| 1 | Qualified Make: MAHINDRA-KEW
Model: MAHINDRA & MAHINDRA LTD MM 3335 TC GM C2 BASEMENT SECTOR 17C SECTOR 17C CHANDIGARH CHANDIGARH 160017 | CHANDIGARH | CHANDIGARH | 160017 | Make: MAHINDRA-KEW
Model: MAHINDRA & MAHINDRA LTD MM 3335 TC GM C2 | - | - | Qualified |
| 2 | L1₹3.9 LDisqualified Make: Koel Green Electro
Model: KOEL GREEN KG1-20WS1 WITH PART NO. 318168-1212-B | Make: Koel Green Electro
Model: KOEL GREEN KG1-20WS1 WITH PART NO. 318168-1212-B | ₹3.9 L | L1 | Disqualified |
| 3 | Disqualified Make: Koel Green Elmech
Model: KOEL GREEN KG1-20WS1 WITH PART NO. 318168-1212B 1402 CHIRANJIV TOWERS 43 NEHRU PLACE NEHRU PLACE DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Koel Green Elmech
Model: KOEL GREEN KG1-20WS1 WITH PART NO. 318168-1212B | - | - | Disqualified |
| 4 | Disqualified Make: MAHINDRA POWEROL
Model: Mahendra 20 KVA | Make: MAHINDRA POWEROL
Model: Mahendra 20 KVA | - | - | Disqualified |
| 5 | Disqualified Make: Greaves Power
Model: GREAVES COTTON & GPWII-PII-20 | Make: Greaves Power
Model: GREAVES COTTON & GPWII-PII-20 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 Aug 2018, 7:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 20 (or higher) No of Phase - Single phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No
if applicable - * Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Electronic Mechanical
Electronic (or higher) Class of governer A1 A0
A1
A2 (or higher) Number of cylinders 3 * 1/4 (nos) No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 20 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 86.51 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel AMF Manual
AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 (or higher) Thickness of Foam 25 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * 2/4 No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Any applicable numeric value Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar Rai 313332
Deogarh Road Amet 1 15
493011
GEM/2018/B/69735
diesel generators- DG Sets
15 days
Rajasthan; Rajsamand
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 20 (or higher) No of Phase - Single phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * BIS license No | - | - | - |
| if applicable - * Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Electronic Mechanical | - | - | - |
| Electronic (or higher) Class of governer A1 A0 | - | - | - |
| A1 | - | - | - |
| A2 (or higher) Number of cylinders 3 * 1/4 (nos) No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 20 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 86.51 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel AMF Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 (or higher) Thickness of Foam 25 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * 2/4 No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Any applicable numeric value Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Narendra Kumar Rai 313332 | - | - | - |
| Deogarh Road Amet 1 15 | - | - | - |
Exempted
21 Aug 2018
18 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_493011.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid