Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹73.0 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹74.9 L+₹1.2 L (1.64%)Rejected-Finance UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹79.3 L+₹5.5 L (7.48%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹83.9 L+₹10.1 L (13.7%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L-4 | Rejected-Finance Being L-4 |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
21 Jun 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
ADDN / ALTN AND SPECIAL REPAIRS TO NS-117 AT NSV GHATKOPAR
2024_MES_654115_1
8477/E8
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.9 L
Yes
31 Aug 2024
15 May 2024
24 Jun 2024
15 May 2024
21 Jun 2024
7 Jun 2024
Amount
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Dismantling of cement concrete ( reinforced) as in roofs, floors ( other than ground floors), beams, staircase, landing, chajjas , parapet, water tank and similar suspended work etc with the help of machanical cutter .without disturbing useful RCC, and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete as directed
Resecuring or easing and adjusting, without taking down shutters of any description exc 1 sqm each but not exceeding 2 Sqm each complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or any pattern) including all fittings heads, shoes, bends swan necks etc including cleaning or refixing removal to stores.
Demolition of concrete of any description (un re-inforced) in any position not otherwise described and provided etc
M&L reinforced cement concrete 1:1.5:3 type A-1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall,landing, balconies, shelves and like including bonding agent , complete all as specified (reinforcement to be measured & paid under respective items).
M&L for 75 mm thick cement concrete type C-2,1:3:6 (40 mm graded aggregate) as in plinth protection finishes and fair without using extra cement including forming 12 mm thick expansion joint filled with sealing compound Grade 'A' etc complete all as specified and directed.
M&L for cement concrete Type E2 1:5:10 using 40 mm graded aggregate mass concrete complete all as specified and directed
M&L providing cement concrete type B0, 1:2:4 (12.5mm graded aggregate) 25 mm thick as in flooring finshes the surfaces even and fair without using extra cement complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 450x350x7mm thick in vertical surfaces such as skirting/dado and jointed in neat cement slurry and pointed in white or coloured cement to match and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surface etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab for steps in single piece with round nosing laid over cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of of the slab including rubbing and including over 15mm thick screed bed or bedding layer in CM1:6 complete all as specified and as directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab as in riser of steps, skirting, window cills,dado and pillar in single piece, laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortor 1:6 complete all as specified & directed.
M&L for brick work with sub-class 'B' bricks, straight, or curved on plan to any radius as in half brick thick wall in CM 1:4 complete all as specified and directed.
M&L for 20 to 25mm thick machine cut machin polished cudappa stone slab for kitchen platform jointed and set in CM 1:6mm thick screed bed and including rounding to edge of stone slab one side edge complete all as specified and as directed.
M&L three numbers of serration as in treads of steps in single piece kota stone for staircase .complete all as specified and as directed.
M&L Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations .complete all as specified and as directed.
Supply and fix granite slabs 20 mm thickGranite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over incl 15 mm thick screed bed in cement mortar 1:6 over including finishing even and fair complete all as specified.
M&L for machine cut and machine polished green marble 18 to 20 mm thick on horizontal or vertical surfaces as in cooking platform , pre polished kota stone slab as in riser of steps, skirting, window cills,dado and pillar in single piece, laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L 20 mm thick cement plaster in two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/ or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 12 mm thick and finishing coat of 8 mm thick final rendering,including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing etc. complete all as per specifications & as directed by the EIC (Note : - (i)Work shall be executed at Multiple places as per required and at any height upto five storied bldg.
M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over one coat of alkali resistant primer including application of 3mm wall care putty for smooth finish.etc complete all as specified and directed .
M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper over a coat of primer including application of 3mm wall care putty for smooth finish.etc complete all as specified and directed .
M & L for preparation of new plastered surfaces on ceilings and applying two coats of oil bound distemper with roller over complete all as specified and directed.
M&L for complete removal of existing surfaces on ceiling and applying two coats of oil bound distemper application of complete all as specified and directed.
M&L for preparation of NEW plastered walls surfaces & applying two coats of chemical waterproofing treatment (601 raincoat of pidilite or equivalent) on wall & chajja, terrace & parapet wall, such as Flexcoat, Beckcoat, Exshield etc or equivalent including filling of cracks in walls/concrete with " Crack-X" of pidilite or equivalent complete as per manufactures instructions, all as specified and directed.
M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of chemical waterproofing treatment (601 raincoat of pidilite or equivalent) on wall & chajja, terrace & parapet wall, such as Flexcoat, Beckcoat, Exshield etc or equivalent including filling of cracks in walls/concrete with " Crack-X" of pidilite or equivalent including preperation of OLD surfaces complete as per manufactures instructions, all as specified and directed.
M&L for preparing new or previously untreated wood and wood based surface of any description, over 10cm in width or girth, not other wise described and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for for preparation of old wooden surfaces of any description or not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed.
M&L for preparation of wooden surfaces any description and treated with tar or coal tar black paint.
Supply only integral water proofing compound.
S&F aluminium powder coated in approved colour (Thickness of powder coating not less than 50 micron) frame for door, windows, ventilators etc.with one or more rebates including joining cleat for fixing etc.fixed type/ louvered window or ventilator without sash bar,aluminium including necessary joining cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws, sliding rollers, Rubber gasket etc.compleate all as specified compleate all as specified. Notes: 1. Glazing shall be measured seperately. b) Item shall be paid as per weight of aluminium section.c) The rate quoted shall be inclusive of neoprene beading,glazing clips,screws, etc., as required which shall not be measured for arriving the weight.d)the rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area. 2. The size of aluminium section shall be as shown in HQ CE(N)MZ TD Drawing No TD/2021/ 01 to 05 and Sill to be provided as shown in HQ CE(N)MZ TD of Sill Type 'A' and 'B' repectively. The contractor shall provide Granite stone slab (The rate of granite shall be paid seprately under repestive item) with width equal to the thickness of wall all around the window opening any cutting required to jamb and sill to accommodate the aluminium window shall be done including make good the disturbed surfaces shall be include in the quoted rate againt the item.
S&F only 4mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator in squares n exc 0.50 Sqm each pane all as specified & as directed by EIC.
Supply only for 6mm thick bakelite sheet prelaminated both side with decorative choice laminations with aluminium frame cuboard shutter work complete all as specified and directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F II nd class Hard Wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc all as specified
S& F 35mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze, etc ( with sash bars), edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing glass, etc size of members of shutters as specified & directed in SSR Part-I , section 8, clause 8.20 (a) complete all as specified and directed.
S& F 2nd class HW 35 mm thick,plain, framed, panelled shutters (any numbers of panels), with pannels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face neneers;fixed to chowkats complete all as specified & directed.
S&F Solid PVC door frame (Chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F for Factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottam rails. MS frame shall be covered with heat moulded plain colour PVC 'Ç'channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rails and bottam rail on either side and as gap insertfor top rail and bottam rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in frame at site complete all as specified and as directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks or aluminium wire staples,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
S&F bands, steps, supports or stays for rain water, hooks (stay) heavy for large gates, hook and pintle hinges clamps, hold fasts wall ties, hooks for hanging james and similar small articles Fe-290 Gde-E-165 complete all as specifed and directed.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggregate as in hold fast, coping ,cills ,steps, seismic and other similar bands, plinth course, string course, parapets, railing, bed plates, kerbs and the like including weathering,slightly rounded or chamfered angles and throating as directed.
S&F for 18 mm thick termite resistant and water proof, both side prelaminated wooden plywood one side with decorative choice lamination, and other side plain white lamination total thickness not more than 22 mm thick, as in cup board shutters & frame , including piano hinges, wardrobe/ finch lock & PVC lipping on all exposed edges of same texture and shade, with complete all as specified. Note: 1) Design & layout of wardrobe and pattern / colour of lamination to be approved by GE. 2) Thickness of laminated not less than 1mm for inside plain white type & 1.5 mm for outer decorative type. The laminate shall be fixed to base with approved adhesive as per manufacturer's instructions and machine pressed to ensure proper bonding with base ply and avoid air pockets . 3) Frame to be fixed to walls, soffits & base of cupboard with fasterners
S & F Continuous (piano) hinges, of brass, bright finish or elec trogalvanised and avg width 40 mm for fixing of shutters . complete all as specified and directed.
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified.
S&F in repairs 40mm dia and 75mm long, extrruded fancy type SS handle for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts , screw and washer of mild steel bright finished , complte all as specified.
S & F 125 mm hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws
S&F in repairs for 20mm dia curtain rods anodised aluminium alloy, power coated with fixing brackets, stops, rollers etc complete all as specified and directed
S/F stainless steel butt hinges 125mm size medium wt coIled rolled.
All as in item 62 above but fixed in repairs
S&F anodised aluminium alloy body door stopper 150 mm size
S&F anodised aluminium extruded handles 150 mm size.
All as in item 65 above but fixed in repairs
S&F aluminium anodised barrel tower bolts of extruded section 200 mm size.
All as in item 67 above but fixed in repairs
S/F aluminium anodised bow handle 75 mm long cast type.
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy.
All as in item 70 above but fixed in repairs
S & F Hasp and staple aluminium anodised 100mm
S & F Al Hat pegs and hooks solid body, 125 mm to 175 mm
S&F 100mm Aluminium anodised, tower bolts of extruded section
S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete
S & F repair for Toilet and Bathroom External Downtake Pipelines for Toilet Domestic Water Supply Downtake, Toilet Soil Water Downtake Pipe, Bathroom Solar Hot Water Supply Downtake, Bathroom Waste Water Downtake Pipe and Bathroom Water Supply Downtake Pipes fixing done with Pipe Supporting Clamping System consists of Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Water Supply Pipe 1 1/4" GI pipe - 1 no.; 2. Soil Water Pipe 4" CI - 1 no.; 3. Solar Water Pipe with Aluminium insulation casing 3" PVC size - 1 no.; 4. Waste Water Pipe 3" CI - 1 no. and 5. Bathroom Water Supply 1 1/4" GI pipe - 1. no. running from Terrace to Ground Floor Vertical Fixed line with wall distance 4": Pipe Support Clamping made of 1. Profile Bracket Type A3 (Wall Distance 4") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 45" (Continuous Slotted "C" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket of A3 Type (Wall distance 4") - 3 Nos. 2. Continuous Slotted C Channel of B3 Type Size 45" - 1 No.; 3. U Bolt R/M for 1 1/4" GI Pipe Dia. - 1 No.; U Bolt R/M for 4" CI Pipe Dia. - 1 No.; U Bolt R/M for 3" PVC Pipe Dia. - 1 No.; U Bolt R/M for 3" CI Pipe Dia. - 1 No.; U Bolt R/M for 1/4" GI Pipe Dia. - 1 No. 4. Justi Khilla GI coated 2 1/2" - 6 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing of CE Navy Mumbai TD/2023/01. Make : Shaivi or equivalent as approved by GE
S & F repair for Kitchen External Downtake Pipelines for Waste Water Pipes and Water Supply Pipe fixing done with Pipe Supporting Clamping System consists of Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Waste Water Pipe 3" CI (75 mm) - 1 no., 2. Solar Water Pipe with Aluminium insulation casing 3" PVC size - 1 no.and 3.. Water Supply Downtake 1 1/4" GI - 1 no. running from Terrace to Ground Floor Vertical Fixed line with wall distance 4": Pipe Support Clamping made of 1. Profile Bracket Type A3 (Wall Distance 4") made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 15" (Continuous Slotted "C" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.for one unit : 1. Profile Bracket of A3 Type (Wall distance 4") - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 15" - 1 No.; 3. U Bolt R/M for 3" CI Pipe Dia. - 1 No.; U Bolt R/M for 3" PVC Pipe Dia. - 1 No.; U Bolt R/M for 1 1/4" GI Pipe Dia. - 1 No. 4. Justi Khilla GI coated 2 1/2" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing of CE Navy Mumbai TD/2023/01. Make : Shaivi or equivalent as approved by GE
S & F repair of RISER Overhead Tank Water Supply pipelines fixing done with Pipe Supporting Clamping System consists of Mono Bracket + U Bolt System - RISER Water Supply take pipes 1 1/2" GI - 1 no. running Vertical Fixed line from 1st floor to Ground floor with wall distance 1": Pipe Support Clamping made of 1. Profile Bracket Type A1 (Wall Distance 2") of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted "C" Channel B3 Type to be used of size 10" (Continuous Slotted C Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip + Zn Al flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Mono Bracket for 1 1/2" GI pipe; Wall distance 1" - 1 Nos. 2. U Bolt R/M for 1 1/2" GI pipe Dia. - 1 nos and 3. Justi Khilla GI coated 2 1/2" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing of CE Navy Mumbai TD/2023/01. Make : Shaivi or equivalent as approved by GE.
S & F repair of Rain Water Downtake pipelines fixing done with Pipe Supporting Clamping System consists of Rain Water Bracket + U Bolt System - Rain Water Downtake Pipe 6" PVC - 2 nos. running Vertical Fixed line from Terrace to Ground floor with wall distance 3": Pipe Support Clamping made of 1. Rain Bracket Set Wall Distance 3" of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Bracket Set for 6" PVC pipe, Wall distance 3" - 1 Nos. 2. U Bolt R/M for 6" PVC pipe Dia. - 1 nos and 3. Justi Khilla GI coated 2 1/2" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing of CE Navy Mumbai TD/2023/01. Make : Shaivi or equivalent as approved by GE
S & F repair of Rain Water Downtake pipelines fixing done with Pipe Supporting Clamping System consists of Rain Water Bracket + U Bolt System - Rain Water Downtake Pipe 4" PVC - 4 no. running Vertical Fixed line from Terrace to Ground floor with wall distance 3": Pipe Support Clamping made of 1. Rain Bracket Set Wall Distance 3" of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Bracket Set for 4" PVC pipe, Wall distance 3" - 1 Nos. 2. U Bolt R/M for 4" PVC pipe Dia. - 1 nos and 3. Justi Khilla GI coated 2 1/2" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified in the Technical Drawing of CE Navy Mumbai TD/2023/01. Make : Shaivi or equivalent as approved by GE
Dismantling cast iron pipes of any description etc complete all as specified and directed
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F PVC floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25 mm complete all as specified and directed.
S&F 25 mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15 mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20 mm complete all as specified and directed.
S&F 15mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
S&F 20mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 40 mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 15 mm bore complete all as specified and directed.
S&F in repair low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc. Complete all as specified and directed.
S&F GI tube heavy grade of 40 mm bore with all fittings and fixed complete to walls and ceilings or laid in floors or sunken portion etc complete all as specified and directed including taking down old one complete all as specified and directed.
S&F 2000 ltrs Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I and fixing of Ball valve of size 15mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F in repairs CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed .
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.
S&F in repair brass Tubular towel rail with hook 20 mm D type dia 600mm long between flanges of fixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
S&F Soap dish, Stainless steel fancy type approx size 160x160x90mm complete all as specified and directed.
S&F in repair fancy type chromium plated brass two way bib cock suitable for 15mm bore pipe complete all as specified and directed. 2 Way Bib Cock with Wall Flange
S&F stainless steel of AE - SI 316 grade tubular towel ring including apair of CP brass bracket complete all as specified .
S & F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP bracket gaurd and railling 60 cm long complete all as specified.
S&F in repair fancy type glass corner 300mm radius of 10mm thick toughned glass with CP railing fixed with screws fancy type complete all as specified .
S&F stainless steel plate rack steel grade SS 304 of thickness 0.63mm of standard size weight not less than 5 .50kg complete all as specified and directed.
S&F in repair fancy type 15mm dia chromium plated fancy type wall mixer hot & cold with long swan for kitchen sink fixing and connection to pipes complete all as directed.
S & F S&F sinks made of stainless steel 1mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar onbowl type overall size 23" L x 18"W undermount kitchen Sink with basket Strainer complete all as specified and as directed .
Taking down existing tar felt treatment from the roof including CM removing the debris off the premises and cleaning the roof complete all as specified and directed.
M&L for roughening old concrete surface by picking, sweeping clean and washing down with water to remove weak concrete/plaster dust etc all as specified and directed
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
Supply and application of 7 layer SHR Water proofing coating system on leaking concrete surface by through surface preperation ,opening of cracks , followed by one absorption coat of thermacool WP51, nano modified, UV resistant elastomeric clear coat having min 50% solids, filling of cracks, then over coating with sandwich coat of elastomeric (Thermacool WP51 +Cement) water proofing layer with 80 GSM non-woven fibre mesh, application of 3rd coat of elastomeric water proofing layer having + 450% elongation, tensile strength min 2.2 MPa and then top coated with two coats of thermacool 0.3c pure acrylic based UV resistant, non yellowing bio organism resistant ( antifungal, anti bacterial) solar reflective coating confirming to BIS STD IS 17218:2019 with pull off adhesion 2.8 MPa , passes 20 HRS accelerated durability test , suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/ Ltr/ 2 coat, DFT 100-120 microns using brush, roller, arless spray gun as applicable. or equivalent make and their guidelines of similar product like "Heataway" from Dr.Fixit/ "Smart care damp proof " from Asian Paints/or any other approved make. Or equivalent authorised applicator with 10 year guarantee
RELIEVING STRUCTURAL MEMBERS Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately. Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ .
Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main r/f. (if required in the opinion of the Consultant), carefully with chisel and hammer Providing and applying ‘Rusticide SS’ Rust passivator or equivalent as specified in the Brand Names to existing r/f. bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directedProviding and applying “Polyalk EP” or equivalent as specified in the Brand Names.Polymer modified cement mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering. Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ and charges to be borne by the contractor.
FILLING AND REINSTATING OF SEPERATION CRACKS:- Opening the seperation cracks at the junction of RCC and masonry whereever directed and instruted into V grroves 2" to 3" from either side of the cracks by carefully making the areas to be opened up using a cutting machine and skilfully/ carefully chiselling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the consultant Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ and charges to be borne by the contractor..
Moistening the cracks , providing and applying priming/bonding coat of slurry made out of " Polvalk EP" and cement ( or equivalent as specified in the list of brand names) in proportion 1:1 to surfaces prepared as instructed and directed.Filling the cracks /grooves by providing and applying "Polvalk EP" polymer modified cement mortar (or equivalent as specified in the list of brand names ) in proportion of 1:5:15( Polyalk EP:Cement:Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster including hand packing, curing and making the surface similar to external plastering using wooden floats/ punch etc complete all as specified and directed. Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ .
Drilling holes of required size upto 16mm diameter and 50mm depth in concrete and cleaning the same as directed Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ .
Providing and fixing 12mm diameter aluminium/ PVC injection nipples and securing the same as directed & providing and injecting cementitious grout using CEBEX 112 additive of Fosroc at the rate of 225 grams per bag of cement and using suitable mechanical gun/ pump including mixing etc complete Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ .
Providing & fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing, Micro concreting as per Consultants Instructions and directions. Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ .
M&L for TMT bars 10mm dia & over cut to length bent to shape required incl cranking bending, spirally for hooping for columns hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9mm dia by placing in position new reinforcement bars including tack welding to existing reinforcement bars all as specified and directed by Engg-in-charge. Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ and charges to be borne by the contractor.
Providing and laying super fluid Micro concrete Roffe crete repairs (or equivalent as specified in the list of brand names) in beam bottoms, columns, slabs etc incl mixing with 5mm to 10 mm size in aggreagate, waterproofply wood/steel plate shuttering, pouring, temping, consolidating, curing etc complete as per manufacturers specification and consultants instruction. The item shall be paid on actual consumption of Micro concrete Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ and charges to be borne by the contractor. .
Glass Fiber Wrapping System:.Providing & laying applying Glass Fiber sheet wrap at structural members including.Surface Preparation: Grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.Profiling: Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc., complete.Wrapping: Wrapping the Glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., Repeat the same procedure for multiple layer with interval of 8 hours.Sand Pasting: Applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement: Per Sq.Mt of Fiber consume and not application of surface area.) Note: Structural repair item to be supervised/carry out under the Supervision of Structural consultant who carried out audit and the unit rate for the same to be included in BOQ and charges to be borne by the contractor.
M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/ chajjas (one side half circle crank ), fixed with self tapping screws complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-1979
S&F Mild steel work of Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, mild steel frame work for bird proofing fixing of XPM jalli, (Beam, Angle, Channel, Plates or flat section etc), distance pieces, cleats, bracing, etc, of grade E-250, Fe-410W, quality 'B' including welding, complete all as specified and directed.
M&L for post construction anti- termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes etc in repairs.
M&L for post construction anti- termite of soil / concreate under existing floor using chemical emulsion @ 1 liters per hole 300 mm apart including drilling and plugging 12 mm dia holes with cement morter 1:2 to match the existing floor etc complete all as specified and directed.
M & L for post construction anti - termit treatment at points of contract of wwod work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
Taking down carefully unserviceable point wiring of any type & pattern (Light/Fan/Socket or power) including unserviceable fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
M & L for concealed point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC conduit (minimum 20mm dia) concealed in wall etc (also including cutting chiseling in wall and making good the same in CM 1:3 to match with the adjoining surfaces) with all accessories, fittings, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed. Note: Modular flush box and inner/outer plates measured and paid separately.
-ditto- All as per item No. 145 above but for One 2pin/3 pin socket outlet 5 Amps on independent board.
-ditto- All as per item No. 145 above but for One 2pin/3 pin socket outlet 5 Amps on same board with other switches , complete all as specified and directed.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/Polycab/Havells and PVC conduit Make: Precision,Plaza) Note: Modular flush box and inner/outer plates measured and paid separately.
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed.Make:Legrand/Havells/polycab Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for ceiling rose three terminals AC 240 volts 50Hz complete all as specified of make: Havells/Legrand/Cona
Supply and fixing bell ding dong 240 volt Ac 50Hz complete all as specified and directed.
Supply and fixing modular ceiling fan regulator 120 watt 2 module complete all as specified and directed.
M&L for switch modular one way 6/5 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for switch modular one way 16/20 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L modular bell push 6Amp 1 module complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA,B Curve rating complete all as specified and directed.Make -Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 6 to 32 Amps breaking capacity 10 KA,B Curve rating complete all as specified and directed.Make -Legrand/Schneider/Siemens
Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 4 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular metal flush box 12 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 1/2 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 4 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 12 module complete all as specified and directed.
Material and Labour for tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of LED ,PF>0.90, LED light luminous efficiency shall not be less than 90 Lumens/Watt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking ,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make : “Havells/ Crompton/ Philips/Wipro
Material and Labour for tube light fitting LED 10 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of LED ,PF>0.90, LED light luminous efficiency shall not be less than 90 Lumens/Watt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make : “Havells/ Crompton/ Philips/Wipro
Supply and fix in repairs highly efficient high power 35 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting. Make : “Havells/ Crompton/ Philips/Wipro
Taking down existing ceiling fans and re-fixing the same ceiling fan any sweep including provisioning of cable from celing rose to c/ fan and spray painting of ceiling fan with two coats of synthetic enemal paint complete all as specified and directed.
M & L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No 3 of MES Schedule Part – I of 2009.
Supply install, test and commissioning of Powder coated LT Feeder panel cubical indoor type Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved IP-54 protection factory fabricated made out of 2 mm thick CRCA sheet as per CA & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm but of detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size. The panel shall be dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, removing of Existing energy meters and re fixing the energy meters at new panel & Reconnecting the cables to new panels and including PCC foundation, excevation, grouting bolts and followings items as per below description:- a) Copper bus bar 160 Amps for 3 phase and Neutral b) MCCB TPN 100 Amps 415 Volt 25 KA - 1 Nos c) MCB SPN 40/32 Amps, 10 KA 230 Volts - 11 Nos d) Digital Ameter -01 No e) Digital Voltmeter - 01 No f) Space for Fixing 11 Nos of Single Phase Prepaid Energy Meter of Capacity 40 Amps g) RYB Indicators - 1 Set Make of MCCB,MCB, Shall be - Legrand,ABB,Indo Asian,Siemens,Schnider Electric Note - The lay out drawing of the panel shall be got approved by the contractor from the GE before panel fabrication and shall be fabricated from CPRI approved manufacturer.
Supply and fix exhaust fan, Metal body AC single Phase. 230V of size 300mm sweep with louvers, blades, and frame , connected items etc complete all as specified and directed .
M & L for electronic circuit PCB for BLDC Ceiling fan of 1200 mm sweep as per OEM etc complete all as specified and directed .
Joy builders
MUKESH CONSTRUCTION CO
Vishal Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .