| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹15.5 L+₹1.1 L (7.45%)Rejected-Finance FIRST FLOOR CREATIVE TOWER EROOR POST VYTTILA ERNAKULAM PIN 682 306 | ERNAKULAM | ERNAKULAM | KERALA | 682306 | L2 | Rejected-Finance L2 | |
| 3 | L3₹18.5 L+₹4.1 L (28.1%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹19.2 L
EMD Value
₹38,400
Closing Date
14 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAVY LAKSHADWEEP
OFFICE OF GE NAVY LAKSHADWEEP COAST GUARD ROAD KAVARATTI
PROVISION OF CERTAIN SANCTIONED REVENUE AND MINOR WORK AT KAVARATTI AND ANDROTH UNDER GE NAVY LAKSHADEEP
2020_MES_388380_1
8263E8
Open Tender
Civil Works
Item Rate
180 days
KAVARATTI ANDROTH
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE NAVY LAKSHADWEEP
₹38,400
29 Dec 2020
20 Oct 2020
16 Nov 2020
20 Oct 2020
14 Nov 2020
2 Nov 2020
20 Oct 2020 - 27 Oct 2020
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Hard/Dense soil complete all as specified and as directed by Engineer in charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 depth and getting out soft/loose soil for laying cables/pipes/erection of poles etc complete all as specified and as directed by Engineer in charge.
Returning filling in, with excavated soils incl. spreading, levelling, watering and well ramming in layers n.exc. 25 Cms complete all as specified and as directed by Engineer in charge.
Removing excavated material/ surplus soil exceeding 250 M and n.exc. 500M and depositing where directed at a level n.exc. 1.50M above the starting point complete all as specified and as directed by Engineer in Charge.
Material and labour for 75mm thick plain cement concrete 1:4:8 type D-2(using 40 mm graded stone aggregate ) as in sub base complete all as specified and as directed by Engineer in charge.
Material and labour for 20 mm thick cement screed bed or bedding layer in CM 1:4 as in base for laying tiles complete all as specified and as directed by Engineer in charge.
Material and labour for Plain cement concrete 1:3:6 Type C-2 (using 40 mm graded stone aggregate ) as in foundation, including necessary formwork complete all as specified and as directed by Engineer in charge.
Material and labour for chequered cement concrete tiles 30cm x 30cm and 25mm thick set, jointed, pointed with neat cement slurry with white/coloured cement and pigment in path to match the foot path complete all as specified and as directed by Engineer in charge.
Removing excavated soil to a distance n.exc 50m and deposited where as directed by the Engineer-in-Charge
Material and Labour for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core in and including stove enamelled steel conduit pipe of dia not less than 19 mm including 1.50 sqmm green copper conductor as continuous earth wire with all accessories complete all as specified and directed for the One light/fan point controlled by one switch complete all as specified and as directed by Engineer in charge.
Material and labour for Submain wiring with Two runs of single core 2.5 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including stove enamelled steel conduit pipe and one run of PVC insulated cable of size 2.5 sqmm size multi stranded copper conductor PVC insulated and unsheathed for contineous earth wire with junction boxes and other accessories for satisfactory completion of job complete all as specified and as directed by Engineer in charge. Note : Two runs of of 2.5 sqmm PVC insulated stranded copper conductor and One run of earth wire 2.5 sqmm shall be measured and paid as one unit. Make of cable:- Polycab / Finolex / Havells.
Material and Labour for sub main wiring/power wiring with Four runs of 4.0 sqmm PVC insulated stranded copper conductor FRLS 1100 V cable and two runs of 4.0 sqmm copper FRLS 1100V cable as earth lead drawn in PVC conduit complete all as specified and as directed by Engineer in Charge. Note : Four runs of of 4.0 sqmm PVC insulated stranded copper conductor and two run of earth wire 4.0 sqmm shall be measured and paid as one unit. Make of cable:- Polycab / Finolex / Havells.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V with IP 66 rating complete all as specified and as directed by Engineer in charge.
Supply and fix Flame proof LED down light fitting , surface mounted of capacity 20Watts made of Aluminium body with IP 66 rating having color temparature 5000 K to 6000 K confirms to IS/IEC.600079-1:2007 complete all as specified and as directed by Engineer in charge. Make: Crompton /Philips/Bajaj/Wipro as approved by GE.
Supply and fix MCB SPN 40 Amp 240 V , 50 Hz, complete all as specified and as directed by Engineer in charge. Make: Havells/ Legrand/ ABB as approved by GE.
Supply and Fix MCB SP 5 to 30 Amp, 240 V, B Series, complete all as specified and as directed by Engineer in charge. Make: Havells/ Legrand/ ABB as approved by GE.
Supply and Fix MCB DB SPN 4 way with 200 Amp copper bus bar single door type complete all as specified and as directed by Engineer in charge. Make : Havells/ ABB/ Indo Asian/Seimens as approved by GE.
Supply and Fix 4 pole MCCB 63 Amp 50 Hz 415 V with rupturing capacity 25 KA along with sheet metal enclosure complete all as specified and as directed by Engineer in charge. Make : Havells/ ABB/ Legrand/Seimens as approved by GE.
Supply and fix MCB TPN 32 A , 415 V having breaking capacity not less than 10 KA complete all as specified and directed by Engineer in Charge. Make: Havells/ Legrand/ ABB as approved by GE.
Supply and fix MCB TPN 63 A , 415 V having breaking capacity not less than 10 KA complete all as specified and directed by Engineer in Charge. Make: Havells/ Legrand/ ABB as approved by GE.
Supply & fix Sheet metal enclosure TPN 4 way single door type with IP 65 protection and rated copper busbar of capacity 200 A without MCB's complete all as specified and as directed by Engineer in Charge. Make: Havells/ Legrand/ ABB as approved by GE.
Material and Labour for copper Earthing complete with copper earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip up to 7.5 mtr as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by Engineer in Charge.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point as specified or indicated including testing on completion complete as directed by Engineer in charge.
Supply and lay burnt bricks sub class 'B' brick for cable protection complete all as specified and as directed by Engineer in charge.
Material and Labour for sand cushioning with river Sand/M sand in two layer,first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and as directed by Engineer in Charge. Note:- Thickness of sand cusioning shall be measured after punning.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmlm, 4.0 Core complete all as specified and as directed by Engineer in charge. Make:- Havells/Legrand/Finolex/Anchor as approved by GE.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmlm, 4.0 Core complete all as specified and as directed by Engineer in charge. Make:- Havells/Legrand/Finolex/Anchor as approved by GE.
Supply and fix Industrial Panel Mounted Plug Socket suitable for IP67 Degree of Protection, 32 Amps rating, 3P+N+E complete all as specified and as directed by Engineer in Charge.
Supply and Fix GI pipe 40mm dia light grade with all fittings laid in trenches for cable protection for road crossing or pole/wall complete all as specified and directed by Engineer in charge.
Material and Labour for Cutting the existing hard standing not less than 25 cm deep and 45 cm in wide for laying of underground cable through GI pipe and making good the disturbed surfaces complete all as directed and as specified by Engineer in charge.
CREATIVE BUILDERS
KENZ CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .