Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | ₹40.0 L Quoted ₹41.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹42.2 L+₹89,727.69 (2.17%)Rejected-AOC | ₹42.2 L+₹89,727.69 (2.17%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹42.4 L+₹1.1 L (2.73%)Rejected-AOC GROUND FLOOR 281 1 D SHIVRAI NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | ₹42.4 L+₹1.1 L (2.73%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹43.2 L+₹1.9 L (4.61%)Rejected-AOC NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | ₹43.2 L+₹1.9 L (4.61%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹43.7 L+₹2.4 L (5.80%)Rejected-AOC FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | ₹43.7 L+₹2.4 L (5.80%) | L5 | Rejected-AOC Being L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Jun 2025, 6:00 pmClosed
GE RnD Pashan
GE RnD Pashan
REPAIR AND MAINTENANCE TO EXTERNAL ELECTRIFICATION, UG CABLE, LT PANELS INCLUDING OTHER CONNECTED WORK AT DRDO ESTATE UNDER GE(I) RnD PASHAN
2025_MES_707949_1
GERD/PSN/TOKEN/06 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE RnD Pashan
As per tender documents
9 documents required · 9 mandatory
₹500
GE RnD Pashan
₹90,000
Yes
17 Jul 2025
13 May 2025
5 Jun 2025
13 May 2025
3 Jun 2025
27 May 2025
13 May 2025 - 20 May 2025
Amount
Taking down Insulators any type any description and depositing/ shifting to store for safe custody or issue under schedule of credit complete all as specified and directed.
Dismantling and taking down guarding wire and depositing/ shifting to store for safe custody or issue under Sch of credit complete all as specified and directed.
Taking out steel tubular swaged poles upto 11 metre long and depositing/ shifting to store for safe custody or issue under schedule of credit complete all as specified and directed.
Dismantling and taking down HT OH line conductor and depositing/ shifting to store for safe custody or issue under schedule of credit complete all as specified and directed.
Dismantling cross arms / MS channel from HT pole including clamps, nuts, bolts & washers complete all as specified and directed
Supply and fix Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade complete all as specified and directed.
Supply and fix insulator shackle type, porcelain, vitreous, white, brown or green insulator including galvanised and mild steel straps of size 31x5mm, washers, insulator bolts, washers and nuts, size of insulator 100 mm height, 115 mm dia with 14 mm dia bolts for 1100 Volts grade complete all as specified and as directed.
Supply and fix Polymer Pin type insulator of 22 KV including necessary hardware complete all as specified and directed.
Supply and fix Polymer disc type insulator, ball and socket type, white brown or green suitable for 22KV including necessary hardware complete all as specified and directed.
Material and labour for Cradles, hexagonal / rectangular, fabricated with galvanised steel wire 3.15 or 4 mm complete all as specified and directed.
Supply and fix HT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 11 metre long complete all as specified and directed. Note : Earth work will be measured and paid separately
Material and labour for aluminium conductor steel reinfoced for over head line, fix on pole bringing the sag with in limit, fixing to the insulator by means of necessary binding with 14 SWG aluminium wire complete all as specified and directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size fixing to existing pole and inclusive of one primer coat, one under coat and one finishing coat of paint as indicated or complete all as specified and directed by Engineer-in-Charge.
Repair and overhauling to gang operated air brake switch device upto 400 Amps,22 KV capacity including use of petrolium gelly for smooth functioning of all moving contacts of GOD complete all as specified and directed. Note : (i) Contractor shall provide all safety tools like HT hand gloves, ladder, rope, safety belt, helmet etc, T&P meggar, earth tester and other necessary tools required at site. (ii) Spares required to be replaced shall be measured and paide separately as "Supply only" and fixing charges for the same is deemed to include in the rates quoted for the items.
Supply only Male contact/moving contact with blade arcing hornof gang operated AB switch devices suitable for 22 KV complete all as specified and directed
Supply only Female contact /fix contact jaw arcing horn for gang operated AB switch devices complete all as specified and directed.
Supply only Tinned copper flexible jumper 400/200 Amps of suitable length
Supply only Post top Polymer insulators of gang operated AB switch devices complete all as specified and directed
Supply only Middle post Polymer insulators of gang operated AB switch devices complete all as specified and directed
Supply only Bottom post Polymer insulators of gang operated AB switch devices complete all as specified and directed
Supply only MS jumper carrier complete all as specified and directed.
Supply only GI pipe, heavy grade 25 mm dia made to shape for gang operating from ground complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LT under ground cable and getting out in the following type of earth stata complete all as specified and as directed:- Soft / Loose Soil
Hard/ Dense Soil
Soft/ Disintegrated rock
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for riddled earth filling in trenches to required width at bottom and top of cable as cushioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall only measured and paid.
Supply and lay in trench reinforced precast concrete semi round cable cover of size 1000 x 150 x 32mm for HT cable protection complete all as specified and directed by the Engr-in-charge
Material and labour for GI tube, , light grade with necessary fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed for the following size of pipe. Note : Excavation and earth work where required shall be measured separately. MS Clamps for fixing on wall / pole , etc are included in the unit rate. 100 mm dia bore
80 mm dia bore
40 mm dia bore
Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 95 Sq mm HT XLPE shielded core type wrapped with galvanised steel strip armoured (earthed), PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete including taking down existing unserviceable cable all as specified and directed. Note: Earthwork, cushioning and cable covers will be measured and paid separately.
Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 185 Sq mm HT XLPE shielded core type wrapped with galvanised steel strip armoured (earthed), PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete including taking down existing unserviceable cable all as specified and directed. Note: Earthwork, cushioning and cable covers will be measured and paid separately.
Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 sqmm,22 KV including taking down existing unserviceable joint complete all as specified and directed by Engineer-in-charge.
Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,185 sqmm,22 KV complete including taking down existing unserviceable joint all as specified and directed by Engineer-in-charge.
Material and labour for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, up to 3 core, 185 sqmm 22 KV including taking down existing unserviceable joint complete all as specified and directed by Engr-in-charge.
Material and labour for indoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, up to 3 core, 185 sqmm , 22 KV complete including taking down existing unserviceable joint all as specified and directed by Engr-in-charge.
Cutting the tree branches which touches the LT/HT OH lines and 2.5 mtr away from centre line of HT/LT OH line span not exceeding 60 metre between poles and deposting the tree branches/leaves at 30 metre distance away from site.complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one length for payment purpose.
On load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap of sphere of oil testing by machine complete all as specified and directed. Note: .Oil samples are to be collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration to be deposited to AGE E/M office for records.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various capacity installed in various locations complete all as specified and directed. Make of Transformer oil: Savitha/ Poweroil/ HP Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer.b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply & Fixed in repair breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Repairs to drop out fuse complete of upto 400 Amps,22 KV capacity including replacement of worn out nut bolts,washers,of suitable size /unserviceable spares and jumper connections for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares and jumper connections replaced will be measured and paid seprately as "Supply only"
Supply only the following items:- Top contact/L contact for drop out fuse. complete all as specified and directed
Lower contact for drop out fuse. complete all as specified and directed
Post insulators of drop out fuse complete all as specified and directed.
Material and labour for taking down burnt jumpers and material and labour for jumper connection between GOD and drop out fuses and transformer with jumper made with copper strip 32x3mm as a conductor duly insulated with GI nut bolt and washers both ends and PVC sleeves 22 kvgrade high tension, with colour code complete all as specified and directed Engr-in-Charge at site.
Material and labour for checking of DC circuit complete from battery bank to HT panels for proper suppy to HT panel controls for smooth functioning of panels complete all as specified and directed.
Material and labour for replacement of battery inter connecting lead /strip with terminal and nut bolt made from lead metal as per sample for connecting of batteries in series of 180/200 AH complete all as specified and directed at site.
Material and labour for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs as per site requirement encased with polythylene sleeve, RYB colours of suitable dia complete all as specified and directed for :- a) Not exceeding 0.75 metre length.
b) Exceeding 0.75 metre length but not exceeding 1.5 metre length.
c) Exceeding 1.5 metre length but not exceeding 2.5 metre length.
d) Exceeding 2.5 metre length but not exceeding 3.0 metre length.
Supply install testing and commissioning 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts suitably tinned to withstand weather proof including taking down existing unserviceable AB switch complete all as specified and as directed.
Dismantling old unserviceable cable ducts from within the panel, supply and fixing PVC cable ducts of size 45x30mm including drawing existing cable through the ducts and commissioning the panel all as directed and specified by Engr-in-Charge.
Supply and fix in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete all as specified and directed by Engr-in-charge.
Material and labour for preperation of old painted steel surface of 6/4/2 pole structure HT/LT street light/HT steel tublar poles 8.5/9.0/11/13 metre long above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering complete all as specified and directed by Engr-in-charge for the following types:- HT 6 Pole structure 11 metre long including channels, nut, bolts and clamps complete all as specified and directed
HT 3 Pole structure 11 metre long including channels, nut, bolts and clamps complete all as specified and directed
HT 2 Pole structure 11 metre long including channels, nut, bolts and clamps complete all as specified and directed
HT pole 11 metre long including channels, nut, bolts and clamps complete all as specified and directed.
LT pole 8.5/9 metre long including channels, nut, bolts and clamps complete all as specified and directed.
Disconnecting the Pole mounted/platform mounted outdoor type transformer situated at various sub station 22/ 0.433 KV 3 phase under DRDO Estate area of any make and transporting to workshop for repairs. Dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections including tap changer switch connection on all 3 phase, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for 100 KVA to 250 KVA complete all as specified and directed. Notes : (i) Copper winding wire/strip will be measured and paid separately as Supply only. (ii) Insulating oil for topping up will be measured and paid separately. (iii) Transportation of transformer for repair and re-installation including connection on HT & LT side, testing and commissioning is deemed to include in quoted rates. (iv) Test result to be submitted after testing of transformer
Supply only super enamelled copper winding wire of various gauges or existing specifications for repair and rewinding of transformers HT coil with insulation including necessary class of insulation complete all as specified and directed.
Supply only DPC copper strip of various gauges or existing specifications for repair and rewinding of transformers LT coil with insulation including necessary class of insulation complete all as specified and directed.
Material and labour for carrying test for acidity of Transformer oil for various Transformers at DRDO Estaste and Test result to be submitted after test complete all as specified and directed by Engr-in-charge.
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 to 500 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed. Note : (i) Defective parts replaced will be measured and paid separately as "Supply only" items here in after. (ii) Cost of required nut, bolts and washer to be included in quoted rates by contractor.
Supply only LT bushings with brass studs of existing specification.
Supply only top cover gasket set.
Supply only radiator flanged gasket 6 mm thick.
Supply only oil level indicator gasket set.
Supply only HT bushing with stud 22 KV of existing specification.
Supply and fix 22 KV Cable Terminal protector Right angle boot to prevent flashover/short circuit due to intervention by Reptiles complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of old painted surfaces of transformer, removing rusted scale/oil & painting of transformer with two coat of synthetic enamel paint of approved make duly Marking/ Writing MES/SM No. complete all as specified and directed by Engr-in-charge for : 100 to 250 KVA capacity of transformer.
300 to 500 KVA capacity of transformer.
Material and labour for disconnecting HT incoming/ Out going for servicing, opening, draw out VCB trolley complete from its position and inspection of complete operating mechnical system, electrical wiring system of AC/DC and complete mechanical calibration of breakers including vaccum cleaning, oiling and greasing to all spares, Checking by draw out mechanism/arrangement of VCB, inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and Checking of alignment with spout and setting of contact gaps complete all as specified and directed Note :- (i) Rate for removal of moisture from breaker by using vaccum cleaner and heating arrangement deemed to be included in quoted rate (ii) Major spare parts are to be paid separetly under supply only items here in after, however cost of minor spares shall be deemed to be included in item rate.
Repair/Maint/Reconditioning of breaker In-Out trolly, including proper allignment of gate, wheel moving channel/rail, ramp etc,repairing of stopper pins, locking pins, replacement of damaged wheels, fixing base etc complete all as specified and directed.Note: Rate quoted is inclusive of necessary welding, bending, straightning work if required as per site requirement complete all as specified and directed.
Material and labour for HT fuse for PT 22 KV 25 KA breaking capacity of rating as per existing for the particular HT panel as per existing shape and size tubular or box type complete with fuse holder all as specified and directed. Note: Fuse shall be checked at site and order shall be done as per sample complete all as specified and directed.
Supply only following spare parts:- Spring charge motor single phase 110/220 volts
Closing Coil 110Volt DC
Tripping Coil 110Volt DC
Top spout with Busbar 22 KV.
Bottom spout with Busbar 22KV.
Power pack
Push button for open and Close.
Micro switches
Indication lamps.
Heaters 200 watts single phase 220 volts along with thermostat suitable for existing to be connected on existing wiring circuits complete all as specified and directed.
Non hygroscopic, track resistance, high strengh epoxy Bus supporting insulators 22 KV as per existing size and shape complete all as specified and directed.
Calibration and testing of combined inverse time over current earth fault and instantaneous relay for checking and cleaning and ensure physical healthiness with visual check for healthy tripping of over current earth fault setting tripping timer ratio setting instantaneous time setting etc as per installed capacity RMU/ Transformers with artifial current injection on primary and secondary with current injection complete all as specified and directed. Note : (a) Contractor will engage authorized persons for calibration of relay with all necessary equipment. (b) Record of relay setting time for each relay and breaker will be maintained by contractor and handed over to department.
Supply and fixing of Touchproof joint 22 KV of cable size 95 to 185 sqmm for RMU complete all as specified and directed by Engr-in-Charge.
Material and labour for removing HT electrical connection at both end of 22 KV HT cable and Hi-Pot Test carried out at any one end ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the UG XLPE cabling system for rectifying defects and test report to be submitted complete all as specified and directed Note: Quoted rate shall include for attending test without time restrictions.
Material and labour for removing HT electrical connection at both end of 22 KV HT cable and Hi-Pot Test carried out at any one end ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the over head lines system for rectifying defects and test report to be submitted. complete all as specified and directed Note: Quoted rate shall include for attending test without time restrictions.
Material and labour for removing HT electrical connection at both end of 22 KV structure/Vcb and HT Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the HT structure 2/4/6 poles and its controlling system for rectifying defects and test report to be submitted. complete all as specified and directed Note: Quoted rate shall include for attending test without time restrictions.
Re-Stringing of HT/LT over head conductor and earth conductors and visual testing of insulator, winding of ACSR as per requirement at site and GI earth wire guard/ earth conductors rigidly with winding wire complete all as specified and directed by Engr-in-charge.
Supply and fix in repair CT 100-75/1 Amp class 1.0 burden 15VA secondary connection 1S1-1S2 suitable for HT 22 KV STC-25KA for 1 sec as per specification with installation calibration and testing complete all as specified and directed.
Supply and fix in repair CT 100-50/1 Amp class 1.0 burden 15VA secondary connection 1S1-1S2 suitable for HT 22 KV STC-25KA for 1 sec as per specification with installation calibration and testing complete all as specified and directed.
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 2.50Ampere to 25 Ampere complete all as specified and directed Make : Jaipuria/ Biecco Lawrie
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 40 Ampere complete all as specified and directed. Make : Jaipuria/ Biecco Lawrie
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 75 Ampere Make : Jaipuria/ Biecco Lawrie
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 100 Ampere complete all as specified and directed Make : Jaipuria/ Biecco Lawrie
Supply and fixing in repair HT Right angle boot 22 KV rating on HT side of existing transformer for jointing 22 KV HT cable complete all as specified and as directed.
Material and labour for disconnecting from existing main taking out from LT Panel board for servicing & overhauling LT panel/ LT ACB panel of any make 400 to 1000 Amp, 50Hz 415V AC including taking out existing Mechanism complete with servicing of operating mechnism, testing of triping mechanism complete to make it funtioning smoothly and including replacement of unserviceable spares and fixing in its original position with all connections and testing complete all as specified and directed Note : Spare parts are to be paid separately under respective items here in after as Supply only.
Supply only Following spare parts suitable for LT ACB suitable for 400A-1000 A Capacity complete all as specified and directed. Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories.
Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB
Under voltage tripping device (UVT) 415 volts
Single phae CTS at rating 800/5A
Supply and fixing in repair MCCB 4pole, 400 Ampere, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed
Supply and fixing in repair MCCB 4pole, 250 Ampere, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed
Supply and fixing in repair MCCB 4pole, 200 Ampere, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed
Supply and laying, connect, testing and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings/walls without cable duct) complete including taking down unserviceable cable all as specified and directed by the Engr-in-Charge for the following :- Notes : (i) Excavation, sand cushioning, brick will be measured and paid separately under relavant items. (ii) Cost of jointing material e.g. lugs, thimbles, glands, nut bolt and washers shall include in quoted rates. 240 Sqmm 3.5 core
120 sqmm 3.5 core
95 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
25 Sq mm 4 core
16 Sq mm 4 core
Supply and lay in trenches reinforced precast concrete cable cover class LV, Type I, flat, size 250 mm x150mm x 40mm for cable protection complete all as specified and directed by the Engr-in-Charge.
Material and labour for finding fault of UG cable aluminium conductor armoured of any size by fault locator complete all as specified and directed. Notes : (i) Excavation/earth work/returning filling/relaying of brick and relaying Soft Soil/ Loose Soil for cushioning deemed to including in the rate quoted. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item. iv) work under this item shall be carried out without time restriction/distance.
Material and Labour for straight through joint for UG cable including joint kit for making joint suitable and complete all as specified and directed for the following size :- (a) 10 sq mm to 16 Sq mm, 4 core
(b) 25 sq mm to 50 Sq mm, 3.5/4 core
(c) 70 to 120 Sq mm, 3.5 core
(d) 120 to 185 Sq mm, 3.5 core
(e) 240 to 300 Sq mm, 3.5 core
Material and Labour for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for earth resistance value testing at various sub station complete all specified and directed by Engr-in-Charge : Note : Earth tester of suitable and necessary arrangement will be done by contractor. Note: Record of earth resistance value to be submitted to Engr-in-Charge.
Material and labour for Earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 76 mm dia medium grade and inner pipe 32 mm dia including testing. 3 metre long and having 100x 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm dia holes for nut bolts. buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.5 metre deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32 x 6 mm strip with minimum two Nos of GI nut, bolts and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 Kg bags of carbon based earthing compound. The compound shall be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities! with ph value between 7-9, connected to the earthing test point, FRP fiber reinforced plastic pit cover square not less than 300x300x240 mm with pit cover, including necessary returning, filling and removal of extra soil complete all as specified and directed. Make: Approved Make NOTE: (i) GI strip beyond 7.5 metre will be measured and paid sepeartely. (ii) Resistance of earthing should not more than 2 Ohm. Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground. If the desired result not obtained after testing, the contractor should do re-eathing without any extra cost to Govt.
Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 32x6 mm size galvanised strip.complete all as specified and directed.
Supply and fix LT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 09 metre long complete all as specified and directed. Note : Earth work shall be measured and paid separately.
Supply and fix in repairs LED street light /road way luminaries 45 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply and fix in repairs LED street light /road way luminaries 60 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply and fixing LED flood light 180W energy saving environmental friendly, long life, exclusive innovative die-cast aluminium flood light with highway efficent LED as light source, suitable for highlighting architectural features complete all as specified and directed by Engr-in-Charge.
Supply and fix LED steet light 25 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with toughned glass gaving botton opening separate driver compartment with I66 protection and impact resisdense of IK07 complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 X 200 X 105 mm (internal ) comprising one , one No MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for three phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron complete all as specified and directed. Make : Sintex/National or equivalent
Material and labour for 3 core PVC insulated sheathed copper conductor cable multistranded 3X1.5 sq mm passing through in steel pole DB to street light luminaires at any pole 2/4/9/11 metre height including taking down the unserviceable cable. complete all as specified and as directed.
Supply and fixing in repairs Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 8 kW single-Phase load .Contactor Rating: 40.Amps ( 2-pole ).MCB (single-pole) Rating:63.Amps (2 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T. Make:SWADEEP – 02EC 8kW1P
Supply and fixing in repairs Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kW load equally distributed over 3-phase .Contactor Rating: 40.Amps (4-pole).MCB (single-pole) Rating: 40.Amps (3 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (E-in-C Approved) Contactor: BCH/L&T/Schneider or equivalent MCB: Hager/Schneider/Legrand/L&T Make:SWADEEP – 02EC 12kW3P
Material and labour for cutting of roads/ plinth of width and depth n exc 0.25 metre complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate for making good road/ foot path/ hard standing/ drain/ bldg plinth protection complete all as specified and directed.
Material and labour for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 to 185 sqmm,22 KV complete all as specified and directed by Engineer-in-charge. Note : Three joint shall be measure as a one unit.
Material and labour for repair/ fabrication of outdoor type LT panel doors of any size as per site requirement with locking arrangement made out of any size / thickness mild steel sheet and duly fixed/ welded with suitable size of butt hinges including making good to the disturbed surface of panel complete all as specified and as directed.
Material and labour for painting of out door type LT panel with synthetic enamel paint two coats over a coat of primer including preparation of surfaces complete all as specified and as directed.
Material and labour for fabrication and installation of Glow Sign Board in size 1828.8mm x 1219mm x 177.8mm made of Flex/ Acrylic board, digital contents all as directed Engineer-in-charge at one side of the board, GI plain sheet, cubical open the flex/Acrylic board and suitable for mounting on wall /gate complete all as specified and directed by Engineer-in-Change. Note :- The cost of Fabrication and welding work is included in the quoted rate .
Excavation in trenches not exceeding 1.5 metre wide and depth exc 1.5 metre and not exc 3.0metre getting out in the following type of earth stata complete all as specified and as directed:- (a) Soft / Loose Soil
(b) Hard /Dense soil
(c) Soft/ Disintegrated rock
Star Electrical (BID ID -3311223)
YOGESH ELECTRICALS (BID ID -3311901)
ASHA ASSOCIATES (BID ID -3310354)
GANGA ENTERPRISES (BID ID -3311831)
SKS Electricals (BID ID -3311653)
PAMS ENTERPRISES (BID ID -3312502)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .