Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC NO 98 MARAPPA ROAD 1ST CROSS NAGAYANA PALYA M S NAGAR POST BANGALORE 560 033 | BENGALURU URBAN | KARNATAKA | 560033 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.0 L+₹2.8 L (16.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.9 L+₹4.8 L (27.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.0 L+₹4.8 L (28.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹23.8 L+₹6.6 L (38.7%)Rejected-AOC NO 71 1ST CROSS MUNESWARA BLOCK PALACE GUTTAHALLI BANGALORE 560 003 | BENGALURU URBAN | KARNATAKA | 560003 | L5 | Rejected-AOC L5 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
DE-SLUDGING OF SEPTIC TANKS, CLEANING OF SEWAGE LINE MANHOLES, REPAIR/ REPLACEMENT OF SEWAGE LINES, MANHOLES, SEPTIC TANKS AND CONNECTED WORKS AT DOMESTIC AREA AT AF STATION YELAHANKA
2024_MES_669855_1
8286/E8
Open Tender
Civil Works
Item Rate
330 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹44,000
Yes
19 Oct 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Cleaning of blocked / chocked Nahani trap / floor trap/WC/ Wash basin/, including drain / sewer / sewage line of any description (SGSW / RCC / CI pipe/SWR Pipe) of 75mm/100 mm / 150 mm / 200 mm dia and any depth by rodding or by mechanical means and well flushing the complete drain / sewer line upto first manhole to the entire satisfaction of Engineer – in - charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed. Note (i) : Contractor or his supervisor /site Engineer will report daily at 0900hrs at complaint cell for collection of complaints from the concerned JE in -charge, in case after checking & attending the complaints, if it is not possible to rectify the defects within 08 hrs, the facts shall be brought to the notice of JE than after charge is satisfied with contractor's view, no recovery will be made on this account. However complaints related to sewage line blockage / pipe replacement etc whatever is applicable shall be attended on same day whether it is 'Sunday" or "Gazetted Holidays" and nothing extrea shall be payable to contractor on this account. Note (ii) : Contractor or his supervisor / site engineer will report daily at 0900 hrs at complaint cell for noting of day to day complaints in complaint register, issue of complaints slip to tradesman and enter after completion in complailnts register as instructed by JE,s. In case of absence of contractor rep for noting complaints, a penalty of Rs 1000.00 per day will be deducted from the contractor bill. Note (iii) : The complaint shall be attended & defects shall be rectified within 08 hrs i.e. from 0900 hrs to 1700 hrs excluding Sundayor gazetted holiday, commencing from date and time of notifying the complaint slip failing which a Penalty @ Rs. 500/- Per complaint per day (08 hrs) shall be levied upon/ imposed on the contractor and necessary recovery shall be made from his dues on this account. Note (iv) : The above all aspect shall be deemed to be included in this quoted rate.
Cleaning of manhole to manhole, using high pressure water jetting machine, including cleaning/ clearing blockages with all tools and labours as per the site requirement pipe size 150 mm and over including man holes through chasis mounted Diesel run vehicles mounted hydraulic operated high pressure suction cum geting sewer cleaning machine KAMBI-10 LCHB fitted with imported international standard pumps having minimum of 3000 litres to 4500 litres sucking capacity including skilled operator supervising engineer for cleaning/partial desiliting of manholes and sewer line as per guide lines laid in IS -11972 (1987) and complete cleaning of site all as directed by Engineer in charge - Note :- (a) Jetting of sewer line by high pressure jetting system of 2200w PSI/Suction. (b) The complaint has to be rectified with in 24 hrs from the complaint assign to the contractor failing which penalty will be imposed @500/- per complaint per day.
M&L for de-watering /de sluding of sewge well and septic tank of any size & approx 2 to 3 metre depth ,excavation of waste water from collection tank using 4500 litres to 5000 litres vaccum suction tanker, De watering of liquid or semi liquid waste by water sucking hydraulic pressure machine including cleaning of all sludge silt residue of both organic nature by manual labour or by mechanical scrappers etc in any position & disposal off all the waste outside the defeneland the de-sludging of sewage sump is to be carried out upto the bottom slab of sewage sump/ sewage well complete. The sewage well wall & bottom slab to be cleaned by water with high presurre up to entire satisfaction of Engr-incharge , neccessary safety precaution to be adhere during working. Note :- (a) Jetting of sewer line by high pressure jetting system of 2200w PSI/Suction. (b) The complaint has to be rectified with in 24 hrs from the complaint assign to the contracor failing which penalty will be imposed @500/- per complaint per day.
Taking off existing manholes covers & cleaning of manholes depth up to 2 metre by de-watering and taking off the rubbish / sludge etc., removing the same up to 50 m distance and put into newly excavated pits of suitable size and covering with excavated earth and placing back in position the removed covers complete all as specified and directed.
Taking off existing manholes covers & cleaning of grease pit (any type) not exceeding 3 metre depth by de-watering and taking off the rubbish / sludge etc., removing the same up to 50 m distance and put into newly excavated pits of suitable size and covering with excavated earth and placing back in position the removed covers complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime moratr including all quoins, arches, pillars, etc but excluding ashlar facings dressed stone work and prcast concrete articles complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks of type C1, 1:3:6 (using 20 mm grared stone aggregate), exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
Brickwork with sub class ‘B’ bricks of old size, straight or curved on plan exc 6 m mean radius built in CM 1:4 completed all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M & L for providing factory made pre-cast cement concrete cover slabs (As required sizes) for manholes, and similar items with angle iron edging and plain faces in cement concrete M-30 including neccesry reinforcement complete all as specified and directed.
Demolition and breaking up drain pipes internal dia of pipe in 150mm (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as directed.
Demolition and breaking up drain pipes internal dia of pipe in 200mm (salt glazed ware, AC or reinforced concrete ) set in cement mortar complete all as directed.
M&L for 150mm dia reinforced concrete pipes class NP-2 laid and jointed complete with collars all as specified and directed.
M&L for 200mm dia reinforced concrete pipes class NP-2 laid and jointed complete with collars all as specified and directed.
M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) for 150mm dia pipe concrete bed to drain pipes of including packing under and haunching against the sides of pipe after they are laid and tested including necessary form work for the following bore of drain complete all as specified and directed.
M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) for 200mm dia pipe concrete bed to drain pipes of including packing under and haunching against the sides of pipe after they are laid and tested including necessary form work for the following bore of drain complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded crushed stone aggregate), as in benching, coping, channel of manholes and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for cutting into existing manhole for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm dia pipe complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors/wall complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors/wall complete all as specified and directed.
S&F in repair PVC (SWR) gully trap of size 125/110 mm setting and jointing with solvent of cement complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl of size 75mm dia including taking down old unsuitable vent cowl complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl of size 110 mm dia including taking down old unsuitable vent cowl complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) bend any radius all as specified and directed.
S&F in repair 75mm dia PVC (SWR) bend any radius all as specified and directed.
S & F in repair 110mm dia PVC(SWR) single T all as specified and directed.
S & F in repair 75mm dia PVC(SWR) single T all as specified and directed.
S&F in repair 110mm dia PVC(SWR) branch pieces single (Single Y) equal or unequal all as specified and directed.
S&F in repair 75mm dia PVC(SWR) branch pieces single (Single Y) equal or unequal all as specified and directed.
M&L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent of cement in repairs complete all as specified and directed.
S&F in repairs vitreous China squatting pan 'orrisa' pattern white colour of size 580x440mm with integral foot rests including provision of lime concrete complete all as specified & directed by Engr-in-charge. Make : Cera/Jaguar/Ess Ess
S&F in repairs Grating dome 100 mm dia stainless steel with or with out hole all as specified.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soft / loose soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
JITHU CONSTRUCTION COMPANY (BID ID -3106017)
GOVINDARAJU INTERIOR DECORATION (BID ID -3106484)
SRUSHTI CONSTRUCTIONS (BID ID -3107641)
Lakkaiah Rangaswamy (BID ID -3120523)
SRI AYYAPPA ENTERPRISES (BID ID -3122096)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .