Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
3 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (AF) Chabua
GE (AF) Chabua
REPAIR / MAIN OF WATER SUPPLY AND ALLIED WORKS, INTERNAL WIRING, LIGHT FTGS, DBs, GEYSERS, CEILING FAN, EXHAUST FAN, STREET LIGHTS, PERIMETER LIGHTS, RUNWAY LIGHTS, HIGH MAST LIGHTS, DG SETS, PERIMETER UG CABLE ETC AT ALG PASIGHAT UNDER GE(AF) CHABUA
2026_MES_793479_1
851
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Chabua
As per tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Chabua
₹86,000
Yes
12 Oct 2026
12 Oct 2026
10 Nov 2026
12 Oct 2026
3 Nov 2026
27 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (if required), complete all as per specified and as directed by Engineer-in-Charge.
Note: - (a) Cost of spares and accessories will be measured and paid seperatly under relevent items.
(b) Cost for taking down and re-fixing of street lights shall be deemed to be included in the unit rate quoted.
(c) Any other items or parts (other than listed in Sch A) required for smooth functioning of street lights/ Security lights on pole from junction box busbar to street light shall be provided by the contractor and rates for the same are deemed to be included in above item here in before nothing extra shall be paid on this account.
(d) All the fitting of HPSV/ HVMV LED street light/ flood light will be cleaned once in a month or when required.The rates for which shall be deemed to be included in the unit rate quoted. | 119 | Per Complaint | 100 | ₹11,900 |
| 2 | Supply and fix in repair LED driver suitable for 45 watt LED street light fitting complete all as specified and directed. | 5 | Each | - | - |
| 3 | Supply and fix in repair LED driver suitable for 60 watt LED street light fitting complete all as specified and directed. | 5 | Each | - | - |
| 4 | Supply and fix in repair LED driver suitable for 70 watt LED street light fitting complete all as specified and directed. | 5 | Each | - | - |
| 5 | Supply and fix in repair LED driver suitable for 90 watt LED street light fitting complete all as specified and directed. | 5 | Each | - | - |
| 6 | Supply and fix in repair LED driver suitable for 100 watt LED street light fitting complete all as specified and directed. | 5 | Each | - | - |
| 7 | Taking down old unsv UG cable of size 16 sqmm x 4 cor complete all as specified and as directed at site. | 500 | RM | - | - |
| 8 | Supply and laying in trenches or drawn through pipe or fixed on wall/poles, LT UG cable heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 16 sqmm x 4 core complet all as specified and as directed at site. | 500 | RM | - | - |
| 9 | Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed. | 183.94 | CUM | - | - |
| 10 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed. | 147.76 | CUM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_889847.xls
BOQ • 0.38 MB
generalpage.pdf
Tender Documents • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .