Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAdmitted-Finance | ₹5.0 L | L1 | Admitted-Finance |
| 2 | L2₹5.0 LAdmitted-Finance | ₹5.0 L | L2 | Admitted-Finance |
| 3 | L3₹5.0 LAdmitted-Finance | ₹5.0 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | H P CONSTRUCTIONS L2 | A B S CONSTRUCTION L3 | Hardware and Electrical STores L1 |
|---|---|---|---|---|---|---|
| 1.01 | Supplying, installation, Testing & Commissioning of Street light LED of 90 watt fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 160 | Each | 2,500 ₹4 L | 2,510 ₹4.0 L | 2,480 ₹4.0 L |
| 1.02 | M&L for GI bracket for street light fittings fabricated with GI tubing 40/50 mm dia 'medium grade' 1.2 m long and bending to angle of 120degree including mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5mm with nut , bolts & washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed. | 55 | Each | 830 ₹45,650 | 820 ₹45,100 | 850 ₹46,750 |
| 1.03 | M & L for replacement of flat, twin core , PVC insulated , overall PVC sheathed solid aluminium conductor service cable of sizes 6.0 sqmm two core all as specified and directed | 950 | RM | 55 ₹52,250 | 54 ₹51,300 | 55 ₹52,250 |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
15 May 2026, 11:20 amClosed
SO-1(Wks)
Engr Branch, ARTC and School
Replacement of security lights at various Garrison boundary wall for security purpose at ARTC and S, Diphu (Assam)
2026_ARMHA_908060_1
28028/ARTCS/NIT/2026-27/02
Open Tender
Electrical Works
Shokhuvi (Nagaland)
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Commandant, ARTC and School
₹10,000
23 May 2026
9 May 2026
16 May 2026
10 May 2026
15 May 2026
10 May 2026
10 May 2026 - 15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1.01 | Supplying, installation, Testing & Commissioning of Street light LED of 90 watt fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 160 | Each | - | - | itemH1Code1 |
| 1.02 | M&L for GI bracket for street light fittings fabricated with GI tubing 40/50 mm dia 'medium grade' 1.2 m long and bending to angle of 120degree including mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5mm with nut , bolts & washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed. | 55 | Each | - | - | - |
| 1.03 | M & L for replacement of flat, twin core , PVC insulated , overall PVC sheathed solid aluminium conductor service cable of sizes 6.0 sqmm two core all as specified and directed | 950 | RM | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
BOQ_954402.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid