Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.1 Cr+₹2.1 L (1.97%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹1.1 Cr+₹2.1 L (1.97%) | L2 | Rejected-Finance Being Other than Lowest |
| 3 | L3₹1.2 Cr+₹10.0 L (9.40%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.2 Cr+₹10.0 L (9.40%) | L3 | Rejected-Finance Being Other than Lowest |
| 4 | L4₹1.2 Cr+₹16.2 L (15.1%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.2 Cr+₹16.2 L (15.1%) | L4 | Rejected-Finance Being Other than Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
7 Sept 2020, 6:00 pmClosed
CWE NW Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIRS OF OLD COFY BUILDING NO P 217 AT NAVAL DOCKYARD MUMBAI UNDER GE NW KUNJALI
2020_MES_365773_1
8377/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Rate
270 days
GE (NW) KUNJALI
Class B and above and category a i
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) KUNJALI
₹2.2 L
Yes
6 Oct 2020
31 Jul 2020
9 Sept 2020
31 Jul 2020
7 Sept 2020
24 Aug 2020
31 Jul 2020 - 21 Aug 2020
Amount
Demolition of cement concrete un-reinforced in ground floors and paving n exc 15cm thickness below or above GL complete all as specified and directed
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) n.exc 1.5 Sqm each complete all as specified and directed
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.50 but n exc n.exc 4 Sqm each complete all as specified and directed
S&F 35mm thick 2nd class HW plain framed, penelled shutter (two panel)with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of member is as specified in SSR part I supplied and fitted to chowkats complete all as specified and directed.
S&F Solid PVC door frame of size 50mmX47mm made out of 5mm single side printed PVC sheet used instead of plain colour PVC sheet (edges will be painted to match with prelam sheet) reinforced with MS square tube is as per specification complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm printed PVC sheet on back face, supplying & fixing in frame at site as per specified complete all as specified and directed.
Taking down steel tubing 15mm bore and connection, incl cleaning for refixing or removal to store complete all as specified and directed.
Taking down steel tubing 20mm bore and connection, incl cleaning for refixing or removal to store complete all as specified and directed.
supply and Fixing only 15mm bore tubes, any grade, to walls and ceiling or laying in floors including all necessary medium grade ISI marked GI fitting complete all as specified and directed.
All as per item No 09 above but fixing only
S&F 20mm dia tubes medium grade gavanised with all fittings and fixed complete to walls and ceiling or laid in floors complete incl the holes in walls and floors shall be bade by drilling with drill or jumper and not by dismantling the brick/concrete. After fixing holes shall be made good with CM 1:3 properly complete all as specified and directed.
App all as per item No 11 above but fixing only
M&L 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base of floos complete all as specified and directed
M&L for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregat) as in floor complete all as specified and directed
Dismantling of wall ceiling board (fibre, pulp, insulation, etc) or insulatin board /slab/blankes, any thickness,including cover fillets complete all as specified and directed
S&F aluminium snap grid size of 600mmX600mmframe work of 24X38X0.6mm. Tee section ( pre-coated) and 24X24X5mm thick angle alongwith the wall suspenders as per manufacturer instruction as in ceiling. (Make : Gabson eternit/Everst) including absestos free calcium Slicate designer boards 4mm thick complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L Non skid ceramic coloured tiles 8 to 10 mm thick (Square/rectrangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm, in floors etc over and including 15 mm thick cement screed bed in CM 1:6. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per item No 18 above but as on vertical surface such as skirting, dados and risers over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed
M&L Non skid ceramic coloured tiles 7 to 8mm thick (Square/ rectrangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc over and including 15 mm thick cement screed bed in CM 1:6. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L Glazed ceramic cloured tiles in vertical surface size of each tiles 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement with admixture or pigment to match the shade of granite stone including grinding and polishing complete over and including 15mm thick cement screed bed in CM (1:6) complete all as specified and directed
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar sitution complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar mortor incl all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
M&L for Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed
Taking down cement plaster on brick work or stone walls, etc incl raking out joints, hacking for key, scrubbing down with water, complete all as specified and directed
M&L for rendering 15 mm thick on brick masonry surface or surface other than fair face of brick-work in CM ( 1:6) and finished even and smooth with out using extra cement complete all as specified and directed
M&L for rendering 15mm thick on fair faces of brick masonry surface with water proofing compound @ 2% by weight of cement and finished surface even and smooth with out using extra cement in CM (1:4) (wpc compound paid seprately) complete all as specified and directed.
Dismantling of wall panneling,partation or insulation boards, bonded wool, blanket slab incl aluminium grid frame work complete all as specified and directed
S & F Powder coated aluminium frame for partation /Windows/Doors with all necessary fittings with one or more rebates including joining cleat for fixing complete all as specified and directed
S&F in repairs for aluminium anodised Deco grill 7.5 mm size DG-102, fixed to E/H frames, 1.5mm thick, bar size 6.2mm and 7.5mm thick in required sizes complete all as specified and directed
S&F 12mm thick, toughened glass for door shutters, partitions, shelves etc with and including fitting and fixtures such as glass handles stainless streel studs, fittings for door pivots complete all as specified and directed
S&F 12 mm thick pre-laminated Medium Density board with both side decorative lamination interior grade,fixed in aluminium/ wooden frame work complete all as specified and directed.
M&L 19mm thick plywood,grade BWR, type BB, fixed with screws complete all as specified and directed
M&L 12mm thick plywood grade BWP, type BB fixede with screw to timber frame work complete all as specified and directed
M/L 0.9 mm thick Decorative texture finish laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S & F in repairs 3 mm thick Aluminium composite panel cladding plain metallic of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour & Aluminum tubular hallow section 25 x 25 mm not exceeding 900 mm c/c on exceeding col/beam/ slab to hold APC cladding complete all as specified and directed. (Note:- Colour/ Pattern of ACP sheet shall be given by GE)
M&L for double action floor spring hydraulically regulated made up of minium 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as per manufacturer's instruction complete all as specified and directed.
S&F 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed on door shutter complete all as specified and directed
S&F 100mm butt hinges meadium weight cold rold, mild steel and fixed complete all as specified and directed
S&F 200mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
M&L in repairs for 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
M&L in repairs 3mm thick sheet float glass, ordinary quality and glazing with oil putty or beads in square n exc o.5 sqm in each pane all as specified and directed.
M&L in repairs Stainless steel wire cloth. 0.36mm nominal dia or wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed
S&F 20mm bore PVC coated MS conduit drapery rods, suitable for door/widows curtain with fancy type dooms as approved by GE, and fitted to each end, incl necessary brackets and fixed to wall complete all as specified and directed
M&L 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in kitchen cabinet boxes complete all as specified and directed.
Extra over rates of block board or veneered particle board for external teak wood lipping, 6mm thick, fixed with nails for 18/19mm thick prelaminated boards all complete all as specified and directed
S&F continuous (piano hinges, mild steel, bright finish or electrogalvanished width of flaps (when opened) 40mm complete all as specified and directed
S&F in repairs Ball catches with 8mm dia steel ball, and brass body and striking plate incl letting in and fixed complete all as specified and directed
Cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting n exc 10cm girth. pinning in, making good to facings where required and pointing in CM 1:3 on stone walls complete all as specified and directed
S&F in repairs 15mm bore bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed (weight not less than 400gms) complete all as specified and directed
S&F in repairs 15mm bore stop cock (Concealed type) CP fancy type with, screwed down, high pressure for iron pipes or for unions (weight not less than 400gms) complete all as specified and directed
S&F in repairs CP pillar tap cast copper alloy chromium plated fancy type high pressure with or without lettered hot or cold with long screwed shank and fly nut screwed for iron pipe 15mm dia fancy type (weight not less than 400gms) complete all as specified and directed.
S & F in repairs white vitreous china washed down water closet pan, (pedestal pattern), white, with and including P/S rrap, PVC solid type seat cover complete all as specified and directed
S&F in repairs vitreous china wash basin, oval shape, white, size 550 X 400mm incl brackets or beding in cement mortar to wall complete all as specified and directed
M&L in repairs 32mm dia waste coupling, PTMT for glazed ware sinks, basin, etc with long shanks and fly, flange end complete all as specified and directed
S&F in repairs 10 ltrs capacity PVC low level flushing cistern valve less white or coloured with intel, bal valve floot and handle incl brackets complete all as specified and directed
S&F in repairs PVC connection on pipe 450mm long with brass nut bolt complete all as specified and directed
S&F in repairs PVC waste pipe 32mm dia 800mm long with socket suitable for WHB/Sink complete all as specified and directed
Dismantling of 75mm or 100mm dia cast iron or reinforced cncrete drain pipes, jointed in cement mortar and taking out of trenches if required complete all as specified and directed
S&F in repairs 75mm dia of out let cast iron floor trap with grating including jointing to waste pipe in cement concrete tybe B-1 (1:2:4) complete all as specified and directed
S&F in repairs PVC (SWR) Pipe single socketed in any length with rubbering joints laid in trenches or in floor for 110mm dia complete all as specified and directed
All as per item No 63 above but 75mm dia
S&F PVC (SWR) Pipe single socketed in any length with rubber joints 110mm dia fixed to walls with clamp complete all as specified and directed.
All as per item No 65 above but 75mm dia.
S&F PVC Bends any redius 110mm dia provided with axcess door complete all as specified and directed
All as per item No 67 above but 75 mm dia all as specified and directed.
S&F PVC in repairs (SWR) Junction single T equal or unequal 110mm dia provided with eccess door complete all as specified and directed
All as per item No 69 above but 75mm dia complete all as specified and directed
S&F in repairs Brass chromium plated tubular towel rail 600mm long between flanges, 20mm dia, D type complete all as specified and directed
M&L 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate incl finished even and smooth with using extra cement as in plinth protection incl necessary form work to edges complete all as specified and directed
M&L Two coats of synthetic enamal paint over a coat of pink primer on newly wood/wood based surfaces over 10cm width or girth incl preparation of new surface complete all as specified and directed.
M&L One coats of synthetic enamal paint on old painted wood/wood based surfaces over 10cm width or girth incl preparation of old painted surface complete all as specified and directed
M&L Two coats of synthetic enamal paint over a coat of red oxide primer on steel surfaces over 10cm width or girth incl preparation of new surfacescomplete all as specified and directed
M&L One coats of synthetic enamal paint on old painted steel surfaces over 10cm width or girth incl preparation of old surfaces complete all as specified and directed
M&L for complete removal of new treatment of walls and applying two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on new wall/roof surfaces after preparation including scaffolding complete all as specified and directed
M&L for complete removal of existing treatment of walls and applying two two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof including scaffolding complete all as specified and directed
M&L for machine pressed pre-cast concrete interlocking coloured paver block and shape and size conforming to IS-15658-2006 of 80mm thickness M-40 grade with grey cement and pigment laid dry over 50 mm thick stone dust or sand base and compacted using vibrator complete all as specified and directed
Dismantling of water tanks and removing to stores all as specified and directed.exc 500 Litre but not exc 1000 Litre
Supply and fix Rotational moulded polyethylene water storage loat tanks (cubical in shape close top) capacity 375 ltrs hoisted and fixed in position complete all as specified and directed
M&L for two coat of oil bound distember over a coat primer over 3mm thick of birla white putty including preparation of newly plastered surface complete all as specified and directed
M& L for complete removal of existing treatment and applying one coat of Oil bound distemper over 3mm thick birla white putty including preparation of surface complete all as specified and directed
Dismantling of asbestos cement (Corrugated, semicorrugated etc) sheets including ridge in roof coverings complete all as specified and directed
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F 4 mm thick Polycorbonate roof sheeting of required profile with self taping screws as in roofing complete all as specified and directed
Dismantling wrought or mild steel work of any description complete all as specified and directed
S&F mild steel framed work such as in frames of gates, grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, framed balusters, walk ways, railings, framework of water tank and similar work con-forming to Fe-290. Gde E-165 complete all as specified and directed
Demolition and complete removal of existing water proofing treatment of any description in any position including cleaning, wire brushing, watering, removal of deris upto 1500 mtr distance complete all as specified and directed
M&L PCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope complete all as specified and directed
M&L for roof treatment by application of two coats elastomeric coating of "TECH O THANE PU-White" @ 1.5kg/SQM in CHOWKSEY CHEMICALS or NITROPROFF600 PF @ 1.5 KG/sqm in FOSROC or equivalent in IWL etc with DFT of minimum 1 mm thickness on primed surface by using special grade of "Primer PR 71" in CHOWKSEY CHEMICALS OR NITOPROFF Primer in FOSROC" complete all as specified and directed. (a) Rate should be inclusive of removing and refixing the lightening arrestor if existing. (b) Rate should be inclusive of removal and refixing PVC water tanks or shifting or any
M&L for cement concrete tiles 25Cmx25Cmx22 mm thick, machine pressed, (with grey cement & pigments) set jointed and pointed in neat cement slurry in floors over and including 15mm thick bedding layers in CM 1:3 complete all as specified and directed
M&L for water proofing plaster for sunken prtion in CM1:3, 15 mm thickin two coats using Pidiproof LW +Water proofing chemical of Dr. Fixit or equivalent as per manufacturer's instruction and finishing the surface even and smooth without using extra cement complete all as specified and directed (water proofing Chemical shall be measured and paid separetely).
M&L for water proofing treatment of sunken floor/wall surface by applying two coats of elastomeric coatings of BRUSHBOND RSX in FOSROC or TECKFORCE 2K STRONG in CHOWKSY CHEMICALS as a two component flexible elastomeric coating with mimimum 2mm thickness layer complete as per manufacturer's instructions complete all as specified and directed
Removal of debries, old concrete, spoils etc exc.5 Km outside MD land complete all as specified and directed.
Providing and erecting at site self supported steel H- Frame Scaffolding for structural repairs of buildings with cross bracings of good quality without dents and corrosion to reach place of work including approchases, extension , working platform ladders, lifting tackel necessary wall anchores for men and materials till completion of all structural repair items of work and curring period. complete. The work should be caried out with all the safety belt and adequate labour insurance under the supervision of qualifed supervisor this item should be used only for structural repair work for entire period of building complete all as specified and directed. (Payment should be only once irrespective of duration of scaffolding.)
Carefully tapping with light hammer the hollowness / De-bonded plaster and chipping the same with chisel after demarking and cutting the boundary grooves by electric cutting machine including removal of debris complete all as specified and directed.
Breaking carefully the loose concrete of distressed member without damaging existing strong concrete by means of sharp chisel which should tempered regularly of high frequency low impact hammer is used, cleaning the surface by water jet pressure pump at 4 to 5 kg/ sq.cm pressure to remove chlorides and loose partials, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labor insurance under the supervision of qualified supervisor. (The damaged ceiling / concrete will be measured) complete all as specified and directed
Providing and erecting steel tubular props of required height up to 14' feet, L head or flat head braced at center and supporting a continuous 2"X 3" wooden runner , resting on wedge and block minimum capacity 3 Ton to support the structure provisionally during repair and jacketing etc. and maintain them in position till required item complete. The props are erected in perfect vertical in plumb taking /transferring the load equally/ uniformly. The location of every prop should be one over another floor and it should not be eccentric. The tightening of every prop should be uniform to all props to strain the building uniformly, removing the same as and when directed by site Engineer. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor and remove the same completion of work complete all as specified and directed
Cleaning the existing reinforcement with hammer tapping and wire Brush/ rotary wire brush , fixed to hand drill machine, making the surfaces free form loose corrosion material, dirt scaling complete. Applying two coats of polymer based alkaline rust converting primer confirming to ASTM-B 117 by means of paint brush, liberally all over in two coats of 1 hour between the coats, The product should converts the rust in to stable organo metallic complex molecule layer, this should also act as primer to further treatment of steel . The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor. (the damaged area celling/ concrete to be measured) complete all as specified and directed
Anticorrosive treatment to Reinforcement application of two coats of IPNETRB (CBRI known how) on expose reinforcement in two coats with time interval) of minimum 4 hours between each coat. The application shall be by brush, Application is allowed to dry for further treatment. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damaged area ceiling / concrete to be measured) complete all as specified and directed
Providing and applying two coats of concrete penetrating hi- tech corrosion inhibition mechanism inhibits corrosion of steel in concrete at the poles, cathode & anodic simultaneously on concrete surface which is prepared earlier. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damaged area ceiling/ concrete to be measured)
Supply and pour the free flow ready mix micro concrete mix with water in the form work. Micro concrete should be mixed in steel tray homogeneously makeup concrete is based on types of structural element and its location. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor complete all as specified and directed
Providing and applying 15 mm thick polymer mortar to load carrying R.C.C member in two layers in proportion of 1:5:15 by weight polymer of approved quality and make, cement and wash quartz sand with required W.C. ratio for desired floating, curing after initial setting time complete all as specified and directed
Making up lost section of concrete / mortar with thixotropic repair mortar is one component thixotropic dual shrinkage compensated fiber reinforcement formulation for structural members. Build up section by hand packing as per manufacturers specification, applied by mean of hand glouse by expert applicator, the rehabilated surface should be free from air gaps, voids should be in line with existing required line and line with existing surface, including curing, cleaning the area etc. complete. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor complete all as specified and directed
Providing and Fixing Shear connectors of 8mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing Cylinder-in-cartridge form that avoids site mixing using standard sealant applicator gun after drilling holes of 12mm diameter to a minimum depth of 100mm at required locations, inclusive of all material, manpower and equipment.complete all as specified and directed
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Providing and applying approved epoxy resin EPI Bond of Krishna conchem or equivalent before polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C- 882-87 using nylon brushes scaffolding labour
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method complete all as specified and directed
M&L for Drilling and fixing Teflon perforated nozzles in RCC member, including drilling 14 mm dia. 50 to 100mm deep holes in structural members at an intervals of 600 mm in staggared manner of as directed by the Engineer in Charge Clean the holes by air blower prior to fixing nozzles. fixing of nozzels in cleaned holes. external end of nozzles to be machined to receive outlet of grouting gun. nozzel is fixed by means of epoxy by means of epoxy sealent to ensure complete sealing . cure the system for min. 12 hours. the work should be be carried out with all the safety measures like like helmet, safety belt and adequate labour insurance under the supervision of qualifed supervisor.complete all as specified and directed
Providing and Injecting the fixed packer two-component low viscosity (<350 cps) epoxy resin system that achieves compressive strength in excess of 55 MPa at 1 day & 65 MPa at 7 days. and shall exceed 15 MPa in slant shear bond strength with minimum pot life of 30 minutes at ambient temperatures complying with ASTM C881, Type 1 & 4, Grade 1, Class B &C using any of the standard pressure grouting methods at a maximum pressure of 2kgs/sq.cm. till refusal and allowing the epoxy grout to cure before removal of packers inclusive of cost of Material, Manpower and Equipment.
Providing and Injecting high performance non shrink, free from high strength antiwash Polymer Cement Grout of Krishna Conchem or equivalent by addition of water as per manufacturers specification into hoeycombing area/ porous concrete including drilling of holes minimum 50 mm in concrete, fixing nipples, injecting grout by suitable pump at pressure of 2.0 kg/cm2 and subsequently cutting/ removal of nipples and sealing of holes with epoxy putty EPW 1010 complete all as specified and directed
Use and waste form work to sides of columns etc fair finished surfaces complete all as specified and directed
Use and waste form work to chajjas etc rough finished surfaces complete all as specified and directed
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, n exc 200mm thick (horizontal or sloping), fair finished surfaces complete all as specified and directed
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces complete all as specified and directed
Taking down old U/S tube light fittings single / Twin ,Recessis mount fitting , etc and making good the distrubed surface matching with existing surface complete all as specified and directed
Taking down old u/s Main switch/Distribution Boxs of any type and capacity including MCBs, MCCBs and Isolation from wall/ceiling etc & making good to the disturb surfaces complete all as specified and directed
Taking down carefully sub main wiring of any size including batten/ conduit by unscrewing from wall,ceiling and making good surfaces to match with original status complete all as specified and directed
M&L point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly complete all as specified and directed
One light point controlled by one 5A switch
One Fan point controlled by one 5A switch
One Exhaust fan point controlled by one bell push
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring complete with 4 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 4Sq. mm as earth continuity conductor connected to common earth dolly for15 amp swich socket on independant board complete all as specified and directed
S & F in replacement of Switch piano flush type single pole one way ,5/6 Amps complete all as specified and directed
Supply and fix switch sockets combination 5 pin 5 Amps flush type 240 Volts AC complete all as specified and directed
Supply and fix in replacement switch socket combination multi purpose 3 pin 15 Amps controlled by one switch flush type 240 Volts AC complete all as specified and directed
S & F in replacement of fan regulator electronic step type socket size and making all necessary connections complete all as specified and directed
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal 240 volts, 5 Amps complete all as specified and directed
S & F in replacement 20 Amps Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. Make Legrand Cat part no -507814 , or equivalent in siemens ,GE
S &F 20 Watt 4 FT LED tube light fitting integrated Batten T5: Nakshatra series indooor light decorative alluminium extruded T5 LED Batten-integrated type complete all as specified and directed. Make- C & S CAT PART NO LTTB4F20WLED/W,OR Equivalent in Havells/ Wipro/CG
S & F in replacement of MCB SP 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make- Legrand/Siemens/GE
S & F in replacement of MCB,SPN 40 Amps capacity, C Curve type suitable for 240 volts AC supply over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make-Legrand,siemens,GE
S & F in replacement of MCB,SPN 63 Amps capacity, C Curve type suitable for 240 volts AC supply over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make-Legrand,siemens,GE
S & F in replacement of MCB, TPN, 63Amps capacity, C Curve type suitable for 415 volts AC supply over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make legrand Cat Part no-408702 Equivalent in Siemens,GE
S & F distribution Board SPN 8 Way 240 Volts double door, prewired type, made out of CRCA sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators complete all as specified and directed. Make - Legrand cat No 607731 or equivalent in siemens/GE.
S & F in repair Distribution Board TPN 4 way, 440 volts double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s complete all as specified and directed. Make - Legrand cat part no 607735 or Equivalent in siemens
S & F LED Street light 48 Energy Saving and Environment friendly light fitting with 24 nos LED Light source 4800 lumens with electronic gear housed in Pressure diecast alluminium alloy LM6 with IP65 protection operating volt up to 265 volts complete all as specified and directed. Make - Havells cat part ENDURA CITYLINER NEO 48W/ LED
M & L submain wiring with two run 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI marked drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one run PVC insulated & unsheathed multistranded copper conductor 4Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed. Note :- 3 runs of 4 sqmm cable and one run of PVC casing and capping will be meaured as one meter
M & L Submain wiring with two run 6 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI makrked drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one PVC insulated & unsheathed multistranded copper conductor 6.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed. 3 runs of 6 sqmm cable and on run of PVC casing and capping will be meaured as one length
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 25 Sq mm laid in duct / along pole/wall including making connection complete all as specified and directed Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed
Garima Construction Co
Shree Ayyappa Engineering
M/s S.D Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .