Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-AOC | ₹6.2 Cr Quoted ₹6.5 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹6.5 Cr+₹2.3 L (0.35%)Rejected-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | ₹6.5 Cr+₹2.3 L (0.35%) | L2 | Rejected-AOC Reject |
| 3 | L3₹6.5 Cr+₹2.4 L (0.38%)Rejected-AOC 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹6.5 Cr+₹2.4 L (0.38%) | L3 | Rejected-AOC Reject |
| 4 | L4₹6.5 Cr+₹3.3 L (0.51%)Rejected-AOC A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | ₹6.5 Cr+₹3.3 L (0.51%) | L4 | Rejected-AOC Reject |
| 5 | L5₹6.5 Cr+₹4.3 L (0.66%)Rejected-AOC 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | ₹6.5 Cr+₹4.3 L (0.66%) | L5 | Rejected-AOC Reject |
Tender Value
₹6.4 Cr
EMD Value
₹12.9 L
Closing Date
23 Jan 2023, 1:00 pmClosed
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer M/Garh W.S. Mech. Divn., Narnaul, 123001
Replacement of 05 Cs to 50 Cs VT Axial Flow Pumps with connected electric equipments at Pump Houses MB-1 to MB-4 of Madhogarh Branch, MGD-1 to MGD-3 of Madhogarh Disty. , GM-1 and GM-2 of Gopalwas Minor in W.S. Mech. Division Narnaul.
2022_HRY_251958_3
4980-95/9-A dated 27/12/2022
Open Tender
Pumps/Motors
Works
240 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
Yes
₹12.9 L
Yes
NARNAUL
14 Jul 2023
30 Dec 2022
24 Jan 2023
30 Dec 2022
23 Jan 2023
30 Dec 2022
11 Jan 2023
Amount
Replacement of 50 Cs existing V.T. axial flow pump of lift height 23.02' of RPM 745, including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (01 No. at MB-2)
Replacement of 20 Cs existing V.T. axial flow pump of lift height 23.02’ with RPM 986, including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (2No. at MB-3)
Replacement of 17.5 Cs existing V.T. axial flow pump of lift height 27.94’ with RPM 986, including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve & support of bend with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (1 No. at MB-4)
Replacement of 10 Cs existing V.T. axial flow pump of lift height 27.94’ (MB-4) ,29.07’with RPM 980 (MGD-1) with RPM 980 & 22.98'(MGD-2) with RPM 1440 including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (2 No. at MB-4, 3 No. at MGD-1 & 2 No. at MGD-2)
Replacement of 5 Cs existing V.T. axial flow pump of lift height 23.02’ with 1440 RPM including MS Delivery pipe, bend with all flanges, Y-Body, syphon breaker valve with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (1 No. at GM-1 & 01 No. at GM-2)
Supply, Erection and commissioning of induction motors solid shaft of 225 HP suitable for 50 Cs VT axial flow pumps, 167 KW, 745 RPM, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements alongwith Lightining Arrester 08 No.(2 No. each at MB-1 to 4). (1 No. at MB-1 & 01 No. at MB-2)
Supply, Erection and commissioning of induction motors solid shaft of 100 HP suitable for 20 Cs, 15 Cs & 10 Cs VT axial flow pumps, 75 KW, 980 RPM,6 Pole, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements. ( 02 No. at MB-1,2 No. at MB-3,02 No. at MB-4, 03No. at MGD-1 )
Supply, Erection and commissioning of induction motors solid shaft of 120 HP suitable for 20 Cs, 15 Cs & 10 Cs VT axial flow pumps, 90 KW, 980 RPM,6 Pole, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements. (01 No. at MB-4 )
Supply, Erection and commissioning of induction motors solid shaft of 60 HP suitable for 10 Cs VT axial flow pumps, 45 KW, 1440 RPM, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements. (2 No. at MGD-2)(Solid Shaft)
Supply, Erection & Commissioning of ATS Starter suitable for 120 HP motor as per approved technical specification. (05 Nos for MB-4, 02 No. at MGD-1) (Annexure-C,D,F)
Providing and commissioning of LTDB of Capacity 1250 Amps including all accessories as ACB,1250 Amps -01 No incomer,MCCB 630 Amps-03 nos outgoing & MCCB -250 Amp. - 03 Nos. outgoing, 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation of Motors of capacity 225 HP,100 HP & 30 HP as per specification approved by Tech committee. (01 No at MB-2,) Supply , Erection & Commissioning of Capacitor Bank 30 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. ( 02 No. at MB-1, 01 No. at MB-2, 06 No. at MB-3 & 02 No. at MB-4) (Annexure-C,D,F)
Providing and commissioning of LTDB of Capacity 1250 Amps including all accessories as ACB,1250 Amps -01 No incomer,MCCB 400 Amps-03 nos outgoing & MCCB -250 Amp. - 03 Nos. outgoing, 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation of Motors of capacity 120 HP & 100 HP as per specification approved by Tech committee.(01 No at MB-4) Supply , Erection & Commissioning of Capacitor Bank 40 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. (03 No. at MB-4) Supply , Erection & Commissioning of Capacitor Bank 15 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. (01 No. at MB-1, 01 No. at MB-2 & 01 No. at MB-3) (Annexure-C,D,F)
Providing and commissioning of LTDB of Capacity 1600 Amps including all accessories as ACB,1250 Amps -01 No incomer,MCCB 630 Amps-03 nos outgoing & MCCB -250 Amp. - 03 Nos. outgoing, 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation of Motors of capacity 225 HP & 100 HP as per specification approved by Tech committee.(01 No at MB-1) Supply , Erection & Commissioning of Capacitor Bank 90 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. (03 No. at MB-1 & 03 No. at MB-2) (Annexure-C,D,F)
Supply of LT Armoured PVC Alluminum cable of size 630 sqmm 3.5 core confirming to IS 7098-1995 as per approved make.
Supply of LT Armoured PVC Alluminum cable of size 240 sqmm 3 core confirming to IS 7098-1995 as per approved make.
Supply of LT Armoured PVC Alluminum cable of size 185 sqmm 3 core confirming to IS 7098-1995 as per approved make.
Supply of LT Armoured PVC Alluminum cable of size 95 sqmm 3 core confirming to IS 7098-1995 as per approved make.
Supply, Erection & Commissioning of ATS Starter suitable for 225HP motor as per approved technical specification (01 Nos for MB-1) (Annexure-C,D,F)
S/E/C of MS Component duly dual painting as a) Outer Jaal Made of 40x40x6mm MS Angle and 35x6 MS Flat for 16X2 Sq mtr b) Internal Jaal Made of 40x40x5mm MS Angle and 35x6 MS Flat for 16X13.2 Sq mtr c) Trash Rack Made up of 75x40mm Channel, and 75X8mm Flat d) Open Rack made up of 40x40x5mm Angle, 35x6mm Flat. e) Safety grills made up of 40x40x5 mm angle, 35x6 mm Flat (Detail attached) as per approved make : Jindal/Sail/TATA
Avon Engineering Company
M/s KRP Engineering Pvt. Ltd.
MOHINI ELECTRICALS LTD.
ace marketing pvt ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .