Chief Engineer GSS
3rd floor north wing, DCSEM, DAE, V.S. Bhavan, Anushaktinagar, Mumbai-400094
Maintenance contract for electrical installations at Anushakti Bhavan and OYC and external electrical installations at city buildings under DCSEM, DAE in Mumbai
2022_DCSEM_727228_1
DCSE/CQD/QSC/GSS/22-23/NIT-35 dt.02.12.2022
Open Tender
Electrical Works
Item Rate
548 days
AnushaktiBhavan, OYC and city buildings under DCSEM
Please refer Tender documents
8 documents required · 8 mandatory
₹0
₹1.3 L
10 Jan 2023
6 Dec 2022
20 Dec 2022
6 Dec 2022
19 Dec 2022
6 Dec 2022
6 Dec 2022 - 13 Dec 2022
Amount
PART A : Maintenance of electrical work Anushakti Bhavan & city area.
PART B:Supply of parts. as per clause no. 6 technical specifications of work of technical bid
PART C : Job works :
Description of Work / Item(s)
Amount
Maintenance of electrical work Anushakti Bhavan & city area.
Day to day preventive & break down maintenance of electrical installations including monthly maintenance of APFC panels at AnushaktiBhavan and OYC buildings,C.S.M. Marg as per clause no.1 of technical specification of work of Technical bid and instructed by the Engineer-In-Charge.
Preventive maintenance of DBs, LT panels at Anushaktibhavan & OYC buildings as per clause no.2 technical specifications of work of technical bid and as instructed by the Engineer-in-charge.
Preventive & Cosmetic maintenance of lighting fixtures, ceiling fan, exhaust fan at Anushaktibhavan and OYC buildings on Saturday / Sunday / holyday as per clause no. 3 of and as instructed by the Engineer-in-charge. The work shall be carried out generally on Saturday, Sunday & holidays.
Break down maintenance and servicing of UPS at OYC building.
Maintenance of 10kVA three phase in / three phase out put UPS model no. LN3300 of M/s. D B Power electronics Pvt Ltd. Make with 20 nos. , 12 V, 42 AH MF batteries all as per class no. 4 technical specifications of work of technical bid.
Maintenance of 15 kVA three phase input & three phase out put UPS model no. LN3300 of M/s. D B Power electronics Pvt Ltd. Make with 20 nos. , 12 V, 65 AH MF batteries all as per class no. 4 technical specifications of work of technical bid.
Day to day preventive & break down maintenance of external electrical installations, Cosmetic maintenance of fixtures & fittings in residential buildings i.e. Zerlina Malbar hills, Purnima Malbar hills, Kenilworth pedder road, Anand Bhavan, Bhulabai Desai Road, Atomica worli, Mistry nagar Dadar, Bandra 16 th Road, Mumbai as per clause no.5 of technical specifications of work of technical bid and instructed by the Engineer-In-Charge. (in second shift of 8 hrs. from 1.0 pm to 9.30 pm)
Description of Work / Item(s)
Amount
Supply of the following parts.as per clause no. 6 technical specifications of work of technical bid (Supply of Lamp / Tubes)
400 W HPI-T lamp
250 W HPI-T PLUS TUBULAR lamp
150 W HPSV SON-T PLUS PIA lamp
70 W HPSV SON-T PLUS PIA lamp
2100Lm , 1200mm LED tube light
18W fluorescent lamps trulite
MASTER TL5 HE 28W/840 SLV/40
MASTER TL5 HE 14W/865 SLV/40
2 pin 18 W PL-C lamp similar to Philips
4 pin 18 W PL-C lamp similar to Philips
2 pin, 26 W PL-C lamp similar to Philips
4 pin, 26 W PL-C lamp similar to Philips
18W, 1200 lumen LED lamp, 3000K, similar to Philips
9 W 900Lm ( Approx.) LED lamp (coolday/warm light)
12W 1200Lm ( Approx.) LED lamp (warm light)
3.5/4/4.5/5 W E14 Clear Candle LED lamp.
2.7W 250Lm ( Approx.) LED frosted candle lamp
2.7W 230Lm ( Approx.) LED lamp
60 W E27 GLS Lamp
40/60 W GLS Lamp
10 W PL-C lamp similar to Master of M/s Philips
18 W TL-D lamp Actinic BL of M/s Philips make.(mosquito repellent )
Supply of the following parts.as per clause no. 6 technical specifications of work of technical bid (Supply of Copper ballast)
400 W HPSV/MH T lamp similar to BSN 400X261 / C8245 x 100
250 W HPSV/ MH lamp similar to BSN 250X261
150 W HPSV/MH lamp similar to BSN 150X261
70 W HPSV lamp similar to BSN 070M261
18/20 W fluorescent lamps(BTA018K261
28W TL-5 Lamp similar to EBT 128 TL5 240V
14W TL-5 Lamp similar to EBP 414 TL5
18 W PL-C lamp similar to BPL 018 X 261M/s Philips
26 W PL-C lamp similar to BPL 026 X 261M/s Philips
14W TL-5 Lamp similar to EBP 214 TL5
Supply of Igniter suitable for 70/150/250/400 W HPSV lamp
Supply of Capacitor for lighting fixtures.
1.5/2.5/4 mfd MPP type
10 mfd for 70W HPSV fixture
20 mfd for 150W HPSV fixture
33 mfd for 250W HPSV fixture
43 mfd for 400W HPSV fixture
Supply of Lamp holders for the following lamps
Holder for 150 to 400W HPSV Lamp ES cap (E40 )
Holder for 70W HPSV/125 HPMV lamp
Holder for 70 / 150W DE MH Lamp (RX7S)
Holder for 2pin CFL Lamp
Holder for 1x40WTL
Holder for 1x28WT-5 lamp
Bracket for TL side holder
Holder for 1x14 WT-5 lamp
Supply of Switches / sockets / DP switches / similar to Arteor series of M/s Legrand make
6A SP switch
6 A two way switch
6A,2+3 pin socket
6/16A socket
20 A SP Switch
120W 5 Step fan regulator
Bell push
Blanking plate
Supply of Plug top , bell, Holder
6 A 2 pin + Earth plug top (M/s. Anchor / Vinay make)
16 A 2 pin + Earth plug top (M/s. Anchor / Vinay make)
Angle / Batten Holder /ceiling rose.
Polycarbonate electronic bell
PVC square box
Supply of switches / sockets similar to series M - modular range of M/s. North West make.
6A SP switch
6 A two way switch
6A,3 pin socket
16A,SP switch
6/16A socket
6 Step fan regulator
Bell push
Blanking plate
Supply of Plastic surface boxes similar to Arteor series of M/s. Legrand make.
1/2 module
3 module
4 module
4 x 2 module
8 module
6 x 2 module
Supply of White cover plate with frame similar to Arteor series of M/s. Legrand make.
1 module white cover plate & frame
2 module white cover plate & frame
3 module white cover plate & frame
4 module white cover plate & frame
8 module white cover plate & frame
4 x 2 module white cover plate & frame
6 x 2 module white cover plate & frame
Supply of 1.1 kV grade PVC insulated copper wire of following sizes:
Supply of 1.1 kV grade PVC insulated copper wire of following sizes:
3C x 1.0 sqmm cu flexible (white in colour)
3C x 1.5sqmm cu flexible
3C x 2.5 sq. mm cu flexible
Supply of 2 pair telephone wire
Supply of Copper lugs pin type / ring type for following sizes of wires / cables.
Supply of Copper lugs heavy duty reducer type / Palm type for following sizes of wires / cables.
Supply of Copper lugs heavy duty reducer type / Palm type for following sizes of wires / cables.
21/2" Brass cable gland(240)
2" brass cable gland(150/185)
1 3/4" brass cable gland(95/120)
1 1/2" brass cable gland(70/95)
1.3/8" Brass cable gland(50)
1¼" Brass cable gland(25/35)
1 1/8" Brass cable gland(16)
1" Brass cable gland(2.5/10)
7/8" Brass cable gland(4/6)
3/4" Brass cable gland(1.5/2.5/4)
1/2" Brass cable gland(1.5/2.5)
Supply of MCB / MCCB / ELCB/RCBO
6-32A,SP,MCB C curve
6-32A,DP,MCB C curve
40-63 , DP,MCB C curve
6-32A,4P,MCB C curve
6-32A,TP,MCB C curve
40-63A,4P,MCB C curve
40-63A,TP,MCB C curve
100A, DP, MCB C curve
100A , 4 pole MCB C curve
25 A, 2 pole 30 mA RCCB
40 A, 2 pole 30 mA RCCB
63 A, 2 pole 30 mA RCCB
25 A, 4 pole 30 mA RCCB
40 A, 4 pole 30 mA RCCB
63 A, 4 pole 30 mA RCCB
32A, 4 pole 30 mA RCBO 7/8 Module
40A, 4 pole 30 mA RCBO 7/8 Module
63A, 4 pole 30 mA RCBO 7/8 Module
63A, 4 pole 300 mA RCBO 7/8 Module
Metal one way enclosure for DP/FP MCB
Metal one way enclosure for FP RCBO
25A, DP, 30 mA RCBO 4 Module
32A, DP, 30 mA RCBO 4 Module
40A, DP, 30 mA RCBO 4 Module
63A, DP, 30 mA RCBO 4 Module
20A SP 2P+EMetal clad plug and socket
125 A MCCB 16kA BC
160 A MCCB 16kA BC
200 A MCCB 16kA BC
40A DP change over switch
63 A 4P change over switch
Supply of HRC fuse link / fuse base ( moulded type)
Upto 16A HRC fuse link similar to HG type F1 size of M/s L&T
32A HRC fuse link similar to HQ type A2 size of M/s L&T
63A HRC fuse link similar to HQ type A3 size of M/s L&T
32A Bakelite moulded fuse base similar to HD 32B make L&T
32A Bakelite moulded fuse base similar to HD 32H make L&T
32A Bakelite moulded fuse base similar to HK 32B make L&T
32A Bakelite moulded fuse base similar to HK 32H make L&T
63A Bakelite moulded fuse base similar to HK 63H make L&T
100A HRC fuse link similar to HQ type B1 size of M/s L&T
200A HRC fuse link similar to HQ type B2 size of M/s L&T
125A HN type HRC fuse link
630A HN type HRC fuse link
Supply of 12" dia. white PVC dome for pole light
Supply of Bakelite sheet 3 mm thick
Supply of SMC / FRP boxes, connector s, etc.
IP66 halogen free weather proof cable junction box similar to catalog no. KF2500 B of M/s. Hensel make with 4 ways terminal block & 6 A SP MCB on DIN channel , 2 mm thick GI gland plate of suitable size and openable plain cover etc.
IP66 halogen free weather proof cable junction box of 104 x 404 x 70 mm in size approx. similar to catalog no. KF0404 B of M/s. Hensel make with 3 / 4 ways terminal block , 2 mm GI gland plate of suitable size and openable plain cover etc.
Bakelite connector 16A, 4 ways, 250 volts.
Bakelite connector 32A, 4 ways, 415 volts.
Copper neutral link 6 ways suitable for 16 sq. mm. cable connection.
Supply of Timer box accessories such as contactors, indication lamps, push button, timer, toggle switch etc.
ML-1.5 of L&T(SS91851) / MNX - A2
Analogue daily timer, M/s. GIC make.
Astro timer
ON/OFF push buttons
indicating lamps
16 A, 240 Volts three position toggle switch.
Panel lock
Supply of GI fixing fasteners
Coach Screw 3/8” x 3” long
Anchor fastener 3/8”x3” long
Anchor Fastener1/4”x 2” long
Supply of Telephone instrument similar to model no. B 11 of M/s Beetal make.
Supply of following spares of APFC panel / Capacitor banks
25kVAR Heavy duty Box type
50kVAR Heavy duty Box type
10 kVAR Heavy duty Box type
Timer
Capacitor duty contactor for 25 KVAR with side add on block (1 NO + 1NC)
Capacitor duty contactor for 50 kVAR with side add on block ( 1NO+ 1 NC)
Capacitor duty contactor for 10 kVAR with side add on block ( 1NO+ 1 NC)
Automatic power factor control relay stage 8
Supply of PVC casing capping / conduit of following sizes with nylon plug and wood screw ( 3 set per meter ).
PVC casing – capping of 25 x 16mm.
PVC casing – capping of 38 x 16mm.
FRPP flexible conduit 25mm
FRPP flexible conduit 36mm
HMS PVC conduit 25 mm socketed type with spacer saddles (3 set per meter).
HMS PVC conduit 36mm socketed type with spacer saddles (3 set per meter) for HMS conduits, etc.
Supply of MS & GI materials
50 mm dia. G.I. pipe, class B with necessary accessories like GI clamp, wood screws, nylon plug etc.
25 X 6 mm Hot Dipped GI strip with space & saddles 2nos
8/10SWG GI wires.
Supply of following LED light fixtures of approved make
2 ft. surface mounted LED batten fixture with min efficacy 100lm/W, min.lumen output 1000 Lm , CCT 5700 /6500/6500K, min.CRI 80, min. P.f. 0.9, min. I.P 20, THD < 10%, Housing Extruded Aluminium.
4 ft. surface mounted LED batten with LED tube, min efficacy 100lm/W, min.lumen output 2600 Lm , CCT 5700 /6500/6500K, min.CRI 80, min. P.f 0.9, min. I.P 20, THD < 10%, Housing Extruded Aluminium
4 ft. surface mounted LED batten fixture with, min efficacy 100lm/W, min.lumen output 3200 Lm , CCT 5700 /6500/6500K, min.CRI 80, min. P.f 0.9, min. I.P 20, THD < 10%, Housing Extruded Aluminium
LED bulkhead lighting fixture with minimum efficacy of 105 lm/watt, min. lumen out put 700 lumen, cool white colour temperature with diffused polycarbonate cover & pressure die cast housing having at least IP65 & IK08 protection etc.
LED post top light Fixture having a minimum efficacy of 75 lm/watts and a minimum lumen output 4200 lumens, CCT :- 4000 K, min.CRI :- 70, min. P.f :- 0.9, min. I.P :- 66, IK 08, THD < 20%, Housing:- Pressure dia cast Aluminium
STREET LIGHT LED light Fixtures having a minimum efficacy of 130 lm/watts and a minimum output of 11000 lumens, with cool white/ neutral white colour temperature & pressure die cast Aluminium housing having IP66 & IK08 protection etc.
floodlight LED fixture with min efficacy 110 lm/W, min.lumen output 11000Lm , CCT 5700 /6500 K, min.CRI 70, min. P.f 0.95, min. I.P 66, Housing:- Pressure dia cast Aluminium
floodlight LED fixture with min efficacy 100 lm/W, min.lumen output 6500Lm , CCT 5700 /6500 K, min.CRI 70, min. P.f 0.95, min. I.P 66, Housing Pressure dia cast Aluminium
Lowboy LED fixture of min efficacy 100 lm/W, min.lumen output 6000 Lm , CCT 5700 /6500 K, min.CRI 80, min. P.f 0.95, min. I.P 65, Beam angle 60 deg., Housing Extruded Aluminium
Surface mounting weather proof(IP65) LED Tube light fixture suitable for single T8 TLED Lamp.
Supply of following Fans
Exhaust fan similar to Ventil Air DB 230 mm of M/s. hevells make complete with supply cord and 3 pin top.
300 sweep wall fan similar to model swing of m/s. Havells
300 mm sweep exhaust fan similar to model Turbojet force of m/s. Havells
supply of 1.1 kV grade PVC / XLPE insulated, inner sheath PVC tapped extruded outer sheath PVC, confirming to relevant IS standard with upto date amendments cable of following sizes with heavy gauge GI spacer and saddle & suitable size of wood screws, nylon plug etc. ( 3 sets per meter )
3CX 1.5 sq. mm PVCA Copper conductor power cable
3CX 2.5 sq. mm PVCA Copper conductor power cable
3CX 6 sq. mm PVCA Copper conductor power cable
Supply of Raw Salt
Description of Work / Item(s)
Amount
Dressing of armoured cables of sizes up to 3/4 C x 25 sq. mm. Complete with heavy gauge GI spacer and saddle, on wall /column / slab / shaft etc. with suitable size of wood screws, nylon plug etc. including removal of existing rusted old saddle & spacers. Spacer and saddles shall be fixed max. 3 nos. in one meter of cable length all as required and as instructed by Engineer-In-Charge.
Earth Excavation
Excavation in asphalt road/ concrete/hard rock: Cutting of hard rock/asphalt road / concrete flooring /drain, refilling, refinishing as per original, stacking of rocks, consolidation, disposal of excess earth within the radius of 3000 M as required and directed by Engineer in-charge.
Repair & servicing of existing ceiling fan / exhaust fan / wall mounting fan / pedestal fan of different sizes including replacement of ball bearing, bush as required & instructed by E-I-C.
Ceiling fan ( 900 mm / 1200 mm / 1400 mm sweep)
Exhaust fan 300 mm to 450 mm sweep / wall mounted fan / pedestal fan.
Rewinding of above fans
Cleaning & removal of dust by sand paper and painting the external surface of street light poles & bollard by applying one coat of red oxide and two coats of bituminous paint etc. as required including numbering the poles with black paint etc. as per the instructions of Engineer-in-charge. scope also includes the painting of foundation of street light pole.
Street light pole up to 9 Meter.
Tennis court lighting M. S Pole with bracket
Bollard
Brackets support
Breaking of existing foundation of post top lantern fittings pole & providing new 1:3:6 PCC foundation complete with FRP / Syntex make junction box of size 200 x200x125 mm 15 A 4 way terminal block and 6A SP MCB, on din channel, 2 mm thick GI gland plate of suitable size etc. complete with all as required & instructions of Engineer-In-Charge.
Supply, installation, testing and commissioning of earth station with heavy dipped GI earth plates electrode 600 x 600 x 6.0 mm in size at the depth of 2.5 m below ground level (bottom of Plate) confirming to IS 3043 complete with all required materials like coke / charcoal, salt, G.I nut bolts, washers, 19 mm dia GI pipe (B class), 150 mm thick concrete wall chamber of suitable size duly plastered, heavy duty (minimum 6 mm thick) M.S chequered plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements, complete with funnels, GI test links (50 x 6 mm), two runs of 25 x 6mm G.I strips for connecting G.I plate & test link etc. including excavation of ground in all types of soils, refilling & removal of excess earth within a radius of 500 m etc. all as required as per the drawing specifications & instructed by Engineer-in-charge. Note:- The chamber cover & frame shall be got approved by Department & painted with two coats of red oxide & one coat of enamel paint.
Repair of earth pit chamber by replacing the existing rusted/ damaged M.S. chequered plate, angle iron frame work with 150 mm thick or suitable size concrete wall chamber duly plastered, heavy duty (minimum 6 mm thick) M.S chequered plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements etc., as per the instructions of Engineer-in-charge
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .