| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹37.1 L+₹3.2 L (9.47%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹39.5 L+₹5.5 L (16.4%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹42.6 L+₹8.6 L (25.5%)Rejected-AOC | L4 | Rejected-AOC Not being L1 |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
8 Jul 2021, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
SPECIAL REPAIRS FOR CONVERSION OF LT OH LINE TO LT UG CABLE AT JCOs/ORs MD ACCN AT ASSAY LINE AND MEADOWS LINE AND PROVN OF 32 NOS LED STREET LIGHT WITH POLES FROM MAHINDRA HILL TO ABC LINE ALONG THE SECURITY WALL OF 2 TRG BN, AOC CENTRE UNDER GE (U)
2021_MES_451042_1
GE(U)/SEC/TOKEN/26 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹81,000
Yes
18 Sept 2021
12 Jun 2021
10 Jul 2021
12 Jun 2021
8 Jul 2021
26 Jun 2021
Amount
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.00 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X5mm Mild Steel Angle Iron Frame and 500 mm above the Normal Ground Level complete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 400amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 200 amps ,415 volt ,25 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 Nos Make Legrand model no: 420218/ Equivalent from Schinder/L&T/Hagar (c) MCCB TP,100 Amp, 3 Pole, 415 Volt, 16 KA Breaking Capacity duly connected to Bus-bar as OUTGOING - 04 Nos. MAKE : Legrand model no: 420005 /L&T/Hagar (d) LED indicating lamps with holder for main supply indicating RYB - 01 set (03 Nos) Make AE/L&T (e) Instrument fuse holder, fused 4 amps - 06 Nos.
Note:i) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (ii) All MCCB to be connected with both side Spreader Link. (iii) Quoted rates inclusive of cable gland as required. (iv) Size of the panel board should not be less than 1.0 x1.5x0.35m Quoted rate is inclusive for all the above features.
Supply and lay in trenches/fixed to walls/poles, connecting using LUGS etc and testing of XLPE insulated and PVC sheathed heavy duty LTUG 1100 Volts grade armoured under ground cable with aluminium conductor cable of 2 Core 10 Sqmm all as directed. MAke : Havells/Finolex/KEI/POLYCAB/GLOSTER Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item no:02 above but 4 core 10 Sqmm
All as per item no:02 above but 4 Core 16 Sqmm
All as per item no:02 above but 3.5 Core 25 Sqmm
All as per item no:02 above but 3.5 Core 50 Sqmm
All as per item no:02 above but 3.5 Core 70 Sqmm
All as per item no:02 above but 3.5 Core 95 Sqmm
All as per item no:02 above but 3.5 Core 120 Sqmm
Supply and lay GI tubing , 80 mm bore light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge. Make :- ISI
All as per item no:10 above but 50 mm bore
All as per item no: 10 above but 40 mm bore
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm complete including taking out old unserviceable one all as specifide and directed.
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
All as per item No 15 above but depth exc 1.5 mtr but not exc 3 mtr.
Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25cm thick using excavated soil
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
Supplying and laying un-reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed by Engr-in-Charge.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
Spreading riddled earth ( after preparation of excavated earth) in Cable duct for cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness 18 CM( 6.25 Cm below cale and 11.75 cm above cale) will be measured for payment purpose. The earth removed during excavation to be used as rddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of mass complete all as directed
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed
M&L PCC 1:2:4 type B2 using 20 mm graded stone aggregate for coping of pole complete all as directed
Cutting the existing road straight by manual, depth and width not less than 0.75 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built ( size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/TRUE POWER
Supply and Lay Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed. Note: This wire to be laid along with UG Cable through trenches for earth continuity
M&L for straight Through Joint heat shriankable type suitable for 1100 volt 70 to 120 Sqmm 3.5 core complete all as specified and directed
M&L for straight Through Joint heat shriankable type suitable for 1100 volt 25 - 50 Sqmm 3.5 core complete all as specified and directed
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.00mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 500 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
Note: (i) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (ii) All MCCB to be connected with both side Spreader Link. (iii) Quoted rates inclusive of cable gland as required. (iv) Size of the panel board should not be less than 1.0 x1.5x0.35m Quoted rate is inclusive for all the above features.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.00 mm thick CRCA Sheet of size 0.5MX0.45Mx0.30M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– (a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3.00 mm thick CRCA Sheet of size 0.75 MX.70mX.30 M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 100 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 NosMake Legrand model no: 420015/ Equivalent from Schinder/L&T/Hagar
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, GI pipe of size 50/ 80 mm dia of maximum length 12 meter including jointing materials to carry LT UG cables of size upto300 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed including refilling and making good of disturbed surface . Note : Quoted rate Excluding of GI Pipe 50 / 80 mm dia as required on ground
Disconnection existing LT UG cable of any size from pole/Oh line and connect the same to feeder pillar box by using cable glands , lugs etc as required complete all as directed
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc. complete all as specified and as directed.
Dismantling Insulators from Poles of any description and any size complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the disturbed Span including Line Spacer, etc. complete all as specified and as directed.
S & F hot press moulded SMC junction / terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixied on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed.Make: Hensel/Syntex/C&S/nyptune
S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts, 32 AMPS made out of polycarbonate or bakelite and 1 No MCB SP of 10 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs AND pvc glands, fixed on pole by means of 2 SETS OF clamps made out of MS flat iron of size 25mm x 3 mm COMPLETE all as specified and as directed. Make : Syntex/C&S/Havells.
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, GI Clamps , fittings and fixtures as required for connection of light fittings . ( to be used for Street light connection from JB to Street light).
S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments complete all as specified and directed. Make : Richa/havells/fincab or equivalent.
All as per item No-42 above but of size 6 Sqmm complete all as specified and directed.
Making hole 2 nos on existing steel tubular pole of suitable size for passing of Street light connection wire from Junction Box to street light complete all as directed
Demolition of coping of pole as required for placing of cable protection pipe and making good the same by using PCC 1:3:6 type C-1 complete al as speccified and directed. Note: Quoted rates inclusive of PCC
Cutting the existing building plinth protection by manual, depth and width as required for laying of cable and refill the same with excavated soil up to 80 % plinth portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) and making good of all disturbed surface complete all as specified and directed.
Supply and fix cable route indicator made out of CI round shape of 65 mm dia fixed with MC Angle 25X25X3 Mm of length not less than 45 CM embeded in PCC of size 25CMx25CMx25cm including necessary excavation etc complete all as specified and directed.
S&F LED Street light fixture 90 watt made of pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, cable gland is used for maintaining ingress protection, epoxy powder coated siemens grey finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistant fixed to the housing with SS screws, high efficiency long life LED chip in modules with lumen efficacy of >110 lm/W with PC lens and system lumen 9000 (system efficacy>100 lm/W). Powered by built in electronic LED driver with APFC (SMPS) based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over voltage protection, surge voltage protection, CCT 5700, CRI>70, THD<10%, PF>95, IP66, IK07 life class of 50,000 hrs @ L70, Operating Temperature : 10 to +10 Deg.C, Input Rated voltage : 240 VAC/50 Hz, Driver safety requirement standards : IS 15885-2-13, Test report to be submitted, driver performance requirements : IS 16104, Test report to be submitted, Photo biological safety norms : IS 16108, test certificate to be submitted, certification : LM 79 for luminaries LM 80 for LED Source, Make : SURYA MODEL NO : SLEUL90W IP66(LXN)/ BAJAJ CAT NUMBER : BRTFG 90W LED/ PHILIPS CAT NO: Wipro cat No. LR02-102-XXX-57-XX
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L for street light bracket made out of 40 mm dia GI pipe medium grade 1.2 mtr long complete with 2 sets of FI clamps made out of 40x5 MS flat & nuts, bolts & washer including painting to clamp two coat of aluminium silver paint over a coat of primer complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as required for laying / protection of cable , fixing of light etc and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .