| Sl No | Description | Qty | Unit | SUNDAR ASSOCIATES L4 | AKEY ELECTRO TECHNIQUES L3 | S AND S ELECTRICALS L1 | AKSHAYA ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Successful Commissioning and Testing of LT IP55 Indoor Panel Box of size 60 Inches (W) x 60 Inches (H) x 20 Inches" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colour paint and consisting of items as mentioned in a) to g). At the bottom of the Panel, 1 x 250A, 50kA, 4P MCCB shall be fixed and existing 50-120 sq.mm UG Cable shall be terminated as Input using suitable lugs. The Output from the 250A MCCB shall be connected to 4 x 400A range Copper Bus-Bars (BB) using same rating Copper Cable / Copper BB. From the BB, inputs shall be tapped for 2 x 125A, 36kA, 4P MCCB, 3 x 63A 4 Pole, 20-36kA MCCB and to 3 x 32 Amps, 10kA, "C" Curve, 230V AC, 2 Pole MCB through 25.0 sq.mm, 16.0 sq.mm and 6.0 sq.mm FRLS Multistrand Copper Wires respectively using suitable type of lugs and standard colour code of wiring in a neatly dressed manner. A Separate Aluminium Bus-Bar for connecting the Sub-Circuits Earth Wires in the Panel and extended for 2 Inches outside the Panel on both sides, should be provided. 3 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s), Cable Alley to be made available. The panel shall have individual compartment for each MCB & MCCB within the panel. The LT Box will be fixed on the floor with total stand height of 0.75-1.5 Feet grouted to the floor. All 4 sides shall be covered suitably with removable type metal sheet (screwed to the stand) painted with same colour as of LT Box. All visible Bus-Bars inside the Panel shall be suitably covered with electrical grade insulation sheets. 6" x 6" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside. a) 400A Capacity Copper Bus Bar insulated with fire proof tape, mounted on Bus Bar Insulators - 04 Nos; b) 250A, 50kA, 4Pole MCCB - 01 No; c) 125A, 36kA, 4Pole MCCB - 02 Nos.; d) 63A, 20-36kA, 4Pole MCCB - 03 Nos.; e) 32A, 240V AC, 2P MCB - 03 Nos.; f) RYB LED Phase Indication Lamps with Fuse Unit for Input and Output - 2 Sets; g) Aluminium Earth Bus-Bar - 01 No. Important: All existing Incoming / Outgoing Cables / Wires of Main or Sub-Main Circuits shall be connected to this panel with suitable type and size Copper / Aluminium lugs. During connections, if any Incoming / Outgoing cables is / are need to be extended, as part of the work, it will be provided by CSIR-CFTRI. S.No: a), f) & g) Make: Any ISI Brand; S.No: b) to e) Make : Please refer Special Electrical Conditions under Tender Document File. Panel Design: As per Engineer In-Charge. Note: Labelling to be done for Input & Output Control Embossed in Aluminium Sheet / Paint / Acrylic Sticker . | 1 | Set | 1,65,000 ₹1,65,000 | 2,35,000 ₹2,35,000 | 1,80,000 ₹1,80,000 | 1,48,000 ₹1,48,000 Lowest |
| 2.00 | Supplying, Installation, Testing & Successful Commissioning of 36 Watts, 4 Feet LED Batten Light fitting (Bright Day Light Color) complete with internal wiring, 0.5 metre length of any standard make of rated 3 core copper wire etc.,, ready to use suitable to fix on wall / ceiling / roof and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to a 2 Way 5Amps PVC Connector. Make for All : Please refer Special Electrical Conditions under Tender Document File. | 20 | Each | 700 ₹14,000 Lowest | 750 ₹15,000 | 1,100 ₹22,000 | 900 ₹18,000 |
| 3.00 | Supplying, Installation, Testing & Successful Commissioning of IP65, 50 Watts LED focus Light fitting (Bright Day Light Color) complete with internal wiring, 0.5 metre length of any standard make of rated 3 core copper wire etc.,, ready to use suitable to fix on wall / ceiling / roof and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to a 2 Way 5Amps PVC Connector. Make for All : Please refer Special Electrical Conditions under Tender Document File. | 4 | Each | 1,700 ₹6,800 | 2,700 ₹10,800 | 2,500 ₹10,000 | 1,200 ₹4,800 Lowest |
| 4.00 | Dismantling of existing Old Bus-Bar, TPN etc., with due safety and handing over to Auction Yard. Engineer In-charge or the representative shall be present to enable to put OFF the power. | 1 | Job | 5,000 ₹5,000 | 700 ₹700 Lowest | 2,000 ₹2,000 | 2,500 ₹2,500 |
| 5.00 | Supply, Installation, Testing and Successful Commissioning of 8” x 10” Teakwood Switch Board covered with 3 mm thick hylem sheet and consisting of the following pre-wired with 6.0 sq.mm Standard Colour Code of FRLS copper wire for Phase, Neutral and 4.0 sq.mm for Earth and ready for use to fix on the wall using neccessary hardwares etc., as required.
a) 15Amps, 6 Pin Heavy Duty Flush Type Socket - 2 Nos.
b) 15 Amps Flush Heavy Duty Type Switch - 2 Nos.
c) 5 Amps Flush Type Indicator - 1 No.
d) 32 Amps DP, 10kA, 230V MCB - 1 No.
Make for All: Please refer Special Electrical Conditions under Tender Document File. | 20 | Set | 3,250 ₹65,000 | 2,800 ₹56,000 | 2,000 ₹40,000 Lowest | 2,300 ₹46,000 |
| 6.00 | Labour charges for digging 8 feet of depth below ground level, including to remove hard soil / rock / tree root etc., if any encountered, fixing the Item No:12, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:12 as required, as mentioned under S.No.12). | 5 | Each | 5,000 ₹25,000 | 6,000 ₹30,000 | 4,000 ₹20,000 Lowest | 4,000 ₹20,000 Lowest |
| 7.00 | Group A wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make for All : Please refer Special Electrical Conditions under Tender Document File. | 20 | Point | 850 ₹17,000 Lowest | 1,000 ₹20,000 | 900 ₹18,000 | 1,500 ₹30,000 |
| 8.10 | Wiring for circuit / submain wiring alongwith earth wire with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring. | 45 | Metre | 150 ₹6,750 Lowest | 225 ₹10,125 | 160 ₹7,200 | 225 ₹10,125 |
| 8.20 | Wiring for circuit / submain wiring alongwith earth wire with 2 x 6 sq. mm + 1 x 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring. | 60 | Metre | 380 ₹22,800 | 430 ₹25,800 | 240 ₹14,400 Lowest | 395 ₹23,700 |
| 8.30 | Wiring for circuit / submain wiring alongwith earth wire with 4 x 6 sq. mm + 2 x 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring. | 110 | Metre | 680 ₹74,800 | 600 ₹66,000 | 450 ₹49,500 Lowest | 650 ₹71,500 |
Tender Value
₹5.7 L
EMD Value
₹11,500
Closing Date
5 Nov 2025, 5:00 pmClosed
The Director
CSIR-CFTRI, Cheluvamba Mansion Mysuru
Provision of New Electrical Power Requirements for Shed at Old PCBT Lab at CSIR-CFTRI, Mysuru
2025_CSIR_253475_1
E/EW/006/1106/2025-26
Open Tender
Electrical Works
Item Rate
30 days
at CSIR-CFTRI Campus
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹11,500
25 Nov 2025
27 Oct 2025
7 Nov 2025
27 Oct 2025
5 Nov 2025
27 Oct 2025
27 Oct 2025 - 4 Nov 2025
Amount
Supply, Installation, Successful Commissioning and Testing of LT IP55 Indoor Panel Box of size 60 Inches (W) x 60 Inches (H) x 20 Inches" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colour paint and consisting of items as mentioned in a) to g). At the bottom of the Panel, 1 x 250A, 50kA, 4P MCCB shall be fixed and existing 50-120 sq.mm UG Cable shall be terminated as Input using suitable lugs. The Output from the 250A MCCB shall be connected to 4 x 400A range Copper Bus-Bars (BB) using same rating Copper Cable / Copper BB. From the BB, inputs shall be tapped for 2 x 125A, 36kA, 4P MCCB, 3 x 63A 4 Pole, 20-36kA MCCB and to 3 x 32 Amps, 10kA, "C" Curve, 230V AC, 2 Pole MCB through 25.0 sq.mm, 16.0 sq.mm and 6.0 sq.mm FRLS Multistrand Copper Wires respectively using suitable type of lugs and standard colour code of wiring in a neatly dressed manner. A Separate Aluminium Bus-Bar for connecting the Sub-Circuits Earth Wires in the Panel and extended for 2 Inches outside the Panel on both sides, should be provided. 3 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s), Cable Alley to be made available. The panel shall have individual compartment for each MCB & MCCB within the panel. The LT Box will be fixed on the floor with total stand height of 0.75-1.5 Feet grouted to the floor. All 4 sides shall be covered suitably with removable type metal sheet (screwed to the stand) painted with same colour as of LT Box. All visible Bus-Bars inside the Panel shall be suitably covered with electrical grade insulation sheets. 6" x 6" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside. a) 400A Capacity Copper Bus Bar insulated with fire proof tape, mounted on Bus Bar Insulators - 04 Nos; b) 250A, 50kA, 4Pole MCCB - 01 No; c) 125A, 36kA, 4Pole MCCB - 02 Nos.; d) 63A, 20-36kA, 4Pole MCCB - 03 Nos.; e) 32A, 240V AC, 2P MCB - 03 Nos.; f) RYB LED Phase Indication Lamps with Fuse Unit for Input and Output - 2 Sets; g) Aluminium Earth Bus-Bar - 01 No. Important: All existing Incoming / Outgoing Cables / Wires of Main or Sub-Main Circuits shall be connected to this panel with suitable type and size Copper / Aluminium lugs. During connections, if any Incoming / Outgoing cables is / are need to be extended, as part of the work, it will be provided by CSIR-CFTRI. S.No: a), f) & g) Make: Any ISI Brand; S.No: b) to e) Make : Please refer Special Electrical Conditions under Tender Document File. Panel Design: As per Engineer In-Charge. Note: Labelling to be done for Input & Output Control Embossed in Aluminium Sheet / Paint / Acrylic Sticker .
Supplying, Installation, Testing & Successful Commissioning of 36 Watts, 4 Feet LED Batten Light fitting (Bright Day Light Color) complete with internal wiring, 0.5 metre length of any standard make of rated 3 core copper wire etc.,, ready to use suitable to fix on wall / ceiling / roof and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to a 2 Way 5Amps PVC Connector. Make for All : Please refer Special Electrical Conditions under Tender Document File.
Supplying, Installation, Testing & Successful Commissioning of IP65, 50 Watts LED focus Light fitting (Bright Day Light Color) complete with internal wiring, 0.5 metre length of any standard make of rated 3 core copper wire etc.,, ready to use suitable to fix on wall / ceiling / roof and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to a 2 Way 5Amps PVC Connector. Make for All : Please refer Special Electrical Conditions under Tender Document File.
Dismantling of existing Old Bus-Bar, TPN etc., with due safety and handing over to Auction Yard. Engineer In-charge or the representative shall be present to enable to put OFF the power.
Supply, Installation, Testing and Successful Commissioning of 8” x 10” Teakwood Switch Board covered with 3 mm thick hylem sheet and consisting of the following pre-wired with 6.0 sq.mm Standard Colour Code of FRLS copper wire for Phase, Neutral and 4.0 sq.mm for Earth and ready for use to fix on the wall using neccessary hardwares etc., as required. a) 15Amps, 6 Pin Heavy Duty Flush Type Socket - 2 Nos. b) 15 Amps Flush Heavy Duty Type Switch - 2 Nos. c) 5 Amps Flush Type Indicator - 1 No. d) 32 Amps DP, 10kA, 230V MCB - 1 No. Make for All: Please refer Special Electrical Conditions under Tender Document File.
Labour charges for digging 8 feet of depth below ground level, including to remove hard soil / rock / tree root etc., if any encountered, fixing the Item No:12, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:12 as required, as mentioned under S.No.12).
Group A wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make for All : Please refer Special Electrical Conditions under Tender Document File.
Wiring for circuit / submain wiring alongwith earth wire with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 2 x 6 sq. mm + 1 x 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 4 x 6 sq. mm + 2 x 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Supplying and drawing 2 x 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for Wire & Pipe: Same as Item No:8. Note: All start & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Make: Please refer Special Electrical Conditions under Tender Document File.
Supplying and fixing 30A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Make: Please refer Special Electrical Conditions under Tender Document File.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. Note: Masonry enclosure size is 1.5 Feet x 1.5 Feet x 1.5 Feet. As per IS 3043, charcoal / coke and salt should be refilled with 50 Kg each per earthpit. To connect the copper flat from the bottom of the plate until funnel by using only SS nut, bolts and washers as required.
Providing and fixing 25mm x 5mm copper strip in 40mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc., as requried.
Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15mm G.I. pipefrom earth electrode including connection with copper thimble excavation and refilling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. Make: Please refer Special Electrical Conditions under Tender Document File.
Demolishing cement concrete Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-incharge.
Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tampling complete.
AKSHAYA ASSOCIATES (BID ID -923117)
AKEY ELECTRO TECHNIQUES (BID ID -923420)
SUNDAR ASSOCIATES (BID ID -922710)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
TENEW006202526.pdf
Tender Documents • 1.91 MB
BOQ_291499.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .