| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.2 LAccepted-AOC HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹16.9 L+₹1.2 L (7.72%)Rejected-Finance | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹17.2 L+₹1.5 L (9.54%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | 4₹18.1 L+₹2.4 L (15.0%)Rejected-Finance | 4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | 5₹19.8 L+₹4.1 L (26.2%)Rejected-Finance C 187 NIRMAN VIHAR DELHI 92 | 5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
23 Jul 2024, 6:00 pmClosed
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIRS/MAINT OF STREET LIGHT, FLOOD LIGHT, MOTORIZED ROLLING SHUTTER ISOLATION TRANSFORMERS AND CONNECTED WORKS INSIDE TECH AREA OF AF STATION GWALIOR
2024_MES_662891_1
8900/1558/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹71,000
Yes
3 Sept 2024
29 Jun 2024
25 Jul 2024
29 Jun 2024
23 Jul 2024
9 Jul 2024
Amount
M & L for checking ,repairing & fixing Street lights/flood lights/tower lights/highmast lights/parts & other connected work as directed in tech area daily and repairing of lights found unserviceable during checking or as per directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of cable/lights etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light almost 100% serviceable complete all as specified and directed. NOTES :- (i) Replacement of spares and connected items shall be measured and paid as supply only under relevant item of schedule (ii) Replacement of unserviceable spare parts/ accessories of the light fittings and replacement of brackets required for defective light fittings shall be measured and paid separately at supply only rates under relevant items of this schedule. (iii) Replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be allowed. (iv) Contractor or his representative will attend unserviceable street light/faulty complaints and ensure completion of fault at the earliest and copy of the report to be submitted to the Engineer-in-Charge. (v) All tools and plants,ladder required shall be brought by the contractor to the site and rate quoted shall deem to include for the same also. (iii) Contractor should provide labour/supervisor everyday at site or perimeter of Tech area to check serviceability of all the street lights and maintain a register duly signed by JE/Engr-in-Charge.Fault should be rectified within 24 hrs by the contractor failing which penalty @ 500.00 per complaint will be recoverd from work done statemenet till rectification.
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 75/80/90 Watts LED luminaires, 230 Volts complete all as specified and directed.
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 100/120 Watts LED luminaires, 230 Volts complete all as specified and directed.
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 150/200 Watts LED luminaires, 230 Volts complete all as specified and directed.
Supply only LED street light fitting 70 Watt 230 V AC outdoor type with high-pressure die-cast aluminum housing and heat resistance complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Note: The cost of fixing will be measured separately under respective item of Sch 'A'
Supply only LED street light fitting 90 Watt 230 V AC outdoor type with high-pressure die-cast aluminum housing and heat resistance complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Note: The cost of fixing will be measured separately under respective item of Sch 'A'
Supply only LED street light fitting 120 Watt 230 V AC outdoor type with high-pressure die-cast aluminum housing and heat resistance complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Note: The cost of fixing will be measured separately under respective item of Sch 'A'
Supply only LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistance complete with driver and lamp complete all as specified and directed Note: The cost of fixing will be measured separately under respective item of Sch 'A'
Supply only LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistance complete with driver and lamp complete all as specified and directed Note: The cost of fixing will be measured separately under respective item of Sch 'A'
Supply only LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistance complete with driver and lamp complete all as specified and directed Note: The cost of fixing will be measured separately under respective item of Sch 'A'
Supply and fix in repair post top lantern LED type 20 watt 230-watt volts AC outdoor type with decorative post top for 360 degrees indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete with necessary 2 core copper wiring and connecting to junction box complete all as specified and directed.
Supply and fixing in repair PVC insulated and PVC sheathed three core Aluminium conductor of size 6.0 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed.
All as per above Item 12.00 here-in-before but copper cable of 1.5 Sqmm 3 core
All as per above Item 12.00 here-in-before but copper sheathed cable 2.5 Sqmm 3 core
All as per above item No 12.00 here-in-before but 10 Sqmm 2 core capper flat sheathed cable complete all as specified and as directed.
Supply and fix three Phase Street Lights Dual Automation System Outdoor application to switch ‘ON’ & ‘OFF’ street lights automatically ‘ON’ at sunset i.e. at 40 Lux ± 5 Lux & switch ‘OFF’ on day break at 80 Lux ± 5 Lux with additional features of Pre-programming the switching with LCD Display for the entire year & By-pass mode for manual operation facility. For energy conservation lights on II nd & III rd Phase to switch off automatically one by one on the desired interval. Capacity 25 kVA including necessary copper cable wiring complete all as specified and as directed. Make Sinetrac/L&T/Legrand/Swadeep or equivelent.
Supply and fix Street Lights Dual Automation System Outdoor application to switch ‘ON’ & ‘OFF’ street lights automatically ‘ON’ sunset i.e. at 40 Lux ± 5 Lux & switch ‘OFF’ on day break at 80 Lux ± 5 Lux with additional features of Pre-programming the switching with LCD Display for the entire year & By-pass mode for manual operation facility. Capacity 16 KVA Single phase with necessary copper cable wiring complete all as specified and as directed. Make Sinetrac/L&T/Legrand/Swadeep or equivelent.
Supply and fixing in replacement PVC Junction boxes of size 300mm X 300mm X 150mm depth, fixed on Lt Pole with 2 Nos MS Clamps of 25 x 5mm FI and nut, bolt, washers including 4 Nos Aluminium bus bars 100 Amps on insulators and 1 No of MCB 10 Amp and locking arrangement with steel sliding bolts including disconnecting and reconnecting cables with suitable lugs complete. Note:- Required cable lugs, terminals MCB of suitable capacity are deemed to be included in the quoted rate.
S & fix in replacement GI pipe 40/50 mm bore, light grade, 1.50 metres long, bent to shape required as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts complete, all as specified and as directed.
Disconnecting, taking out, and removing old existing unserviceable underground, LT XLPE/PVC insulated Aluminium conductor cable of any description and in any position complete including taking down existing protection pipe, etc, for the following sizes from ducts/trenches/poles /pipes, etc complete all as specified and directed:- (a) 10 to 35 Sqmm, 3 ½/4 core
(b) 50 Sqmm, 3 ½ core Note:- Excavation and earth work for taking out the cable shall be measured and paid for separately under appropriate item of Schedule `A'
Re-laying, jointing and testing of serviceable retrieved LT cable from respective item (after thorough inspection of cable) XLPE / PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 Volts grade of any description, laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- Note: Excavation returning refilling will be paid and separately under relevant items. (a) 10 to 35 Sqmm, 3 ½/4 core
(b) 50 Sqmm, 3 ½ core
M&L for Supplying, Laying, jointing, and testing XLPE insulated, armored, heavy-duty, aluminum conductor cable 1100 volts grade, laid in trenches/ducts, floors, fixed to walls, etc. complete all as specified and directed for the following sizes :-. Note:- The cost of taking down the old unserviceable LT cable is deemed to be included in the quoted rate (a) 16 Sqmm 4 core
(b) 25 Sqmm 4 core
M&L for Brick tiles; common burnt clay building bricks sub-class ‘A’ Designation 75 for protection of UG cable complete all as directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in any type soil etc complete all as specified and directed.
Sand cushioning and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. (Note :- Only punned down thickness shall be measured for payment).
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in soft/loose soil etc complete as specified and directed.
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L boring of holes under road, pavement, hard standing by manually depth not less than 75 cm for insertion of GI Pipe of size 50 mm bore light grade for short length complete all as specified and directed. Note :- GI pipe 80 mm dia light grade shall be measured and paid separately under relevant item of Schedule 'A'.
Supply and fixing of GI Pipe 50 mm dia light grade for cable protection complete all as specified and directed.
Supply and fix in replacement of MCB TPN, 415V , 50Hz , 40-100A, 10kA, 'C' type suitable for existing timer control board complete all as specified and directed
Supply and fix in replacement of MCB SPN, 220V , 50Hz ,10kA, 'C' type, 5-32A suitable for existing timer control board complete all as specified and directed
Supply and fix in replacement of MCB SP, 220V , 50Hz ,10kA, 'C' type, 5-32A for street light complete all as specified and directed
M & L for painting of steel tubular poles with two coat of aluminium paint and also marking ZEBRA pattern with alternate yellow and black colour to steel tubular poles 1.5m from the bottom of pole complete all as specified and directed.
Supply and fix inreplacement of PVC conduit pipe 25mm dia heavy duty secured to poleswith necessary clamps and fitting such as bolts, nuts fixed in repairs all as specied and as directed.
Material and labor in repair for maintenance and water-free Conductive Concrete earthing system earthing complete with 100 mm dia of earth enchasing with cement including 17.2 mm solid copper rod electrode with 65 mmx10mm copper bonded flat on top along with providing required holes as shown indrawing to connect the earthing strip, buried directly in ground vertically to a depth not less than 3.14 meter below normal ground level and in160 mm dia bore hole by drilling through any type of soil using mechanical hydraulic boring/drilling machine/Manually after inserting of main earth electrode in the boring hole, rest space to be filled by the excavated soil and approved make of earth enhancing material. The copper bonded electrode is to be connected with 25 mmx3mm copper strip using a copper/brass nut bolt of size 8 mm with copper washer near the top end of the earth electrode is to be connected to Copper strip 25mmx3mm as main earthing lead using copper /brass bolt, nuts, washers, check nuts and strip firmly, earth lead to be connected to earth test point made of phosphorous bronze/gunmetal of size 75mmx75mmx25mm drill and screwed including 03 no.8mm dia 25 mm long hexagonal head screwed. PCC 1:3:6 type C-1 using 20mm graded stone aggregate for inspection chamber (earth pit ) of size 300mmx300mm internal with 100 mm thick at side i.e. total 500mmx500 mm outer side & 300 mm depth with precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle etc including necessary earthwork complete all as specified and directed. Note: (i)The cost of copper earth 20X3mm lead up to and including 7.5 meters only from the top of the earth electrode is deemed to be included under this item.
Material and labor in repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in the ground vertically to a depth, not less than 2.25 meters below normal ground level (with the top edge of earth plate not less than 1.5 meters below ground level) connected to GI strip 25mm x 4mm main earthing lead using galvanized bolts, nuts, and washers all as shown in electrical plate no 3 of MES Schedule Part-I, earth lead connected to earth test point & main switchboard, etc with & including the adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with a funnel and wire mesh, etc complete all as specified and directed. Note:- 1. The cost of earth leading up to and including 7.5 meters only from the top of the earth electrode is deemed to be included under this item and additional earth lead if any is required shall be measured and paid for separately under the appropriate item of Sch. 2. The cost of the earth pit chamber and the cover is deemed to be included in the quoted rate.
Material and labor in repair for earthing complete with galvanized steel earth plate electrode 60×60cm.× 6mm thick, buried directly in the ground (earth pit not less than 2.25 meters deep below ground level) with the top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized earth lead wire 4.0mm dia using bolts, nuts, heck nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Note:- 1. The cost of earth leading up to and including 7.5 meters only from the top of the earth electrode is deemed to be included under this item and additional earth lead if any is required shall be measured and paid for separately under the appropriate item of Sch 2. The cost of the earth pit chamber and the cover is deemed to be included in the quoted rate.
M&L for earth testing and recording the earthing values of copper/GI/Chemical and Maintenance free earthing after disconnecting the strips from the test point terminal from the earthing pit in the presence of JE/User / Engr-in-charge with an approved earth resistance tester complete all as directed. Note: 1. The cost of Earth tester duly calibrated along with labor and Register is deemed to be included in the quoted rate.
S&F for epoxy insulator including fixing on wall/RCC piller with fasteners including de-screwing of strip and re-connecting of the strip on insulator with suitable screw/nuts/bolts etc complete all as specified and directed.
S&F in repair GI funnel with wire mesh for watering the earth pit made to shape and size with using PGI sheet minimum 1.0mm thick and fixed in position complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable / deshaped, aluminum / GI earth strips or taking down conductors of any size and in any position at any location in any height of the building and hangar stacking properly the serviceable strips for re-use in the work including making good the distrurbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L for fixing & connecting in repair GI earth strip 25 mm x 4mm as in roof conductors / down conductor fixed on walls/roofs with saddles/epoxy insulator including screws required at site complete all as specified and directed.
M & L in repair for earth pit of internal size 300mmx300mmx300mm with wall thickness 100mm casting at site with and including PCC base 500X 500X100mm made of PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast 40mm thick RCC cover of (1:2:4) type B-1 (using 20mm graded stone aggregate), rainforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle etc.including removal of old broken unserviceable earth pit from site complete all as specified & directed.
M & L in repair for earth pit cover, pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate, 320mm x 320mm x 40mm thick, cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle with and including necessary form work complete all as specified & directed.
M/s YOGESH ENTERPRISES
M/s Anupam Construction Co.
M/s Yashika Enterprises
M/S KAPIL CONSTRUCTION CO
Kumar Sales Corporation
m/s varsha traders
UNIVERSAL AGENCY
PRAGATI ELECTRICALS AND ELECTRONICS
Om Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .