Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.4 LAccepted-AOC 5574 A KANSHI RAM MARKET NEW CHANDRAWAL KAMLA NAGAR DELHI 07 | 1 | Accepted-AOC L1 | |
| 2 | 2₹9.5 L+₹18,506 (1.98%)Rejected-Finance | 2 | Rejected-Finance 2 |
Tender Value
₹9.2 L
EMD Value
₹18,897
Closing Date
14 Mar 2024, 12:00 pmClosed
EEE/RZ
EEE/RZ
Repairing of electric motor pump set ,DG set and other allied works at khadda basti and Raja vihar pump house under RZ
2024_MCD_190519_1
EE/Elect.and Auto/RZ/2023-24/TC/09.1
Open Tender
Electrical Works
Item Rate
120 days
EEE/RZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹18,897
15 Jul 2024
8 Mar 2024
14 Mar 2024
8 Mar 2024
14 Mar 2024
8 Mar 2024
Amount
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
19.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
2.2.13:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA, FPMCCB
2.2.16:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 Amp, 36 KA, FPMCCB
18.6.2:Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm. Dia
18.14.7:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia
5.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
122.1.31:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*35 sqmm
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.189:SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switch gears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
OD29706/2023-2024:Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV Danger plate and grounding the protection system in suitable quality of CC etc as reqd.
OD29707/2023-2024:"Providing & Fixing of M S flange with required Nut bolts & Packing sheet etc. Complete as required of following Dia: 150 mm (10 mm thickness)"
OD29708/2023-2024:"Providing & Fixing of M S Bend with required Nut bolts & Packing sheet etc. Complete as required of following Dia: 150 mm short bend C-Class"
OD29709/2023-2024:Repairing of the following dia/models of storm water pump i/c dismantling of pump set from base frame by cutting of nut bolts of suction side and delivery side i/c loading/unloading by skilled labour, to & fro cartage along with replacement of its parts/accessories i/c gland plate/spilt gland, MS Lock nut with Lock washer, impeller,Keys & coupling, stud of Gland plate and all packings i/c oiling, greasing, replacement of required body studs & nuts, coupling tyre, required machining works for proper balancing of complete pump unit and minor repair works and dynamic balancing with existing motor i/c installation, testing and commissioning on full load etc. as required complete in all respects Having suction of 150 mm
OD29710/2023-2024:Supply of Cable Groomet for 15 HP sewage submersible pump
OD29711/2023-2024:Supply of O Ring set for 15 HP sewage submersible pump
OD29712/2023-2024:Supply of Lead Groomet for 15 HP sewage submersible pump
OD29713/2023-2024:Supply of Mech. Seal (lower) for submersible pump
OD29714/2023-2024:Supply of Mech. Seal (Upper) for submersible pump
OD29715/2023-2024:Supply of Seal holder for submersible pump
OD29716/2023-2024:Supply of ball bearing (lower) for submersible pump
OD29717/2023-2024:Supply of ball bearing (Upper) for submersible pump
OD29718/2023-2024:Supply of Pump Base for submersible pump
OD29719/2023-2024:Supply of Seal housing for sewage submersible pump
OD29720/2023-2024:Supply of hardware for sewage submersible pump
OD29721/2023-2024:Supply of Rewinding kit for sewage submersible pump
OD29722/2023-2024:Wearing Ring for submersible pumps
OD29723/2023-2024:Cable Gland for submersible pump
OD29724/2023-2024:Oil for submersible pump
OD29725/2023-2024:Impeller for submersible pump
OD29726/2023-2024:Labour charge for Repairing & Balancing of rotor
OD29727/2023-2024:Job work Labour Charge for rewinding
OD29728/2023-2024:Supply of PVC Cable 4 Core 2.5 Sqmm. + 2 core 1 sqmm.
OD29730/2023-2024:Labour charge for Fixing Upper & Lower Bearing
OD29731/2023-2024:Labour charges for dismantling/assembling/painting.
OD29732/2023-2024:Providing of Oil filter spinon 1 LTR for Kirloskar Make -Model No -4R1040 -82.5KVA
OD29733/2023-2024:Providing of Fuel Filter (Secondary) for Kirloskar Make -Model No -4R1040 -82.5KVA
OD29734/2023-2024:Providing of Fuel Filter (Primary) for Kirloskar Make -Model No -4R1040 -82.5KVA
OD29735/2023-2024:Providing of Air Filter Kit -A-4R1040BS3 INDL for Kirloskar Make Model No -4R1040 -82.5KVA
OD29736/2023-2024:Providing of Koel Care Genuine Coolnat Premix for Kirloskar Make -Model No -4R1040 -82.5KVA
OD29737/2023-2024:Providing of Koel Premium Oil 13 Ltr. for Kirloskar Make Model No. 4R1040-82.5KVA
OD29738/2023-2024:Repair charges towards for the Silencer Modification with Pipe, Nut Bolt Flange
OD29757/2023-2024:Service charges towards servicing of your DG set
OD29758/2023-2024:Providing of Kit ,Turbo repair HC5A for Kirloskar make
OD29898/2023-2024:Supply and fixing Changeover switch 100 A with enclosure including connections on the existing Panel board etc as required
OD29983/2023-2024:Rewinding Kit i/c enamel copper wire , Nomex paper , sheet paper , varnish ,Lead wire , transformer fiberglass sleeves etc as reqd for 5 HP submersible pumps
OD29984/2023-2024:Supply of Cable Groomet for 5 HP Submersible Pump
OD29985/2023-2024:Supply of Set of O Ring for 5 HP Submersible Pump
OD29986/2023-2024:Supply of lead groomet for 5 HP submersible pump
OD29987/2023-2024:Supply of Mechanical Seal (lower) for 5 HP submersible pump
OD29988/2023-2024:Supply of Mechanical Seal (upper) for 5 HP submersible pump
OD29990/2023-2024:Supply of Ball bearing (upper) for 5 HP submersible pump
OD29991/2023-2024:Supply of Ball bearing (lower) for 5 HP submersible pump
OD29993/2023-2024:Supply of Double Sheathed PVC copper conductor cable 2.5 X 4 sq mm for 5 HP submersible pump
OD29994/2023-2024:Supply of Diffuser for 5 HP submersible pump
OD29995/2023-2024:Supply of Hardware for 5 HP submersible pump
OD29996/2023-2024:Labour charge for Dismantling/assembling/testing/Painting etc.
OD29997/2023-2024:Labour charge for repairing & balancing of motor
OD29998/2023-2024:Labour charge for Rewinding
B S TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .