| 1 | L1₹49.3 LAccepted-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹50.6 L+₹14,505 (0.29%)Rejected-Finance | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹50.9 L+₹50,215 (1.00%)Rejected-Finance 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L3 | Rejected-Finance Not become lowest bidder |
Tender Value
₹46.4 L
EMD Value
₹92,800
Closing Date
27 Jan 2024, 6:00 pmClosed
CWE JHANSI
HQ CWE JHANSI
PROVN OF COOL FACILITY FOR PERISHABLE RATIONS AT BLDG NO P-39 (FRESH GROUP) UNDER GE JHANSI
2023_MES_623535_2
CWE/JHA/J/TOKEN/72 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JHANSI
As per tender documents
9 documents required · 9 mandatory
₹500
GE JHANSI
₹92,800
Yes
8 Feb 2024
30 Dec 2023
29 Jan 2024
30 Dec 2023
27 Jan 2024
10 Jan 2024
Amount
Supply , testing and commissioning of Walk-in Chiller complete all as parameters given below Design parameter of Walk - In Chiller (34.9' x 87.0' x 8.0') :- (a) Insulation Type for Room - For wall and Ceilling :60 mm thick PUF panel with PP/PP, as per the temp required. For floor- 50 mm Thick Puff Slab. (b) ambient temp, + 45 Deg C,Entering Product Temp. +30 Deg C, Pull Down Time 48 hrs & final Chiller room temp. +2 Deg C to + 8 Deg C . (c) Door type -- 34 inch x 78 inch clear opening manual PP/PP type door with both side kick plate. (d ) Power Supply: 415V / 3Ph /50 Hz. (e) Refrigerant: Eco - Friendly R-404a (f) Electrical Load: 5.5 Kwh per Machine (g) Condensor Type : Air Cooled High Ambient Designed Hermetic Compressor Interconnecting piping and wiring between Cond. Unit and Evap. Unit - 20 Rft piping considerd per machine . Note :- (a) The rates quoted are also inclusive of Control Panel which includes temperature setting, display and temperature monitoring setup of above mentioned items. (b) Rates quoted are inclusive of complete AMC which shall be provided by the contractor for 03 years after completion of defect liability period at no additional cost and No additional payment shall be made to the contractor on this ground.
Supply , testing and commissioning of Refrigeration unit -Condensing Unit with Hermetic Compressor Having Capacity of 40,000 BTU/Hr 3 Nos. per room total number of units 4 Nos. No of Condesing units per chamber 4 Nos (3 Working + 1 Standby) ,No of Evaporator units per chamber 4 Nos (3 Working + 1 Standby) complete all as specified and directed. Note : Rates quoted are inclusive of complete AMC which shall be provided by the contractor for 03 years after completion of defect liability period at no additional cost and No additional payment shall be made to the contractor on this ground.
Interconnecting piping and wiring between Cond. Unit and Evap. Unit - 20 Rft piping considerd per machine ,If Piping length exceeds 20 feet (or 6.096 RM) it will be measured and paid separately complete all as specified and directed.
Supply and Fixing of Hanging Arrangement for Ceiling- (a) A wall element to be installed with the respective cut-outs and bore holes for installation in the cold storage cell. (b) The required bores holes and cut-outs should be made on location. (c) The cutting edges and bore holes must be protected against corrosion with zinc primer paint. (d) Hanging the unit on the storage cell wall while pushing against it from the outside (e) Sliding the holding angle against the inside cell wall and tightening it securely with one or two bolts. (f) Inserting the enclosed blind-rivet nuts (of required size) in the bore holes. (g) Bolt the enclosed holding angle to the unit housing together with storage cell wall for attachment to the blind-rivet nuts in the storage cell wall and hexagonal nuts with washers for attachment to the housing) and all other connected items complete all as specified and directed by Engr-in-Charge.
Supply, Testing and Commisioning of Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of Capacity 45 KVA and other connected Item complete all as specified and directed.
Installation of chamber pannels with all joining component for Chiiler unit , Installation of ,Refrigeration Unit 40,000 BTU/Hr, Servo Stabilizer, hanging Arrangement of Ceiling and other connected Item complete all as specified and directed. Note : Rates quoted are inclusive complete AMC shall be provided by the contractor for 03 years after completion of defect liability period at no additional cost and No additional payment shall be made to the contractor on this ground.
Supply, Laying ,fixing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core including cable tray required complete all as specified and directed. .
Supply and fixing MCCB, 415 volts, four pole of capacity 63 Amps, 36 KA, ICS= 100% ICU, class II front face,with thermal- Magnetic release, including spreader terminals, phase barriers, thimbles of suitable size etc, for connection to tap off box enclosure suitable for aluminium bus bar trunking of 400/250 Amps, 3 phase, 4 wire and making electric connections complete all as specified and directed.
Supply and fix in replacement of MCB distribution board, VTPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fix in replacement of MCB TPN 40 Amps 10 KA "C" series 415 Volt complete all as specified and directed.
Supply and replacement of MCB SP 6 to 32 Amp 10 KA "C" series 230 Volt complete all as specified and directed.
Supply, Installation,Testing and Commisioning of 82.5 KVA/66 KW Canopies Silent Diesel Generating set powered with 3 Cylinder/IN-line-Engine model at 0.8 power factor, at NTP Conditions, 415 V, 50 Hz coupled with 3 phase Alternator mounted on common base frame along with AMF PANEL, Battery with Cables(12V/88AH),Fuel tank (130 Ltr capacity), AVM Pads and other standard accessories complete all as specified and directed.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- (a) The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. (b) Contractor must test/ensure Earthing resistance value less tham 1 Ohm and Submit Earth test result to Engr-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed.
Material and labour for PCC 1:4:8 Type D2 (40mm graded stone aggregate) as in base concrete for DG set foundation complete all as specified and directed.
Material and labour for PCC 1:2:4 Type B1 (20mm graded stone aggregate) including necessary form work for DG set foundation complete all as specified and directed.
Excavation in trenches n.exc 1.5m deep and n.exc 1.5Mt wide and getting out in hard dense soil complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
S&F of Structural steel for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and incl one coat of red oxide primer with and incl preparation of new surface of steel not exc 10 cm in width or girth, complete all as specified and directed.
M&L for pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed.
M&L for pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed.
M&L for 75mm PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in, sub base, plinth protection and finished even and smooth without using extra cement complete all as specified and directed.
M&L for brick work with sub-class B bricks straight or curved on plan exc 6 Mtr mean radius built in CM (1:6) complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying two coats of oil bound distember over 1 mm putty and a coat of chalk whitening primer preparating to make the surface to be plain and smooth before primer complete all as sppecified and directed.
Preparing newly plastered surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of exterior grade cement based primer complete all as specified and directed.
M&L for Granite 20 mm thick over including 10 mm thick CM 1:4 (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rubbing and polishing complete all as specified and directed.
Returning filling in trenches including spreading leveling and well ramming with water complete n.exc 25 cm thick in each layer in soft/loose soil complete all as specified and directed.
M&L for factory made PU coated, machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment made of PVC moulded (or rubber mould) with vibrating system, with and including 50mm thick sand cushioning, complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in coping complete all as specified and directed.
Note :- (a) For Ser No 1.00, 2.00, 3.00, 4.00 and 7.00 of BOQ as mentioned above :- Tenderer/contractor/bidder shall provide complete AMC for 03 (Three) years after completion of defect liability period at no additional cost and No additional payment shall be made to the contractor on this ground. Rs 1,50,000/- will be retained other than retention money and will be released after 3rd, 4th and 5th year from completion date as Rs 50,000/- after 3 year, Rs 50,000/- after 4 years and Rs 50,000/- after 5 year. Also amount may be released at the time of final bill after submission of requisite amount of FDR/BGB. (b)Tenders/ bidders are advised to visit the site and raise any ambiguity if any before the bid submission start date.
M/s Ratan Mechanical Works
ADARSH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .