Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC H NO 464 SANT NAGAR SEC 20 FARIDABAD 121002 | FARIDABAD | FARIDABAD | HARYANA | 121002 | ₹2.6 Cr | L1 | Accepted-AOC Accepted due to lower Rates |
| 2 | L2₹2.7 Cr+₹8.4 L (3.17%)Rejected-AOC | ₹2.7 Cr+₹8.4 L (3.17%) | L2 | Rejected-AOC Rejected due to Higher Rates |
| 3 | L3₹2.8 Cr+₹11.0 L (4.16%)Rejected-AOC | ₹2.8 Cr+₹11.0 L (4.16%) | L3 | Rejected-AOC Rejected due to Higher Rates |
| 4 | L4₹2.9 Cr+₹29.6 L (11.2%)Rejected-AOC | ₹2.9 Cr+₹29.6 L (11.2%) | L4 | Rejected-AOC Rejected due to Higher Rates |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
10 Jun 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer Provincial Division PWD BandR Branch Faridabad
Special repair of Government Medical College Chhainsa Erstwhile Gold Field Institute of Medical Science and Research Faridabad to establishment of exclusive COVID 19 Hospital in Faridabad District Civil and PH Works
2020_HRY_130598_1
2469-2518
Open Tender
Civil Works - Buildings
Works
180 days
Chhainsa Village District Faridabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Executive Engineer Provincial Division PWD BandR
₹5.0 L
17 Jun 2020
3 Jun 2020
12 Jun 2020
3 Jun 2020
10 Jun 2020
3 Jun 2020
Amount
Special repair of Government Medical College (Chhainsa(Erstwhile Gold Field Institute if Medical Science and Research, Faridabad) for establishment of exclusive COVID-19 Hospital in Faridabad District [Civil + Public Health Work]
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed with in a lead of 30 meters. (HSR. 6.6)
Earth filling under floors with surplus soil excavated from foundation and taken only from outside the building plinth, in 15 cm layers including ramming watering and consolidating lead upto 30 meters. (HSR 6.13)(a)
Surface dressing of the ground including removing vegetation and inequalities not exceeding15cm deep and disposal of rubbish lead upto 50m and lift upto 1.5m hard/dense soild (HSR 6.25(b)
Scraping Cement Plaster [HSR 8.32 (c ))
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.38)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 meters above plinth level (HSR 10.59)
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved), beams, girders, stairs, columns (Square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position complete in all respects (HSR 10.86 + 10.95 (a)).
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc. excluding steel reinforcement and including centering and shuttering, laid in position complete in all respects(For works upto 1.5 meters below ground level) (HSR 10.90 + 10.95 (a)).
Damp proof course 25 mm thick of cement concrete 1:2:4 using stone aggregate (HSR 10.115) - Note
First class brick work laid in cement sand mortar 1:4 in foundation and plinth (HSR 11.4)
First class brick work laid in cement sand mortar 1:4 in first storey upto 4 meters above plinth level (HSR 11.9)
Plastering on wall 12 mm thick cement plaster 1:6 (HSR 15.7)
Finishing walls with exterior decorative cement based paints such as snowcem Robbiacem etc. on new work, two coats to give an even shade (HSR16.61)
Providing & fixing false ceiling with 12mm thick Gyspem Board on Ms Steel runners frame i/c cost of screws, angles, cleats, rawel plugs, with taping filling with Gyspem compound and applying priming coat etc. complete in all respect (HSR 13.91]
Providing and fixing mineral fibre false ceiling tiles at all height of size 595 x 595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light reflectance 85%, thermal conductivity k = 0.052 – 0.057 w/m, Fire Perforamce as per (BS 476 pt- 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all around galvanized iron sections of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 32mm of length 3000mm, cross T of size 15 x 32mm of length 1200 mm and secondary intermediate cross T of 15 x 32mm of length 600mm to form grid module of size 600 x 600mm suspended from ceiling using galvanized mild steel item (galvanized @ 80gsm) as per [HSR 13.92]
12 mm thick cement plaster 1:4 (HSR 15.5)
Preparation of plastered or concrete surfaces for painting including sand papering the surface, applying one coat of linseed oil and filling with approved quality filler, consisting of white lead, linseed oil, varnish and chalk mitti including finishing [HSR 16.24]
Painting one coat with plastic emulsion paint on walls on old work to give an even shade [HSR 16.31]
Providing two coats of exterior acrylic emulsion paint 1st quality (HSR 16.79(b)
Providing and fixing aluminum work for doors, windows, ventilators and portions with excluded built up standard tubular sections/appropriate Z sections and other sections of approved made conforming to IS;733 and IS;1285 fixed with rowel plugs and screws or with filing clips or with expansion hold fasteners including necessary filling up of gaps at junctions hold fasteners, at top, button and sides with required neoprene felt etc. aluminum sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including clear angle, aluminum snap beading for glazing/paneling C.P. brass/stainless steel screws, etc. complete shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including Aluminum fitting (HSR 17.96 + Note (i)
Providing and fixing glazing in aluminum door, windows, ventilator shutter and partitions etc. with pvc/neoprene gasket etc. complete (cost of aluminum snap beading shall be paid in the basis items) – (a) with float glass panes of 4.0 mm thickness [HSR 17.98(a)]
Providing and fixing glazing in aluminum door, windows, ventilator shutter and partitions etc. with pvc/neoprene gasket etc. complete (cost of aluminum snap beading shall be paid in the basis items) – (b) with float glass panes of 5.00 mm thickness [HSR 17.98(b)]
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS;6315 marked for doors including cost of cutting floors as required embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box – (a) with stainless steel cover plate [HSR 17.99 (a)]
Providing and fixing 12mm thick pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade 1 type II in paneling fixed in aluminum doors. Windows shutters and partition frames with c.p. brass/ stainless steel screws etc. complete – (b) Pre-laminated particle board with decorative lamination on both sides [HSR 17.97 (b)]
Steel reinforcement TMT bars Fe-500 EQR/Fe-500 D grade or more for RCC works, where not including the complete rate of RCC including straightening, bending, binding wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respect for all height/depth/storey/ basement et., Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps, wastage, overlaps, coupling, welded joints, spacers, bars, chair, stays, hangers and annealed steel wiere or other methods for binding and placing shall be deemed to be included in rate of reinforcement (HSR 18.22)
Providing and laying tack coat with bitumen VG-10 grade pressure distributor at the rate of 0.30 kg. per sqm. On the prepared bitumen/granular surface cleaned with mechanical broom including cost of bitumen as per clause No. 503 (5th edition) 2013 as per MoRT&H specification (N.S.)
Providing and laying 20mm thick premix carpet (PC) excluding cost of tack coat, with mixed material brought from Hot Mix Plant and laying with paver finisher and compacting with road roller to achieve specified value of compaction and direction of Engineer including cost of lighting arrangement, sign board and night watch, complete in all respect i/c cost of bitumen VG-10 grade as per clause 510 MoRT&H specification (5th edition 2013 (NS). Note :- Where there is PC on existing black top, before laying PC on existing black top all cracks shall be sealed as MoRT&H specification (5th edition) clause No. 3004.3 which may consts of (i) Fog seal/ or (ii) crack filling and or (iii) patch work repair as required at site in accordance with clause No. 3004.3.2, 3004.3.3 and 3004.2 of MoRT&H specification (5th edition 2013 respectively. Proper measurement and consumption shall be entered in MB for fog seal/ or crack filling/ or patch work but no payment on this account shall be made as fog seal/or crack filling/ or patch work is/are incidental to work.
Providing and laying ‘B’ type seal cost with VG-10 grade bitumen including supply of fine aggregate mixed and heated with mechanical mixer including rolling with road roller etc. complete as per MoRT&H specification (5th Edition) 2013 clause 511 including the cost of bitumen VG-10 grade (N.S.)
Cleaning of building by deploying labour i.e. cleaning and washing of floors which was locked since last five years (NS)
PH WORK Providing and fixing in position 15 mm I/d C.P. brass bib cocks of best quality (as required by the engineer In charge) HSR 30.75 (a) Bib cock long body
(c) Bib cock
Providing and fixing in position C.P brass stop cocks (as approved by the Engineer-in-Charge) HSR 30.76 (a) 15mm stop cock (i) Stop cock male and female end.
Providing and fixing in position best indian make flexible tube connection [HSR 30.82] (b) C.P brass i) 15mmx300mm.
Providing and fixing 40mm 1/0 G.I. waste pipe embedded inw alls or lead waste pipe weighing 4.46 Kg./metre and 3.0mm thick upto floor level as required by the Engineer-in-charge including cost of union and plumber joint [HSR 30.62]
Providing and fixing 40mm i/d chromium plated brass pipe to wall with wall flange, complete (as per requirement of the Engineer-in-charge) for use with sinks [HSR 30.63] a) with bottle trap (India make)
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE LAVATORY SUITES (WITH ANTI SPLASH RIM IN VITREOUS CHINAWARE and all other necessary fittings as fully described in item no. 30.41 above- WHITE-[HSR 30.42] (ii)]Size 530 mm x 430 mm with one no. trap
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE CHROMIUM PLATED BRASS 2ND TRAP FOR LAVATORY SUITE [HSR 30.45]
Providing and fixing in position best Indian make (as approved by the Engineer-in-charge) European type water closet suite, Syphonic type, consisting of- Single trap symphonic W.C. Suite- White [HSR 30.5 (a) (i)]
Providing and fixing in position super quality 65mm i/d opening C.P. brass dome type hinged grating weighing about 750 gms fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge)[HSR 30.74]
Providing and fixing HDPE water storage tanks of sintex, Diplast, O.K. supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing Iin position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour provisions with suitable plug on scour pipe including cost of nipples, washers, flanges for connections in tanks complete in all respects to the satisfaction to the Engineer. HSR 30.119 (a) 5000 Ltr. Cap.
Providing and fixing in position best Indian make bevelled edge 5.5 mm thick mirror mounted on asbestos sheet ground fixed in position by means of 4 nos. chromium plated brass screws and washers over rubber washers and rawl plug embeded in the wall or chromium plated brass clamps with C.P. brass screws (as required by the Engineer -in -charge) complete including cutting and making good the walls etc. [HSR 30.71] (a) Indian make (I) 600mmx450mm
Providing and fixing in position best Indian make soap dish fixed into wall with C.P. brass screws and complete in all respects including cutting and making good the walls etc.(HSR 30.70) (a) C.P. Brass (i) Soap dish 160mm
Providing and fixing in position automatic brass ball valves in tanks;(HSR 30.110) b) WITH PLASTIC WALL (v) 40mm internal diameter
DSR Items Providing and fixing G.I. pipes complete with G.I. fitting and clamps, i/c cutting and making good the walls etc. internal work – exposed on wall [DSR 18.10](i) 15mm internal diameter of pipeline
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (DSR 18.46)(a) 15mm nominal bore
Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (Screwed end)(DSR 18.17) (i) 20mm I/d
M/S DEV PARYAG BUILTECH PVT. LTD.
M/S Mohan Lal
SRM Buildtech Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .