Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
21 Feb 2020, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
SPECIAL REPAIRS OF AUTOMATIC POWER FACTOR CORRECTION PANEL AND CERTAIN MINOR WORKS AT LGJ MIL STN
2020_MES_313791_2
8930-28/19-20
Open Tender
Civil Works
Item Rate
120 days
GE Lalgarh Jattan
Class E Cat (b)(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹20,000
Yes
11 Mar 2020
29 Jan 2020
24 Feb 2020
29 Jan 2020
21 Feb 2020
13 Feb 2020
Amount
Servicing, repair, maintenance and caliberation of automatic power factor control (APFC) panel of capacity 20 KVAR to 100 KVAR balance or un balance load, any size, specification, location and type installed consisting of auto controller relay, contractors, capacitors, switch controls feses reactors etc. inspection and detection of fault, worn out spare parts, accessories, wires, MCCB's Bus bar repair/replacement of defective circuits minor parts of wiring lugs relays fuses, mcb, cooling fan, discharge resistors etc. replacement of defective worn out major parts like capacitors, capacitor (PF) controller relay,reactor,measuring instruments,indicating lamp holders,push buttens,CT coils.power analyser etc. making panel serviceable in order to maintain PF unity/0.99 lagging complete all as specified and directed by Engineer-in-charge. NOTE :- (a) Cost of minor spare parts and accessories, wire, lugs, lamps, fuse, nut bolt, washers, locks, cable duct, tray and cover shall be deemed to be inclusive in quoted rates. (b) Major parts shall be measured and paid separately in respective items of BOQ 1 to24. (c) Contractor will ensure visit of technician once in a fortnight to all panels in scope or on defects, beakdown to maitain the same all the time serviceable and PF 0.99 lagging till completion of work and defect liability period.
Servicing, repair, maintenance and caliberation of automatic power factor control (APFC) panel of capacity 101 KVAr to 200 KVAr balance or unbalance load, any size, specification, location and type installed consisting of auto power factor controller relay, contractors, capacitors, switch controls fuses reactors etc. inspection and detection of fault, worn out spare parts, accessories, wires, MCCBs, bus bar repair/replacement of defective circuits minor parts of wiring lugs relays fuses, MCB, cooling fan, discharge resistors etc. replacement of defective worn out major parts like capacitors, automatic (PF) controller relay, reactor, measuring instruments, indicating lamp holders, push buttons, CT coils, power analyser etc making panel serviceable in order to maintain PF unity/0.99 lagging complete all as specified and directed by Engineer-in-charge. NOTE:- (a) Cost of minor spare parts and accessories, wire, lugs, lamps, fuse, nut bolt, washers, locks, cable duct, tray and cover shall be deemed to be inclusive in quoted rates. (b) Major parts shall be measured and paid separately in respective items of BOQ 1 to 24. (c) Contractor will ensure visit of technician once in a fortnight to all panels in scope or on defects,beakdown to maitain the same all the time serviceable and PF 0.99 lagging. till completion of work and defect liability period.
Supply only Power factor standard duty cylindrical capacitor capacitor resine filled self healing MPP type medium duty, cylindrical / box type, star/delta connected 440 volts 50 Hz of rating 2 KVAR to 25 KVAR as per site requirement as specified and directed by Engineer-in-charge. Make : L&T, Epcos, Crompton, Schneider, Havells.
Supply only Load sensing CT coil indoor tape insulated ring type of rating as required to sence the corrected P F primary current rating abt 120 percent of max load current and secondry current rating 5 amp, class not more than 1.0 and VA burden 10-15 VA any ID, OD and height as specified and directed by Engineer-in-charge. Make : AE, C & S, Schneider, Havells, HPL.
Supply only Capacitor switching duty contractor, 3 phase 440 VAC,having additional auxillary contacts with current limiting resisters up to10 KVAR Capacity Duty Contactor 1NO 1NC 240 VAC coil voltage as specified and directed by Engineer-in-charge. Make : L&T Cat part No. CS96156 or similar in Epcos, Schneider, Havells, HPL.
Supply only Capacitor switching duty contractor, 3 phase 440 VAC,having additional auxillary contacts with current limiting resisters above10 KVAR up to 15 KVAR Capacity Duty Contactor 1NO 1NC 240 VAC coil voltage as specified and directed by Engineer-in-charge. Make : L&T Cat part No. CS90019 or similar in, Epcos, Schneider, Havells, HPL.
Supply only Capacitor switching duty contractor, 3 phase 440 VAC,having additional auxillary contacts with current limiting resisters above 15 KVAR up to 25 KVAR Capacity Duty Contactor 1NO 1NC 240 VAC coil voltage complete all as specified and directed by Engineer-in-charge. Make : L&T Cat part No. CS96322 or similar in, Epcos, Schneider, Havells, HPL.
Supply only power factor controller intelligent relay single CT sensing 8 steps, power requirement 3 VA and VA burden rating 15 VA, 230 VAC to automatically switch on the required amount of capacitors, complete all as specified and directed by Engineer-in-charge. Make : L&T, Epcos, Schneider, Havells, HPL.
Supply only MCCB 3 phase 415 volts, 3 pole, rating 63/100 amps, 15/16/18 KA, Ics=100% Icu, adjustable overload setting and thermal release 80 to 100 %, complete duly fixed with fasteners and spreaders , copper / aluminium lugs / terminals with minor modification in existing LT panels any type and size all as specified and directed by Engineer-in-charge. Make : L&T, Legrand, Schneider, Havells, HPL.
,---Ditto--- All as per Serial item No. 9 above, but rating 160 amps, 36KA, thermal release 125-160% as specified and directed by Engineer-in-charge.
,---Ditto--- All as per Serial item No. 9 above, but rating 200 amps ,36KA,thermal release 160-200% as specified and directed by Engineer-in-charge.
,---Ditto--- All as per Serial item No. 9 above, but rating 250 amps, 36 KA, thermal release 200-250% as specified and directed by Engineer-in-charge.
,---Ditto--- All as per Serial item No. 9 above, but rating 320 amps, 50 KA, thermal release 250-320% complete all as specified and directed by Engineer-in-charge.
,---Ditto--- All as per Serial item No. 9 above, but rating 400 amps ,50 KA,thermal release 320-400% complete all as specified and directed by Engineer-in-charge.
Supply only Standard push button flush head in different colours Red, yellow, green or black as required complete all as specified and directed by Engineer-in-charge. Make : L & T, Kaycee, Schneider.
Supply only LED indicator lamp 16 mm dia, 240 VAC, in different colours Red, yellow, blue, green or amber complete all as specified and directed by Engineer-in-charge. Make :L & T, Kaycee, Schneider.
Supply only PVC copper wire mulistrand copper conductor single core required for panel wiring including copper terminals, of size 1.5 sqmm complete all as specified and directed by Engineer-in-charge. Make : Havells, Polycab, Plaza, Anchor.
Supply only PVC copper wire mulistrand copper conductor single core required for panel wiring including copper terminals, of size 4 sqmm complete all as specified and directed by Engineer-in-charge. Make : Havells, Polycab, Plaza, Anchor.
Supply only PVC copper wire mulistrand copper conductor single core required for panel wiring including copper terminals, of size 10 sqmm complete all as specified and directed by Engineer-in-charge. Make : Havells, Polycab, Plaza, Anchor.
Supply only PVC copper wire mulistrand copper conductor single core required for panel wiring including copper terminals, of size 16 sqmm complete all as specified and directed by Engineer-in-charge. Make : Havells, Polycab, Plaza, Anchor.
Supply only cooling fan of existing specification, size and rpm etc complete all as specified and directed by Engineer-in-charge.
Supply only MCB triple pole, 415 VAC of rating 32 Amps,10 KA, complete all as specified and directed by Engineer-in-charge. Make : Havells, Legrand, L & T, Schneider
Earthing complete with galvanized steel earth plate electrode 600mm x 600 mm x 6mm buried directly in ground vertically to a depth not less then 6 meter below normal ground level with top edge of the plate not less then 1.25 meter below normal ground level connected to galvanized earth strip of size 32 x 6 mm thick by means of bolts, nuts, check nuts and washers complete up to and including test point including earthing pit, charcoal common salt, Earthing strip of 32x 6 mm up to 7.5m, 20 mm dia medium grade GI watering pipe, G.I. protection pipe 40 mm dia up to 7.5 m long, PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2010 (part-I) complete all as specified and directed by Engineer-in-charge.
Supply & fixing Water heater (Geyser) storage type, energy efficient, BEE 5 star rating, AC 230 volts of capacity 25 Ltrs, ISI marked complete with stainless steel water tank duly coated glass lining coating with corrosion resistant insulating material and rust free ABS body, having temperature cut off switch (thermostat) and anti-corrosion anode rod, braded inlet and outlet connections suitable for hot and cold water complete all as specified and directed by Engineer-in-charge. Make : Bajaj shakti 25 L GPV or equivalent model of crompton Greaves/Racold/Havells.
Supply and fix wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor, single core cable in PVC concealed conduit, 2 runs of 4 sqmm and 1 run of 4 sq mm as earth wire complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 15mm dia bore (Medium grade) GI with all fittings and fixed complete to walls and ceiling or laid in floors including complete all as specified and directed by Engr-in-charge.
Supply& Fixing 20 mm dia bore (Medium grade) GI with all fittings and fixed complete to walls and ceiling or laid in floors including complete all as specified and directed by Engr-in-charge.
S&F bib taps fancy type cast copper alloy screwed down crutch or buttefly handle screwed both ends for iron pipe brass ferrrule of size 15mm bore, ISI Marked complete all as specified and directed by Engineer-in-charge.
Supply & fix single pole & neutral enclosure with a two pin and earth plug & socket complete with one single MCB, 240 volt, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F stop valve cast copper alloy, fancy type, chromimum plated screwed down crutch or buttefly handle screwed both ends for iron pipe brass ferrrule of size 15mm bore, ISI Marked complete all as specified and directed by Engineer-in-charge.
S & F Gun -metal, globe or gate valves size 20 mm , with iron wheel head, screwed both ends for iron pipe and fixed ISI Marked, complete all as specified and directed by Engineer-in-charge.
S & F Nipple suitable for HDPE water tank suitable for 20 mm bore, making hole in existing tank and connecting for Geyser outlet, all fitting and fixtures complete all as specified and directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009, complete all as specified and directed by Engineer-in-charge. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
Supply, laying and testing of Cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable with stranded aluminium conductor 1100 Volt grade of size 95 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge.
Supply, laying and testing of Cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable with stranded aluminium conductor 1100 Volt grade of size 50 Sqmm, 3.5 core, complete all as specified and directed by Engineer-in-charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
M & L for locally available dry sand cushioning for cable protection complete all as specified and as directed by Engineer-in-charge.
Supply and laying best quality locally availble Sub class 'B' bricks (old size) for cable protection cover, laid flat and lay in trenches over the cable complete all as specified and as directed by Engineer-in-charge.
M & L for GI pipe light grade laid in trenches / fixed to pole / wall for cable protection of size 80 mm and making good excavated road with PCC relaying paver blocks ass required at site complete all as specified and as directed by Engineer-in-charge.
Supply installation commisioning, testing LT panel cubical outdoor type vermin proof complete with locking arrangement made out of 2 mm thick MS sheet duly parinted with 2 coats of synthetic enamelled paint over a coat of red oxide primer with aluminium bus bar cable alloy duly prewired comprising of the following:- (a) Bus bar chamber 3 phase and neutral aluminium 200 Amps rating insulated duly marked RYB and neutral with adhesive tape. (b) MCCB 125 Amp 415 volt breaking capacity 16KA triple pole and neutral link with adjustable thermal & magnetic release - 01 No (Incoming) (c) MCCB 63 Amp 415 volt breaking capacity 16 KA triple pole and neutral link with electronic release -02 No (Outgoing) (d) Three phase temper proof digital type Lt CT operated (inbuilt CTs) energy meter suitable for 415 V, 50 Hz AC supply of rating 10-60 Amp (e) Vol meter 0-500 volt with slector switch -01 Nos (f) Ammeter 0- 50 Amps with set of 3 CTs - 01 No (g) Indicating Lamps - 01 set of three (h) All accessories prewired with copper conductor cable single core of suitable size including suitable size of thimble. (j) Self supported angle iron frame 40 mm X 40mm X 5Mm thick stand grouted in PCC blocks completed excavation and earth work.
Taking down carefully copper/aluminium point wiring (light, socket or power), and making good disturbed surfaces of walls, floors etc to match with existing surfaces, complete all as specified and as directed by Engineer-in-charge. Note :- Fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces, complete all as specified and as directed by Engineer-in-charge.
Taking down sub main wiring of any size/capacity, and making good disturbed surfaces to match with the existing surfaces, complete all as specified and as directed by Engineer-in-charge.
M&L for concealed Point wiring with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sqmm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sqmm (FRLS) including MS shunk sheet metal box with 3 mm thick hylem sheet top cover of required size for mounting switches, sockets etc for One Light point controlled by one, one way switch complete all as specified and directed by Engineer-in-charge. Note: - Quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
,---Ditto--- All as per Serial item No. 48 above, but for One ceiling/exhaust fan point controlled by one switch and regulator.
,---Ditto--- All as per Serial item No. 48 above, but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches.
,---Ditto--- All as per Serial item No. 48 above, but for One 3 pin 5 amps switch socket outlet point on independent board.
,---Ditto--- All as per Serial item No. 48 above, but wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for 15 amps power point.
Supply and fix piano switch flush button single pole one way 5 Amps complete all as specified and as directed by Engineer-in-charge.
Supply and fix piano socket 2 in 1, 2/3 pin 6 amp flush type 230 volts AC complete all as specified and as directed by Engineer-in-charge.
Supply and fix piano socket 2 in 1, 3 pin 5 amp and 15 amp flush type 230 volts AC, complete all as specified and as directed by Engineer-in-charge.
Supply and fix piano switch 15 amp flush type 230 volts AC, complete all as specified and as directed by Engineer-in-charge.
S & F LED light fitting 1 x 20 W, 230 V integral sleek polycarbonate LED Channel with white acrylic cover including making connection complete all as specified and as directed by Engineer-in-charge.
Supply and fixing wall mounted decorative fancy type fitting including 9 watt LED bulb complete all as specified and as directed by Engineer-in-charge. Make : Havells LHSC0218499 or similar in Bajaj or Crompton.
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and as directed by Engineer-in-charge.
Supply and fix fan regulator electronic solid state with steps suitable for 1200/1400mm sweep ceiling fan working on 230 volt AC complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure DB single pole and neutral double door for 240 volts 12 way, with 200 Amps rated busbar flush/surface mounting double door including wooden board complete all as specified and directed by Engineer-in-charge.
Supply and fix sheet metal enclosure DB TPN 4 way, double door IP 42 /surface mounting double door complete all as specified and directed by Engineer-in-charge.
Supply and fix MCB single pole 240 volt 6-32 amps 10 KA, complete all as specified and directed by Engineer-in-charge.
Supply and fix MCB SPN 240 volt 63 amp 10 KA complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB TPN 415 volt 63 amp 10 KA complete all as specified and as directed by Engineer-in-charge.
Supply and fix factory made, sheet distribution boards, double door, TP & N 4 Ways, protection class IP-43 suitable for mounting MCB / MCCB, with min 200 Amps, copper bus bar, working on 240 V AC complete all as specified and directed by Engineer-in-charge.
S&F in DBs (catered above) MCB TPN 63 Amps complete all as specified and directed by Engineer-in-charge.
S&F in DBs (catered above) MCB isolator 4 pole 100 Amps complete all as specified and directed by Engineer-in-charge.
Supply and fixing LT in built CT operated three phase temper proof digital type energy meter 10-60 amps rating suitable for 415V, 50 Hz AC supply including polycarbonate box for installation of meter duly sealed complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting the sub main wiring of guest room No.1 & 2 and reconnecting through three phase energy meters complete after fixing the TPN DB.
Supply and fixing Single phase temper proof digital type energy meter 5-30 amps rating suitable for 230 V, 50 Hz AC supply
Material & Labour for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. Note :- Two run of 6 sqmm & One run of 4 sqmm & One run of PVC conduit with accessories shall be measured as One length. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Soma Enterprises
Ganganagar Enterprises
AYUSH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .