Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.9 L+₹20,233 (2.09%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹10.0 L+₹31,159.70 (3.21%)Rejected-Finance 736 PARAGDAS MANDIR NIRMOCHAN GHAT AYODHYA 224123 | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹10.4 L+₹72,617 (7.49%)Rejected-Finance FLAT NO 03 MALTI NIWAS AVADH VIHAR COLONY MANDAKNI BLOCK BEHIND RAILWAY STATION DISTRICT AYODHYA 224001 UP | AYODHYA | AYODHYA | UP | 224001 | L4 | Rejected-Finance Not being L1 | |
| 5 | Rejected-Technical MIG 444 AWADHPURI COLONY AMANATGANJ AYODHYA 224001 | AYODHYA | AYODHYA | UTTAR PRADESH | 224001 | - | Rejected-Technical Rejected - being not enlisted in eligible Class |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 Jun 2024, 6:00 pmClosed
AGE(I) Ayodhya Cantt
AGE (I) (MES) Ayodhya Cantt-224001
REPAIR MAINT AND REPLACEMENT OF GI WATER PIPE LINES, GATE VALVES AND CONNECTING WORKS ETC AT AYODHYA CANTT
2024_MES_655953_1
8400/008/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Ayodhya Cantt
₹20,000
Yes
30 Aug 2024
25 May 2024
17 Jun 2024
25 May 2024
14 Jun 2024
8 Jun 2024
Amount
Taking out 15 mm bore steel water tubing including fittings complete all as specified and directed by Engr-in-Charge. Note - Excavation, earth work and joint shall be measured and paid for seperately againt respective item of Schedule 'A' / BoQ.
All as per Srl Item No. 1.00 here-in-before but 20 mm bore pipe.
All as per Srl Item No. 1.00 here-in-before but 25 mm bore pipe.
All as per Srl Item No. 1.00 here-in-before but 50 mm bore pipe.
All as per Srl Item No. 1.00 here-in-before but 80 mm bore pipe.
S&F of 15mm bore GI pipe medium grade with all fittings and fixtures complete fixed to wall/ceiling or laid in floor /trenches etc. complete all as specified and directed by Engr-in-Charge. Note - Excavation, earth work and joint shall be measured and paid for seperately againt respective item of Schedule 'A' / BoQ.
All as per Srl Item No. 6.00 here-in-before but 20 mm bore pipe.
All as per Srl Item No. 6.00 here-in-before but 25 mm bore pipe.
All as per Srl Item No. 6.00 here-in-before but 50 mm bore pipe.
All as per Srl Item No. 6.00 here-in-before but 80 mm bore pipe.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) including cleaning of pipes of 20mm bore complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No. 11.00 here-in-before but 25 mm bore pipe.
S&F 15mm bore gun metal globe or gate valve 'ISI marked' with iron wheel head, screwed both ends for iron pipe all as per latest IS specifications complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No. 13.00 here-in-before but 20 mm bore gun metal globe or gate valve
All as per Srl Item No. 13.00 here-in-before but 25 mm bore gun metal globe or gate valve
All as per Srl Item No. 13.00 here-in-before but 50 mm bore gun metal globe or gate valve
Attending complaint for rectification of leakage of 80mm bore GI pipe line including excavation, returning and filling etc (if required) and replacing of defective / unserviceable fittings such as unions, sockets, bends, elbows, tees, nipples etc as per site requirement to rectify the leakage complete all as specified and directed by Engr-in-Charge. Note:- (i) The contractor or his authorised representative shall collect the complaint slips from JE I/C water supply and submit the same after rectifying the complaint duly signed by the users. (ii) The complaint shall be rectified within 24 Hrs from date of complaint failing which, a penal recovery of Rs 500/- per complaint per day shall be levied for the delayed period after 24 Hrs.
All as per Srl Item No. 17.00 here-in-before but 50 mm bore GI pipe.
All as per Srl Item No. 17.00 here-in-before but 25 mm bore GI pipe.
All as per Srl Item No. 17.00 here-in-before but 20 mm bore GI pipe.
All as per Srl Item No. 17.00 here-in-before but 15 mm bore GI pipe.
M&L for replacement of old rusted flat iron clamp of size 370 mm length 80 mm width and 6 mm thickness along with 25 / 50 mm hole in centre of the clamp and fixing of 25 / 50 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the desired curve on flat iron suitable for fixing on 150 mm pipe mains complete all as specified and directed by Engr-in-Charge.
M&L for replacement of old rusted flat iron clamp of size 370 mm length 65 mm width and 6 mm thickness along with 20 / 15 mm hole in centre of the clamp and fixing of 20 / 15 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the curve on flat iron suitable for fixing on 150 mm pipe mains complete all as specified and directed by Engr-in-Charge.
M&L for replacement of old rusted flat iron clamp of size 270 mm length 80 mm width and 6 mm thickness along with 25 / 50 mm hole in centre of the clamp and fixing of 25 / 50 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the curve on flat iron suitable for fixing on 100 mm pipe water mains complete all as specified and directed by Engr-in-Charge.
M&L for replacement of old rusted flat iron clamp of size 270 mm length 65 mm width and 6 mm thickness along with 20 / 15 mm hole in centre of the clamp and fixing of 20 / 15 mm socket on clamp for fixing of GI pipe and two holes on each side end of clamp for fixing of nut bolt and washer including smith and lathe work for making the curve on flat iron suitable for fixing on 100 mm pipe water mains complete all as specified and directed by Engr-in-Charge.
Attending complaint for rectification of leakage in 150 mm bore DI pipe line with push on joints complete by rubber gasket or flange spigot and socket fitting, any bend or tee including necessary nut bolts & washers etc including excavation for any lenght of pipe by using labour as well as returning, filling complete all as specified and direcrted by Engr-in-Charge.
All as per Srl Item No. 26.00 here-in-before but 100 mm bore pipe.
Attending complaint for rectification of leakage in 150 mm bore DI pipe line with flanged joints fixed to pillar of RCC overhead reservoir upto 21 meters height or below ground level complete by rubber or fibre board gasket, blank flange with screwing or threading on lathe machine, desired chemicals for leakage inside floor of overhead tanks where pipes are attached including necessary nut bolts & washers etc including excavation by using labour as well as returning, filling etc complete all as specified and direcrted by Engr-in-Charge. Note:- (i) The contractor or his authorised representative shall collect the complaint slips from JE I/C water supply and submit the same after rectifying the complaint duly signed by the users. (ii) The complaint shall be rectified within 24 Hrs from date of complaint failing which, a penal recovery of Rs 2500/- per complaint per day shall be levied for the delayed period after 24 Hrs.
All as per Srl Item No. 28.00 here-in-before but 100 mm bore DI pipe.
Taking up 150 mm bore spigot and socketed pipe with rubber gasket including fittings complete all as specified and directed by Engr-in-Charge. Note - Excavation, earth work and joint shall be measured and paid for seperately againt respective item of Schedule 'A' / BoQ.
Relaying 150 mm bore ductile iron pipes spigot and socketed ends centrifugally casted class A 'ISI marked' in any length laid in trenches including cleaning of pipe all as specified and directed by Engr-in-Charge. Note - Excavation, earth work and joint shall be measured and paid for seperately againt respective item of Schedule 'A' / BoQ.
M&L for rubber gasket joints for spigot and socket pipes and fittings of size 150 mm dia complete all as specified and directed by Engr-in-Charge.
M&L for specials / fittings of spigot socketed pipes of bore upto 150 mm such as bend, tee, flange, socket, collar Reducer, Tail Pieces Y junction double, cross, D joint, MJ collar etc complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying / taking out water supply pipe line in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified and directed Engr-in-Charge.
Returning filling in including,spreading, levelling watering and well ramming in layer in n.exc 25 cm in soft/lose soil all as specified directed Engr-in-Charge.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point as in soft/loose soil complete all as specified and directed Engr-in-Charge.
Taking out unserviceable sluice valve 150 mm bore from water mains all as specified and directed by Engr-In-Charge
All as per Srl Item No. 37.00 but 100 mm bore.
S&F connection & testing sluice valve 150 mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts and gasket etc for fixing and taking out of old valve complete all as specified and directed by Engr-In-Charge of the following sizes :- Note: For sluice valves fixed with pillars of over head tank, breaking of RCC / lead / flange joints and repairing the same after fixing of valve deemed to be included in the quoted rates
All as per Srl Item No. 39.00 but 100 mm bore.
M&L for replacing of gland packing,nut-bolts and washer of sluice valve of 150 mm bore complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No. 41.00 but 100 mm bore.
M&L for replacing of gun metal check nut of sluice valve of 150 mm bore complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No. 43.00 but 100 mm bore.
M&L for replacing of existing size gun metal spindle of sluice valve of 150 mm bore complete all as specified and directed by Engr-in-Charge.
All as per Srl Item No. 45.00 but 100 mm bore.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 10 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-in-Charge. Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Repair and maintenance of defective Monoblock motor pump any make & model of capacity 7.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing complete all as specified and directed by Engr-in-Charge. Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
Repair and maintenance of defective Monoblock motor pump any make & model of capacity upto 2.5 HP including required repairing like motor rewinding, replacement of minor spares like Motor bearing, Gland packing, Fan motor blade, Packing paper, Water seal, Starting Coil, Motor housing, S.S . sleeve repairing on Lathe ,Impeller Brass, Gun Metal Bush, Rubber Coupling Set, Rubber bush, Rubber gasket, nut bolt & any other minor connected items and testing after repairing including painting complete all as specified and directed by Engr-in-Charge. Note: All type of T&P including dismantling and fixing required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.
M&L for applying two coats of synthetic enamel paint on distribution header of DI pipes & fittings including writing of location to be fed on each disribution point including sluice valves of various pump houses after scraping/ preparing of old surfaces complete all as specified and directed by Engr-in-Charge.
M&L for writing of slogan "SAVE WATER SAVE LIFE" in english language alphabet on external surfaces of pump house boundary wall including each alphabet has font size of 2 x1.5 feet with 0.5 feet spacing in suitable colour after preparation of old external boundry wall surface by taking down of old/ broken tiles, scraping, washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of cement based paint on complete external surface of pump house boundary wall complete all as specified and directed by Engr-in-Charge. Note: - (i) Before applying cement paint, the complete external boundry wall surface shall be thoroughly wetted to control surface suction. (ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used.
His And Her Enterprises
disha construction
K R KAUSHAL AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .