Replacement of old Split AC by new one and re-structuring of electrical wiring in the inspection house situated at Ghaziabad district.
2026_CEEMP_1120748_1
3320 /6WE(MRT)- E.M. Circle Agra Dated 13/02/2026
Open Tender
Electrical Works
Percentage
90 days
GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹766
₹1.4 L
Yes
EE ED PWD MEERUT
16 Apr 2026
27 Feb 2026
9 Mar 2026
27 Feb 2026
9 Mar 2026
27 Feb 2026
6 Mar 2026
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating.
4 KVA Voltage Stablizer for Air Conditioner Upto 2TR (130-300V Range) Copper Winding with 3years warranty. Make: V-Guard/Microtech or equivalent
Dismantling & Shifting of split A.C. unit (Indoor, Outdoor) to site store complete work.
SITC of Suction/Discharge Copper pipe line in split AC unit 1.5 ton capacity including brazing, nitrile rubber insulation 6mm thick class 'O' etc complete 1/4" (6.40 mm) and 1/2" (12.70 mm)
S/F of 25mm dia CPVC pipe with all fittings including all material, labour etc. complete in all respect for drain water.
S/F of Outdoor unit stand for split type AC.
Supply and fixing of 2.5 Sq.mm 4 core PVC insulated round sheathed Cu Conductor cable. Make Havells/KEI or equivalent.
Supply of 2.5 sq.mm, 3 Core PVC insulated Round Cu conductor Cable for A.C. Connecting Indoor/Outdoor. Make Havells/KEI or equivalent.
Gas Filling and complete servicing of old Acs.
Supply of 10W LED Bulb with 1 year warranty. Havells/Philips make.
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
Supply & fixing of water tight oblong 10watt bulkhead luminaire having pressure die casting housing with driver set confirming ti IP65 and above protection, IK 08, high purity/transitivity UV stablised non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24hr continious operation, complete in all respect. 1100 system lumens, >110Lm/W, PF>0.95, THD<10%, CRI>80, with 3 years warrantee. CAT-AA.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 watt.
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 18 watt.
S/F 20A, 240V, SPN industrial type socket outlet with 2pole and earth, metal enclosed plug top alongwith 20A "C" curve, SPMCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning as required.
Wiring for circuit/submain wiring of 2X6 sqmm. alongwith 1 No. 6 sqmm. as earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Wiring point for Light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Installation of the exhaust/fresh air fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450mm sweep
Extra for fixing the louvers/shutters complete with frame for a exhaust/fresh air fan of all sizes.
Supply of metal body ventilating fan 250 mm sweep. Havells/ Crompton/ Bajaj or equivalent make
Refilling of CO2 Type 4.5Kg Fire Extinguisher cylinders with complete pressure testing report and replacement of minor parts like pressure gauge and hose pipe as per requirement and labeling of its life on the cylinders.
Providing and fixing of 6 kg. Capacity ABC Stored Pressure type Fire Extinguisher bearing ISI Mark for Fighting ABC Class of Fire.The Extinguisher will be Manufactured Strictly as per BIS: 15683:2006 bearing ISI. mark. EN3 615 Approved Powder. ABC 87% MAP. Valve with additional facilities like Operating temperature marking on valve, Automatic safety release valve & Non Returnable Valve. Cease Fire or equivalent make
Providing and fixing of capacity - 4.5 kg. C02 type fire extinguisher (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Cease Fire or equivalent make
Supply and fixing 25L capacity electric storage water heater/Gyser with 2kW rated power complete in all respect. Havells or equivalent make
Repairing/Service of Electric storage water heater 25 litre capacity
SITC of LT Panel fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade alongwith canopy as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of electrical grade high conductive Aluminum alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The bus bar shall be supported by non hygroscopic SMC/DMC bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully segregated compartment design for each feeder as per 3b construction format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be separate metering compartment for incomer metering and outgoing metering can be provided in switchgear feeder also. All incomer feeders shall be provided with multifunction metering along with Phase indicating lights and other associated components such as CT, control MCB Terminal Block etc. and all outgoing feeders 100A & above shall be provided with 3 phase Ammeter along with phase indicating lights and other associated components such as CT, control MCB Terminal Block etc. The feeders above shall be provided AC accommodated all measuring instruments shall be Digital type & all indicating lights shall be LED type. Wiring shall be done from 1100V Grade PVC insulated copper flexible wire. All MCCB shall be thermal Magneetic/Microprocessor with O/L, S/C & E/F protection along with required spreaders & extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 36kA 'C' Curve.:- Outdoor type panel: Incomer feeder 200A, FP MCCB, 36 kA: Outgoing Feeders- 3No. 63A, FP MCCB 36kA.
Earthing with GI earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc. with charcoal/coke and salt as required.
Supply and laying of 25mm x 5mm G.I. strip at 0.5m below ground as strip earth electrode, including connection/ terminating with GI nut, bolt, spring, washer etc as required. (jointing shall be done by overlapping and with 2sets of brass nut bolt & spring washer spaced at 50mm).
Supplying & making end termination with brass compression gland & aluminium lugs for 150 sq.mm, 3.5 core size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1 KV grade as required.
Supply and laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade on wall surface as required. For 150sq.mm, 3.5 core
Supply and laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade on wall surface as required. For 25sq.mm, 3.5 core
Supplying & making end termination with brass compression gland & aluminium lugs for 25 sq.mm, 3.5 core size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1 KV grade as required.
Supply and laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade on wall surface as required. For 6sq.mm, 4 core
Supplying & making end termination with brass compression gland & aluminium lugs for 10/6 sq.mm, 4 core size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1 KV grade as required.
Wiring for circuit/submain wiring of 2X2.5 sqmm. alongwith 1 No. 2.5 sqmm. as earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Wiring for circuit/submain wiring of 2X4 sqmm. alongwith 1 No. 4 sqmm. as earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. For plug points
S/F of 4 ways double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess mounting complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, earth connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
S/F of 40 A rating, 4P, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F of 63 A rating, 4P, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F of 8 ways SPN double door, sheet steel, MCB distribution board, 240V, on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required but without MCB/RCCB/Isolator.
S/F of 5A to 32 A rating, 240/415V, 10kA, "C" curve SPMCB suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F of 5A to 32 A rating, 240/415V, 10kA, "C" curve DPMCB suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and Fixing of Refrigerator having Total Volume for Direct Cool 300 ltr- 3 star rated ( make model : LG Direct Cool Double Door 300 Ltr 3 Star or equivalent). complete in all respect. Model- GLT 3KTES or equivalent.
Supplying and laying of Rubber mat 1000mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as required.
Charges for dis-mentaling of old wiring, Cable, SPNDB, cut out and existing panel
stage.html
html • 0.04 MB
technical_2084889.pdf
techsummary_2084889.pdf
finance_2084889.pdf
BOQ Comparative Chart
xlsx
finsummary_2084889.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.92 MB
BOQ_2084889.xls
BOQ • 0.35 MB
Corri.pdf
PDF • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].