERTAIN EM FITTINGS FIXTURES AND INTERNAL WIRINGS AS WELL AS SUBMAIN WIRING, LT PANEL AT CERTAIN BUILDINGS OF ABH MESS UNDER GE NEW DELHI
2021_MES_466517_1
GE/ND-46/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
CA NO GEND46 2021 22 REPAIR MAINTENANCE OF CERTAIN EM FITTINGS FIXTURES AND INTERNAL WIRINGS AS WELL AS SUBMAIN WIRING, LT PANEL AT CERTAIN BUILDINGS OF ABH MESS UNDER GE NEW DELHI
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹48,000
Yes
9 Nov 2021
9 Aug 2021
11 Sept 2021
9 Aug 2021
4 Sept 2021
23 Aug 2021
Amount
Taking down copper/aluminium point wiring (fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,Light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring with PVC FRLS insulated unsheathed multi-stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in existing conduits and its accessories, including replacement of factory made steel boxes suitable for modular switch/sockets including modular plates of suitable size as per site requirement for the following Note: Cutting & chasing, if required, shall be measured/paid under relevant items
One light/ceiling fan/exhaust fan point controlled by one no., one way switch 5/6 amps.
One light point controlled by one nos, two way switch, 5/6 amp
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one no. one way switch, 5/6 amp on independent board.
One 3 pin 5 Amps socket outlet point controlled by one no. one way switch, 5/6 amp on same board.
All as per item No 2.00 here-in-before but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 amp socket outlet point on independent board complete all as specified and as directed.
All as per item No 2 here-in-before but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core cable on independent circuit complete all as specified and as directed.
M&L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC conduit of suitable sizes of medium grade ISI marked for surface wiring and its accessories, including MS sunken box and hylem sheet of suitable size, ISI marked for housing the switches and sockets, for the following
One light/ceiling fan/exhaust fan point controlled by one no., one way switch 5/6 amps.
One light point controlled by two nos, two way switch, 5/6 amp
One three pin 5 Amp socket outlet point controlled by one no, one way switch, 5/6 amp on independent board
One bell / buzzer point controlled by one bell push
One three pin 5 Amp socket outlet point controlled by one no, one way switch, 5/6 amp on same board
All as per item No. 5.00 here in before but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket outlet point on independent board complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good the disturbed surface, cutting not exc. 10 cm girth on brick walls complete all as specified and as directed.
Taking down of submain wiring including taking out conduit pipe of any description and of any size complete all as specified and as directed.
S&F submain wiring alongwith earth wire with 2 run of 6 Sqmm (Main Cable and neutral) and one run of 6 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm bore with all fittings and accessories complete all as specified and as directed.
S&F submain wiring alongwith earth wire with 2 run of 10 Sqmm (Main Cable and neutral) and one run of 10 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm bore with all fittings and accessories complete all as specified and as directed.
S&F Modular switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame complete all as specified and as directed.
S&F Modular switch 6 amps 250 V AC two way with ISI mark including 6 amps switch frame complete all as specified and as directed.
S&F modular switch 16 A SP one way 240 volts complete all as specified and as directed.
S&F modular socket 6 A Multi socket for 2/ 3 pin, 240 volts complete all as specified and as directed.
S&F modular socket outlet 16 A-2/3 pin combined 240 volts complete all as specified and as directed.
S&F bell push, flush type 5 A 240 volts complete all as specified and as directed.
S&F modular bell push 6A with Neon 1 module 240 volts complete all as specified and as directed.
S&F electronic fan regulator modular type 100Watt step type Double Modular as per existing complete all as specified and as directed.
S&F switch piano flush button single pole one way 6 amps complete all as specified and as directed.
S&F switch piano flush type 15 amps single pole one way complete all as specified and as directed.
S&F socket outlet 5/6 amps 2 in 1, 3 pin flush type complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15 amp, flush type complete all as specified and as directed.
S&F STEP type electronic fan regulator flush type 230 volts complete all as specified and as directed.
S&F in repair electric bell Ding-Dong AC 230 Volt complete all as specified and as directed.
S&F ceiling rose, 3 phase/ PVC/ polycarbonate isolated body complete all as specified and as directed.
Taking down DB of SPN 4/8/12 way type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 12 way with 200 amps rated bus bar complete all as specified and as directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 8 way with 200 amps rated bus bar complete all as specified and as directed.
S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 4 way with 200 amps rated bus bar complete all as specified and as directed.
Taking down MCB 6-32/40-63 Amps SP/SPN and 40-63 Amps TPN type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F MCB TPN 40 to 63 Amps, 415 V, 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F of MCB SPN 40 to 63 Amp 240 volt 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F of MCB SPN 6 to 32 Amp 240 volt 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F MCB SP 40 Amp to 63 Amp, 240 V, 10 kA rupture capacity, series 'C' complete all as specified and as directed.
S&F MCB SP 6 Amp to 32 Amp 240 volts 10 kA rupture capacity, series 'C' complete all as specified and as directed.
Taking down Metal clad enclosure with plug and socket 10/20 Amps, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F sheet Metal enclosure with plug and socket, 10 Amp, 240 volts with one MCB single pole, complete all as specified and as directed.
S&F sheet Metal enclosure with plug and socket 20 Amp 240 volts with one MCB single pole complete all as specified and as directed.
S&F in replacement LED batten of 20 Watt 230Volt (size 4 ft), box type complete with LED Tube Light 20 Watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement of Endura Linear LED batten of 10 W (2 ft.), extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver in AC complete all as specified and as directed.
S&F in replacement aesthetically designed circular shaped Recess & surface /PENDANT MOUNTING designer LED light of 18 W fixture with PMMA diffuser to give glare free light, high performance low-height back lit downlighter, Robust PDC aluminum housing, Efficacy 100LM/W complete all as specified and as directed.
Supply & fix in replacement aesthetically designed Wall mounted decorative wall LED light of 6 W fixture with opal diffuser to give glare free light including suitable LED lamp of 6 W having Lamp base E27 complete all as specified and as directed.
Supply & fix in in replacement aesthetically designed Wall mounted decorative mirror LED light of 3.6 W fixture with opal diffuser to give glare free light including suitable LED lamp of 3.6 W having Lamp base E27 complete all as specified and as directed.
Supply & fix in replacement aesthetically designed recessed/surface mounted decorative downlighter LED light of 12 W fixture with opal diffuser to give glare free light including suitable LED lamp of 12 W complete all as specified and as directed.
Supply & fix in replacement aesthetically designed recessed/surface mounted decorative downlighter LED light of 15 W fixture with opal diffuser to give glare free light including suitable LED lamp of 15 W complete all as specified and as directed.
Supply & fix in replacement 3 watt aesthetically designed recessed/surface mounted decorative downlighter/ LED Spot Light, with CRI >80, Beam angle 36 degree, Vertical Tilt 30 degree, complete all as specified and as directed.
Supply & fix in replacement 6 watt aesthetically designed recessed/surface mounted decorative downlighter LED Spot Light, with CRI >80, Beam angle 36 degree , Vertical Tilt 30 degree complete all as specified and as directed.
Supply & fix in in replacement 2x2 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified and as directed.
Supply & fix in replacement 9 watt aesthetically designed recessed/surface mounted decorative downlighter LED Spot Light, with CRI >80, Beam angle 36 degree , Vertical Tilt 30 degree complete all as specified and as directed.
Supply & fix in replacement 1x4 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified and as directed.
Supply & fix in replacement 12 watt, aesthetically designed recessed/surface mounted decorative downlighter LED Spot Light, with CRI >80, Beam angle 36 degree, Vertical Tilt 30 degree complete all as specified and as directed.
S&F in replacement factory made load line DBs double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and as directed.
S&F in replacement factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and as directed.
Supply and fix in replacement Metal clad plug top of capacity 20 Amp, 240 volts complete all as specified and as directed.
Supply and fix in replacement Metal clad socket of capacity 20 Amp, 240 volts complete all as specified and as directed.
Supply and fix only decorative laminated sheet 3mm thick of size 8'' X 12'' including necessary cutting of sheet for fixing switch / socket complete all as specified and as directed.
Supply and fix only decorative laminated sheet 3mm thick of size 8'' X 5'' including necessary cutting of sheet for fixing switch / socket complete all as specified and as directed.
Supply and fix only decorative laminated sheet 3mm thick of size 7'' X 4'' including necessary cutting of sheet for fixing switch / socket complete all as specified and as directed.
Supply and fix only decorative laminated T cover sheet 3mm thick of size 2/3 inch dia complete all as specified and as directed.
Supply and fix only fan capacitor of the following capacity :-
Supply and fix only non metallic rigid PVC conduit medium grade 20 mm dia, ISI Mark complete all as specified and as directed.
Supply and fix only non metallic rigid PVC casing caping, ISI Mark complete all as specified and as directed.
Taking down of ceiling fan/ exhaust fan, dismantling of blades, transportation to workshop for carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and as directed.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush, ball bearing wherever required complete all as specified and as directed.
All as per ser item No 64.00 here-in-before but exhaust fan 230/300 mm sweep
All as per ser item No 64.00 here-in-before but exhaust fan 400 mm sweep
S&F in repair ceiling fan Ball bearing of suitable size & model (as per sample) complete all as specified and as directed.
M&L for replacing 'U' clamps with rubber reel, bolts, nuts, washers and safety pin for ceiling fan of any size/ make complete all as specified and as directed.
M&L in repair for Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of synthetic enamel white paint complete all as specified and as directed.
S&F in repair Canopy of Ceiling fans of 1200/1400mm swipe size heavy duty duly painted with one coat of synthetic enamel white paint complete all as specified and as directed.
M&L for spray painting (white colour) with synthetic enamel paint to Ceiling fans/Exhaust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black synthetic enamel paint complete all as specified and as directed.
Supply & fixing in replacement flat ceiling fan blade of aluminium, 1mm thickness suitable for 1200mm sweep ceiling fan,12-15 degree tilted, having 3 Nos in each set complete all as specified and as directed.
Supply & fixing in replacement flat exhaust fan blade of aluminium, 1mm thickness suitable for 230/300/400 mm sweep exhaust fan, 12-15 degree tilted, having 3 nos. in each set complete all as specified and as directed.
S&F in repair Frame of 230/300 /400 mm Aluminium metallic exhaust fan including taking down of old frame complete all as specified and as directed.
Supply & fixing in repair flat ventilation fan blade of PVC, 1mm thickness suitable for 230/250/300mm sweep exhaust fan,12-15 degree tilted, having 4 nos. in each set complete all as specified and as directed.
S&F in repair ventilation fan motor of size 230/250/300 mm including taking down of old ventilation fan motor complete all as specified and directed.
S&F in replacement of PVC Frame of 230/250/300 mm ventilation fan including taking down of old frame complete all as specified and as directed.
Taking down carefully Geysers 25/50 Ltr capacity, opening for inspection, cleaning, descaling, reassembling and refixing in position after carrying out repairs like soldering/ brazing etc including replacement of pressed rubber gasket, Nuts, bolts, neon indicator lamp 1 Amp etc. complete all as specified and as directed.
M&L for spray painting (white colour) with synthetic enamel paint to Geysers 25/50 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and as directed.
M&L in repair for heating element of 2.0 kW (Circular) as required at site including rubber washers (ISI marked) etc complete all as specified and as directed.
M&L in repair for heating element of 2.0 kW (triangular) as required at site including rubber washers (ISI marked) etc complete all as specified and as directed.
S&F in repair storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 50 litre capacity geysers with collar complete duly tested at required pressure complete all as specified and as directed.
S&F in repair storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure complete all as specified and as directed.
M&L for replacement of insulating material (Glass wool) for 25/ 50 litre capacity Geysers complete all as specified and as directed.
S&F in repairs base plate assembly 20 SWG heavy duty suitable for 50 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and as directed.
S&F in repairs base plate assembly 20 SWG heavy duty suitable for 25 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and as directed.
M&L in repair for chromium plated copper connection pipe 600/1000 mm long with two brass adopters washers and connecting up complete all as specified and directed.
M&L in repair for safety nut for high pressure release (As per sample) complete all as specified and as directed.
M&L in repair for top cover for geysers of 25/50 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) complete all as specified and as directed.
S&F in repair for bottom cover for geysers of 25/50 ltr any make required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces complete all as specified and as directed.
S&F in repair outer cover for geyser made out of MS sheet suitable for 50 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
S&F in repair outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
S&F in repair thermostat (ISI Marked) for 25/50 Liters capacity Geyser complete all as specified and as directed.
S&F in repair indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample) complete all as specified and as directed.
Supply and fix in repair mild steel hole fastener 10mm dia, 100mm long including nut and washer complete all as specified and as directed.
Taking down MCCBs any type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls/panel etc. complete all as specified and as directed.
Supply and fixing MCCB, 4 pole, 415 volt of capacity 125A breaking capacity not less than 25KA, Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and as directed.
Supply and fixing MCCB, 4 pole, 415 volt of capacity 250 Amp, breaking capacity not less than 36 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, replacement of thimbles, minor parts like nuts bolts washer etc. complete all as specified and as directed.
M&L in repair for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B-0 using 12 mm graded crushed stone aggregate, RCC cover etc. complete all as specified and as directed.
M&L in replacement for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32X6 mm galvanised iron strip complete all as specified and as directed.
Disconnecting, dismantling the existing LT panel Meter board of size 1500mmX1800mmX350mm, 415 Volt, 3 phase, 4 wire with bus bar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re-fixing back including connecting up all connections on and including new PCC foundation, connecting up all dismantled connection and ensure proper electric supply distribution to Users DB after carrying out the following repair works in panel and including provision of necessary PCC work of grade 1:2:4 in meter room to make sure all panels fitted properly complete all as specified and as directed.
Item no. 101 contdd.. 1. Complete painting with two coats of synthetic enamel paint of approved colour with writing/marking of connection details including Qtr no., danger sign board, working voltage etc 2. Provisioning of additional Din rail for 01 no. MCB SPN including MCB SPN 63 amps 10 kA, 230 V 'C' curve 3. Cutting the rusted out portion of the LT panel board and Welding with new sheets of thickness 2 mm including necessary fabrication at site and necessary painting etc. 4. Replacement of view glass for meter compartment. 5. Reconnecting the submains to the MCBs and MCCBs terminal with the help of copper lugs and thimbles and tightening properly in such a way that no leakage current found during site inspection.
Disconnecting, dismantling the existing LT panel Meter board for LIFT of size 600mmX1400mmX300mm with angle frame 50mmX50mmX6mm, 415 Volt, 3 phase, 4 wire with busbar 400 amp capacity from existing foundation after taking proper shut down and restoration of electric supply to quarters by necessary arrangements as directed and keeping safe custody for re-fixing back including connecting up all connections on and including new foundation, connecting up all dismantled connection and ensure proper electric supply distribution to Users DB after carrying out the following repair works in panel and including necessary PCC work of grade 1:2:4 in meter room to make sure all panels fitted properly complete all as specified and as directed.
Item no. 102 contdd.. 1. Complete painting with two coats of synthetic enamel paint of approved colour with writing/marking of connection details including Qtr no., danger sign board, working voltage etc 2. Cutting the rusted out portion of the LT panel board and Welding with new sheets of thickness 2 mm including necessary fabrication at site and necessary painting etc. 3. Replacement of view glass for meter compartment.
M&L for complete servicing of gate sensor including rewiring, cleaning, repair of electronic motor, sensor and replacement of all other required accessories for smooth functioning complete all as specified and as directed. Note: Cost of replacement of spare parts is deemed to be included in quoted rate.
S&F in replacement gang box two module suitable for fitit'ng one 5Aswitch /socket complete all as specified and as directed.
S&F in replacement gang box four module suitable for fitting one 5A switch and one socket complete all as specified and as directed.
S&F in replacement gang box four module suitable for fitting one 15A switch and one socket complete all as specified and as directed.
M/S Sunil Steel Works
M/S VEDHANT ASSOCIATES
NEERU ELECTRICALS
Grid Infratech Pvt Ltd
GLIBS CONSTRUCTION
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .