Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.3 LAccepted-Finance 111 MINI SHOPPING COMPLEX NEAR HOTEL ASIA NEHRU MARKET JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | 1 | Accepted-Finance Found eligible | |
| 2 | 2₹6.7 L+₹45,360 (7.23%)Accepted-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | 2 | Accepted-Finance Found eligible | |
| 3 | 3₹6.8 L+₹54,250 (8.64%)Accepted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | 3 | Accepted-Finance Found eligible | |
| 4 | 4₹6.8 L+₹54,750 (8.72%)Accepted-Finance BHAGWATI NAGAR JAMMU | 4 | Accepted-Finance Found eligible |
Tender Value
₹6.8 L
EMD Value
₹13,673
Closing Date
27 Jun 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MID Akhnoor/Nowshera
Office of Executive Engineer MID Akhnoor/Nowshera
Providing/fitting, installation, testing and commissioning of automatic star delta starters for pumping unit no.01 and 02 along with other allied works at LIS Aryanpura
2024_IFC_249123_1
MID/AN/21
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
60 days
Aryanpura
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer MID Akhnoor/Nowshera
₹13,673
Yes
Office of Executive Engineer MID Akhnoor/Nowshera
23 Jul 2024
4 Jun 2024
28 Jun 2024
4 Jun 2024
27 Jun 2024
8 Jun 2024
5 Jun 2024
Providing/fitting, installation, testing and commissioning of protection panel cum FASD starters for pumping unit no. 01& 02 along with other allied works at LIS Aryanpura. Description of panel Designing, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. for pumping unit no. 01& 02 at L.I.S Aryanpura. The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables along with terminal plates input and output and crimping of thimbles properly according to size and specification. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: M.C.C.B. The panel should be fitted with an M.C.C.B. of 400 Ampere capacity, 1 no. volt meter, 1 no ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S. switch and a set of RYB indicators at incoming side including the bus bars. Outgoing no. 1: The panel should be fitted with a 100 HP fully automatic star delta starter comprises of 3 Nos. air break contactors compatible with 100HP induction motor (2 nos. 140 A for main and delta supply, 1 No. air break contactor 140 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of outgoing supply for pumping unit no. 1 Outgoing no. 2: The panel should be fitted with a 100 HP fully automatic star delta starter comprises of 3 Nos. air break contactors compatible with 100HP induction motor (2 nos. 140 A for main and delta supply, 1 No. air break contactor 140 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of outgoing supply for pumping unit no. 2 Protections device / fault analyzer : A protections devise / fault analyzer shall be fitted with the panel with capability to protect each motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings : A. Voltage related fault: Single phasing, under voltage, over voltage, unbalance voltage. B. Current related fault: Over current / load, dry running, unbalance current / load, earth leakage, short circuiting. C. Display line current of RYB Phase and also line voltage of RY ,YB and BR phase. Bimetal overload relay: Bimetal over load relay of suitable range should be fitted with in the each starter as an extra protection to protect the motors in case of failure of fault analyzer . Providing/ fitting of suitable capacity 35 sq mm or any other suitable capacity copper cable (60 mtrs. Approx.) for 100HP motor. Complete job includes cost of providing/ fitting, transportation charges, hire charges of tool and tackles charges, hire charges of skilled and unskilled labour, and all kinds of taxes thereof. complete job Make of MCCB – Any reputed make like L&T,Havells etc. or any other as per ISO standards Make of contactor – Any reputed make like Havells or any other as per ISO standards Make of cable – Any reputed make like Polycab, Havells etc. or any other as per ISO standards Supply/ installation/ testing and commissioning of 400 ampere main switch at LIS Aryanpura. Job involves shifting of new 400 Ampere main switch of reputed make to the site of LIS. The main switch should be of reputed make like L&T,Havells etc. or any other as per ISO standards Job includes fitting of 400 Ampere main switch and providing the electrical connections by new thimbles duly crimped and taped. . Complete job includes cost of material, labour charges, manual handling, transportation charges and hiring charges of tools and tackles. Providing/fitting of 250 mm diameter cast iron Sluice Valve PN10 rating of pumping unit in 1 No. after replacing the existing damaged Sluice valve by way of cutting rusted nuts, bolts with gas cutter. The valve should be of reputed manufacture like Kirloskar, KSB etc. The job involves shifting of 250mm dia sluice valve to site of LIS by using mechanical transport and manual labour .The job further involves fitting of flanged ends cast iron Sluice Valve on the delivery side of pumping unit with rubber gaskets , nuts and bolts on the delivery pipeline by using skilled labour and suitable tools & tackles..The job includes the cost of material, carriage and hire charges of material and tools and tackles required for the job, labour charges for skilled and semi skilled labour at site L.I.S.
SUNIL KUMAR SURI CONTRACTOR
Rishabh Electricals and Mechanical Works
PERFECT ELECTRICAL WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .