Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹17.7 L+₹1.9 L (12.0%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹18.0 L+₹2.3 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | Not Admitted-Finance | - | Not Admitted-Finance Others-The bidder has one work on hand in this division and in addition he also being the L1 for the Tender No.12 dated 23-06-2023 and Tender No.32/EEY/2023-24 by which he is fulfilling having three works, this bid is not admitted as per the NIT Condition. |
Tender Value
₹18.5 L
EMD Value
₹37,074
Closing Date
22 Jun 2023, 4:00 pmClosed
EE, PWD, Yanam
Chinta Street, PWD, Yanam
Improvements and Facelift to the OPD block Annexure building at Govt. General Hospital, Yanam
2023_PWDC2_12924_1
34/EEY/2023-24
Open Tender
Civil Works
Item Rate
90 days
Yanam
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
₹37,074
19 Jul 2023
13 Jun 2023
23 Jun 2023
13 Jun 2023
22 Jun 2023
13 Jun 2023
Amount
13.48.1 Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm.
14.43 Removing white or colour was by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
18.48A Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank-Circular tank.
18.7.4 Providing and fixing Chlorinated Polyvinnyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete - internal work - exposed on wall - 32mm nominal outer dia pipes.
18.7.3 Providing and fixing Chlorinated Polyvinnyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete - internal work - exposed on wall - 25mm nominal outer dia pipes.
16.96 Supplying fixing and commisioning of Suguna / Texmo / Sharp 2 HP monoblock pumpset slow speed single phase motor. The rate include the cost of pumpset , pumpset fixing in position and test run etc.complete
19.33.1 Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes-110mm diametre.
19.33.1A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single tee with door - 110 x110x110 mm.
19.33.1C Providing and fixing on wall face / column face unplasticised - PVC mould fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend 110 mm.
19.33.2 Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter.
19.7.1.2 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone agregate 20 mm nominal size), foundtion concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design -inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty ) 455 X 610 mm internal dimensions , total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) - with sewer bricks conforming to IS :4885
15.2.1 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
2.27 Supplying and filling in plinth with river sand under floors, including watering, ramming consolidating and dressing complete.
4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
13.6.1 20mm Cement plaser of mix 1:4 (1 Cement: 4 coarse sand).
17.7.2 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps ,32 mm C.P.brass waste of standard pattern, including painting of fittings and brackets cutting and making good the walls wherever required - white Vitreous China wash basin size 630x450 mm with a single 15 mm C.P.brass pillar taps.
NON-PSR Labour Charges for chipping the spalled and detoriated cover concrete, cracked mortars, etc. using mechanical/manual tools and removing the loose particles and dust until to reach a sound surface and removing the debris and dumping at nominated locations including lead and lift.
NON-PSR Applying two coas of DEK GUARDS aliphatic acrylate compound over a coat of primer of required colour and shade as directed by the Engineer-in-charge.
VBRUSHI
Malladi Vishnumurthy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .