Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC | ₹6.7 Cr | L1 | Accepted-AOC BEING L1 BIDDER |
| 2 | L2₹7.3 Cr+₹60.9 L (9.10%)Rejected-Finance | ₹7.3 Cr+₹60.9 L (9.10%) | L2 | Rejected-Finance NOT BEING THE LOWEST |
| 3 | L3₹7.4 Cr+₹74.3 L (11.1%)Rejected-Finance | ₹7.4 Cr+₹74.3 L (11.1%) | L3 | Rejected-Finance NOT BEING THE LOWEST |
| 4 | L4₹8.0 Cr+₹1.3 Cr (18.8%)Rejected-Finance NOT SPECIFIED | ₹8.0 Cr+₹1.3 Cr (18.8%) | L4 | Rejected-Finance NOT BEING THE LOWEST |
| 5 | L5₹8.5 Cr+₹1.8 Cr (27.3%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹8.5 Cr+₹1.8 Cr (27.3%) | L5 | Rejected-Finance NOT BEING THE LOWEST |
Tender Value
₹7.4 Cr
EMD Value
₹7.0 L
Closing Date
3 Jan 2020, 6:00 pmClosed
HQ CE (Navy) Mumbai
26, Assaye Building Colaba Mumbai - 400005
PROVISION OF DEFICIENT MARRIED ACCN FOR DSC PERSONNEL AT INS MANDOVI GOA
2019_MES_278976_1
87720/E8
Open Tender
Civil Works
Lump-sum
540 days
Mandovi
As per tender documents
9 documents required · 9 mandatory
₹3,000
Yes
AGE (I) Mandovi
₹7.0 L
Yes
9 Mar 2020
31 Aug 2019
10 Jan 2020
31 Aug 2019
3 Jan 2020
20 Dec 2019
31 Aug 2019 - 16 Sept 2019
Amount
Total amount of Sch 'A' Part-I (BUILDINGS & STRUCTURES) brought forward from Serial Page No. 31 (R)
Total amount of Sch 'A' Part-II ( EXCAVATION , EARTH WORK, SITE CLEARANCE AND DEVELOPMENT) brought forward from Serial Page No. 33(R)(R)
Total amount of Sch 'A' Part-III (INTERNAL WATER SUPPLY) brought forward from Serial Page No.34
Total amount of Sch 'A' Part-IV ( HOT WATER SUPPLY ) brought forward from Serial Page No.35
Total amount of Sch 'A' Part-V ( INTERNAL ELECTRIFICATION )brought forward from Serial Page No.38(R)
Total amount of Sch 'A' Part-VI ( SEWAGE DISPOSAL )brought forward from Serial Page No. 40(R)
Total amount of Sch 'A' Part-VII ( AREA DRAINAGE ) brought forward from Serial Page No. 41
Total amount of Sch 'A' Part-VIII ( EXTERNAL WATER SUPPLY ) brought forward from Serial Page No. 43(R)
Total amount of Sch 'A' Part-IX ( EXTERNAL ELECTRIFICATION ) brought forward from Serial Page No.46
Total amount of Sch 'A' Part-X ( LIGHTNING PROTECTION )brought forward from Serial Page No.47
Total amount of Sch 'A' Part-XI ((ROAD, PATH , HARD STANDING & CULVERT) ) brought forward from Serial Page No. 49
Total amount of Sch 'A' Part-XII ( RETAINING WALL ) brought forward from Serial Page No. 51(R)
Total amount of Sch 'A' Part-XIII ( FIRE FIGHTING ) brought forward from Serial Page No. 54(R)
Total amount of Sch 'A' Part-XIV ( LIFT ) brought forward from Serial Page No.55
Total amount of Sch 'A' Part-XV ( SOLAR ENERGY ) brought forward from Serial Page No 56
Total amount of Sch 'A' Part-XVI ( WATER HARVESTING ) brought forward from Serial Page No 57
Sch 'A' Part- XVII - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
INTERNAL WATER SUPPLY :- S&F Over head Shower 120 dia with wall mounted shower arm Make - Jaquar Model No OHS-1789&SHA-477 or equivalent as approved.
S&F Two way bib tap/angle cock 15 mm Make - Jaquar Model No CQT-23041 or equivalent as approved
S&F Health faucet with flexible pipe (ABS body) with 01 meter long PVC tube & wall hook Make Jaquar Model No ALD-chr-583 or equivalent in Crab Tree or Kohler brand
S&F Long body bib cock 15 mm Make - Jaquar Model No CON-107KN or equivalent as approved
S&F Angular stop cock 15 mm dia with wall flange Make - Jaquar Model No CQT-23059 or equivalent
S&F Concealed stop cock 20 mm dia regular bodywith adjestable wall flange Make - Jaquar Model No CQT-23089 or equivalent as approved
S&F PVC Connection 450 mm long braided hose with two 15 mm nuts & rubber washer without nipple(suitable for geyser) all as specified Make - Jaquar Model No ALD-805B or equivalent as approved
S & F CPVC Gate valves suitable for size 50 mm outer dia CPVC pipe and fixed including threaded nipple and union Make:- Prince or Asthal
S&F bib tap 15 mm dia heavy duty fancy type chromium plated finish with crutch or butterfly handle screweddown for CPVC pipe or for brass ferrule Make - Jaquar Model No CON 107 KN or equivalent as approved
EXTERNAL WATER SUPPLY:- M/L for cutting of existing CI pipe line of 100 mm for taking branch connection and insertion of CI Tee of size 100mm x 100 mm x80mm
Supply and fix Brass foot valve 80mm (3") dia conformimg to IS:4038, dead weight plunger with guide weight, rubber flap complete with jointing materials ie. rubber gasket, nuts, bolts and washers etc complete all as specified and directed .
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 285 LPM discharge at 50 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed .Note : (i) Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building) Note (ii ) Energy Efficient Motors-Motors shall comply with following:-
(a). All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors (b). Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% (c). Motor horse power rating shall not exceed 20% of the calculated maximum load being served (d) Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor (e). Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices
(f). Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump )
INCOMER
(a) MCCB TPN 32 Amps, 50 Hz, 415 Volts, 25 KA -01 No
OUT GOING
(a) MCCB TP 16 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For main pump)
(b)Automatic Starter delta starter for 7.5 HP pump with inbuilt over load and earth fault relays, contactors, reverse protection -02 Nos( For main pump)
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) Single phasing preventer -02 Nos
M & L for construction of brick masonry chamber of internal dimension of 90cmx90cmx90cm with bricks class designation 75, in CM (1:6) with PCC (1:4:8) type D2 for foundation including 15mm thick plastering in CM (1:4) inside the chamber and on the external portion exposed above ground level, including 3mm thick MS cover welded around with MS flat iron of size 40x6mm including MS angle iron frame of size 40x40x6mm with locking arrangement including painting with two coats of black bituminous paint over a coat of anti corrossive red oxide primer including necessary earth work in soft/loose soil well ramming of soil around the constructed chamber all as specified and directed by Engr-in-Charge.( 02 nos Ext Water Supply)
INTERNAL ELECTRIC SUPPLY
S &F Lamp holder insulated body with back plate and Including LED lamp 9 watt for angle holder all as per specified
S &F modular AC Box ( geyser ) sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 20 amp C series MCB protected.
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos Make-WIPRO /HAVELLS /JAQUAR /PHILLIPS as approved
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenally prewired & including coneecting up with 2 core flexible copper conductor cable with suitable size & suitable for and mounting clamps PVC square box 75x75mm - 2 nos etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS as approved
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x8/9 Watt ( for mirror light) ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible copper conductor cable with suitable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS as approved
S & F LED Security/Street light fittings 15 Watt, IP 65 wall mounting type extruded metal/aluminium body, and electronic LED driver, etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS as approved
Supply & fix including fabrication of GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting
S & F for MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door , L&T CAT NO-DBVTL008DD or equivalent in LEGRAND Schneider / ABB
M & L for MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps Make: - LEGRAND/HEGGER/SCHNEIDER/L & T
M & L for MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps Make: - LEGRAND/HEGGER/SCHNEIDER/L & T
M & L for MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 32 Amps Make: - LEGRAND/HEGGER/SCHNEIDER/L & T
M & L for RCBOs 30 mA , 2 Pole breaking capacity 10 KA of rating 6-32Amps Make: - LEGRAND/HEGGER/SCHNEIDER/L & T
M & L for MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating Make: - LEGRAND/HEGGER/SCHNEIDER/L & T
M & L for MCCB TPN 100 Amps , 415Volts, 25KA ,4 POLE L&T CAT NO-CM91198OOLO/ LEGRAND CAT NO-420055 / / schneider/ ABB
S&F Exhaust fan heavy duty of size 225/230 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Exhaust fan heavy duty of size 300 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. -Make : Crompton Greaves/ Bajaj/Orient
M&L for non metalic PVC rigid conduit of size 25 mm dia including bend ,tee,elbow reducer fixing accessorries
M&L for PVC junction box up to 4 Way
M&L for TV SOCKET with Modular metal flushed including flushed Box cover plate Box for 2 Way module
Supply & fix elecronic energy meter,temper proof,operated on 240 V AC ,single phase, 5 amps to 40 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-1, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), deficiency metering with either phase/netral current, IP 51 protection ,as per IS13779, with optical port RS 485 & WiFi Module ,complete , L&T model no- EM101 & Cat no- WD4000101OOO of L&T or equivalant of secure ( elecronic energy meter to be fixed in 12 way DB)
S & F Aviation light type LED type IP65 protection Cat No - SLE AL - LDR -SEN IP65 of Surya or BAJAJ Cat No BJAV 302 or equivalent make in PHILLIPS as approved
S & F enclosure flush mounting type suitable for MCB SPN 2 way with MCB SPN 6 Amps ( For Aviation light )
EXTERNAL ELECTRIC SUPPLY
Supply, install, testing and commisioning of Distribution transformer mounted on massoniry platform stepdown , 11KV / 0.433KV , Three Phase complying with IS: 1180 (Part-I1) 2014 with latest amendments , Outdoor type double copper wound suitable for 50 Hz system of capacity 100 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in steP of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.80 % & 1.04 % Respectively per GRAHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : -
(a) Lifting lug for transformer and tank. (b) Earthing terminal rating and diagram plate.(c ) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator(g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (k) Type of connection Delta/Star (l) Type of cooling: Oil and Natural Air. (m) Vector group:DYN 11. (n) Temperature rise over an ambient of 50 °C maximum. (o) Cable end box on both side for HT/LT cables of suitable size. (p) Provision of thermometer with pocket. (q) Provision of oil and winding temperature gauge.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Pannel Board made out of 3.00 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - near transformer)
INCOMING:-
(a) MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92109OOM1OG /Legrand cat no-420247/schneider cat no-LV516343 -1 no
OUTGOINGS:-
(b) MCCB TP 100 Amps , 415Volts, 35KA ,3 POLE L&T CAT NO-SL98652OOOO/ LEGRAND CAT NO-420085 / equivalent of ABB - 1no , (for building main MCCB DB)
(c) MCCB TP 63 Amps , 415Volts, 25 KA ,3 POLE L&T CAT NO-SL97207OOOO/ LEGRAND CAT NO-420084 / equivalent of ABB - 3 nos (for DG , Capacitor & Spare )
(d) Aluminum TPN bus bar 250 Amps - 01 Set
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(h)Elecronic energy trivactor meter,suitable for 3 phase 4 wire CT operated ,temper proof,operated on 240v AC ,three phase, 5 amps to 10 amps, base mounting meter, backlit LCD display with user friendly legend, accuracy class-0.5, MD recording, revenue protection ( in case of wrong electric connection),capability to disply & communicate ( in case of absence of main supply), with optical port,deficiency metering with either phase/netral current, IP 51 protection, as per IS13779,including CT 150x5 amps, L&T model no- ER300P & Cat no-WR300BC5200 of L&T or equivalant of secure
(j)power capacitor bank , Utra heavy duty, BOX type Oil filled, LTXL OF L&T or equvalant of APCOS/siemens/momaya suitable for 480V,20 KVAR- 1no
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Pannel Board made out of 3.00 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (DG Set Pannel)
INCOMING:-
(a) MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315
OUTGOINGS:-
(a) MCCB TP 32 Amps , 415Volts, 35KA ,3 POLE L&T CAT / LEGRAND / equivalent of ABB - 06 no ( for Lift , Commen lighting DB , Water supply pump , Booster Pump , Water Harvesting Pump , Spare)
(b) MCCB TP 16 Amps , 415Volts, 35KA ,3 POLE L&T CAT / LEGRAND / equivalent of ABB - 02 nos (for ST LT & Spare)
(c) Astrorex D-22, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T/MDS/GIC-1no
(d) Aluminum TPN bus bar 100 Amps - 01 Set
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(h)Power contactor ML-1.5 , 3 pole rating not less than 32 A with 230 coil make L&T/SEIMENS 1 no
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Supply and fix LED solar street light fitting 40 Watts complete with bracket made out of 40mm dia GI light grade tubing not less than 1.5mtr long bent to shape 120 deg including pole clamps (2 nos), clamp for fixing GI conduit pipe bracket made out of 50x6mm flat and nut bolts and washers etc all as directed . Make :Crompton Greaves Cat Ref No. STARLET LST2-40-CDL 40Watts./Phillips/Bajaj
Supply & fix PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 mtr complete with 1 No MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated , PVC sheathed wire 2.5 Sqmm copper & PVC coduit 20 mm dia. Make of Box- SPELS BERG/RITTAL/HENSEL CAT NO K8350 as approved.
Supply and fix cable route indicator made out of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revetted with angle of size 50x50x4mm and 60cm long including PCC (1:2:4) Type B1 using 20 mm graded stone aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revetted with angle of size 50x50x4mm and 60cm long including PCC (1:2:4) type B2 using 20 mm graded stone aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 40 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
(b)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make: Kirloskar/ashok leyland/cummins
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators.(j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump.(m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12 V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-12 volts Battery -1 no DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Alternator: Suitable rated 40 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stampford/crompton/kirloskar
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 40 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 63 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00 mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) [ 04 nos for Int Elect + 02 nos for ext elect + 04 nos for water harvesting ]
FIRE FIGHTING
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 900 LPM discharge at 35 m Head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Note : Energy Efficient Motors-Motors shall comply with the following :-
(a) All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors (b) Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% (c) Motor horse power rating shall not exceed 20% of the calculated maximum load being served, (d) Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor (e) Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices (f) Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB shall be MDS/LEGRAND/L&T/HEGGER
INCOMING:-
(a) MCCB TPN 32 Amps, 50 Hz, 415 Volts, 25 KA -01 Nos - 1 no
OUTGOINGS:-
(a) MCCB TPN 25 Amps, 50 Hz, 415 Volts, 25 KA -02 Nos (For tarrece pump)- 1 no
(b)Automatic Starter delta starter for 15 HP pump with inbuilt over load and earth fault relays, contactors, reverse protection -02 Nos( For main pump)
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) Single phasing preventer -02 No
Supply and lay control cable PVC insulated PVC sheathed galvanised steel strip or wire armoured with stranded copper conductor of size 1.5 sqmm 2 core 1100 Volts grade
M & L for Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) NOTE-: GI earth strip shell be measured and paid for separately under relevant item of schedule .[ 06 Nos External water supply + 24 Nos External Electrification + 06 Nos fire fighting + 08 Nos Lightning protection + 02 Nos Lift + 02 Nos water harvesting ]
Supply and fix Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete of size 80 mm bore
GRIHA STAR RATING
SOLAR ENERGY
Supply, Installation, Errection, Testing and Commissioning of Grid Connected Solar PV Plant of 6 KWp capacity with Solar PV (make : Sharp/ Conadian Solar/ TATA BP Solar) modules, tool kit and mounting structure with fasteners, nuts, bolts alongwith foundation design as per manufacturer's instructions subject to approval of GE with following features complete all as specified and directed :-
(a) Solar PV Module of Crystalline-Si (Poly/Multi) solar technology shall have effeciency 15%. (b) The PV Modules shall be with minimum rated power of module not less than 300 Wp certified for solar PV module power performance tested as per IEC 61215 (Design qualification and type approval for Crystalline Si modules) and IEC 61730 (PV module safety qualification testing @ 1000 V DC or higher) and capable of generating 6 Kwp together in Array arrangement as required. (c) Photovoltaic modules shall carry a performance warranty of >90% during the first 10 years, >80% during the consecutive 15 years and module cell shall have performance warranty of >97.5% during the first year of installation. (d) The module mismatch losses for modules connected to an Inverter shall be less than 2%. (e) The SPV module shall be made up of high transmitivity glass & front surface shall have high encapsulation gain and the module shall consists of impact resistance, low iron and high transmission toughened glass. (f) The module frame shall be made of high strength aluminium alloy or Galvanized steel section as per manufacturer's instruction's (non corrosion material), which shall be compatible with the structural material used for mounting the modules with sufficient numbers of grounding/installation. (g) All material used for manufacturing solar PV module shall have a proven history of reliability and stable operation in external applications. It shall perform satisfactorily with temperature between (-)40° C to (+) 85° C and shall withstand adverse climatic conditions, such as high speed wind, blow with dust, sand particles, saline climatic / soil condtions and for wind speed 180 Km/hr on the surface of the panel.
(h) Each Array junction Box shall have suitable Reverse Blocking Diodes/Fuses of maximum DC blocking voltage of 1000V with suitable arrangement for its connecting. (j) The terminals shall be connected to copper bus-bar arrangement. The junction boxes shall have suitable cable entry points fitted with cable glands. Note : (i) Rate quoted shall also be deemed to include of all installation and fixtures for solar panel, foundation, mounting structures, fixing fastners, nuts, bolts as required as per manufacture's instructions and as directed by GE. (ii) The solar PV plant shall be installed at roof as directed by GE. (iii) The module shall be mounted on PCC 1:2:4 type B-1(using 20mm graded stone aggregate) blocks of sizes as directed by the GE on roof top including suitable alluminium alloy / Galvanized steel structure (iv) The contrctor shall submit the drawing containing the layout, design and other relevant details of the components of solar plant for aproval of GE and get approval from the GE before procurement and starting the execution of work.
Supply, installation, testing & commissioning Solar Grid Tie Inverter minimum 7 kW-capacity, 3 phase, AC operated (Make : SCHNEIDER/ABB/SIEMENS/DELTA) with following features complete all as specified and directed :-
(a) The inverters shall include the system for initialisation from the sleep mode and it shall be ensured that suffcient sunlight in the morning is available to provide adequate power to inverter so that it shall start up from the over night sleep mode and the Utilty Grid is available. The inverter shall be programmed to a logic and a pre-set window of existing Grid voltage and start evacuating due to any reason,the inverter shall come to idle mode till the Grid comes back again. (b) Even during the power evacuation, if the sunlight falls below the desired limit due to clouds etc, the inverter shall also stop working, although the Grid is available, till it starts getting the desired solar power required to power the inverter itself. As soon as it attains the power evacuation stops and only inverter keeps running till the power drops further low due to decreasing sunlight in the evening, resulting in the inverter going to sleep mode to initialize again automatically the next morning. (c) The Solar inverter shall also have the following salient features :- Economical :(i) Maximum effciency 98.5% (ii)Opti Trac MPP tracking for best MPP tracking effciency. (iii)Active temperature management. Simple:(i) Three-Phase grid feed-in,Grid voltage will be 415volt. (ii) Cable connection without tools.(iii) DC plug-in-system. (iV) SCADA compatible with communication capability. Flexible and future proof :(i)DC input voltage up to 1000v (ii) Integrated grid management functions.(iii)Reactive-Power capable.
Supply and fix DC DB, with and including 1000V grade, DC, MCB, DP, 32A and also including SPD and connectors in Combiner Box, complete all as specified and directed, Make : SCHNEIDER/ABB/SIEMENS
Supply and fix AC DB, with and including 415V grade, MCB, FP, 63A, 'C' series and also including SPD and connectors in Combiner Box , complete all as specified and directed, Make : SCHNEIDER/ABB/SIEMENS
Supply and fix two core PVC insulated copper multi strandered 4 sqmm solar cable, 1.8 KV grade, drawn through and including PVC conduit of size 20mm dia and conduit accessories, fixed on surfaces, floor, wall etc, complete all as specified and directed, Make : Havells/Polycab
Supply and fix single core PVC insulated, 1.5 KV grade DC copper conductor cable 4 sqmm drawn through and including PVC conduit of size 20mm dia and conduit accessories fixed on surface of floor, wall etc for array interconnection and to invertor, complete all as specifiecd and directed, Make : Havells/Polycab
Supply and fix single core PVC insulated copper multi strandered cable 16 sqmm, 1100 V grade, drawn through and including PVC conduit pipe of size 40mm dia and conduit accessories fixed on surfaces, floor, wall etc complete all as specifed and directed, Make : Havells/Polycab
M&L for Chemical Earthing complete with copper earth plate electrode 600x600x3.15mm thick buried directly in ground vertically (earth pit not less than 4.50 metre deep below normal ground level with edge of the earth plate at a depth not less than 3.4m below ground level), earth plate connected to and including copper strip of size 32x6mm by means of copper nuts, bolts,check nuts and washers etc, and connected to test point and earth dolly all as shown in electrical plate No 03 of SSR Part-I 2009 and specified or indicated including providing charcoal dust 250 Kgs(minimum), common salt 200 Kg(minimum), magnesium sulphate 100 Kgs(minimum) and all around the plate 15 cm depth and wide and upto 650 mm height in continuous layers, balance pit will be filled with vegitable soil upto ground level, including excavation and earthwork in any type of soil, PCC (1:2:4) type B1 in chamber, precast RCC 1:2:4 type B-1, 50 mm thick cover, reinforced with XPM (Weight not less than 4.00 Kg/Square meter) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40mm bore medium grade GI protection pipe upto 7.5 metre etc complete all as specified and directed. Note: (i) Quoted rates shall also be deemed to include the cost of 7.5 meter GI pipe for protection of earth lead.and 7.5 meter Copper Earth strip. (ii) The qoted rate is deemed to be inclusive of removal of the excess materials from the work site. (iii) Earth resistance of earth pit shall be less than 0.5 Ohms. (iv) On testing after completion if the desired earth resistance in not obtained, the earthing will be redone by the contractor at no extra cost till the desired eath resistant is obtained.
Supply and fixing MCCB, 4 pole, 415V, 50Hz, 63 Amps, 16 KA, fixed type with and including sheet metal enclosure, complete all as specified and directed.
WATER HARVESTING
Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 125 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Note - Energy Efficient Motors-Motors shall comply with following :-a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors
b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64%
c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served,
d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor
e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices
f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( for Rain water harvesting)
INCOMING:-
(a) Incoming MCCB 32 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider-01 No
OUTGOINGS:-
(b) Outgoing MCB, SPN 16 Amp, 240 volts -02 Nos ( for Rain water harvesting)
(c )DOL starter suitanble for 5 HP motor- 2 nos
(d) single Phase Preventer -2 nos
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) MCB SPN 6-32 amps-01 No
Supply and fix brass foot valve, screwed end and drilled of size 25 mm dia ISI MARKED
Supply and fix brass non return valve, screwed end and drilled of size 25 mm dia ISI MARKED
PLANTATION OF TREES
Supplying and planting of best quality healthy plants ( Gulmohor ) at site by excavating pits of size 0.75 x0.75 x1.20 mtr ( LXBXD ) filling the pit with fresh garden soil /silt, sand and manure in ratio 2:1 by volume ( 2 parts of stacked volume of manure after reduction of 8% ) mixing soil/ silt sand and manure throughly well , levelling as directed watering previous night , planting 1 or 2 year old healthy and 1.2 mtr tall specific features trees , sappling as per specifications including watering ( till completion certificate is issued ) weeding, stirring of soil replacing of casualities etc complete all as directed. Note : The rate quoted shall be inclusive of necessary excavation and earthwork and removal thereof as directed.
HOT WATER SUPPLY
S&F Closed Stationary Storage type water heater geyser, 5 star rating, operating on 230 volt AC, inner tank made out of mild steel,outer body made out of PVC ,coil wattage 2000 W , of capacity 25 lit ,including earth leakage circuit breaker,& Built-in-NRV, nut bolt & washer , make HAVELLS model no-PURO PLUS or equvivalant of CROMTEN/RACOLD/BAJAJ
LIFT: Comprehensive maintenance and repairs of fully automatic electrically operated passenger lifts of any Make and installed capacity against Sch 'A' part XIV Item No 1 with a carrying capacity of 08 Passenger (544 Kg) to serve (G + 5Floors ) with AC variable voltage & variable frequency (VVVF drive) complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors wth VVVF door drive (electric motor driven mechanism), sliding stainless steel door automatic rescue device (ARD) system , 3D infra red sensor in full height of door) and built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 60 months ( including defect liability period of 24 months ) for all days including holidays etc after expiry of defects liability period as shown below and all as specified and dierected to GE. Note : (i)Contractor shall carryout comprehensive maintenance (routine, daily , weekly , monthly , quarterly , half yearly, yearly ) as per attached Performa and maintain all the lifts in serviceable condition 24 hrs X 365 days without any extra cost .(ii) WO for maint of lifts shall be issued by GE after completion of defect liability period for every consequent year for total period of 3 years.(ii) Final bill shall be paid after certified completion of work for each WO seperately.
(a)1st year after expiry of defect liability period
(b) 2nd year after completion of work of serial No 19.01 above
(c) 3rd year after after completion of work of serial No 19.02 above
(a)1st year after completion of work & taking over site by users (whichever is later)
(a) II nd year after completion of work of serial No 19.05 above
(a) Third year after completion of work of serial No 19.06 above
(a) Fourth year after completion of work of serial No 19.07 above
(a) Fifth year after completion of work of serial No 19.08 above
(a) Sixth year after completion of work of serial No 19.09 above
NOTES FOR ITEM NOS 19 TO 19.10 : (a) The Contractor shall Employ General mechanical / Electrical /FGM having minimum ITI qualification from Govt Recognized institute with adequate knowledge & minimum 2 years experience in maint/operation of lift installations. The operator must competent to carry out the minor maint as all dierected .(TOTA number of operators required per day are 02 nos.) (b) Contractor shall pay the wages to the employees through e-payment i.e Adhaar linked Bank accounts (credit to their bank account). Engineer-in-charge shall ensure that e-payment made to employees and their wages shall not be less than minimum wages fixed by state Govt or Central Govt whichever is more . Monthly e-banking statement shall be firnished by the contractor to the Engr-in-charge and the same shall be kept in record duly verified. (c) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevailing scales as laid down by Ministry of labour for all operator / helper (as applicable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemed to be included of above provision . In case contractor fails to produce the proof of EPF , the same shall be recovered from his dues as per the prevailing scale plus 15 percent. (d) The operator employed by the contractor shall be capable of carrying out minor repair / maintenance & should have well experience in lift installation as applicable.
S.N. Constructions
SLB Enterprises
United Sales Corporation
Idustrial products India
M/s. R.S. LAWANDE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .