| 1 | L1₹22.7 LAccepted-AOC | ₹22.7 L Quoted ₹23.4 L | L1 | Accepted-AOC Being Lowest L1 |
| 2 | L2₹24.7 L+₹1.3 L (5.51%)Rejected-Finance | ₹24.7 L+₹1.3 L (5.51%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹25.3 L+₹1.9 L (8.02%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | ₹25.3 L+₹1.9 L (8.02%) | L3 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Sept 2022, 6:00 pmClosed
GE (AF) Pathankot
GE (AF) Pathankot-145001
REPAIR/ MAINT OF EXTERNAL ELECTRIFICATION, INTERNAL ELECTRIFICATION, COOLING PPLIANCES, WATER SUPPLY PUMP WITH CONNECTED ITEMS AT JANDWAL UNDER GE (AF) PATHANKOT
2022_MES_548543_1
8421/GE/PAF-37/2022-23
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Pathankot
₹80,000
Yes
6 Feb 2023
29 Aug 2022
28 Sept 2022
29 Aug 2022
26 Sept 2022
12 Sept 2022
Amount
Point wiring one light point or one fan point controlled by one switch and point wiring for 5 Amp socket with cables 1.5 Sqmm complete using FRLSH PVC insulated unsheathed, multistranded copper conductor cable and 1 sqmm PVC insulated unsheathed copper conductor single core cable as earth lead, with proper colour coding, drawn through and including PVC conduit/ casing capping with all fitting of suitable size ISI marked, concealed / above surface and including sunken MS box and including new 3 mm thick bakelite sheet for mounting switches, sockets etc, making connections and making good the disturbed surface to match with the existing specifications including taking down existing point wiring complete all as directed for the following:- Note :- (i) Wiring shall be done by using colour code.
All as per above item No 1.00 but with 2.5 sqmm copper conductor cable (multistranded) complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made epoxy powder coated distribution board (when MCBs are to be used) single pole and neutral 240 volts 8 way single door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed by Engr-in-Charge.
All as per srl item No 03 above but 4 way SPN single door with 200 amps rated bus bar complete all as specified and directed by Engr-in-Charge.
All as per srl item No 03 above but 4 way TPN 415 volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods spring loaded, electronic regulator hum free 5 steps and accessories, 230 V, 1200 mm sweep having min air delivery 210 CFM with service value 6.00 BEE and Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge.
Supply only LED lights fitting 1x 18/20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as shown in electrical plate No. 5 of MES schedule 1991 (Part-1) connected to earthing test point all as specified or indicated including testing on completion
Receiving/recording complaints lodged by the user/occupants of water Supply nature, rectification of the fault as per the compaint lodged by the user Overhead Water Tank excluding float valve complete repair to the extent by removing pipe connections, removing faults, including providing stores such as tee, unions, sockets, nuts, bolts required at the site to rectify the fault with regard to complaint lodged and re-fixing the fittings and fixtures to their original position as dismantled complete all as directed to the entire satisfaction of Engineer -in- charge .
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material and depositing where directed n exc 50m and level n exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 80 mm (3”) dia including taking down existing pipe complete all as specified and directed by Engr-In-Charge.
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 50 mm (2”) dia including taking down existing pipe complete all as specified and directed by Engr-In-Charge.
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 40 mm (1.5”) dia including taking down existing pipe complete all as specified and directed by Engr-In-Charge.
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 25 mm (1.0”) dia including taking down existing pipe complete all as specified and directed by Engr-In-Charge.
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 20 mm (3/4”) dia including taking down existing pipe complete all as specified and directed by Engr-In-Charge.
Supply and lay in replacement Ball brass valves, high pressure, with polythene float and flynut complete of size 20 mm dia, screwed for iron pipe or brass ferrule and fixed complete incl fittings all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of 80 mm bore sluice valve type PN-1 double Flanged cost iron type with brass spindle and iron wheel and 16 mm dia iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification including taking down existing valve complete all as specified and directed by Engr-In-Charge.
Supply and fix in replacement Valve, globe conforming to IS 9338, 50 mm (2”) dia pipe including taking down existing valve complete all as specified and directed by Engr-In-Charge.
Supply and fix in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 40 mm (1.5”) dia including taking down existing valve complete all as specified and directed by Engr-In-Charge.
Supply and fix in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm (1”) dia including taking down existing valve complete all as specified and directed by Engr-In-Charge.
All as per item no 27 above but for size 20 mm dia complete all as specified and directed by Engr-In-Charge.
Material and labour for construction of valve pit including necessary excavation and earth work as required including necessary PCC work, brick work, plastering etc all as specified including fixing of MS sheet 6 mm thick cover and angle iron frame with locking arrangement including two coats of red oxide arrangement including two coats of red oxide primer internal size of pit 600X600X600mm complete all as specified and directed by Engr-In-Charge.
Supply and fix in replacement submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well complete of cap 20 HP including taking down existing pump complete all as specified and directed by Engr-in-Charge.
Chemical/ bacteriological analysis and potability test of water obtained from borewell from approved lab and submitting the report in triplicate complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Non Return Sluice Valve for 80 mm dia pipe including taking down existing valve complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement submersible copper cable 16 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including re-assembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed by Engr-in-Charge.
Supply only calcium hypochlorite Granules (65-70%) packing size 45 kg in bucket sealed and stored properly completely packed with Test certoficate and and purchase voucher all as specified and directed by Engr-in-Charge.
Receiving/recording complaints lodged by the user/occupants of electrification nature, rectification of the fault as per the compaint lodged by the user onward KWH meter in respect of main distribution board, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan /bell /light or power sockets, metal clad plug socket complete repair to the extent by removing connections from the system, removing faults in (surface /concealed), circuits, sunken boxes, Junction boxes, main switches, MCBs / DBs any type of utility light fittings, lamp holders, AC, ceiling fan/ exhaust fan and other connected fixtures of internal electrification including providing stores such as wires of appropriate size and conductor matching to existing one upto the length of 2 mtr, insulation tape, screws, nuts required at the site to rectify the fault with regard to complaint lodged and re-fixing the fittings and fixtures to their original position as dismantled complete all as directed to the entire satisfaction of Engineer -in- charge . Note : (i) Any complaint left out / unattendent by the electrician will be communicated to the JE incharge /AGE E/M with reason. No charge will be paid for the complaint till the complaint is resolved. (ii) New material /stores provided for completing the job shall be measured and paid for separetely under relevant items of BOQ. (iii) Contractor shall provide all type of T&P to each electrician for attending the internal electric complaints. (iv) Contractor shall provide the complaint register complaint slip serially numbered in triplicate.
Supply only following parts/items to 37.00 to 73.00 be fixed under item No.36 above complete all as speciifed and directed by Engr-In-Charge. Supply only switch piano type 5 Amps one way AC 230 Volts existing sample
Supply only switch piano type 5 Amps two way AC 230 Volts as per existing sample
Supply only switch piano type 15 Amps one way AC 230 Volts as per existing sample
Supply only switch/socket combination outlet 3 pin 5 Amps flush type (Multi purpose) piano type AC 230 Volts as per existing sample
Supply only switch/socket combination outlet 5 pin 15 Amps flush type (Multi purpose) piano type AC 230 Volts as per existing sample
Supply only ceiling rose 65x50mm two to three terminal AC 230 volts
Supply only Bell electric AC 230 Volts single pole
Supply only Bell push, flush type, 5 amp
Supply only lamp holder insulated body with back plate batten/angle type for batten fittings
Supply only Sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 30 Amps (SP)
Supply only LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size
Supply only LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose
Supply only round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply only cable flexible PVC insulated twin core with copper conductor of size 1.5 Sq mm complete all as specified and directed by Engr-in-Charge.
Supply only cable flexible PVC insulated twin core with copper conductor of size 2.5 Sq mm complete all as specified and directed by Engr-in-Charge.
Supply only plug top 3 pin 5 Amp AC 230 volts.
Supply only plug top 3 pin 15 Amps AC 230 volts.
Supply only PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engr-in-Charge
All as per Items No 54.00 above but size 175 x 100 x 50 mm deep
All as per Items No 54.00 above but size 200 x 150 x 50 mm deep
All as per Items No 54.00 above but size 350 x 300 x 50 mm deep
Supply only bakelite sheet not less than 3 mm thick for boxes of any size complete all as specified and directed by Engr-in-Charge
Supply only capacitor AC 440 volts 2.5 mfd oil filled suitable for ceiling fan
Supply only capacitor AC 440 volts 3.15 mfd oil filled suitable for exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply only 240V, 10 KA 'B' curve MCB SP and current carrying capacity 5 to 32 Amp, in the MCB DB Complete with connection testing and commissioning.
All as per Items No 61.00 above but SP 40 AMP
Supply only 240V, 10KA 'C' curve MCB SP and current carrying capacity 5 to 32 Amp in the MCB DB complete with connection testing and commissioning
Supply only 240V, 10KA 'C' curve MCB SPN and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning
Supply only 240V, 10KA 'C' curve MCB SPN and current carrying capacity 40 to 63 AMP in the MCB DB complete with connection testing and commissioning
Supply only brass/copper thimble (lugs) bottle type suitable for MCBs with sub circuit wires
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engineer in charge.
Supply only Rigid non-metallic PVC conduit of external dia 20 mm exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed by Engineer in charge.
All as per Items No 68.00 above but of external dia 25 mm
All as per Items No 68.00 above but of external dia 40 mm
Supply only twin sub main wire 4.00 Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable including continuous earth wire 4 Sqmm copper conductor insulated unsheathed complete all as specified and directed by Engr- in -charge.
All as per Items No 71.00 above but of 2x2.5 sq. mm + 1x2.5 Sqmm earth wire
All as per Items No 71.00 above but of 2x6.0 sq. mm + 1x6.0 Sqmm earth wire
Taking out LT cable of any size and any no. of cores from trenches and removing for relaying or replacement all as specified and directed by Engr-in-Charge
Labour only for Re-Laying fixing or passing through pipe only LT 1100 Volts grade Underground cable of any size including connections from LT panel board recovered item as above in trenches all as specified and directed by Engr-in-Charge
Supply Laying fixing or passing through pipe only U/G cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120.0 sq mm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 77 above but for size 95 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 77 above but for size 50 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 77 above but for size 35 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 77 above but for size 25 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 77 above but for size 16 sqmm 4 core complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 77 above but for size 16 sqmm 2 core complete all as specified and directed by Engr-in-Charge.
Sand filling in trenches for cushioning of UG cables as layers of 8cm before laying and 15 cm after laying of cables complete all as specified and directed by Engr-in-Charge.
Supply & lay Sub class 'B' old size well burnt brick laid flat in trenches as protection to cable complete all as specified and directed by Engr-in-Charge.
Material and labour for straight through joints suitable for under ground armoured cables 1100 Volts of size 50 to 95 Sq mm 3.5 core heat shrinkable complete all as specified and directed by Engr-in-Charge.
Material and labour for straight through joints suitable for under ground armoured cables 1100 Volts of size 120 to 185 sqmm 3.5 core heat shrinkable complete all as specified and directed by Engr-in-Charge.
Earthing complete with copper earth plate electrode 600mm x600mm x 3.15mm thick burried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less than 1.25 Mtr below normal ground level connected with 20mm x 3mm copper strip as earthing lead by means of bolts, nuts, check nuts & washers upto DB/Meter board including pit made by PCC 1:2:4 type B-1, RCC cover with suitable handle excavation and earth work in any type of soil, Medium grade GI watering pipe 20mm bore with funnel and wire mesh cmplete all as shown in electrical plate No. 5 of MES schedule 1991 (Part-1) connected to earthing test point all as specified or indicated including testing on completion
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specifed and directed by Engrs-in-Charge.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specifed and directed by Engrs-in-Charge.
Repair of transformer of 100 KVA capacity copper wounded 1 No, step down 11 KV / 440 Volt to any authorised workshop with the following:- (a)Transportation of transformer copper wound 1 No., step down 11 KV / 440 Volt to any authorised workshop to facilitate the repair work. Transformer to be collected from Sub station at Jandwal at Pathankot and back to same site after carrying out the repair work, complete all as specified. (b) Opening the transformer, draining of oil and taking out core of tranformer by disconnecting the same from HT / LT bush rods, opening of core lamination and taking out all the HT coil of the transformer. (c) Rewinding of damaged HT coils with standard copper enamelled conductor including necessary insulating material such as paper insulating, cotton tape sleeves etc varnishing the complete HT coils including newly wound with 'F' class insulating varnish complete all as specified. (d) Assembling of laminations of core after inserting the newly wound coils with other coils and making connections of entire HT / LT limbs complete. (e) Heating the assembled core in oven to desired temperature and testing the same for required insulation result of transfomer.(f) Assembling of transformer after carrying out the repair work and making all HT / LT connections with respective bush rods. (g) Dehydration of transformer oil (drained from transformer) to get dielectric strength not less than 40 KV in 1st tripping with 5mm electrode gap and filling the same in transformer including any oil required to top up the transformer complete all as specified and directed by Engr-in-Charge.
All as per Item No 93.00 above but Transformer of capacity 200 KVA complete all as directed by Engr-in-Charge.
Repair to Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 150 KVA complete all as specified and dirtected by Engr-In-Charge.
Supply and fixing in replacement MCCB 125 Amp, 16 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCCB 100 Amp, 16 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCCB 63 Amp, 16 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.
M&L for repair of Ceiling Fan 1200 mm sweep including rewinding and replacement of bearing set, if required complete all as specified and directed by Engr-in-Charge.
M&L for repair of Exhaust fan any sweep including rewinding and replacement of bearing set, if required complete all as specified and directed by Engr-in-Charge.
M&L for repair of VCB any type complete incl the replacement of defective and UNSV parts complete all as specified and directed by Engr-in-Charge.
Comprehensive/preventive maintenance of the following Window / Split ACs/ Water cooler/ Refrigerator/ Deep Freezer of different capacities by carrying out periodical maintenance of equipment including cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injector required for cleaning condenser/ cooling coils complete and attending complaints all as specified and as directed by Engr-In-Charge for 1.5/2.0 Ton capacity Split AC
All as per item No 102.00 above but of 1.5 / 2.0 Ton capacity window type AC
All as per item No 102.00 above but of Water cooler of any capacity
All as per item No 102.00 but of Refrigerator of any capacity
All as per item No 102.00 but of Deep Freezer of any capacity Note for item No 102 to 106 : (i) Window/Split ACs/ Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis (ii) Window/ Split ACs are to be maintained for heating as well as cooling mode all as specified and directed. (iii) The contractor shall ensure and assess at the site any initial maintenance required, to make all Window/Split ACs/Water cooler/Refrigerator/Deep Freezer/Desert cooler in fully proper working condition. (iv) After completion of contract, contractor shall hand over all " handed over" Window/Split ACs/Water cooler/Refrigerator/Deep Freezer/Desert cooler in perfect running/functioning condition to the department. (vi) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any breakdown and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect day -to -day complaint of any nature / type. (vii) Penalty for not rectifying the defect in time (within 24 hrs) will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will be deducted from the due payment of contract. (viii) Complaints will be treated as rectified only after user's "Satisfactory slip" is produced by contractor to concerned JE E/M duly signed by User in Full Name with Rank / Designation and Mobile / Office Telephone No. (ix) Cost of attending day-to-day complaint is included in the rate quoted under this item. No extra payment for attending complaint shall be permissible. (x) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule. (xi) Cost of minor spares i.e. insulation to copper tubes, soldering/brazing, internal wiring to cooling appliances are deemed to be included in the item rate. Items other than mentioned will be measured and paid seperately. Labour required to carryout the maint / repair for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor. (xii) Cost of T&P i.e. ladders, tools, brazing, welding, soldering and transportation is deemed to be included in quoted rates
Supply only following parts/items to 107.00 to 113.00 be fixed under item No.106 above complete all as speciifed and directed by Engr-In-Charge. Supply only Running capacitor of capacity 30 to 42 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charge
Supply only Running capacitor of capacity 45 to 60 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charge
Supply only Starting capacitor, 40/60 MFD to 80/100 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Chargeolts
Supply only Starting capacitor, 100/120 MFD to 120/150 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charg
Supply only thermostat switch for cooling appliances as per existing sample complete all as specified and directed by Engr-In-Charge
Supply only Overload relay for cooling appliances as per existing sample complete all as specified and directed by Engr-In-Charge
Supply only Starting relay for cooling appliances as per existing sample complete all as specified and directed by Engr-In-Charge
Supply and filling of Gas R-22 for charging to window/Split Air conditioner/Deep freezer and water cooler to maintain adequate gas pressure complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement single phase preventer (Phase failure relay) suitable for star delta starters, of capacity upto 40 HP with auto, mannual and bypass operation, with time delay setting including wiring and connection with existing star delta starter complete all as specified and directed by Engr-in-Charge.
Material and labour for shifting of Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units if required including testing after shifting complete all as specifed and directed by Engr-In-Charge.
All as per Item No 116 above but shifting of Window Air Conditioner complete all as specifed and directed by Engr-In-Charge.
Material and labour for servicing of AC plant any type and any capacity up to 12.5TR including, cleaning/descaling of cooling coil, insulation of suction and discharge line, oiling, greasing of blower motor, checking of electrical circuit supply and and replacement of defective filter, relay, capacitor, over load protector etc as required, rewiring and cleaning of condensor coils with Acid/ Scale removal compound for removal of scales deposited in condenser coils using suitable size iron rods/brush/water circulating pump etc.complete all as specified and directed by Engr-in-charge. Note: (a) Acid/Scale removal compound and required T&P should be provided by contractor without any extra cost. (b) Items to be replaced needs to be checked only for serviceability and will be measured and paid seperately under respective item of schedule
Supply and fixing Filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement strip heaters 3.0 kilowatt suitable for mounting in AC Plant ducts or as required complete all as specified and directed by Engr-In-Charge.
Material and labour for taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including re-assembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed by Engr-in-Charge
Material and labour for replacement of PVC honey comb fins suitable for cooling Tower of any capacity upto 3x12.5 TR complete as per sample all as specified and directed by Engr-in-Charge
Material and labour for replacement of water distribution flaps of cooling tower of AC Plant of any capacity upto 3x12.5 TR as per sample complete all as specified and directed by Engr-In-C
Material and labour in replacement of air filter of AHU as per sample made of suiable filter with efficiency not less then 90% class 1 to 10 micron, matching with existing sample complete all as specified and directed by Engr-in-Charge.
Material and labour for cleaning of Cooling tower of any capacity by draining out water from inside, and including descaling of base tank and sprinkler including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
Material and labour for cleaning of base tank of Air cooling plant having blower motor of 15 HP capacity by draining out water from inside and including descaling of tank and water sprinklers including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.
Supply and replace / top up of compressor oil N-68 to AC Plant compressor upto adequate level complete all as specified and directed by Engr-in-Charge.
Repair/servicing of air handling unit, cleaning of all duct from A.H.U.to supply air grill and cleaning/descaling of cooling coil, water pressure meter, greasing to bearings and taking out the dust and mud complete all as specified and directed by Engr-In-Charge
Supply and fixing in replacement of LCD display cum operating unit for central AC plant of capacity upto 16.5 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed by Engr-In-Charge
Material and labour for repair of Geyser Assy of capacity 25 / 35 / 50 Ltr including replacement of Geyser element 1.5 KW as per sample, syphen assy incl gasket and NRV complete all as specified and directed by Engr-in-Charge. (Note: Geyser Element, Syphen, NRV and Gasket will be measured and paid separately.
Supply and fixing Geyser element 1.5 KW including connections complete all as specified and directed by Engr-in-Charge.
Supply and fixing syphon assy including gasket & NRV complete all as specified and directed by Engr-in-Charge.
M/S MULTI ENGINEERS
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .