Tender Value
₹8.3 L
EMD Value
₹16,600
Closing Date
24 Feb 2020, 4:00 pmClosed
Superintending Engineer
Operation and Maintenance Circle-II, ATPS, Anpara Thermal Project, Anpara
Spray insulation on turbine cylinders and critical valve and thermal insulation on pipe lines, valves, re-generative equipments etc. along with supply of material during overhauling of Unit 3 of 3x210MW, ATPS, Anpara
2019_RVUNL_411285_1
27/TMD/OMC-II /ATPS/2019-2020
Open Tender
Repair and Maintenance Works
Fixed-rate
ANPARA
As per tender documents
2 documents required · 2 mandatory
₹590
Dy. C.A.O.,C.F.A. and B.O., ATPS, Anpara
₹16,600
19 Apr 2020
10 Dec 2019
25 Feb 2020
10 Dec 2019
24 Feb 2020
10 Dec 2019
Amount
Complete spray insulation and repair of spray insulation on following equipments including supply of self setting cement compound, spray wool alkali silicate binder retainers, M. S. Plate, aluminum shields, S.S. and G.I. wire nettings, removal of old and damaged insulation re-fixing of end shields plastering and finishing as per BHEL norms and specifications. 1. Damage H. P. casing 324 to 360mm insulation thickness. 2. Damage I. P. casing 180 to 270mm insulation thickness. 3. Emergency stop valve and H.P. Control valves 270mm thickness. 4. Interrupter valves and I. P. control Valves 270mm thickness insulation. 5. L. P. Bypass stop and control valves 270mm Insulation thickness. All the above equipments including their end shield on front and rear sides.
Supply and application of thermal insulation on critical steam pipes such as main steam hot reheat, cold reheat, cross around and feed cycles pipes etc. including fixing and fitting of protective covering insulation thickness 50mm silicate and 100mm mineral wool or by 180mm thickness of lightly resin bonded mineral/ rock wool and sheeting’s
ISOLLOYD ENGINEERING TECHNOLOGIES LTD
M/S ANJALI ENGINEERING WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .