| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹19.2 L+₹3.0 L (18.7%)Rejected-Finance NO 7A MULLAI NAGAR MAIN RD WEST TAMBARAM CHENNAI 600 045 | CHENGALPATTU | TAMIL NADU | 600045 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹21.0 L+₹4.8 L (30.0%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹21.7 L
EMD Value
₹43,400
Closing Date
18 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
PROVN OF RAIN SHELTERS, ADDN/ ALTN TO RAMP FOR FOUR WHEELERS, PROVN OF AUTOMATION OF SHALLOW WELL PUMPING ETC AT AIRFORCE STATION TAMBARAM
2023_MES_615016_1
GE(AF)/TBM/8657/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹43,400
Yes
13 Oct 2023
22 Aug 2023
20 Sept 2023
22 Aug 2023
18 Sept 2023
6 Sept 2023
23 Aug 2023 - 29 Aug 2023
Amount
Excavation in post holes (or similar holes) in hard/dense soil each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc 50 m and making good surface all as specified and directed.
Surface excavation not exc.30 cm deep and averaging 15cm deep and getting out in hard/ dense soil , complete all as specified and directed.
M&L for Plain cement concrete Type C2, 1:3:6 using 40 mm graded stone coarse aggregate in foundations,filling and mass concrete all as specified and as directed
S&F steel work in tubular trusses i.e. Truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and as directed
Excavating in trenches in hard dense soil not exc 1.5 m wide and not exc 1.5 m in depth for foundation, etc. and getting out complete specified and as directed
M&L Mild steel plates , channels section, square or notched forming holes with riveted, bolted or welded attachments etc complete all as specified and directed.
M&L Mild steel works as in bands, hold fasts, plain angle cleats for securing purlins and rafters, plate washers and similar small articles etc complete all as specified and directed.
S&F Mild steel work as in wind ties for roof including securing bolts etc and similar work conforming to Fe-290 Gde E-165
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as specified.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L for hardcore of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed
M&L Plain cement concrete 1:4:8 type D 2 using 40mm graded stone aggregate , 100mm thickness, as in sub base, plinth protection etc., complete all as specified and as directed
M&L Plain cement concrete 1:2:4 type B 1 using 20mm graded stone aggregate , 100mm thickness, as in floor ing finished the surfaces smooth without using extra cement etc., complete all as specified and as directed
Forming contraction (dummy) joint 65mm deep x 10mm wide duly sealed with sealing compound, Grade ‘A’complete all as specified and as directed
Pre-cast cement concrete block masonry of with solid blocks PCC 1:3:6 set in cement mortar 1:6 , exc. 10 cm in width all as specified and as directed
M & L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete specified and as directed
Removing excavated materialn exc 50mtr but not exc 250mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete specified and as directed
Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 and finished the surface even and smooth complete all as specified and as directed
Preparing newly plastered surface and applying two coat of cement base paint over one coat of primer complete all as specified and as directed
M & L for providing plain cement concrete type B1 1:2:4 (20mm graded stone aggregate) as in kerbs, mud stops, rounded or chambered on edges all as specified and as directed
M & L for treating/painting small articles such as cleats, barckets, hooks, knobs, fasteners and other similar articles etc with black paint or tar all as specified and as directed
Demolition of reinforced cement concrete as in roof, floors beams, staircase, landings, chajjas and similar suspended work all as specified and as directed
Demolition of brickwork or stone/bhoulder masonry built in cement or cement lime mortar including all quions, arches, pillars etc but excluding ashlar afcing dressed stonework and precast concrete articles all as specified and as directed
Demolition of cement concrete of any description and in any postion not otherwise specifically provided for all as specified and as directed
Excavation over areas exc. 1.5m wide and not exc.1.5m deep and getting out in hard/ dense soil complete all as specifed and directed
M&L for precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:4, type C-1 1:3:6 (20 mm graded aggregate) complete all as specifed and directed
M&L PCC 1:3:6 type B1 (20mm graded stone aggregates) as in coping to brick wall, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specifed and directed
M & L for Rendering 15 mm thick in CM 1:4 for finishing the surface even and smooth without using extra cement complete all as specifed and directed
Use and waste of from work to suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200mm thick for rough finished surfaces all as specifed and directed
M & L RCC 1:1.5:3, nominal mix as in reinforced cement concrete to slab supported on walls, beams and columns in floors, roofs, landings, balconies, canpoies, deck slabs and in shelves and the like all as specifed and directed
M & L for plain cement concrete type C2 1:3:6 using 40mm grade stone aggrgates as in surface channels and drains all as specified and directed.
Extra for forming fair finished drain or channel 20 cm inner girth in cement concrete,using extra cement,including form, moulds, mitred/ stopped ends etc complete all as specified and directed.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for design,Fabrication,install,commissioning and testing of LT cubical motor control panel board of suitable size as directed, three phase 4-wire systems, out door type, made out of CRCA sheet 3.0 mm thick, powder coated, with locking arrangements,mounted on 50x50x6mm angle iron frame complete suitable to accommodate and including the following:- (a) Automatic water level controller with LED indication for well water pumping system with intelligence features like level indication, auto/manual mode operation with By-pass options,dry-run protection, voltage surge protection,voltage level indications and fill options, in built power ON-OFF relay with three phase,440V AC supply,30 Amps power capacity suitable for pumps used for industrial purpose all as directed.(b) Six core multi stranded copper conductor 1.0 Sqmm from well to panel box-50mtr. Note : Additional Six core multi stranded copper conductor 1.0 Sqmm length required more than 50 Mtr shall be measured and paid separately under relevant items.
Supply and fix Water flow meter of size 100mm dia woltman type with removal mechanism,flange ends, magnetic drive,confirming standard ISO 4064,class B, with CI dirt box including jointing materials such as nuts, bolts washers and 3mm rubber gasket 02 Nos complete all as specified and directed. -01 Nos. Make: Apollo or equivallent as approved.
Supply and fix multi stranded copper conductor 1.0 Sqmm,6 core from well to panel box all as specified and directed.
Labour only for filling of excavated soil upto a depth of 23 cm after riddiling the excavated soil for cushioning of cable all as specified and directed
Supply and laying well brunt brick old size class B laid dry flat for protection over the cable, width equal to the length of cable complete all as specified.
Supply and Laying LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor size 35 Sqmm 3.5Core all as specified and as directed.
M & L for Sub main wiring complete with four runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth contuinuity conductor, drawn through and including suitable size of non metallic rigid PVC conduits and conduit accessories surface for taking connection from existing panels all as specified and as directed. NOTE :- 4 runs of 4.0 sqmm cable, 2run of 4 sqmm copper conductor cable and two run of PVC conduit shall be measured as one length/running metre.
Supply and connect flat PVC insulated, 3 core, 4 Sqmm multistrand copper cable from submersible pump set to panel testing and commissioning etc., complete all as specified and directed
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of panels, PCC blocks and platform etc.complete all as specified and directed
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to GI earth strip of size 32 X 6 mm by means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 100mm centre to centre with suitable handle, watering pipe 20mm dia medium grade pipe with funnel and 40mm dia light grade as protection pipe, charcoal, salt etc connected to earthing test point all as specified including testing and commissioning on completion all as specified and as directed.
Supply install and Testing & commissioning of Servo voltage stabilizer of capacity 24 KVA ,single phase Input voltage range 170V to 270V AC ,Output voltage 230 V,50Hz with wide Range Double booster all as specified and directed.
ragavbuilders
kcs builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .