Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹15.5 L+₹4.3 L (37.9%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹20.3 L+₹9.0 L (80.3%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹21.3 L+₹10.1 L (89.5%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹24.0 L+₹12.7 L (113.3%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ SRINATH PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/ MAINT OF SUMMER AND COOLING APPLIANCES AT COD AREA UNDER GE (I) KANPUR
2023_MES_592187_1
GE(I)/KAN/T-14 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KANPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE(I) KANPUR
₹60,000
Yes
28 Jul 2023
29 Apr 2023
31 May 2023
29 Apr 2023
25 May 2023
11 May 2023
Amount
Disconnecting electrically, taking down, dismantling, opening the cover of AC and taking out and servicing of window type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oil and other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete all as specified and directed by Engr in charge.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window AC of 1.5 / 2 Ton capacity including necessary welding with existing refrigerant pipe, charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately if required under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate. (iii) Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor.
S&F repair of cooling coil of window type AC any cap up to 2 ton all as spfd.
S&F in repair of front grill of window AC suitable for 1.5/2 ton cap as per sample all as spfd and directed.
S&F in repair of rotary type sealed compressor of window AC 1.5/2 Ton cap as per sample all as spfd and directed.
S&F in repair of Air blower moter as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase as per sample all as spfd and directed.
S&F in repair of starting capacitor suitable for window/split AC of rating 45 - 100 Mfd as per sample all as spfd and directed.
S&F in repair of starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton as per sample.
S&F in repair of thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity all as spfd.
S&F in repair of condenser fan blade suitable for window/split type AC of any make & capacity all as spfd and direceted.
M&L for minor denting work to window type air conditioners of 1.5 / 2 Ton capacity including applying spary painting with a coat of synthetic enamel paint of requried shade complete all as specified and directed by the engineer -in -charge.
Disconnecting electrically and opening the cover of split AC 1.5/2 ton cap inner/outer unit and servicing incluiding cleaning / removing all dust / mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete including servicing, oiling, greasing complete air conditioner and checking of electrical connection and testing complete all as directed by Engineer-in-Charge.
Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the Split type AC of 1.5 / 2 Ton capacity and fixing only new spares as per model / capacity including necessary welding with existing refrigerant pipe, charging refrigerant gas and testing complete all as specified and directed. Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay and refrigerant gas shall be measured and paid separately under respective item of Schedule ‘A’. (ii) If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.
S&F in repair of sealed compressor, rotary type, of any make as per sample suitable for split type AC of 1.5/2 Ton capacity all as spfd and directed.
S&F in repair of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type all as spfd and directed.
S&F in repair of discharge grill of outdoor unit of any size and type for split AC’s all as spfd and directed.
Supply and fixing in repair of defective remote control hand set with "AAA" batteries for window/split type AC's, of any model / make complete all as specified and directed.
Supply and fixing in repair of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed.
Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed.
Supply and fixing of annealed copper tube as per existing and site requirement complete all as specified and directed.
Supply and fixing of condenser / cooling coil for air conditioner of suitable size complete as per site requirement and as directed.
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remort all as spfd and directed.
M&L for fixing/installation of split AC inner/outer or both unit as received from item No 59 with all accessories and making all coonection of copper tubing/drain and electrically and testing on completion all as spfd and directed. Note : Refrigrant and other connecting items i.e copper tube/ drain pipe will be measured and paid seperately under respective item if required.
supply and fixing in repair of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed.
supply and fixing in repair of foamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed.
S&F in repair of Main control circuit (PCB) as per sample for window/split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of Main control circuit (PCB) as per sample for window/split type AC's, of any model / make complete all as specified and directed.
S&F in replacement of Sensor as per sample for window/split type AC's, of any model / make complete all as specified and directed.
S&F in repair of PVC flexible drain pipe 15mm to 25mm dia clamped with suitable PVC clamps fasten by SS nails on one end all as spfd and directed.
M & L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor's workshop including any welding / repair work reqd at site complete all as specified and as directed.
Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit medium grade of size 20/25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends for drain of AC all as spfd and directed.
Supply only refrigerant R-22/R134a/R410 environment friendly refrigerants as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and as directed. Note : Refrigerant gas shall be supplied and paid separately under item No 33 herein after
Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 2 to 5 kVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc all as spfd and directed. Note : Spare parts will be measured and paid seperately under respactive items.
Supply and fixing in repair of Main relay of voltage stabilizer 3 to 5 kVA as per sample.
Supply and fixing in repair of Main control circuit (PCB) of voltage stabilizer 3 to 5 kVA as per sample.
Supply and fixing in repair of replacement of sensor transformer of voltage stabilizer 3 to 5 kVA as per sample.
Supply and fixing in repair of voltmeter of voltage stabilizer 3 to 5 kVA as per sample. .
Supply and fixing in repair of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 kVA as per sample.
Taking out old burnt winding of transformer and re-winding the same with super enameled copper winding wire (existing size) for 3 to 5 kVA voltage stabilizers including all necessary insulating material and testing complete.
M & L repair for painting of voltage stabilizers with a coat of synthetic enamel paint of existing shade after proper cleaning and scraping out old painted surfaces and writing GE (I) Kanpur on voltage stabilizers in block letters with white synthetic enameled paint complete all as specified and directed by the Engineer-in-Charge.
M & L for Writing SM / MES No. of Summer cooling appliances including Water coolers, desert coolers, refrigerators and Air Conditioners with synthetic enamel paint of Make Asian paints Ltd. Or Stickers equivalent of approved color complete all as specified and directed by Engr-in-Charge.
M & L in repair for filling up complete cavity nearby indoor unit through the wall completey vermin/rat proof from outside using PU foam spray all purpose cosmos MRO preferabbly off white in color & 750 mm bottle complete all as directed.
M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size,dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame of sjuitable size fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including rating copper bus bar not less than 40X10 mm suitable for 600 Amps for 3 phase 4 wire mounted on epoxy based post insulators with suitable size of CTs, LED indicator lamp set type RYB (indicator lamps should display colour of phase as well as phase volatge complete) of make AE/Legrand/L&T, complete internal wiring with suitable size of copper conductor PVC insulated and sheathed cable front and rear openable double door with locking arrangement, angle iron frame made out from suitable size and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as required at site or directed. Make : As per approved by CELZ Note: All MCCBs should have adjustble thermal and fixed magnetic setting and Ics will be 100%Icu INCOMMER (i) MCCB 3 Phase, 4 Pole 400 Amps,35/36kA rupturing cap,415 volts 50 Hz AC supply - 01 Nos (ii) Digital VIF meter -01 Nos Make :AE/L&T/ABB (iv) Phase indicating lamp RYB with indicating voltage in digital LED format ( set of three) - 01 Set OUTGOING (i) MCCB 3 Phase, 4 Pole,160 Amps,25 kA,415 volts 50 HZ AC supply - 02 Nos (ii) MCCB 3 Phase, 4 Pole,100 Amps,25 kA,415 volts 50 HZ AC supply - 01 Nos (iii) MCCB 3 Phase, 4 Pole,63 Amps,25 kA,415 volts 50 HZ AC supply - 02 Nos
M & L repair for water leakage from indoor unit any type & any make, height upto 15 ft complete all as specified and all as directed.
Repair, maint and making the continuity of electric supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigrator, ACs etc. including providioning of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) any other accessories found unserviceable shall be replaced & paid seprately under respective items of this Sch. (ii) Contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectifing the defact on next day morning (iii) Complaint slip book, registers as per sample will be provided by the contractor.
Disconnecting electrically, taking down existing ceiling/exhasut fan any type and capacity with due care, dismantlin blades and removing for repair with all accessories all as spfd and directed.
Assembling the fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired complete with all accessories all as spfd and directed.
Strip opening of ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified. Note :- 1. Repairs will be measured and paid separately under respective items.
Rewinding of ceiling fan motor 1200/1400 mm sweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, greasing ,connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire complete and all as specified.
S&F in repair fan capacitor AC 440 volts 4 mfd 50HZ complete and all as specified. Make : Jimcap/Epcos/Havells
All as per srl item No 6 here-in-before but 2.5 mfd and complete all as specified and directed.
All as per srl item No 6 here-in-before but 3.15 mfd and complete all as specified and directed.
S&F in repair of gun metal bush suitable for any size / model / type of fans complete all as specified & directed.
S&F in repair alignment grinding to shaft, remetalling & finishing all as required.
S&F in repair ceiling fan shaft of standard size including taking out old shaft, complete and all as specified.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge. Make : Havells/Anchor/Indoasian
Strip opening of exhaust fan/air circulator/table fan/Pedestal/wall fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified.
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal/wall mounted fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified.
S&F in repair of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete and all as specified Make : SKF/NBC/ABC.
S&F in repair of ball bearing for exhaust fan/pedestal fan/air circulator/table/wall fan upto 450mm sweep complete and all as specified Make : SKF/NBC/ABC.
Cleaning thoroughly ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
Cleaning thoroughly exhaust/wall/podestal fan 256 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed by Engineer-in-Charge
S&F in repair of fan blade set steel heavy duty suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
S&F in repair of fan blade set plastic suitable for exhaust/ pedestal/air circulator fan 250 to 450 mm sweep, complete (as per sample) and all as directed by Engineer-in-Charge.
S&F in replacement of fan blade set steel 1200/1400mm sweep complete (as per sample) and all as directed by Engineer-in-Charge suitable for ceiling fan all as required at site.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin complete all as per sample of size 45 Cm long.
All as per item No 22 but of size 1 Mtrs long and complete all as specified and directed.
All as per item No 22 but of size 1.5 Mtrs long and complete all as specified and directed.
All as per item No 22 but of size 2 Mtrs long and complete all as specified and directed.
All as per item No 22 but of size 3 Mtrs long and complete all as specified and directed.
Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep for servicing, strip opening of fan including servicing, cleaning, oiling and greasing complete at site. Re-assembling and refixing to the same/other location. Testing complete after servicing and fixing for smooth and noise free operation.
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed by Engr-in-Charge.
S&F in repair for 40 mm bore galvanised iron tubing medium grade fixed to walls for hanging the fan complete all as specified and directed.
S&F in repair for 50 mm bore galvanised iron tubing medium grade fixed to walls for hanging the fan complete all as specified and directed.
S&F of hook for hanging of fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers all as per sample complete all as specified & directed.
M & L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells/Plaza.
All as per item No 32 but copper cable of size 1.5 Sqmm.
All as per item No 32 but copper cable of size 2.5 Sqmm.
M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one MCB 25 Amps, 240 Volts.
S&F in repair of plug top 15 Amps all as spfd and directed. Make : Cona/Anchor/Havells
S&F repair of ceiling fan clamps for fixing with fan rod incd nut, bolt, lock pin, rubber real complete all as specified & directed.
Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the complete condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed.
Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrs for repair all as spfd and directed.
M&L repair for fixing/installation of water cooler any type of cap 40/ 80/ 150 ltrs and making all electrical/water connection and testing all as spfd and directed
S&F repair in replacement of sealed compressor as per sample suitable for water cooler of capacity up to 40 / 80/ 150 Ltrs as per sample.
S&F repair in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd as per sample for water cooler.
S&F repair in replacement of Running capacitor 10-30 Mfd as per sample for water coller/ window ac/ split ac/refrigerator.
S&F repair in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs as per sample.
S&F repair in replacement of Starting relay of water cooler as per compressor requirement.
S&F repair in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement.
S&F repair in replacement of Over load protector of water cooler as per sample suitable for water coolers.
S&F in repair of PVC flexible pipe transparent 15 / 20 mm dia (as per sample) for water cooler.
S&F in replacement of Brass chromium plated Push cock heavy duty universal type, suitable for water cooler of capacity up to 150 ltrs.
S&F in repair of PVC float valve 15 / 20 mm dia with rod & ball for water cooler. Make: Prayag or equivalent.
S&F in repair of Liquid line filter one way / two way for water cooler.
Supply and fixing in repair of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed.
S & F in repair of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed.
M & L repair for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed.
M & L repair for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed.
M/s A S Electrical
PAWAN COOL CORPORATION
santosh electronics
LARSEN AIR CONDITIONING & REFRIGERATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .