Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAdmitted-Finance | ₹5.0 L | L1 | Admitted-Finance |
| 2 | L2₹5.0 L+₹2,100 (0.42%)Admitted-Finance JAIN TEMPLE ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | ₹5.0 L+₹2,100 (0.42%) | L2 | Admitted-Finance |
| 3 | L3₹5.0 L+₹2,200 (0.44%)Admitted-Finance | ₹5.0 L+₹2,200 (0.44%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | H P CONSTRUCTIONS L2 | A B S CONSTRUCTION L3 | Hardware and Electrical STores L1 |
|---|---|---|---|---|---|---|
| 1.01 | Supplying, installation, Testing & Commissioning of Street light LED of 90 watt fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 160 | Each | 2,500 ₹4,00,000 | 2,510 ₹4,01,600 | 2,480 ₹3,96,800 Lowest |
| 1.02 | M&L for GI bracket for street light fittings fabricated with GI tubing 40/50 mm dia 'medium grade' 1.2 m long and bending to angle of 120degree including mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5mm with nut , bolts & washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed. | 55 | Each | 830 ₹45,650 | 820 ₹45,100 Lowest | 850 ₹46,750 |
| 1.03 | M & L for replacement of flat, twin core , PVC insulated , overall PVC sheathed solid aluminium conductor service cable of sizes 6.0 sqmm two core all as specified and directed | 950 | RM | 55 ₹52,250 | 54 ₹51,300 Lowest | 55 ₹52,250 |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
15 May 2026, 11:20 amClosed
SO-1(Wks)
Engr Branch, ARTC and School
Replacement of security lights at various Garrison boundary wall for security purpose at ARTC and S, Diphu (Assam)
2026_ARMHA_908060_1
28028/ARTCS/NIT/2026-27/02
Open Tender
Electrical Works
Works
Shokhuvi (Nagaland)
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Commandant, ARTC and School
₹10,000
23 May 2026
9 May 2026
16 May 2026
10 May 2026
15 May 2026
10 May 2026
10 May 2026 - 15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supplying, installation, Testing & Commissioning of Street light LED of 90 watt fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 160 | Each | - | - |
| 1.02 | M&L for GI bracket for street light fittings fabricated with GI tubing 40/50 mm dia 'medium grade' 1.2 m long and bending to angle of 120degree including mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5mm with nut , bolts & washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed. | 55 | Each | - | - |
| 1.03 | M & L for replacement of flat, twin core , PVC insulated , overall PVC sheathed solid aluminium conductor service cable of sizes 6.0 sqmm two core all as specified and directed | 950 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_954402.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .