Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAdmitted-Finance AT POST RAY DIST RANCHI 829209 | RAY | RANCHI | JHARKHAND | 829209 | ₹9.2 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical AT BACHRA P O BACHRA DIST CHATRA JHARKHAND | - | - | Rejected-Technical As per NIT |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per NIT |
| 4 | Rejected-Technical PANCHSHEEL NAGAR PANDRA MEHAL RANCHI | - | - | Rejected-Technical As per NIT |
| Sl No | Description | Qty | Unit | M/S DEVNANDAN SHARMA L1 |
|---|---|---|---|---|
| 1.00 | Supply and fixing of double door, 45” × 40” sheet‑steel / pre‑coated alu‑zinc enclosure suitable for one 400 A incoming feeder and 1 spare + two 250 A outgoing feeders, each provided with overcurrent and earth‑leakage protection, for installation on a 500 kVA, 415 V Avantika transformer. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 630 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | 1,63,847.39 ₹1.6 L |
| 2.00 | Supply and fixing of double door, 45” × 40” sheet‑steel / pre‑coated alu‑zinc enclosure suitable for one 400 A incoming feeder and 1 spare+ 1 number 250 A outgoing feeders, each provided with overcurrent and earth‑leakage protection, for installation on a 500 kVA, 415 V Chamatu transformer. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 630 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | 1,67,354.15 ₹1.7 L |
| 3.00 | Supply and fixing of double door, 45” × 45” sheet‑steel / pre‑coated alu‑zinc enclosure suitable for one 315 A incoming feeder and 2 spare + 1 250 A outgoing feeders, each provided with overcurrent and earth‑leakage protection, for installation on wb 13 power distribuion pannel. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 415 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | 1,19,760.44 ₹1.2 L |
| 4.00 | Supply and fixing of double door, 66” × 36” sheet‑steel / pre‑coated alu‑zinc enclosure designed for housing two 100A manual changeover switches, enabling separate switching between two DG sets and JBVNL grid supply to two 125A outgoing feeders.Each provided with overcurrent and earth‑leakage protection, for installation on wb 15 power distribuion pannel. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 345 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | 1,46,416.41 ₹1.5 L |
| 5.00 | Double door pole mounted 10" X 26" MCCB box for local shut down of outgoing LT overhead line branches and fast fault location and clearance.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 11 | No. | 19,757.2 ₹2.2 L |
| 6.00 | Single door pole mounted 10" X 26" MCCB box for Installing of existing mccb is required 3 phase power isolation of power in weighbridges. | 10 | No. | 6,571.04 ₹65,710.44 |
| 7.00 | Earth leakage Relay 110 - 415 VAC,110-220 VDC Manual and Auto reset(Make-L&T,Siemens or ABB) for installation in previously installed busbars. | 5 | No. | 2,909.14 ₹14,545.71 |
| 8.00 | 1 phase and 3 phase Current protection relay for over and under current monitoring 230 v Ac auxilliary power Make-L&T,Siemens or ABB) for installation in previously installed busbars. | 3 | No | 2,486.86 ₹7,460.59 |
| 9.00 | Curent transformer 15 va 250/5 for installation in previously installed busbars. | 12 | No | 526.9 ₹6,322.80 |
| 10.00 | CBCT 210 mm ID for installation in previously installed busbars. | 3 | NO | 3,302.05 ₹9,906.14 |
Tender Value
₹11.9 L
EMD Value
₹14,855
Closing Date
20 Apr 2026, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area Bachra,829201
Making arrangement for 415-Volt LT power distribution through busbar panel in various load centers like 5oo kva transformer installed in avantika Campus-Kundi the DG set installed at weighbridge number 13 the generator at weighbridge number 15 for p
2026_CCL_358123_1
GM(MS)/SO(EnM)/e-NIT/26-27/03
Open Tender
Electrical and Maintenance Works
25 days
Office of the Project Officer Magadh OCP, M-S Area
Please Refer NIT
4 documents required · 4 mandatory
₹14,855
19 May 2026
8 Apr 2026
21 Apr 2026
9 Apr 2026
20 Apr 2026
9 Apr 2026
9 Apr 2026 - 17 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply and fixing of double door, 45” × 40” sheet‑steel / pre‑coated alu‑zinc enclosure suitable for one 400 A incoming feeder and 1 spare + two 250 A outgoing feeders, each provided with overcurrent and earth‑leakage protection, for installation on a 500 kVA, 415 V Avantika transformer. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 630 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | - | - | item01 |
| 2 | Supply and fixing of double door, 45” × 40” sheet‑steel / pre‑coated alu‑zinc enclosure suitable for one 400 A incoming feeder and 1 spare+ 1 number 250 A outgoing feeders, each provided with overcurrent and earth‑leakage protection, for installation on a 500 kVA, 415 V Chamatu transformer. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 630 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | - | - | item02 |
| 3 | Supply and fixing of double door, 45” × 45” sheet‑steel / pre‑coated alu‑zinc enclosure suitable for one 315 A incoming feeder and 2 spare + 1 250 A outgoing feeders, each provided with overcurrent and earth‑leakage protection, for installation on wb 13 power distribuion pannel. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 415 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | - | - | item03 |
| 4 | Supply and fixing of double door, 66” × 36” sheet‑steel / pre‑coated alu‑zinc enclosure designed for housing two 100A manual changeover switches, enabling separate switching between two DG sets and JBVNL grid supply to two 125A outgoing feeders.Each provided with overcurrent and earth‑leakage protection, for installation on wb 15 power distribuion pannel. The enclosure shall have fully gasketed doors and covers, fabricated generally from 2.0 mm thick CRCA/GP sheet for structural strength, duly surface‑treated and powder‑coated to ensure corrosion resistance, with a minimum degree of protection of IP54–IP55 for outdoor use.The panel shall be air‑insulated with suitably rated busbars having heat‑shrink/VC sleeves and flame‑retardant busbar covers to prevent accidental contact and support arc‑containment design; busbar current rating shall be 345 A.All construction and protective features shall conform to relevant standards for LV distribution panels and outdoor enclosures, ensuring dust‑ and water‑tightness, mechanical robustness, and safe accessibility through double doors.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 1 | No. | - | - | item04 |
| 5 | Double door pole mounted 10" X 26" MCCB box for local shut down of outgoing LT overhead line branches and fast fault location and clearance.switchgears should be reputed Make such as-L&T,Siemens,ABB or similar brands. | 11 | No. | - | - | item05 |
| 6 | Single door pole mounted 10" X 26" MCCB box for Installing of existing mccb is required 3 phase power isolation of power in weighbridges. | 10 | No. | - | - | item06 |
| 7 | Earth leakage Relay 110 - 415 VAC,110-220 VDC Manual and Auto reset(Make-L&T,Siemens or ABB) for installation in previously installed busbars. | - | No. | - | - | item07 |
| 8 | 1 phase and 3 phase Current protection relay for over and under current monitoring 230 v Ac auxilliary power Make-L&T,Siemens or ABB) for installation in previously installed busbars. | 3 | No | - | - | item08 |
| 9 | Curent transformer 15 va 250/5 for installation in previously installed busbars. | 12 | No | - | - | item09 |
| 10 | CBCT 210 mm ID for installation in previously installed busbars. | - | NO | - | - | item10 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.34 MB
BOQ_371008.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid