Executive Engineer
23B Netaji Subhas Road 3rd Floor Kolkata 700 001
Supply, Delivery, Erection and Installation of 1 No. 12.5 Mtr. Polygonal High Mast Tower LED Light System
2026_WBAIC_1039421_1
AIC/AED/NIeT-167/26-27
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
30 days
Chinsurah
Please refer Tender documents.
4 documents required · 4 mandatory
₹885
₹7,560
Yes
West Bengal Agro Industries Corporation Limited
25 Aug 2026
25 Aug 2026
14 Sept 2026
25 Aug 2026
11 Sept 2026
26 Aug 2026
1 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & dellvery of 12.5 Mtr. Polygonal High Mast Tower Pole in shaft shape, continuously tapered sections having dimensiens and thickness as reqd. in the design made from high tensile steel conforming to BSEN 10025 gr.S355, high Mast systern tower with 1 hp 3 ph motor (cu winding) trolly top ring moving crane incorporated as per modern mechanical standard as per IS standard standard dimension of Botom A/F 360 mn Top A/F 150 mm, body sheet thicktess of 3/3 mn, Baseplate PCD flange Dia (mm): 440 mm Foundatioun bolt cat. M24/750x6 with its accessories, Mast shaft shall be given in two sections, Hot dip galvanized and suitable for wind velocity as per IS: 875/1987 part 3. It shall also incude accessories for High Mast Including Head frame with min. 1.5 mtr dia suitable for flood light lnstallations, inside wiring arrangernnet, loop box of IP-65 for o/g to luminaires on top mount on mast. [Pole Make: Transrail/Bajaj/ Utkarsh/ BPP after approved, as per EIC with checking QA which is subject to approve by technical authority] | 1 | Set | 1,06,000 | ₹1,06,000 |
| 2 | Construction of sultabłe shallow rainforced foundation as per, standard design as per the manufacturer with 1:1 1/2: 3 cement concrete M-20 gr. for the High Mast considering the safe soil bearing capacity at site as 10T/ sq. mtr, TMT Steel as per IS (05% of CC volume) and about said depth along wth suitable dimesion that conforms sfle bear of high mast with arround height of 300mm above ground, incl, all material and labour Incuding the cost of one set 6 Nos. of foundation nuts and bolts of M24/750mm x 6 Nos (provided with mast) made out of tor Steel and installation at site with wiring complete In all respect i.e. entire satisfaction of Engineer-incharge.Ths civil foundation work incl. for erection of12.5 Mtr high mast tower by earth work ln excavation of foundation trench approx, zone base of cc 900x 900x 1500mm & CC 900 x 900 x 300 mm faced up to base plate incuding removing soil and necessary trimming the side of trench leveling & dressing and around 3.25 sq m. soiling wth jhama picked bricks & M20 CC shallowed above soilng and under top foundation with 1.8 x1.8 mtr area of top foundaton and 150 mm depth complete as per modern engineering practice. | 1 | Set | 19,500 | ₹19,500 |
| 3 | Erection of 12.5 mtr Hlgh Mast Over the civil foundation bolts with help of Trolley fixed moving crane (5 Tonne Capacity and using other modern engineering practices along wth luminaires installation to the end top ring bracket by sutable techiques nd means Incl. necy electrical connection in proper electrical system eg. socketing etc. complete (Transrail Pc) | 1 | Set | 7,300 | ₹7,300 |
| 4 | Supplying of IP-65/65 LED Flood light (of following mentioned make which is comprising minimal productive 19500 lux each luminaire) luminaire having Pressure Die-Cast housing with IP 65/66 protection wide lighting diffuser type. 250 Watt. Selected Model choose from below make : HAVELLS/ OFL-GRYLFLDSLS240XC/ Jaquar/Surya (With 5 Years Warratnty) | 8 | Set | 15,527 | ₹1,24,216 |
| 5 | Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure | 8 | Set | 543 | ₹4,344 |
| 6 | Dual Channel Digital 24 hr & Twilight DIN Ch. Timer Systemin Inside of a 165WG MS sheet panel box as per suitable dimension with GL above 1 Mtr (For Energy Saving Special Cut-off system as ref. on Comment Section***
Supply, Fitting, fixing & connection of following materials Switch gears list: (a) MNX12 contracter 2 No. (b) DPMCB Standard Rating & Make Apvd by EIC= 2 Nos (c) Time Switch (Digital)=2 Nos (accesories make: L&T/Legrand/Crabtree) etc connections incl chair 3 pole connector as I/C etc all complete as per modern engineering practice. | 1 | Set | 18,000 | ₹18,000 |
| 7 | Supplying of mainline cable Power Supplier end to panel wiring cable incoming of 11kV gr. 4 core AL Armoured 16 mm³ make Polycab/ Havells/ Gloster make] with necy. Crimping sockets. | 30 | RM | 300 | ₹9,000 |
| 8 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed | 25 | RM | 162 | ₹4,050 |
| 9 | Supplying of 4 core 10 sq. mm unarmourded Ac Cable trailing cable inside through the pole make: (Polycab/ Havels/ Glostar) | 18 | RM | 192 | ₹3,456 |
| 10 | Supplying & fixing medium gauge 50 mm dia GI Pipe (ISI-Medium) Protection with necessary fittings and Jointing metarials as required | 4 | RM | 330 | ₹1,320 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
Tendernotice_2.pdf
PDF • 1.11 MB
BOQ_2552620.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].