Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹41.3 L+₹1.5 L (3.74%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹42.5 L+₹2.7 L (6.68%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹42.5 L+₹2.7 L (6.80%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹42.6 L+₹2.8 L (7.06%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chabua
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF SUMMER/WINTER APPLIANCES AT AF STNS UNDER GE(AF) CHABUA
2023_MES_592474_1
455/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) CHABUA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) CHABUA
₹80,000
Yes
14 Jun 2023
1 May 2023
5 Jun 2023
1 May 2023
29 May 2023
15 May 2023
1 May 2023 - 8 May 2023
Amount
Shifting/Transporting repairable summer appliances such as Window type AC / Split AC of single phase from various locations to contractor's workshop for checking, repair & replacement of spares including dismantling of unserviceable/sizing/burn compressor unit, re fixing/ jointing the compressor, discharge suction line with parts like capillary tubes & filter, by brazing, Checking any leakage in system (i.e. compressor and condenser) and making good by servicing, flushing/vacuum the whole system, cleaning of condenser etc for 1.5TR to 2TR ACs complete all as specified and as directed and return back the same after repairs in serviceable condition and refixing testing the same in the existing location Note:- Spare parts shall be measured & paid separately under relevant items.
All as per item No. 01 here in before but water cooler of capacity 40 to 80 liters complete all as specified and as directed.
All as per item No. 01 here in before but Refrigerator of capacity upto 320 liters complete all as specified and as directed.
All as per item No. 01 here in before but Deep Freezer of capacity upto 320 liters complete all as specified and as directed.
Supply only rubber grommet with sealed compressor for the window reciprocating Compressor/Split AC of capacity 1.5 ton, complete all as specified and as directed.
Supply only rubber grommet with sealed compressor for the window rotary Compressor/ Split AC of capacity 1.5 ton, complete all as specified and as directed.
Supply only rubber grommet with sealed compressor for the window reciprocating Compressor/ Split AC of capacity 2 ton, complete all as specified and as directed.
Supply only rubber grommet with sealed compressor in repair for the window rotary Compressor/ Split AC of capacity 2 ton, complete all as specified and as directed.
Supply only Capillary Tube (copper) suitable for window type AC/split AC upto 2 Ton complete all as specified and as directed.
Supply only Filter strainer (copper) suitable for window type AC/split AC, complete all as specified and as directed.
Supply only split out door fins type copper condenser of capacity 2 Ton, complete all as specified and as directed.
Supply only Starting capacitor 100/120 mfd, complete all as specified and as directed.
Supply only Starting capacitor 80/100 mfd, complete all as specified and as directed.
Supply only Running capacitor 36 mfd, complete all as specified and as directed.
Supply only Running capacitor 45/50 mfd + 06 mfd, complete all as specified and as directed.
Supply only Running capacitor 50 mfd + 4 mfd, dual cap, complete all as specified and as directed.
Supply only Contactor relay for split type AC complete all as specified and as directed.
Supply only Thermostat switch suitable for window type AC complete all as specified and as directed
Supply only blower Fan (PVC) for split type AC upto 2 Ton Capacity, complete all as specified and as directed.
Supply only inner Blower Fan for window AC complete all as specified and as directed.
Supply only indoor fan motor for split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only outdoor fan motor for split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only indoor fan motor for inverter split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only PCB Board for split type AC upto 2 ton complete all as specified and as directed.
Taking down carefully u/s indoor electronic type PCB at existing location repair and refixing split type AC of capacity 1.5 to 2.0 Ton complete all as specified and as directed.
Supply only 2.5 mfd capacitor for indoor split unit complete all as specified and as directed.
Supply only Swing motor of lower shutter complete all as specified and as directed.
Supply only Rubber bushing for blower motor complete all as specified and as directed.
S & F in repairs Display board for upto 2 Ton AC complete all as specified and as directed.
S & F in repairs Sensor for indoor unit complete all as specified and as directed.
S & F in repairs 1/4" (Brass) service line charging valve complete all as specified and as directed.
S & F in repairs 1/4" dia copper pipe complete all as specified and as directed.
S & F in repairs 1/2" dia copper pipe complete all as specified and as directed.
S & F in repairs 1/2" dia (Brass) suction line valve, complete all as specified and as directed.
S & F repairs, drain pipe suitable for upto 2 Ton cap split AC complete all as specified and as directed.
S & F in repairs, insulation tube (size 1/4"/1/2") for split type AC to insulation copper pipe complete all as specified and as directed.
S & F in repairs, Metal plug top 20 Amps,3pin for split type AC/ window AC complete all as specified and directed.
S & F in repairs, Metal socket plug 20Amps,3pin for split type AC/ window AC complete all as specified and as directed.
S & F in repairs, MCB 20 to 32Amps, C curve complete all as specified and as directed.
Dismantling of blower fan motor for window type AC 1.5/2.0 ton, cutting burnt coils and taking out from the stator, cleaning the slots using primer, rewinding using super enamelled copper winding wire of same size and gauge as existing including insulation materials, replacement of bush (front and rear) made out of gun metal or ball bearing as existing and re-assembling all accessories and testing complete all as specified and as directed.
All as per item No. 40 here in before but split AC out door unit 1.5/2.0 ton complete all as specified and as directed.
Attending complaints of any nature for defective AC of various capacity of split/window type AC and rectification of defects including servicing and necessary repairing and fixing at site and replacing spare as required for smooth functioning of the AC all as directed. Note:- Spare parts shall be measured and paid separately.
Attending complaints only of leakage of refrigerant R-22 for split type AC and rectification on site and charging of refrigerant in system all as directed.
Attending complaints only of leakage of refrigerant R-32 for split type AC and rectification on site and charging of refrigerant in system all as directed.
Supply and charging of refrigerant R-134 complete all as specified and as directed.
Dismantling/Shifting and refixing of split type AC of capacity 1.5 to 2.0 Ton including repositioning of mounting arrangement for indoor / outdoor unit and gas charging of required quantity in the unit complete all as specified and directed. Note:- Refrigerants R-22 & copper pipe shall be measured and paid separately.
Supply & fix in repairs remote control for split/ window AC complete all as specified and directed.
Supply and fix in repairs metal enclosure box single pole and neutral two pin and earth socket with MCB complete all as specified and directed.
Attending complaints of any nature for defective water cooler of any capacity and rectification of defects including servicing and necessary repairing and fixing at site and replacing spare as required for smooth functioning of the water cooler complete all as specified and as directed. Note:- Spare parts shall be measured and paid separately.
All as per item No-49 here in before but Refrigerator of any capacity, complete all as specified and as directed.
All as per item No-49 here in before but Deep Freezer, complete all as specified and as directed.
Dismantling of blower fan motor, cutting burnt coils and taking out from the stator, cleaning the slots using primer, rewinding using super enamelled copper winding wire of same size and gauge as existing including insulation materials, replacement of bush (front and rear) made out of gun metal or ball bearing as existing and re-assembling all accessories and testing for the water cooler/ Deep Freezer complete all as specified and as directed.
Supply only Blower motor for Deep Freezer of capacity 320 liters, complete all as specified and as directed.
Supply only rubber grommet with sealed Compressor for the water cooler of capacity 40/60 Litres, complete all as specified and as directed.
All as per item No. 54 here in before but Deep Freezer of capacity 320 liters, complete all as specified and as directed.
All as per item No. 54 here in before but Refrigerator of capacity 315 liters, complete all as specified and as directed .
Supply only filter strainer (copper) for Refrigerator /water cooler/deep freezer complete all as specified and as directed.
Supply and fix in repairs Cooling coil upto 310 ltr refrigerator, complete all as specified and as directed.
Supply only copper capillary pipe 10 feet long for refrigerator of capacity 315 ltrs complete all as specified and as directed.
Supply only copper capillary pipe 20 feet long for water cooler/deep freezer complete all as specified and as directed.
Supply only timer suitable for various capacity of refrigerator complete all as specified and as directed.
Supply only open type relay with over load protector complete all as specified and as directed.
Supply only thermostat long tail auto defrost for water cooler/ deep freezer complete all as specified.
Supply only Bimetal relay complete all as specified and as directed.
Supply only Heating element complete all as specified and as directed.
Supply only frost free fan motor complete all as specified and as directed.
Supply and fix condenser coil for upto 310 Ltr refrigerator complete all as specified and as directed.
Supply only starting relay suitable for 0.50/ 01 HP compressor motor complete all as specified and as directed.
Supply only thermostat for refrigerator complete all as specified and as directed.
Supply only PCB for refrigerator complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Taking out voltage stabilizer by disconnecting existing cable for u/s stabilizer of upto 5 KVA capacity including repairing / replacement of push on switch, relay transistor, diode, voltmeter, indicator lamp, high low cutout, MCB, complete parts along with testing and commissioning and transportation charges from site to workshop complete all as specified and as directed.
Supply and fix in repairs of wall mounted single phase AC Voltage stabilizer 140 to 280 volt of capacity 05 KVA complete all as specified and as directed.
Supply & Fix in repairs of Fan capacitor of capacity 2.5 mfd epoxy filled type complete all as specified and as directed.
Supply and fix in repairs PCB Board for outdoor unit upto 2 ton inverter type Split AC complete all as specified and as directed.
Supply and fix in repairs PCB Board for indoor unit upto 2 ton inverter type Split AC complete all as specified and as directed.
Taking out servo type voltage stabilizer for 5 KVA capacity including repairing / replacement of push on switch, relay transistor, condenser, voltmeter, preset , indicator lamp, cutout wherever required complete parts along with testing and commissioning and transportation charges from site to workshop all as specified and as directed.
S&F Exhaust fan 300 mm sweep semi commercial metal double ball bearing and any type suitable for SP 230/250 V 50 Hz AC supply complete with louver shutters including 3 core flexible cable 14 RPM complete all as specified and directed.
Supply and fixing wall mounting fans complete with blades, hanging arrangement and accessories, 230 V, minimum 400mm sweep complete all as specified and directed.
Taking down wall mounted Geyser of capacity 25 to 50 ltrs from various location after proper disconnecting the all electrical and water connection and transportation to contractor's workshop for repairs of unserviceable/defective part of geyser, after including refixing the geyser to its existing location. Note:- Spare parts shall be measured and paid separately under relevant items.
Preparation of old painted surface of geyser of capacity 25 ltrs and applying one coat of synthetic enamel paint (white colour) complete all as specified and as directed.
Attending complaints of defective geysers of various capacity 25/50 Ltr, rectification including repair/maintenance defective parts, fixing at site as required for smooth functioning all as directed. Note:- Spare parts shall be measured separately under relevant items.
S&F in repairs PVC insulated sheathed copper conductor 2.5 sqmm 3 core as in connecting wire of geyser complete all as specified and as directed.
Supply only inner tank of geyser capacity 25 ltr made out of 16 SWG sheet Steel suitable for Geyser of any type and make to match the existing size and shape of inner tank of Geyser installed at site. All as specified and directed.
All as per Srl item No 84 above but for Geyser of capacity 50 ltrs complete all as specified and directed.
Supply only automatic thermostat switch for geyser 25 ltrs capacity complete all as specified and as directed.
Supply only Heating element any type, 1500 watts for geyser all as specified and as directed.
S & F repairs in Heating element any type, 2000 watts for geyser all as specified and as directed.
Supply only safety valve/ fusiable plug(brass) 15 mm bore for geyser all as specified and as directed.
Supply only (Neon) Indicator lamp (red/green) round/rectangular type for geyser, all as specified and as directed.
S&F in repairs PVC heavy duty hot and cold water pipe 450mm long fixed both side with brass ferrule nuts for 25/50 ltrs capacity geysers for inlet/out let pipe complete all as specified and as directed.
Taking down ceiling fan of any make and 1200/1400 mm sweep at site, cleaning dust and opening up for examination, cleaning all parts and providing fresh lubricant to bearing/bush (oil or grease required) fixing the fan in position after assembling and adjustment for proper running including replacing of cable PVC copper flexible of size 23/0.0076 three core from ceiling rose to fan including testing for smooth running as specified. Note:- Cost of bearings, bushes, capacitors and other spares etc shall be measured and paid for separately as supply only.
Supply only flexible wire twisted twin core of size 0.5 Sqmm copper conductor cable connected from fan block to 01M long (Provision for ceiling fan & exhaust fan ceiling rose) complete all as specified and as directed.
Materials and labour for servicing of ceiling Fans of 1200/1400mm sweep, varnishing, heating, greasing and removing the old u/s bearing, gun metal, bush etc complete all as specified and as directed. Note:- Spare parts shall be measured separately under relevant items.
Supply only Ball bearing for ceiling Fan No 6200 complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6201 complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6202 complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6203 complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6204 complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6205 complete all as specified and as directed.
Supply only Ball bearing No 6206 for exhaust Fan upto 450mm sweep complete all as specified and as directed.
Supply only Gun metal bush suitable for upto1400 mm sweep ceiling Fan, complete all as specified and as directed.
Supply only Rubber insulator (reel type) complete all as specified and as directed.
Supply only Hanging clamp and Nut bolt with split pin for ceiling Fan complete all as specified and as directed.
Supply only Fan capacitor of capacity 2.5 mfd epoxy filled type complete all as specified and as directed.
Supply only Fan capacitor of capacity 3.5 mfd epoxy filled type complete all as specified and as directed.
M&L in replacement of fan shaft for ceiling fans of 1200/1400 sweep complete all as specified and as directed.
M&L for preparation of old painted surfaces of the body, blades, down rod etc of ceiling fans of size 1200/1400 mm sweep (any make) complete and filing in filing in cavities with approved filler and spray painting with synthetic enameled paint (Glossy white/ pale cream) in the body, blades, down rods complete all as specified and as directed.
All as per item No. 108 here in before but Exhaust Fan upto 450 mm sweep complete all as specified and as directed.
Supply & fix in repairs exhaust fan PVC body 250mm sweep complete all as specified and as directed.
S&F in repairs fan regulator electronic type, step type, 240 Volt complete all as specified and directed.
S&F in repairs modular fan regulator, 120 watt, 2 module 240 Volt complete all as specified and directed.
Supply only of blades of ceiling fan 1200/1400 mm sweep complete all as specified and directed.
Supply only blades of exhaust fan 450/300 mm sweep complete all as specified and directed.
Supply only blades of exhaust fan 480/600 mm sweep complete all as specified and directed.
Supply and fixing in replacement Exhaust fan metal Body frame only for 300/450 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed.
Supply and fix in repairs PCB card for Five star BLDC ceiling remote controlled fan upto 1400 mm sweep complete all as specified and as directed.
Supply and fix in repairs PCB card only for Geyser 25 Ltr capacity complete all as specified and as directed.
Supply and fix in repair/replacement of Exhaust fan louver shutters 300 mm sweep complete all as specified and as directed.
Supply and fix in repair/replacement of Exhaust fan louver shutters 380 to 450 mm sweep complete all as specified and as directed.
Supply and fixing in repairs plug top only 15/16Amps complete all as specified and directed.
M&L for Submain wiring with 2 runs of single core 6 Sqmm 1100 V grade, PVC, insulated FRLS, unsheathed cable, multistranded copper conductor, drawn through and including In casing surface/capping of 20 mm dia minimum and conduit accessories in walls/roofs/floors etc, including provision of PVC insulated FRLS, 6 Sqmm copper conductor as earth continuity conductor (green colour) connected to main earth dolly including taking down old unsv cable complete as specified and directed. Note:- (i) Two runs of cable, one run of earth continuity conductor and one run of casing/capping shall be measured as one RM.
S&F in repairs sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with 2 pin and earth plug and socket complete with one SP MCB of 16 Amp rating 240 Volt suitable for geyser complete all as specified and directed complete all as specified and directed.
S&F in repairs metal plug top 20A (enclosure type) only suitable for geyser complete all as specified and directed.
S&F in repairs mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete for geyser complete all as specified and directed.
Supplying and fixing in repair /replacement 1100 volts grade heavy duty cable PVC insulated aluminium stranded/Solid conductor, served with inner sheathing of PVC sheathed wire, one twin core cable flat or circular of 6 sqmm complete all as specified and directed.
S&F in replacement MS down rod of 15mm dia suitable for fan in any length including threading, drilling holes complete all as specified and directed.
Schedule of Credit
STANDARD ELECTRIC WINDERS
M/s GANDHESWAR PHUKAN
Shree Trilok Electric Corporation
R D Enterprises
M/S K S Enterprise
J D construction
NChetia and Sons Trading
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .